Loading...
HomeMy WebLinkAbout1.8-6825 Ph 2E C L 1 12 3 4 5 6 7 8 9 10 J Lua 10' 10' z PUE Lu D_ 6' 1- z 1� U PAD—MOUNTED /ngs EQUIPMENT e e SUBSURFACE TRENCH ENCLOSURE CENTERLINE .TYPICAL INTERIOR STREET NO SCALE LOT 1' MIN LOT LINE 12.5' GSTC 1'-6" STUB (TYP.) W I � a 0_ _ 01 _�_____ /W L -- _ _ R MAIN TRENCH b GSTC STUB�I -- -- , -- -- R/W p LOT LINE V-6" TYPICAL INTERIOR STUB INSTALLATION NO SCALE JOINT TRENCH RECAP RULE 15/16 PM: 31286821 TRENCH OCCUPANTS DISTRIBUTION OR SERVICE TRENCH SIZE DEPTH FOOTAGE BACKFILL SURFACE GSTC DIST 24" x 59" 117' SPREAD DIRT GPTC DIST 24" x 59" 1,097' SPREAD DIRT GPSTC DIST 24" x 59" 2,217' SPREAD DIRT GTC DIST 24" x 59" 96' SPREAD DIRT PC DIST 24" x 59" 20 SPREAD DIRT G DIST 24" x 59" 1,226' SPREAD DIRT T DIST 24" x 59" 107' SPREAD DIRT S DIST 24" x 59" 8' SPREAD DIRT GSTC SERV FRANCH 18" x 46" 980' SPREAD DIRT GSTC SERV PRIVATE 18" x 46" 382' SPREAD DIRT JOINT TRENCH RECAP MINIMUM SEPARATION AND CLEARANCE REQUIREMENTS (Inches) o so N L L: O Z G GAS TRENCH OCCUPANTS DISTRIBUTION OR SERVICE TRENCH SIZE DEPTH FOOTAGE BACKFILL SURFACE GSTC DIST 24" x 59" XXX' SPREAD DIRT GPTC DIST 24" x 59" XXX' SPREAD DIRT GPSTC DIST 24" x 59" XXX' SPREAD DIRT S DIST 24" x 59" XXX' SPREAD DIRT G DIST 24" x 59" XXX' SPREAD DIRT GSTC SERV FRANCH 18"x46" XXX' SPREAD DIRT GSTC SERV PRNATE 18' x 46" LS 2A STREET LIGHT LOCATION (SEE NOTE 11) SPREAD DIRT R Ml LIDINAM,0110641 1. DEVELOPER TO DO ALL TRENCHING, SHADING, AND BACKFlWNG. PER UO STANDARD S-5453. 2. PHONE AND CABLE TV FACILITIES ARE SUBJECT TO CHANGE AT THE DISCRETION OF THOSE COMPANIES. 3. PADS, BOXES AND OTHER FACILITES ARE M SHOWN TO SCALE. 4. GAS AND ELECTRIC FACILITIES WILL REQUIRE SAND SHADING IF NATIVE SOIL IS NOT ROCK -FREE. PG&E WILL INSPECT BACKFILL MATERIAL. TEL AND/OR CAN MAY ALSO REQUIRE 12. OF SAND BACKFILL. 5. GROUND TO BE WITHIN .2 FT OF FINISH GRADE PRIOR TO TRENCHING. 6. GAS AND ELECTRIC FACILITES REQUIRE AT LEAST 3' OF SEPARATION (1' UNDISTURBED SOIL) FROM PARALLEL RUNS OF WATER, SEWER, OR STORM DRAIN. 7. PRE -CONSTRUCTION MEETING REQUIRED TWO WEEKS PRIOR TO THE START OF INSTALLATION. 8. CALL U.S.A. AT LEAST 48 HOURS PRIOR TO TRENCHING (DIAL 811) 9. PG&E WALL ASSIST IN LOCATING ENDS OF EXISTING GAS MAINS. 10. DEVELOPER IS RESPONSIBLE FOR OBTAINING ENCROACHMENT PERMITS.. 11. STREETLIGHT LOCATIONS MAY HAVE CHANGED. REFER TO THE APPROVED STREETLIGHT IMPROVEMENT PLAN FOR STREETLIGHT INSTALLATION. 12. DEVELOPER SHALL CONTACT ALL INVOLVED PARTIES PRIOR TO MAKING ANY CHANGES FROM THIS DRAWING. 13. REFER TO EACH PARTYS INSTALLATION INSTRUCTIONS FOR MORE PRECISE DESCRIPTION OF SUBSTRUCTURES AND OTHER REQUIREMENTS. LEGEND: MINIMUM SEPARATION AND CLEARANCE REQUIREMENTS (Inches) o so N L L: O Z G GAS E P ELECTRIC PRIMARY S ELECTRIC SECONDARY T TELEPHONE SL C CABLE TV - / SLASH INDICATES CHANGE IN OCCUPANCY — — — — — PROPOSED SERVICE TRENCH — — PROPOSED MAIN LINE TRENCH 12 EXISTING UNDERGROUND FACILITY 1 L2 --J PROPOSED #2 (17" x 30" x 18") ELECTRIC SPLICE BOX L _j PROPOSED #2E (17" x 30" x 26") SECONDARY ELECTRIC SPLICE BOX L5� PROPOSED #5 (3' x 5' x 3'-6") SUB -SURFACE ENCLOSURE LT] PROPOSED TELEPHONE PEDESTAL\SPLICE BOX rZ-i PROPOSED CABLE SPLICE BOX (17" X 30" X 18" MAX.) 12 PROPOSED PAD MOUNTED TRANSFORMER to' INDICATES TRENCH FOOTAGE & OCCUPANCY --- A� PROPOSED LS 2A STREET LIGHT LOCATION (SEE NOTE 11) (ELECTRIC SECONDARY) PROPOSED SERVICE LOCATION COMPANY 1. WARREN ALBERT P G & E 2. BRIAN FRANZ ATT 3. GREG EOF BRIGHTHOUSE TELEPHONE (661) 398-5960 (661) 631-3492 (661) 395-3351 Utility Standard S5453. 'Joint Trench: Exhibit B, is updated Per this bulletin as follows: 'Must W oonsidered a'U6111y as defined in Utility Standard S5453. 'Joint Trench.' Nobe 4, 5, 7, and 13 aro 1"c W M UbW Stantla,tl 55453 EW1,4 6 "Joint Trench Configurations and O cuoancv Gude" **For ..pd., refer re G.O. 128 rule Sedlon B. Items (11 antl 121. '0i V Z Q� � N W N Id V Q D- LJJ LL. ~ OQ LL. LL 0 N W W W 2 N m O U MINIMUM SEPARATION AND CLEARANCE REQUIREMENTS (Inches) o so N L L: O Z ` O N O 2 N E O DUCT T OB T C S P SL O (OAS) SEE NOTES 4,7, 8 13 - 12 12 12 S 12 6 T (TELEPHONE) DUCT 12 - 1 1 12 12 12 T (TELEPHONE) DIRECT WRY 12 1 - 1 12 12 12 C (CATV) 12 1 1 - 12 12 12 S (ELECTRIC SECONDARY) 6 12 12 12 1.5 3 1.5 P (ELECTRIC PRIMARY) 12 12 12 12 3 3 3 SL (STREETLIGHT) SEE NOTE 5 6 12 12 12 1.5 3 1.5 FE' (FOREIGN ELECTRIC SOURCES, NON.POSE') SEE NOTE 5 12 12— 12— 12— 12 12 12 'Must W oonsidered a'U6111y as defined in Utility Standard S5453. 'Joint Trench.' Nobe 4, 5, 7, and 13 aro 1"c W M UbW Stantla,tl 55453 EW1,4 6 "Joint Trench Configurations and O cuoancv Gude" **For ..pd., refer re G.O. 128 rule Sedlon B. Items (11 antl 121. '0i V Z Q� � N W N Id V Q D- LJJ LL. ~ OQ LL. LL 0 N W W W 2 N m O U O U o so N L L: O Z ` O N O 2 N E O Cy) 00 Oo o a C! U O °o rn o O r rn N io L� (D 0 N .. Q'o rn 1 U1 .ti U z m W I U W J Z O L;.i U C> a CD q a co U c6 tic m U U CL. I O Q c E N N Opt z ti E i 44 v W �iw z � a O GAS NOTE: � > B TRENCH DEPTH NOT TO EXCEED 5' UNLESS (n LLJ W APPROVED BY PG&E INSPECTOR. IN NO CASE m o SHOULD PLASTIC GAS PIPE BE INSTALLED AT A DEPTH GREATER THAN 10' UNLESS APPROVED I I 24• WIDE BY PG&E SENIOR GAS ENGINEER. WHIT N 0) (COMMON) z WHIT N FINISH GRADE y O N 18" < U M MINIMUM 30" MINIMUM IN > � FRANCHISE AREA 30• MINIMUM IN . ' �. ' FRANCHISE AREA FINISH GRADE F O R TRENCH INSPECTION 12* SAND.. -MIN'. c' \ A R H OVER TELE 2• OR 4• .� (24" CALL (559) 263-7312 P A TT. c c:;„>_:.;:: PossBLE se• 30” IN LN STREET) o W w z ":". ":::: .. 71 z Is7 O 12' MIN. ANY CHANGES TO THIS DESIGN MUST O TOP OF GAS LEVEL '," '>..::3• MIN.";� �.�� „ 1�1 ►�. _ NOTE: WITH BOTTOM of 42 C 3" FIRST BE APPROVED BY PG&E. U1 m J TELEPHONE OR ry '::`•': r" 0� Q N ALL SERVICES AND SUB—STRUCTURES ARE NOT TO SCALE FOR CLARITY. ;: s S SL: : P P 4" OR r MIN. GAS ADE. DOMINIC OTHART 0 FLI a v .> ..:.. ALL COMPONENTS SHALL FIT WITHIN THE PUE OR FRANCHISE AREA UNLESS 2" a 4" SHADING " m Qi `n Z O OTHERWISE NOTED. REFER TO DETAILS FOR LOCATIONS. 11 12 PHONE: (661) 398-5817 m x I� aim 1) 2• SAND SHADING AROUND GAS & ELECTRIC IF SOIL IS NOT ROCK FREE 6 1) Y SAND SHADING AROUND GAS & ELECTRIC Z x Cp W W_ j IF NATIVE SOIL IS NOT ROCK FREE LD 2) ONLY PARTIES PARTICIPATING IN U.SA. ARE ALLOWED IN JOINT TRENCH MIN.#4- 2) SE OTHER DETAIL IF NON -PG&E ;00CD W 3) ANY PARTY EXCEEDING ITS TRENCH ALLOTMENT SHALL MAKE STREETUGHT IS IN TRENCH TAFT HWY SPORTS VILLAGE E-4 �. N A ARRANGEMENTS TO ENSURE THAT TRENCH WILL ACCOMMODATE S C'3 ONLY PARTIES PARTICIPATING IN U.S.A. ARE JOINT TRENCH COMPOSITE APPROVED BY:SUBSTRUCTURE VERIFICATION STAMP > WADDED FACILITIES BEDDING MATERIALALLOYYED IN THIS TRENCH NTS4 GAS TO GO ON SIDE OF TRENCH NEAREST STREET GAS ADE: >-IZ E i Z Q DEVELOPER s) TRENCH LAYOUT SHALL CONFORM TO UO STANDARD 55453. 2" J V.J ELECT ADE: Hn PLEASE NOTE AND SIGN FIG. 2 DATE. VICINITY MAP Z N ALL P.G.& E. ENCLOSURES AND BOXES HAVE BEEN SET TO GRADE ACCORDING TO GRADE (VIEW FACING DISTRIBUTION TRENCH) �H V STAKES PROVIDED BY DEVELOPERS ENGINEER. ALL COSTS TO RELOCATE OR RE -ADJUST BOXES AT A LATER DATE WILL BE BILLED TO THE DEVELOPER. PLEASE HAVE YOUR JOB m SUP. VERIFY THE CORRECTED GRADE OF ALL ENCLOSURES AND BOXES. AND SIGN AND TYPICAL DISTRIBUTION TRENCH TYPICAL SERVICE TRENCH �' DATE DRAWING. THANK YOU Z SIGNED NO SCALE NO SCALE NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL 1.8-6825 Ph 2 W W DIAL 811 DATE DRAWINGS FOR ELECTRIC FACILITY PLACEMENT, DETAILS, AND CLEARANCES. ICL_ i 5 4 3 1 INCH 0 7 ME c c o a C! r °o rn a r cc N 0 L� 0 Q'o N m m U z m W I U W J Z O L;.i U C> a a� a 2 m tic (1 U U CL. LLL O Q N GAS NOTE: � > B TRENCH DEPTH NOT TO EXCEED 5' UNLESS (n LLJ W APPROVED BY PG&E INSPECTOR. IN NO CASE m o SHOULD PLASTIC GAS PIPE BE INSTALLED AT A DEPTH GREATER THAN 10' UNLESS APPROVED I I 24• WIDE BY PG&E SENIOR GAS ENGINEER. WHIT N 0) (COMMON) z WHIT N FINISH GRADE y O N 18" < U M MINIMUM 30" MINIMUM IN > � FRANCHISE AREA 30• MINIMUM IN . ' �. ' FRANCHISE AREA FINISH GRADE F O R TRENCH INSPECTION 12* SAND.. -MIN'. c' \ A R H OVER TELE 2• OR 4• .� (24" CALL (559) 263-7312 P A TT. c c:;„>_:.;:: PossBLE se• 30” IN LN STREET) o W w z ":". ":::: .. 71 z Is7 O 12' MIN. ANY CHANGES TO THIS DESIGN MUST O TOP OF GAS LEVEL '," '>..::3• MIN.";� �.�� „ 1�1 ►�. _ NOTE: WITH BOTTOM of 42 C 3" FIRST BE APPROVED BY PG&E. U1 m J TELEPHONE OR ry '::`•': r" 0� Q N ALL SERVICES AND SUB—STRUCTURES ARE NOT TO SCALE FOR CLARITY. ;: s S SL: : P P 4" OR r MIN. GAS ADE. DOMINIC OTHART 0 FLI a v .> ..:.. ALL COMPONENTS SHALL FIT WITHIN THE PUE OR FRANCHISE AREA UNLESS 2" a 4" SHADING " m Qi `n Z O OTHERWISE NOTED. REFER TO DETAILS FOR LOCATIONS. 11 12 PHONE: (661) 398-5817 m x I� aim 1) 2• SAND SHADING AROUND GAS & ELECTRIC IF SOIL IS NOT ROCK FREE 6 1) Y SAND SHADING AROUND GAS & ELECTRIC Z x Cp W W_ j IF NATIVE SOIL IS NOT ROCK FREE LD 2) ONLY PARTIES PARTICIPATING IN U.SA. ARE ALLOWED IN JOINT TRENCH MIN.#4- 2) SE OTHER DETAIL IF NON -PG&E ;00CD W 3) ANY PARTY EXCEEDING ITS TRENCH ALLOTMENT SHALL MAKE STREETUGHT IS IN TRENCH TAFT HWY SPORTS VILLAGE E-4 �. N A ARRANGEMENTS TO ENSURE THAT TRENCH WILL ACCOMMODATE S C'3 ONLY PARTIES PARTICIPATING IN U.S.A. ARE JOINT TRENCH COMPOSITE APPROVED BY:SUBSTRUCTURE VERIFICATION STAMP > WADDED FACILITIES BEDDING MATERIALALLOYYED IN THIS TRENCH NTS4 GAS TO GO ON SIDE OF TRENCH NEAREST STREET GAS ADE: >-IZ E i Z Q DEVELOPER s) TRENCH LAYOUT SHALL CONFORM TO UO STANDARD 55453. 2" J V.J ELECT ADE: Hn PLEASE NOTE AND SIGN FIG. 2 DATE. VICINITY MAP Z N ALL P.G.& E. ENCLOSURES AND BOXES HAVE BEEN SET TO GRADE ACCORDING TO GRADE (VIEW FACING DISTRIBUTION TRENCH) �H V STAKES PROVIDED BY DEVELOPERS ENGINEER. ALL COSTS TO RELOCATE OR RE -ADJUST BOXES AT A LATER DATE WILL BE BILLED TO THE DEVELOPER. PLEASE HAVE YOUR JOB m SUP. VERIFY THE CORRECTED GRADE OF ALL ENCLOSURES AND BOXES. AND SIGN AND TYPICAL DISTRIBUTION TRENCH TYPICAL SERVICE TRENCH �' DATE DRAWING. THANK YOU Z SIGNED NO SCALE NO SCALE NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL 1.8-6825 Ph 2 W W DIAL 811 DATE DRAWINGS FOR ELECTRIC FACILITY PLACEMENT, DETAILS, AND CLEARANCES. ICL_ i 5 4 3 1 INCH 0 7