HomeMy WebLinkAbout1.2-7302 Ph 3 & 4PG&E GAS NOTES: CALL 811 (1-800-227-2600) A MINIMUM OF 2 BUSINESS DAYS (NOT INCLUDING INITIAL DAY OF CONTACT) IN ADVANCE FOR THE MARKING OF UNDERGROUND UTILITIES, INCLUDING ALL NON—UTILITIES BEFORE YOU DIG, GRADE, OR EXCAVATE. ANY UNDERGROUND STRUCTURE SHALL MAINTAIN A MINIMUM OF 7 FT. (WITH 3 FT. OF UNDISTURBED SOIL) HORIZONTAL SEPARATION AND 24 IN. OF VERTICAL SEPARATION FROM THE EXISTING 34" PACIFIC GAS & ELECTRIC TRANSMISSION LINE. ADDITIONALLY, NO LESS THAN 72" OF COVER IS TO BE OVER THE EXISTING TRANSMISSION LINE AT ANY TIME. AT NO TIME SHALL POWER DRIVEN OR POWER OPERATED EQUIPMENT BE USED DIRECTLY OVER THE TRANSMISSION LINE, OR WITHIN 2' FROM THE EDGE OF THE PIPE. EQUIPMENT SHALL NOT REMAIN STATIONARY OVER THE PIPELINE. A PG&E TRANSMISSION PERSONNEL SHALL BE ON STANDBY WHEN CONSTRUCTION IS TO TAKE PLACE WITHIN 10' OF THE EXISTING TRANSMISSION LINE. STAMP AN "S" INTO CURB FACE OVER EACH SEWER LATERAL 0 MULTIPLE UTILITY TRENCH (L SEWER MAIN 4' R. 5 � � R. 4'. ITYP. 5' WATERUNE TYP¢. FINISHED STREET Q m 3 GRADE 3 IF 1 60" 36" TYP. �k TO 7' MAX. oa TYP. — O 19; MIN. 1 MIN' ON DEEP SEWER, SLOPE LATERALS �� ` = '"'--- ,-- f SET LATERAL PROVIDING PROPER TO LOT LINE SO THAT THE END OF CLEARANCE UNDER WATERLINE AND LATERAL IS WITHIN REQUIRED UTILITY TRENCHES TOLERANCE. DETAIL TYPICAL SEWER LATERAL INSTALLATION �k FOR SHALLOW INSTALLATION OF SEWER LATERALS FROM SHALLOW SEWER MAINS, THE SEWER LATERALS MUST CROSS OVER THE WATER OR UTILITY TRENCH. THESE INSTALLATIONS MUST RECEIVE SPECIAL TREATMENT FOR LATERALS WHEN CROSSING OVER THE WATERMAIN. A SEWER LATERAL CROSSING ABOVE A WATER MAIN SHALL BE CONSTRUCTED OF A CONTINUOUS 20' SECTION OF CLASS 200 (DR 14 PER AWWA C900) PLASTIC PIPE OR EQUIVALENT, CENTERED ON THE PIPE BEING CROSSED. NOTE: CONTRACTOR TO VERIFY THAT WATER MAIN AND SEWER LATERAL CROSSINGS ARE IN CONFORMANCE WITH CALIFORNIA HEALTH CODE REQUIREMENTS. TO7'MAX. * SURFACE MARKER FOR LATERALS PER C.O.B. STD. S--1 VICINITY MAP NO SCALE CITY OF BAKERSFIE.LD ILI ucolj"L PRIVATE SEWER AND STORM DRAIN, PLANS FOR TRACT 7302 UNIT 3 & 4 "NOTICE OF COMPLETION WILL NOT BE ISSUED UNTIL THE SEWER ON HIGHGATE GREENS DRIVE IS CONNECTED TO AN EXISTING SEWER LINE. (SEWER MUST BE A LIVE SEWER LINE) INDEX OF SHEETS SHEET TITLE 1. COVER SHEET 2. NOTES 3. HIGHGATE GREENS DRIVE 4. LADBROOK WAY & WHINFELL COURT NOTE: 1. PRIOR TO THE START OF ANY PHASE OF CONSTRUCTION, THE CITY CONSTRUCTION INSPECTION DEPARTMENT SHALL BE GIVEN 24 HOURS NOTICE. TELEPHONE 326--3049 NO CITY INSPECTIONS WILL BE GIVEN FOR THE WORK IN THIS AREA UNTIL A STREET PERMIT WITH APPROPRIATE SECURITY AND INSURANCE HAS BEEN OBTAINED. 2. ALL FACILITIES CONSTRUCTED PER THESE PLANS ARE TO BE PRIVATELY MAINTAINED. 3. ALL MATERIALS SUPPLIED FOR THIS PROJECT WILL REQUIRE A CERTIFICATE OF COMPLIANCE STATING THAT THE REQUIREMENTS & STANDARDS SET FORTH BY THE CITY OF BAKERSFIELD HAVE BEEN MET. ENGINEER'S STATEMENT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECTION AND TO ` THE BEST OF MY KNOWLEDGE AND BELIEF COMPLY WITH CITY OF BAKERSFIELD ORDINANCES, STANDARDS, AND DESIGN CRITERIA AND INCLUDE ALL IMPROVEMENT REQUIREMENTS OF THE ADVISORY AGENCY OR OTHER REVIEW BOARD. I AM RESPONSIBLE FOR ALL CALCULATIONS AND DRAWINGS ON THESE PLANS AND I ANY ERRORS, OMISSIONS, OR "VIOLATIONS OF THOSE ORDINANCES, STANDARDS AND DESIGN CRITERIA SHALL BE CORRECTED DURING CONSTRUCTION AND SUCH CORRECTIONS SHALL BE REFLE ON CORS CTED PLANS ITTED TO THE CITY ENGINEER. APPROVED BY: ROGER A. MCI TOSH R.C.E. 33322 DATE IN ACCORDANCE WITH THE CONDITIONS OF THE VESTING TENTATIVE MAP, THE IMPROVEMENT PLANS HAVE BEEN REVIEWED BY THE CITY OF BAKERSFIELD PUBLIC WORKS DEPARTMENT. ALL IMPROVEMENTS HEREIN ARE PRIVATE AND ARE TO BE PRIVATELY MAINTAINED. APPROVED : NICOLAS FIDLER, PUBLIC WORKS DIRECTOR DATE R.C.E. NO. 61069 EXP. 12-31-18 ASSISTANT PUBLIC WORKS DIRECTOR BASIS OF BEARINGS: THE BEARING OF N01'02'20"E SHOWN FOR THE EAST LINE SECTION 10, T. 30 S., R. 26 E. AS SHOWN ON RECORD OF SURVEY, BOOK 25, PAGE 49 WAS USED AS THE BASIS OF BEARING SHOWN HEREON. BENCHMARK USED: TOP OF CONCRETE MONUMENT IN LAMPHOLE AT THE INTERSECTION OF MING AVENUE AND ALLEN RD., ALSO BEING THE NORTHWEST CORNER OF SECTION 12, T.30S., R.26E., m 0 N 0 CD Z Qf w w z CD Z: w U e C7 Z 0 z J LEGEND: STOCKDALE LEGEND (CONT.): T. 30 S., a R. 26 E. y%y 0 a 0 0 2 PROJECT Sl TE Z�. A REVIATIONS W ® CONSTRUCT STORM DRAIN LINE PER CITY STANDARDS MING AVENUE FL FLOWUNE PA PROPERTY UNE + 0 to 11 rLANE 0RL CL Z E.P. EDGE OF PAVEMENT ® CONSTRUCT STORM DRAIN MANHOLE TYPE "A" PER �cn � ELEVATION TP TOP OF PIPE C.O.B. STD. SW -4 & SW -5. WH15 O d MH MANHOLE FC FINISHED CONCRETE" 2 SUMMARY OF IMPROVEMENTS CB 14 8 13 m c OUTHERN PACIFIC RAILROAD JUNCTION BOX A.P. ANGLE POINT VICINITY MAP NO SCALE CITY OF BAKERSFIE.LD ILI ucolj"L PRIVATE SEWER AND STORM DRAIN, PLANS FOR TRACT 7302 UNIT 3 & 4 "NOTICE OF COMPLETION WILL NOT BE ISSUED UNTIL THE SEWER ON HIGHGATE GREENS DRIVE IS CONNECTED TO AN EXISTING SEWER LINE. (SEWER MUST BE A LIVE SEWER LINE) INDEX OF SHEETS SHEET TITLE 1. COVER SHEET 2. NOTES 3. HIGHGATE GREENS DRIVE 4. LADBROOK WAY & WHINFELL COURT NOTE: 1. PRIOR TO THE START OF ANY PHASE OF CONSTRUCTION, THE CITY CONSTRUCTION INSPECTION DEPARTMENT SHALL BE GIVEN 24 HOURS NOTICE. TELEPHONE 326--3049 NO CITY INSPECTIONS WILL BE GIVEN FOR THE WORK IN THIS AREA UNTIL A STREET PERMIT WITH APPROPRIATE SECURITY AND INSURANCE HAS BEEN OBTAINED. 2. ALL FACILITIES CONSTRUCTED PER THESE PLANS ARE TO BE PRIVATELY MAINTAINED. 3. ALL MATERIALS SUPPLIED FOR THIS PROJECT WILL REQUIRE A CERTIFICATE OF COMPLIANCE STATING THAT THE REQUIREMENTS & STANDARDS SET FORTH BY THE CITY OF BAKERSFIELD HAVE BEEN MET. ENGINEER'S STATEMENT THESE PLANS AND SPECIFICATIONS WERE PREPARED BY ME OR UNDER MY DIRECTION AND TO ` THE BEST OF MY KNOWLEDGE AND BELIEF COMPLY WITH CITY OF BAKERSFIELD ORDINANCES, STANDARDS, AND DESIGN CRITERIA AND INCLUDE ALL IMPROVEMENT REQUIREMENTS OF THE ADVISORY AGENCY OR OTHER REVIEW BOARD. I AM RESPONSIBLE FOR ALL CALCULATIONS AND DRAWINGS ON THESE PLANS AND I ANY ERRORS, OMISSIONS, OR "VIOLATIONS OF THOSE ORDINANCES, STANDARDS AND DESIGN CRITERIA SHALL BE CORRECTED DURING CONSTRUCTION AND SUCH CORRECTIONS SHALL BE REFLE ON CORS CTED PLANS ITTED TO THE CITY ENGINEER. APPROVED BY: ROGER A. MCI TOSH R.C.E. 33322 DATE IN ACCORDANCE WITH THE CONDITIONS OF THE VESTING TENTATIVE MAP, THE IMPROVEMENT PLANS HAVE BEEN REVIEWED BY THE CITY OF BAKERSFIELD PUBLIC WORKS DEPARTMENT. ALL IMPROVEMENTS HEREIN ARE PRIVATE AND ARE TO BE PRIVATELY MAINTAINED. APPROVED : NICOLAS FIDLER, PUBLIC WORKS DIRECTOR DATE R.C.E. NO. 61069 EXP. 12-31-18 ASSISTANT PUBLIC WORKS DIRECTOR BASIS OF BEARINGS: THE BEARING OF N01'02'20"E SHOWN FOR THE EAST LINE SECTION 10, T. 30 S., R. 26 E. AS SHOWN ON RECORD OF SURVEY, BOOK 25, PAGE 49 WAS USED AS THE BASIS OF BEARING SHOWN HEREON. BENCHMARK USED: TOP OF CONCRETE MONUMENT IN LAMPHOLE AT THE INTERSECTION OF MING AVENUE AND ALLEN RD., ALSO BEING THE NORTHWEST CORNER OF SECTION 12, T.30S., R.26E., m 0 N 0 CD Z Qf w w z CD Z: w U e C7 Z 0 z J LEGEND: LEGEND (CONT.): ELEV = 367.96' (NAND 88 DATUM} A REVIATIONS ------- ® CONSTRUCT STORM DRAIN LINE PER CITY STANDARDS FL FLOWUNE PA PROPERTY UNE CL CENTERLINE E.P. EDGE OF PAVEMENT ® CONSTRUCT STORM DRAIN MANHOLE TYPE "A" PER ELEV ELEVATION TP TOP OF PIPE C.O.B. STD. SW -4 & SW -5. MH MANHOLE FC FINISHED CONCRETE" " , SUMMARY OF IMPROVEMENTS CB CATCH BASIN R/W RIGHT -OF --WAY ® CONSTRUCT TYPE .A CATCH BASIN NTH 3.5 OPENING PER JB JUNCTION BOX A.P. ANGLE POINT C.O.B. STD. D-14, UNLESS NOTED OTHERWISE. ELEV ELEVATION C&G CURB AND GUTTER ---- • S CONSTRUCT SEWER UNE PER CITY STANDARDS SEWER IMPROVEMENTS PHASES PHASE 3 PHASE 4 TOTAL T.O.M. TOP OF MANHOLE T.O.C. TOP OF CLEANOUT O CONSTRUCT SEWER TYPE "A" PER C.O.B. STD. SW 6" SEWER LINE LF 191 318 509 SCP STREET CONSTRUCTION PLAN EX. EXISTING MANHOLE -4 8" SEWER LINE TEMP. TEMPORARY INV. INVERT AND SW -5. LF 1271 427 1698 C CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. SW -6. 0 4" LATERALS LF 405 629 1034 — - - -- - - -- - - -- TRACT BOUNDARY STANDARD CLEANOUT EA 1 3 4 - - - CENTERLINE�---PIPE SIZE STANDARD MANHOLE EA 6 3 9 UNIT BOUNDARY 4"W UTILITY W -WATER D -DRAIN G -GAS S -SEWER TEMP. CLEANOUT EA 1 - 1 EXISTING WATER w PROPOSED WATER - REFER WATER PLANS. SECTION DESIGNATION: SECTION LETTER Know What's below. STORM DRAIN IMPROVEMENTS PHASES PHASE 3 PHASE 4 TOTAL S EXISTING SEWER — w — — _ A18" STORM DRAIN LINE LF 220 — 220 Call before you dig. - - o EXISTING STORM DRAIN 2 CATCH BASINS EA 2 — 2 SHEET WHERE SECTION IS SHOWN STANDARD MANHOLE EA 1 - 1 1 7-71 f 17 p h I k d �IIIIIIIII STANDARD NOTES 1. GENERAL CONTRACTOR WILL FURNISH ALL MATERIALS, TOOLS, LABOR, EQUIPMENT AND SUPERVISION NECESSARY TO COMPLETE INSTALLATION. UNDERGROUND SERVICE ALERT (USA) SHALL BE NOTIFIED AT LEAST 2 WORKING DAYS BEFORE CONSTRUCTION. TELEPHONE 1-800-227-2600. CONTRACTOR TO CALL FOR USA LOCATE AND POTHOLE ALL MARKED UTILITIES THAT CROSS OR ARE WITHIN 5' HORIZONTAL DISTANCE OF SEWER AND STORM DRAIN LINES. VERTICAL AND HORIZONTAL LOCATION SHALL BE ASCERTAINED BY THE CONTRACTOR AHEAD OF ANY EXCAVATIONS TO VERIFY THAT THE PROPOSED DESIGN DOES NOT CONFLICT WITH ANY UTILITIES. IN THE EVENT A CONFLICT EXISTS THE ENGINEER SHALL BE NOTIFIED IN ORDER TO REDESIGN THE ALIGNMENT. IF RELOCATION OF EXISTING UTILITIES iS DEEMED NECESSARY THE CONTRACTOR SHALL BE COMPENSATED FOR INSTRUCTED RELOCATION. IF REDESIGN OF THE ALIGNMENT REQUIRES ADDITIONAL FITTINGS, PIPE OR EXCAVATION THE CONTRACTOR SHALL BE COMPENSATED FOR REVISION. IN THE EVENT A UTILITY IS DAMAGED THE CONTRACTOR SHALL BE WHOLLY RESPONSIBLE FOR ITS REPAIR. CONTRACTOR SHALL VERIFY LOCATIONS AND ELEVATIONS OF EXISTING SEWER LINES THAT THE NEW SYSTEM TIES INTO PRIOR TO TRENCHING. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER SO THAT ANY NECESSARY ADJUSTMENTS MAY BE MADE. UTILITIES SHALL BE THOROUGHLY RESEARCHED AND LOCATED BY CONTRACTOR PRIOR TO TRENCHING. CROSSING UTILITIES SHALL BE DAYUGHTED AND CHECKED FOR GRADE, BY CONTRACTOR PRiOR TO TRENCHING. ALL EXISTING PAVING AND SURFACING REMOVED, DAMAGED OR UNDERCUT SHALL BE REPLACED IN ACCORDANCE LITH THE CITY OF BAKERSFIELD STANDARD DRAWING ST -6, EXCEPT AS NOTED ON PLANS. ANY ITEMS IN THE PUBLIC RIGHT—OF—WAY THAT ARE DAMAGED OR DO NOT MEET CURRENT STANDARDS SET BY PUBLIC WORKS WILL REQUIRE AND/OR UPGRADING AS PER CITY ENGINEER. ALL EXISTING IMPROVEMENTS, (CURB, GUTTER, SIDEWALK, CROSS GUTTER, FENCES, ETC.) THAT ARE REMOVED/DAMAGED/UNDERCUT SHALL BE REPAIRED OR REPLACED AS DIRECTED BY THE CITY ENGINEER. NOTE TO STAMP AN 'S' INTO CURB FACE OVER EACH SEWER LATERAL 2. STANDARD DETAILS THE FOLLOWING CITY OF BAKERSFiELD STANDARDS SHALL BE CONSIDERED PART OF THESE PLANS: D-14, D-16, D-18 SW -1, SW -2, SW -3, SW -4, SW -5, SW -6, SW -9, SW -11, ST -1, ST -2, ST -3, ST -6, ST -13, ST -14, ST -18, ST -22 3. VCP INSTALLATION MATERIALS : THE PiPE AND FITTINGS SHAD_ BE EXTRA STRENGTH VITRIFIED CLAY CONFORMING TO CURRENT ASTM SPECIFICATION C-700 AND SHALL BE INSTALLED IN CONFORMANCE WITH THE PROVISIONS OF SECTION 71 OF THE STANDARD SPECIFICATIONS OF THE STATE OF CALIFORNIA, DEPARTMENT OF TRANSPORTATION, CURRENT EDITION AND THE CURRENT ASTM SPECIFICATIONS C-12. JOINTS : THE PIPE AND FITTINGS SHALL HAVE A SOCKET END AND A SPIGOT END WITH .COMPRESSION JOINTS CONFORMING WITH THE CURRENT ASTM SPECIFICATION C-425. THE PIPE AND FITTINGS FOR 6", 8", 10", AND 12" SANITARY SEWER MAINS MAY BE PLAIN—END WITH COMPRESSION COUPLINGS CONFORMING WITH THE CURRENT ASTM SPECIFICATION C-425. EXCEPTING THAT A STAINLESS STEEL SHEAR RING AS MANUFACTURED BY MISSION CLAY PRODUCTS CORPORATION FOR THEIR "MAINLINE" BANDSEAL COMPRESSION COUPLING, OR APPROVED EQUAL, SHALL BE .REQUIRED. THE PIPE AND FITTINGS FOR PRIVATE SANITARY SEWER HOUSE OR BUILDING LATERALS MAY BE PLAIN—END WITH COMPRESSION COUPLINGS CONFORMING WITH THE CURRENT ASTM SPECIFICATION C-425. (STAINLESS STEEL SHEAR RINGS ARE NOT REQUIRED) 4. ABS PIPE INSTALLATION MATERIALS : PIPE AND FITTINGS SHALL MEET THE REQUIREMENTS OF THE CURRENT ASTM SPECIFICATIONS D-2680 AND D-2751. PIPE AND FITTINGS SHALL BE HOMOGENEOUS THROUGH OUT AND FREE FROM CRACKS, HOLES, FOREIGN INCLUSIONS OR OTHER INJURIOUS DEFECTS. FITTINGS SHALL BE INJECTION MOLDED AND SHALL BE INSTALLED IN UNE ON NEW PIPELINES; CUT—IN FITTINGS ARE NOT PERMITTED. JOINTS : USE ONLY SOLVENT WELDED JOINTS. THE ASSEMBLY OF JOINTS SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE ABS PIPE CONNECTS TO VCP, USE COUPLINGS APPROVED BY THE CITY OF BAKERSFIELD. INSTALLATION : PiPE AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT ASTM SPECIFICATION D-2321. ONLY CLASS 1, 11, AND 111 EMBEDMENT MATERIALS WILL BE CONSIDERED SUITABLE. 5. PVC PIPE INSTALLATION MATERIALS : PIPE AND FITTINGS SHALL MEET THE REQUIREMENTS OF THE CURRENT ASTM SPECIFICATION D-3034 FOR SDR35. PIPE AND FITTINGS SHALL BE HOMOGENEOUS THROUGHOUT AND FREE FROM CRACKS, HOLES, FOREIGN INCLUSIONS OR OTHER INJURIOUS DEFECTS. FITTINGS SHALL BE INJECTION MOLDED AND SHALL BE INSTALLED IN LINE ON NEW PIPELINES; CUT—IN FITTINGS ARE NOT PERMITTED. JOINTS : USE ONLY ELASTOMERIC GASKET JOINTS. THE ASSEMBLY OF JOINTS SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDA11ONS WHERE PVC PIPE CONNECTS TO VCP PIPE, USE COUPLINGS APPROVED BY THE CITY OF BAKERSFIELD. INSTALLA11ON : PIPE AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT ASTM SPECIFICATION D-2321. ONLY CLASS 1, II, AND IiI EMBEDMENT MATERIALS WILL BE CONSIDERED SUITABLE. 6. REINFORCED CONCRETE PIPE WITH PVC LINING. REINFORCED CONCRETE PIPE WITH PVC LINING SHALL MEET THE FOLLOWING REQUIREMENTS: 1.A. MATERIALS. REINFORCED CONCRETE PIPE (RCP) SHALL BE EITHER CLASS IV OR CLASS V WITH WALLS "B" OR V. RCP SHALL MEET ASTM C 76 FOR STRENGTH, ASTM C 361 OR AWWA C302 EXCEPT TEST PRESSURE SHALL BE 5 PSI FOR RUBBER GASKETS, AND LINER TESTS IN ACCORDANCE WITH THE FOLLOWING PARAGRAPHS. PIPE SHALL BE WET CAST, VIBRATED AND STEAM OR WATER CURED. JOINTS SHALL BE BELL AND SPIGOT DESIGN WITH A CONTAINED 0—RING GASKET. PVC LINER SHALL BE CAST INTO THE WALL OF THE RCP AND SHALL COVER 360' OF THE PIPE. ALL WORK FOR AND IN CONNECTION WITH THE INSTALLATION OF THE LINING IN CONCRETE PIPE AND FIELD SEALING AND WELDING OF JOINTS SHALL BE DONE IN STRICT CONFORMITY WITH ALL APPLICABLE SPECIFICATIONS, INSTRUCTIONS AND RECOMMENDATIONS OF THE LINING MANUFACTURER. LINER SHALL MEET THE FOLLOWING REQUIREMENTS. 1.B. PHYSICAL PROPERTIES OF LINER. ALL PLASTIC LINER PLATE SHEETS, WELDING STRIPS AND OTHER ACCESSORY ITEMS, SHALL HAVE THE FOLLOWING PHYSICAL PROPERTIES MEN TESTED AT 77-F t5 (25-C t3 ). PR.4.P INITIAL (PAR, 1,G) TENSILE STRENGTH 2200 PSI MIN. 2100 PSI MIN. (15 MPA MIN.) (14.5 MPA MIN.) ELONGATION AT BREAK 2007. MIN. 200% MIN. SHORE DUROMETER, TYPE D 1—SEC. 50-60 t5 (WITH RESPECT TO INITIAL TEST RESULT) 10—SEC. 35-50 t5 WEIGHT CHANGE t1.5 TENSILE SPECIMENS SHALL BE PREPARED AND TESTED iN ACCORDANCE WITH ASTM D412 USING DIE B. WEIGHT CHANGE SPECIMENS SHALL BE 1—INCH (25—MM) BY 3—INCH (75—MM) SAMPLES. SPECIMENS FOR TESTING OF INITIAL PHYSICAL PROPERTIES MAY BE TAKEN FROM LINER PLATE SHEET AND WIELDING STRIP AT ANY TiME PRIOR TO FINAL ACCEPTANCE OF THE WORK. LINER PLATE LOCKING EXTENSIONS EMBEDDED IN CONCRETE SHALL WITHSTAND A TEST PULL OF AT LEAST 100 POUNDS PER LINEAR INCH (1800 KG/M), APPLIED PERPENDICULARLY TO THE CONCRETE SURFACE FOR A PERIOD OF ONE MINUTE, WITHOUT RUPTURE OF THE LOCKING EXTENSIONS OR WITHDRAWAL FROM EMBEDMENT. THIS TEST SHALL BE MADE AT A TEMPERATURE OF 70° - 80' F(21- — 27' C) INCLUSIVE ALL PLASTIC LINER PLATE SHEETS, INCLUDING LOCKING EXTENSIONS, ALL JOINT, CORNER AND WELDING STRIPS SHALL BE FREE OF CRACKS, CLEAVAGES OR OTHER DEFECTS ADVERSELY AFFECTING THE PROTECTIVE CHARACTERISTICS OF THE MATERIAL. THE ENGINEER MAY AUTHORIZE THE REPAIR OF SUCH DEFECTS BY APPROVED METHODS. THE LINING SHALL HAVE GOOD IMPACT RESISTANCE, SHALL BE FLEXIBLE AND SHALL HAVE AN ELONGATION SUFFICIENT TO BRIDGE UP TO 1/4 -INCH (6 MM) SETTLING CRACKS, WHICH MAY OCCUR IN THE PIPE OR IN THE JOINT AFTER INSTALLATIONS, WITHOUT DAMAGE TO THE LINING. 1.C. CHEMICAL RESISTANCE OF LINER.* AFTER CONDITIONING TO CONSTANT WEIGHT AT 110 F(43 C), TENSILE SPECIMENS AND WEIGHT CHANGE SPECIMENS SHALL BE EXPOSED TO THE FOLLOWING SOLUTIONS FOR A PERIOD OF 112 DAYS AT 7T F t5 (25' C t3 ). AT 28—DAY INTERVALS, TENSILE SPECIMENS AND WEIGHT CHANGE SPECIMENS SHALL BE REMOVED FROM EACH OF THE CHEMICAL SOLUTIONS AND TESTED IN ACCORDANCE WITH SECTION 7-2.03(1.B) PARA. 2 ABOVE. IF ANY SPECIMEN FAILS TO MEET THE 112 --DAY REQUIREMENTS BEFORE COMPLETION OF THE 112—DAY EXPOSURE, THE MATERIAL WILL BE SUBJECT TO REJECTION. CHEMICAL SOLUTION SULFURIC ACID SODIUM HYDROXIDE AMMONIUM HYDROXIDE NITRIC ACID FERRIC CHLORIDE 1% SOAP DETERGENT (LINEAR ALKYL BENZYL SULFONATE OR LAS BACTERIOLOGICAL CONCENTRATION 20%** 5% 57** 170** 1% 0.1% 0.1% BOD NOT LESS THAN 700 PPM *THIS iS TO BE USED AS A PRE—QUALIFICATION TEST AND WHEN MATERIAL FORMULATIONS ARE CHANGED. **VOLUMETRIC PERCENTAGES OF CONCENTRATED C.P. GRADE REAGENTS. 1.D. DETAILS AND DIMENSIONS OF LINER SHEETS. LINER SHEETS SHALL BE A MINIMUM OF 0.065 INCH (1.65 MM) IN THICKNESS. LOCKING EXTENSIONS OF THE SAME MATERIAL AS THAT OF THE LINER SHALL BE INTEGRALLY EXTRUDED WITH THE SHEET. LE. INSTALLATION OF LINING. INSTALLATION OF THE LINING, INCLUDING PREHEATING OF SHEETS IN COLD WEATHER AND THE WELDING OF ALL JOINTS, SHALL BE DONE IN ACCORDANCE WITH THE RECOMMENDA11ONS OF THE LINER MANUFACTURER. COVERAGE OF THE LINING SHALL NOT BE LESS THAN THE MINIMUM SHOWN ON THE PLANS. THE LINING SHALL BE INSTALLED WITH THE LOCKING EXTENSIONS RUNNING PARALLEL WiTH THE LONGITUDINAL AXIS OF THE PIPE. THE LINING SHALL BE HELD SNUGLY IN PLACE AGAINST INNER FORMS. LOCKING EXTENSION SHALL TERMINATE NOT MORE THAN 1-1/2 INCHES (38 MM) FROM THE END OF THE INSIDE SURFACE OF THE PiPE SECTION. JOINT FLAPS WREN USED SHALL EXTEND APPROXIMATELY 4 INCHES (100 MM) BEYOND THE END OF THE INSIDE SURFACE. CONCRETE POURED AGAINST LINING SHALL BE VIBRATED, SPADED OR COMPACTED IN A CAREFUL MANNER SO AS TO PROTECT THE LINING AND PRODUCE A DENSE, HOMOGENOUS CONCRETE, SECURELY ANCHORING THE LOCKING EXTENSIONS INTO THE CONCRETE. IN REMOVING FORMS, CARE SHOULD BE TAKEN TO PROTECT THE LINING FROM DAMAGE. SHARP INSTRUMENTS SHALL NOT BE USED TO PRY FORMS FROM LINED SURFACES. WHEN FORMS ARE REMOVED, ANY NAILS THAT REMAIN IN THE LINING SHALL BE PULLED, WITHOUT TEARING THE LINING, AND THE RESULTING HOLES CLEARLY MARKED. ALL NAIL AND TIE HOLES AND ALL CUT, TORN AND SERIOUSLY ABRADED AREAS IN THE LINING SHALL BE PATCHED. PATCHES MADE ENTIRELY WITH WELDING STRIP SHALL BE FUSED TO THE LINER OVER THE ENTIRE PATCH AREA. LARGER PATCHES MAY CONSIST OF SMOOTH LINER SHEET APPLIED OVER THE DAMAGED AREA WITH ADHESIVE. ALL EDGES MUST BE COVERED WITH MELDING STRIP FUSED TO THE PATCH AND THE SOUND LINING ADJOINING THE DAMAGED AREA. HOT JOINT COMPOUNDS, SUCH AS COAL TAR, SHAD_ NOT BE POURED OR APPLIED TO THE LINING. THE CONTRACTOR SHALL TAKE ALL NECESSARY MEASURES TO PREVENT DAMAGE TO INSTALLED LINING FROM EQUIPMENT AND MATERIALS USED IN OR TAKEN THROUGH THE WORK. 1.F APPLICATION TO CONCRETE PIPE — SPECIAL REQUIREMENTS. THE LINING SHAD_ BE SET FLUSH WITH THE INNER EDGE OF THE BELL OR SPIGOT END OF A PIPE SECTION AND SHALL EXTEND TO THE OPPOSITE END OR TO APPROXIMATELY 4 INCHES (100 MM) BEYOND THE OPPOSITE END DEPENDING UPON THE TYPE OF LINING JOINT TO BE MADE WITH THE ADJOINING CONCRETE PIPE. WHEREVER CONCRETE PIPE OR CAST—iN—PLACE STRUCTURES PROTECTED WITH LINING, JON STRUCTURES NOT SO LINED (SUCH AS BRICK STRUCTURES, CONCRETE PIPE OR CAST—IN—PLACE STRUCTURES WITH CLAY LINING OR CLAY PIPE), THE LINING SHALL BE EXTENDED OVER AND AROUND THE END OF THE PIPE AND BACK INTO THE STRUCTURE FOR NOT LESS THAN 4 INCHES (100 MM). THIS PROTECTING CAP MAY BE MOLDED OR FABRICATED FROM THE LINING MATERIAL BUT NEED NOT BE LOCKED INTO THE PIPE. WHERE A PIPE LATERAL (NOT OF PLASTIC LINED CONCRETE) IS INSTALLED THROUGH LINED CONCRETE PiPE, THE SEAL BETWEEN THE LINED PORTION AND THE LATERAL SHALL BE PER THE MANUFACTURER'S RECOMMENDATIONS. LINED CONCRETE PIPE MAY BE CURED BY STANDARD CURING METHODS. CARE SHALL BE EXERCISED IN HANDLING, TRANSPORTING AND PLACING LINED PIPE TO PREVENT DAMAGE TO THE LINING. NO INTERIOR HOOKS OR SLINGS SHALL BE USED iN LIFTING PIPE. ALL HANDLING OPERATION SHALL BE DONE WITH AN EXTERIOR SUNG OR WITH A SUITABLE FORK UFT. ON PIPE HAVING A 360' LINER COVERAGE, THE LONGITUDINAL EDGES OF THE SHEET SHAD_ BE BUTT WELDED. WHEN PiPE TUBES ARE FURNISHED, THESE ARE SHOP—WELDED JOINTS. NO PIPE WITH DAMAGED LINING WILL BE ACCEPTED UNTIL THE DAMAGE HAS BEEN REPAIRED TO THE SATISFACTION OF THE ENGINEER. 1.G. FIELD JOINTS iN LINING FOR CONCRETE PIPE. THE JOINT BETWEEN SEC11ONS OF LINED PIPE SHALL BE PREPARED IN THE FOLLOWING MANNER: IF REQUIRED, THE INSIDE JOINT SHALL BE FILLED AND CAREFULLY POINTED WITH CEMENT MORTAR IN SUCH A MANNER THAT THE MORTAR SHALL NOT, AT ANY PONT, EXTEND INTO THE PIPE BEYOND THE STRAIGHT LINE CONNECTING THE SURFACES OF THE ADJACENT PIPE SECTIONS. PIPE JOINTS MUST BE DRY BEFORE LINING JOINTS ARE MADE. ALL MORTAR AND OTHER FOREIGN MATERIAL SHALL BE REMOVED FROM LINING SURFACES ADJACENT TO THE PIPE JOINT, LEAVING THEM CLEAN AND DRY. FIELD JOINTS IN THE LINING AT PIPE JOINTS MAY BE EITHER OF THE FOLLOWING DESCRIBED TYPES: TYPE P-1: THE JOINT SHALL BE MADE WITH A SEPARATE 4—INCH (100—MM) JOINT STRIP AND TWO MELDING STRIPS. THE 4—INCH (100 --MM) JOINT STRiP SHALL BE CENTERED OVER THE JOINT, HEAT—SEALED TO THE LINING, THEN WELDED ALONG EACH EDGE TO ADJACENT LINER SHEETS WITH A 1—INCH (25—MM) WELD STRiP. THE 4—INCH (100—MM) JOINT STRIP SHALL LAP OVER EACH SHEET A MiNIMUM OF 1/2 INCH (13 MM). TYPE P-2: THE JOINT SHALL BE MADE WITH A JOINT FLAP WITH LOCKING EXTENSIONS REMOVED AND EXTENDING APPROXIMATELY 4 INCHES (100 MM) BEYOND THE PiPE END. THE JOINT FLAP SHALL OVERLAP THE LINING IN THE ADJACENT PIPE SECTION A MiNIMUM OF 1/2 INCH (13 MM) AND BE HEAT—SEALED IN PLACE PRIOR TO WELDING. THE FIELD JOINT SHALL BE COMPLETED BY WELDING THE FLAP TO THE LINING OF THE ADJACENT PIPE USING 1—INCH (25—MM) WELD STRIP. CARE SHALL BE TAKEN TO PROTECT THE FLAP FROM DAMAGE. EXCESSIVE TENSION AND DISTORTION IN BENDING BACK THE FLAP TO EXPOSE THE PIPE JOINT DURING LAYING AND JOINT MORTARING SHALL BE AVOIDED. AT TEMPERATURES BELOW 50 F(10 C), HEATING OF THE LINER MAY BE REQUIRED TO AVOiD DAMAGE. THE JOINT FLAP OR STRIP ON BEVELED PIPE SHALL BE TRIMMED TO A WIDTH (MEASURED FROM THE END OF THE SPIGOT) OF APPROXIMATELY 4 INCHES (100 MM) FOR THE EN11RE CIRCUMFERENTIAL LENGTH OF THE LINING. ALL WIELDING OF JOINTS IS TO BE IN STRICT CONFORMANCE WITH THE SPECIFICATIONS AND INSTRUCTIONS OF THE LINING MANUFACTURER. MELDING SHALL FUSE BOTH SHEETS AND MELD STRIP TOGETHER TO PROVIDE A CONTINUOUS JOINT EQUAL IN CORROSION RESISTANCE AND IMPERMEABILITY TO THE LINER PLATE. HOT—AIR WELDING TOOLS SHALL PROVIDE EFFLUENT AIR TO THE SHEETS TO BE JOINED AT A TEMPERATURE BETWEEN 500 AND 600 F (260 AND 316 C). MELDING TOOLS SHALL BE HELD APPROXIMATELY 1/2 INCH (13 MM) FROM AND MOVED BACK AND FORTH OVER THE JUNCTION OF THE TWO MATERIALS TO BE JOINED. THE WELDING TOOL SHALL BE MOVED SLOWLY ENOUGH AS THE WELD PROGRESSES TO CAUSE A SMALL BEAD OF MOLTEN MATERIAL TO BE VISIBLE ALONG BOTH EDGES AND IN FRONT OF THE WIELD STRIP. I . THE FOLLOWING SPECIAL REQUIREMENT SHALL APPLY WHEN THE LINER COVERAGE IS 360 DEGREES: WHEN GROUNDWATER IS ENCOUNTERED THE LINING JOINT SHALL NOT BE MADE UN11L PUMPING OF GROUNDWATER HAS BEEN DISCONTINUED FOR AT LEAST THREE DAYS AND NO ViSiBLE LEAKAGE IS EVIDENT AT THE JOINT. WHEN WELDING THE DOWNSTREAM SIDE OF A JOINT STRIP OR FLAP, DO NOT WELD 6 TO 8 INCHES (150 TO 200 MM) AT THE PiPE INVERT TO PROVIDE RELIEF OF POTENTIAL FUTURE GROUNDWATER BUiLD—UP. 1.H. APPLICATION TO CAST—iN—PLACE CONCRETE STRUCTURES — SPECIAL REQUIREMENTS. LINER SHEETS SHALL BE CLOSELY FITTED AND PROPERLY SECURED TO THE INNER FORMS. SHEETS SHALL BE CUT TO FIT CURVED AND WARPED SURFACES USING A MINIMUM NUMBER OF SEPARATE PIECES. UNLESS OTHERWISE SHOWN ON THE PLANS„ THE LINING SHALL BE RETURNED AT LEAST 3 INCHES (75 MM) AT THE SURFACES OF CONTACT BETWEEN THE CONCRETE STRUCTURE AND ITEMS NOT OF CONCRETE (INCLUDING MANHOLE FRAMES, GATE GUIDES, CLAY PIPE OR BRICK MANHOLES AND CLAY OR CAST IRON PiPES). THE SAME PROCEDURE SHALL BE FOLLOWED AT JOINTS WHERE THE TYPE OF PROTECTIVE LINING IS CHANGED OR THE NEW WORK IS BUILT TO JON EXISTING UNLINED CONCRETE. AT EACH RETURN, THE RETURNED LINER SHALL BE SEALED TO THE ITEM IN CONTACT WITH THE PLASTIC—LINED CONCRETE. IF THE LINER CANNOT BE SEALED WITH ADHESIVE BECAUSE OF THE JOINT AT THE RETURN BEING TOO WIDE OR ROUGH OR BECAUSE OF SAFETY REGULATIONS, THE JOINT SPACE SHALL BE DENSELY CAULKED WITH LEAD WOOL OR OTHER APPROVED CAULKING MATERIAL TO A DEPTH OF 2 INCHES (50 MM) AND FINISHED WITH A MINIMUM OF 1 INCH 925 MM) OF AN APPROVED CORROSION RESISTANT MATERIAL 1.1. TESTING AND REPAIRING DAMAGED SURFACES. AFTER THE PIPE IS INSTALLED IN THE TRENCH, ALL SURFACES COVERED WITH LINING, INCLUDING WELDS, MALL BE TESTED WITH AN APPROVED, CONTRACTOR SUPPLIED, ELECTRICAL HOLIDAY DETECTOR (TINKER & RASOR MODEL NO. AP—W WITH POWER PACK OR APPROVED EQUAL) WITH THE INSTRUMENT SET BETWEEN 18,000 AND 22,000 VOLTS. ALL WIELDS SHALL BE PHYSICALLY TESTED BY A NONDESTRUCTIVE PROBING METHOD. ALL PATCHES OVER HOLES, OR REPAIRS TO THE LINER WHEREVER DAMAGE HAS OCCURRED, SHALL BE ACCOMPLISHED IN ACCORDANCE WITH SECTION 7-2.03(1.E) PARA. 8 ABOVE. EACH TRANSVERSE WELDING STRIP WHICH EXTENDS TO A LOWER EDGE OF THE LINER WILL BE TESTED BY THE PURCHASING AGENCY. THE MELDING STRIPS SHALL EXTEND 2 INCHES (50 MM) BELOW THE LINER TO PROVIDE A TAB. A 10—POUND (5 KG) PULL WILL BE APPLIED TO EACH TAB. THE FORCE WILL BE APPLIED NORMAL TO THE FACE OF THE STRUCTURE BY MEANS OF A SPRING BALANCE. LINER ADJOINING THE WELDING STRIP WILL BE HELD AGAINST THE CONCRETE DURING APPLICATION OF THE FORCE. THE 10—POUND (5 KG) PULL WILL BE MAINTAINED IF A WELD FAILURE DEVELOPS, UNTiL NO FURTHER SEPARATION OCCURS. DEFECTIVE WELDS WILL BE RETESTED AFTER REPAIRS HAVE BEEN MADE. TABS SHALL BE TRIMMED AWAY NEATLY BY THE INSTALLER OF THE LINER AFTER THE WELDING STRIP HAS PASSED INSPECTION. INSPECTION SHALL BE MADE WITHIN 2 DAYS AFTER THE JOINT HAS BEEN COMPLETED IN ORDER TO PREVENT TEARING THE PROJECTING WELD STRIP AND CONSEQUENT DAMAGE TO THE LINER FROM EQUIPMENT AND MATERIALS USED IN OR TAKEN THROUGH THE WORK. SHOP DRAWINGS. CONTRACTOR SHALL SUBMIT MANUFACTURER INFORMATION SHOWING DIMENSIONAL, MATERIAL AND JOINT CRITERIA TO THE ENGINEER FOR REVIEW. PIPE TRENCH CLASSIFICATION. RCP CLASS IV SHALL BE INSTALLED PER ASTM TRENCH DESIGNATION 'V. RCP CLASS V SHALL BE INSTALLED PER ASTM TRENCH DESIGNATION V. PVC FOR PIPE SIZES 18" AND LESS. POLY VINYL CHLORIDE PIPE SHALL MEET THE FOLLOWING REQUIREMENTS: 1. MATERIAL. PVC PIPE SHALL MEET OR EXCEED ALL REQUIREMENTS SET FORTH iN ASTM D 3034 WITH SDR OF 35. ELASTOMERiC SEALS AND JOINTS SHALL CONFORM TO ASTM D 3212 AND ASTM F 477. 2. TESTING. MANUFACTURING TESTING METHODS SHALL CONFORM TO ASTM F-679 (T—WALL). CERTIFICATES OF COMPLIANCE SHALL BE MADE AVAILABLE TO THE ENGINEER. 3. INSTALLATION. INSTALLATION OF PIPE SHALL FOLLOW MANUFACTURER'S GUIDELINES, THESE SPECIFICATIONS AND ASTM D 2321 "UNDERGROUND INSTALLATION OF FLEXIBLE THERMOPLASTIC SEWER PIPE.". 4. FIELD TESTS. IN—FIELD PRESSURE TESTS SHALL CONFORM TO THESE SPECIFICATIONS AND THE FOLLOWING: DEFLECTION MEASUREMENT OF PVC PiPE. AFTER 30 DAYS OF INSTALLATION THE CONTRACTOR SHALL MEASURE PIPE DEFLECTION BY PULLING A GO—NO—GO 5% MANDREL.. THE MANDREL SHALL BE PULLED THROUGH THE PIPE WITH ROPE BY ONE PERSON WITHOUT MECHANICAL ADVANTAGE. THE MANDREL SHALL HAVE VANES AT LEAST AS LONG AS THE PIPE DIAMETER. THE MANDREL SHALL BE USED IN STRICT CONFORMANCE WITH PIPE AND MANDREL MANUFACTURER'S RECOMMENDATIONS. THE MANDREL DIAMETER WILL BE CALCULATED USING THE FOLLOWING FORMULA: MANDREL DIAMETER = BASE PIPE I.D. —(Y/100 X BASE PIPE I.D.) WHERE Y = ALLOWABLE DEFLECTION IN % (5%) BASE I.D. = ACTUAL INSIDE PiPE DIAMETER (PROVIDED BY PIPE MANUFACTURER) THE MANDREL SHALL HAVE AN ODD NUMBER OF VANES WITH SEVEN (7) MINIMUM. THE MINIMUM LENGTH OF THE CIRCULAR PORTION OF THE MANDREL SHALL BE EQUAL TO THE NOMINAL DIAMETER OF THE PIPE. ANY SECTION OF INSTALLED PIPE THAT FAILS THE MANDREL TEST SHALL BE EXCAVATED, RE—BACKFILLED, RECOMPACTED AND RETESTED UN11L THE MANDREL TEST CAN BE PASSED. RE—ROUNDING WILL NOT BE ALLOWED. PIPE TRENCH CLASSIFICATION. PVC PIPE SHALL BE INSTALLED PER CITY STANDARD S-39, AS MODIFIED ON THE CONTRACT PLANS. COMPACTION ABOVE THE PIPE ZONE SHALL BE AS SHOWN ON THE PLANS. 7. TRENCH EXCAVATION THE EXCAVATION OF TRENCHES FOR PIPING LAID IN THE GROUND SHALL BE IN OPEN—CUT FROM THE SURFACE OF THE GROUND EXCEPT WHERE BORING IS REQUIRED. THE TRENCHES SHALL BE OF WIDTH AS SHOWN ON STANDARD S-39 AND DETAILED SECTIONS ON THE PLANS FOR PROPER PIPE INSTALLATION. THE HOFS FOR BELLS AND FITTINGS SHALL BE EXCAVATED BY HAND, TO A WIDTH PROVIDING UNIFORM BEARING ALONG THE LENGTH OF THE PIPE. IT IS THE INTENTION OF THESE REQUIREMENTS TO PROVIDE FIRM, UNIFORM BEARING FOR THE PIPE. CONTRACTOR SHALL PROVIDE TRENCHING IN ACCORDANCE WITH THE DETAILED SECTIONS PROVIDED IN THE PLANS. SELECTION OF TRENCH TYPES WILL BE AS REQUIRED BY THE TYPES OF PIPE SELECTED FOR CONSTRUCTION. STORM DRAiN AND UTILITY CONDUIT INSTALLATIONS SHALL MEET CITY STANDARD S-39. TRENCH LINES SHALL MEET ALL FEDERAL AND STATE SAFETY REQUIREMENTS. 8. BRACING AND SHORING EXCAVATION SHALL BE SUPPORTED AS SET FORTH IN THE RULES, ORDERS, AND REGULATIONS OF THE STATE DIVISION OF INDUSTRIAL SAFETY. IF THE CONTRACTOR DESIRES TO DEVIATE FROM THE SAFETY ORDERS, HE SHALL SUBMIT DATA BY A REGISTERED CIVIL ENGINEER TO THE STATE DIVISION OF INDUSTRIAL SAFETY, JUSTIFYING THE ALTERNATE PROCEDURES TO BE USED. FAILURE TO COMPLY WITH ANY OF THESE RULES, ORDERS AND REGULATIONS SHALL BE SUFFICIENT CAUSE FOR THE STATE DIVISION TO IMMEDIATELY SUSPEND ALL WORK. COMPENSATION FOR LOSSES INCURRED BY THE CONTRACTOR BY SUCH AN EMERGENCY SUSPENSION SHALL NOT BE ALLOWED. DURING BACKFILLING, THE BOTTOM OF THE SHORING SHALL BE KEPT ABOVE THE LEVEL OF THE BACKFILL AT ALL TIMES. SECTION 6422 OF THE CALIFORNIA LABOR CODE REQUIRES THE CONTRACTOR TO SUBMIT TO THE ENGINEER A DETAILED PLAN, DRAWING THE DESIGN OF SHORING, BRACING, SLOPING OR OTHER PROVISIONS TO BE MADE BY THE CONTRACTOR FOR THE PURPOSE OF WORKER PROTECTION FROM THE HAZARD OF CAVING GROUND DURING THE EXCAVATION OF TRENCHES NECESSARY FOR THE CONSTRUCTION OF THE PROJECT. IF SUCH PLAN VARIES FROM THE SHORING SYSTEM STANDARD ESTABLISHED BY THE CONSTRUCTION SAFETY ORDERS, THE PLANS SHALL BE PREPARED AND CERTIFIED BY A REGISTERED CiViL OR STRUCTURAL ENGINEER; HOWEVER, USE OF SYSTEMS THAT ARE LESS EFFECTIVE THEN THOSE REQUIRED BY THE CONSTRUCTION SAFETY ORDERS IS PROHIBITED ON THIS PROJECT. 9. TRENCH BACKFILL TRENCHES SHALL NOT BE LEFT OPEN FARTHER THAN THREE HUNDRED (300) FEET IN ADVANCE OF PIPE LAYING OPERATIONS OR TWO HUNDRED (200) FEET TO THE REAR THEREOF, UNLESS OTHERWISE PERMITTED BY THE ENGINEER. ALL WORK SHALL CONFORM TO THE APPLICABLE SECTIONS OF THE STANDARD SPECIFICATIONS, DATED JULY, 1992. BEDDING CLASS SHALL BE AS SPECIFIED IN THE PIPE OPTIONS. STORM DRAIN AND U11UTY CONDUIT INSTALLATIONS SHAD_ BE IN ACCORDANCE WITH CITY STANDARD ST -22, EXCEPT THAT COMPACTION SHALL BE NO LESS THAN NINETY PERCENT (907.) UP TO THIRTY INCHES (30") FROM FINISHED GRADE. BACKFILL MATERIALS IN THE PIPE ZONE SHALL BE PLACED IN LAYERS NOT TO EXCEED TWELVE (12) INCHES SIMULTANEOUSLY, ON EACH SiDE OF THE PIPE, IN SUCH A MANNER AS NOT TO DAMAGE OR DISTURB THE PIPE OR ITS ALIGNMENT AND GRADE. BACKFILL MATERIAL ABOVE THE PIPE ZONE SHALL BE FREE OF DELETERIOUS MATERIALS AND LUMPS OR STONES EXCEEDING THREE (3) INCHES IN GREATEST DIMENSION AND SHALL BE PLACED IN LAYERS NOT EXCEEDING EIGHTEEN (18) INCHES. EACH LAYER SHALL BE THOROUGHLY COMPACTED BY VIBRATORY OR MECHANICAL TAMPING, OR BY A COMBINATION OF THESE METHODS. FLOODING AND JETTING SHALL NOT BE ALLOWED. THERE MUST BE AT LEAST ONE FOOT OF COVER OVER THE PIPE BEFORE COMPACTION ABOVE THE PIPE ZONE WILL BE ALLOWED. IMPORTED BEDDING AND BACKFILL MATERIAL SHALL BE OBTAINED, AND ANY EXCESS BEDDING AND BACKFILL MATERIAL SHALL BE DISPOSED, BY ANY LEGAL MEANS AT THE DISPOSAL OF THE CONTRACTOR. THE CONTRACTOR MAY SUBMIT TO THE ENGINEER SIEVE ANALYSIS FOR UTIUZA11ON OF IN—SITU MATERIALS. ACHIEVING _FIRM BEDDING BELOW PIPE SPRINGL INE. CONTRACTOR SHALL PROVIDE "FIRM BEDDING" SUPPORT FOR THE PIPE BELOW THE SPRINGLINE FIRM BEDDING MEANS THAT THE PIPE MUST REST ON THE GRANULAR MATERIAL SPECIFIED PREVIOUSLY IN THE SPECIFICATIONS. BELL OR COUPLING HOLES SHALL BE CAREFULLY EXCAVATED AT PROPER INTERVALS, SO THAT NO PART OF THE LOAD IS SUPPORTED BY THE BELLS OR COUPLINGS. DURING BEDDING AND BACKFILLING, CONSOLIDATION OF MATERIAL AROUND AND UNDER BELLS AND COUPLINGS SHALL BE AVOIDED. it0l CONTRACTOR SHALL SHOVEL—SLICE OR HAND TAMP BEDDING iN THE HAUNCH AREAS, AS THIS WILL MINIMIZE VOIDS BENEATH THE PIPE AND IN THE HAUNCH AREAS. SHOVEL—SLICING OR HAND TAMPING SHALL BE DONE BEFORE THE BEDDING IS BROUGHT UP TO THE QUARTER POINT OF THE PIPE. INITIAL; BACKFILL. "BEDDING MATERIAL" AS SPECIFIED BY ASTM 2321-8 SHALL BE USED IN THE PIPE ZONE FOR INITIAL BACKFILL. AFTER THE PIPE HAS BEEN PROPERLY LAID AND INSPECTED, INITIAL BACKFILL. SHALL BE PLACED ON BOTH SIDES AND OVER THE PIPE TO SUCH A DEPTH THAT, AFTER THOROUGH CONSOLIDATION, THE FINAL DEPTH SHALL, BE AT LEAST TO THE ELEVATION SHOWN ON THE PLANS. THE MATERIAL SHALL BE CONSOLIDATED BY VIBRATORY OR MECHANICAL TAMPING AND THE EQUIPMENT AND MANNER OF TAMPING MUST BE APPROVED IN WRITING BY THE ENGINEER PRiOR TO COMMENCING OPERATION. IMPACT EQUIPMENT MAY BE ALLOWED UNDER THE DIRECTION OF THE ENGINEER. HOWEVER, THE CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE RESULTING FROM THE USE OF THIS EQUIPMENT. HYDRA—HAMMER WILL NOT BE PERMITTED. SUBSEQUENT BACKFILL. ABOVE THE LEVEL OF INITIAL BACKFILL, THE TRENCH MAY BE BACKFILLED WITH NATIVE MATERIAL RESULTING FROM TRENCH EXCAVATION, OR AT THE OPI1ON OF THE CONTRACTOR, SELECT IMPORTED MATERIALS MAY BE USED. NATIVE MATERIAL OR IMPORTED MATERIAL MAY BE COMPACTED BY TAMPING AND/OR ROLLING, USING EQUIPMENT AND METHODS APPROVED BY THE ENGINEER. WHEN THE CONTRACTOR COMPACTS BY TAMPING AND/OR ROLLING, THE BACKFILL MATERIAL SHALL BE PLACED IN LAYERS NOT EXCEEDING EIGHTEEN (18) INCHES IN LOOSE DEPTH, EACH LAYER BEING THOROUGHLY COMPACTED BY TAMPING AND/OR ROLLING BEFORE SUCCEEDING LAYERS ARE PLACED. COMPACTION OF SUBSEQUENT BACKFILL WITHIN TWO AND ONE—HALF (2-1/2) FEET OF FINISHED PERMANENT SURFACING GRADE SHALL BE ACCOMPLISHED BY TAMPING AND/OR ROLLING AS SPECIFIED ABOVE. WHERE THE TRENCH IS WITHIN THE PAVEMENT ON STREETS, THE BACKFILL WITHIN TWO AND ONE-HALF (2-1/2) FEET OF FINISHED PERMANENT GRADE SHALL BE COMPACTED TO NINETY PERCENT (90%) RELATIVE COMPACTION. SUBSEQUENT BACKFILL PLACED BY TAMPING AND/OR ROLLING SHALL BE FREE FROM STONES OR LUMPS EXCEEDING THREE (3) INCHES IN GREATEST DIMENSIONS, VEGETABLE MATTER, OR OTHER UNSATISFACTORY MATERIALS. iN NO CASE SHALL JETTING BE ALLOWED FOR BACKFILL COMPACTION WITHIN THE STREET. WHEN APPROVED BY THE ENGINEER, JETTING MAY BE USED IN NON—STREET AREAS. BACKFILL TESTING AND COMPACTION. TESTING OF BACKFILL MATERIALS AND COMPAC11ON SHALL BE IN ACCORDANCE WITH SECTION 19, "EARTHWORK" AND SECTION 6-3, "TESTING", OF THE STANDARD SPECIFICATIONS, STATE OF CALIFORNIA, DEPARTMENT OF PUBLIC WORKS, DIVISION OF HIGHWAYS. EACH LAYER OF BACKFILL MATERIAL SHALL MEET THE COMPACTION, SAND EQUIVALENT, AND GRADATION REQUIREMENTS BEFORE THE NEXT LAYER IS PLACED. EACH LAYER OF BACKFILL SHALL BE THOROUGHLY COMPACTED TO THE RELATIVE COMPACTION OF NOT LESS THAN IS SHOWN ON CITY OF BAKERSFIELD STANDARD S-39 AS MODIFIED ON THE CONTRACT PLANS, EXCEPT THAT COMPACTION WITHIN THE ROADWAY STRUCTURAL SECTION SHALL BE NO LESS THAN NINETY PERCENT (90%) RELATIVE COMPACTION FOR THE TOP FINISHED 30", AND SHALL BE DETERMINED BY CALIFORNIA TEST METHODS 216 OR 231, OR ASTM (CURRENT EDITION) D1557 AND ONE OF THE FOLLOWING 02922 OR 01556. iF THE RELATIVE COMPACTION, AS DETERMINED BY TESTING, FAILS TO MEET THE SPECIFIED PERCENTAGE, THE TRENCH SHALL BE RE—EXCAVATED AND RE—COMPACTED. COuIPACTiON TESTS WILL BE THE SUBDIVIDERS RESPONSIBILITY. THE NUMBER AND LOCATIONS OF THE TESTS SHAD_ BE DETERMINED BY THE CITY ENGINEER. COMPACTION TEST NOTE — COMPACTION TESTS SHALL BE THE RESPONSIBILITY OF THE DEVELOPER/SUBDIVIDER/CONTRACTOR. THE NUMBER AND LOCATION OF REQUIRED TESTS SHALL BE DETERMINED BY THE CITY ENGINEER. SEWER PIPE SHALL CONFORM TO THE PLANS, AND THESE SPECIAL PROVISIONS. THE PRICE PER LINEAL FOOT SHALL INCLUDE BUT NOT BE LIMITED TO EXCAVATION, BEDDING AND BACKFILL. HANDLING OF MATERIALS. ALL PIPE, FITTINGS, SPECIALS AND CASTINGS MUST BE CAREFULLY HANDLED AT ALL TiMES. ONLY SUITABLE AND PROPER EQUIPMENT AND APPLIANCES SHALL BE USED FOR THE SAFE LOADING, HAULING, UNLOADING, HANDLING AND PLACING OF MATERIALS, SPECIAL CARE SHALL BE EXERCISED SO THAT PREFORMED RESILIENT JOINTS ON PIPE AND FITTINGS WILL NOT BE DAMAGED. ANY PIPE OR FITTING WITH A JOINT DAMAGED OR FLATTENED WILL CAUSE THAT PIPE OR FITTING TO BE REJECTED. PIPE LAYING. NO PIPE SHALL BE LAID UNTIL THE ENGINEER INSPECTS AND APPROVES THE COND11ION OF THE BOTTOM OF THE TRENCH. PIPE SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. PiPE LAYING SHALL BEGIN FROM THE DOWNSTREAM END OF THE TRUNK SEWER OR AS DIRECTED BY THE ENGINEER. PIPE LAYING SHALL PROCEED WITH EACH PiECE LAID .TRUE TO LINE AND GRADE, AND IN SUCH A MANNER AS TO FORM A CLOSE CONCENTRIC JOINT WITH THE ADJOINING PiPE AND TO PREVENT SUDDEN OFFSETS IN THE FLOW LINE. AS THE WORK PROGRESSES, THE INTERIOR OF THE PIPE SHALL BE CLEARED OF ALL DIRT AND DEBRIS OF EVERY DESCRIPTION. PiPE SHALL NOT BE LAID WHEN THE CONDITION OF THE TRENCH OR THE WEATHER IS UNSUITABLE. AT TIMES WHEN WORK IS NOT IN PROGRESS, OPEN ENDS OF PIPE AND FITTINGS SHALL BE CLOSED. WITH BELLED END PiPE, BELL HOLES SHALL THEN BE EXCAVATED AT EACH JOINT TO FACILITATE THE JOINT OPERATIONS, AND SHALL BE ONLY OF SUFFICIENT SIZE FOR THAT PURPOSE. iN ORDER THAT BELL HOLES MAY BE PROPERLY LOCATED, NOT MORE THAN SIX (6) HOLES SHALL BE EXCAVATED AHEAD OF ACTUAL PIPE LAYING, ON ACCOUNT OF THE VARIATIONS IN JOINT CONSTRUCTION OPERATIONS. CUTTING PIPE. THE CONTRACTOR SHALL PERFORM ALL WORK OF CUTTING PIPE AND SPECIAL CASTING NECESSARY TO THE ASSEMBLY, ERECTION, AND COMPLETION OF THE WORK. ALL PIPE SHALL BE CUT TO FIT ACCURATELY, NTH SMOOTH EDGES AND FACES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF CUTTING AND NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR ANY MATERIALS WHICH ARE DAMAGED OR INCORRECTLY CUT. PIPELINE TESTING. ALL SEWERS SHAD_ BE TESTED FOR TIGHTNESS WHEN COMPLETED AND READY FOR SERVICE. TESTING SHAD_ BE CONDUCTED IN ACCORDANCE WITH THE UNIFORM PLUMBING CODE AIR TEST METHOD UPC SEC. 318-6(4), OR THE WATER EXFILTRATiON TEST OR AIR PRESSURE TEST PER SECTION 306-1.4, "TESTING PIPELINES" OF THE 1994 EDITIONS, "STANDARD SPECIFICATIONS" FOR PUBLIC WORKS CONSTRUCTION, AND CHAPTER 1.3 OF THE CITY OF BAKERSFIELD SUBDIVISION DESIGN MANUAL, AND THE PIPE SUPPLIER'S REQUIREMENTS. THE CONTRACTOR SHAD_ NOTIFY THE ENGINEER 24 HOURS PRIOR TO ANY TESTING. CLEANING PIPE LINES. CARE SHALL BE EXERCISED IN LAYING OF PIPE LINES TO EXCLUDE DIRT AND ANY OTHER FOREIGN MATERIAL. VITEN PIPE LAYING IS INTERRUPTED, AS AT NIGHT, THE PIPE ENDS SHALL BE SUITABLY CLOSED. UPON COMPLETION, AND BEFORE PLACING INTO SERVICE, ALL LINES SHALL BE FLUSHED AND MANDRELLED TO REMOVE ANY DIRT OR FOREIGN MATERIALS WHICH WOULD CLOG PUMPS, EQUIPMENT, SPRAY HEADS, ETC. THE CONTRACTOR SHALL MAKE PROVISIONS FOR PREVENTING FOREIGN MATERIAL FROM BEING FLUSHED INTO AN EXISTING SEWER LINE. SEWER LATERALS. SEWER LATERALS SHALL CONFORM TO THIS IN EVERY REGARD. EXISTING SEWER LATERALS SHALL BE LOCATED BY THE CONTRACTOR AND CONNECTED TO AND EXTENDED OR RECONSTRUCTED ACCORDING TO THE PLANS. COMPRESSION COUPLINGS MAY BE UTILIZED FOR CONNECTING TO EXISTING LATERALS. POSITIVE GRADE TO THE ' TRUNK SEWER SHALL BE MAINTAINED AND INVERT GRADES SET AS CALLED ON THE PLANS. SEWER WYES SHALL BE INSTALLED ON THE TRUNK IN ACCORDANCE WITH THE PIPE MANUFACTURERS RECOMMENDATIONS. PAYMENT FOR SEWER LATERALS WILL BE PAID AS SEWER FOR THE APPROPRIATE DIAMETERS. 11. SYSTEM TESTING A MANDREL TEST AND PRESSURE TEST SHALL BE PERFORMED ON INSTALLED PIPE IN ACCORDANCE WITH THE CiTY OF BAKERSFIELD SUBDIVISION MANUAL AND THE RECOMMENDATIONS OF THE MANUFACTURER. PRiOR TO FINAL ACCEPTANCE, ALL SEWER LINES SHALL BE INSPECTED WITH VIDEO EQUIPMENT DESIGNED FOR THIS PURPOSE. THE TELEVISION CAMERA SHALL HAVE THE CAPABILITY OF ROTATING 3607, iN ORDER TO VIEW AND RECORD THE TOP AND SIDES OF THE PIPE, AS REQUIRED. THE VIDEO INSPECTION SHALL BE WITNESSED BY THE CITY'S CONSTRUCTION INSPECTOR,. WHO WILL ALSO INITIAL AND DATE THE "CHAIN OF CUSTODY" FORM. THE SUBDIVIDER SHALL IMMEDIATELY NOTIFY CITY OF ANY PIPE LOCATIONS REVEALED TO BE NOT IN COMPLIANCE WITH THE SPECIFICATIONS. A RECORDED VIDEO CASSETTE, THE COMPLETED "CHAIN OF CUSTODY" FORM AND A WRITTEN LOG (MICH INCLUDES THE STATIONING, BASED ON THE STATIONING OF THE APPROVED PLANS, OF ALL CONNECTED LATERALS) OF THE INSPECTION SHALL BE PROVIDED FOR VIEWING, AND SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ACCEPTANCE AFTER ACCEPTANCE, THE VIDEO CASSETTE SHALL BECOME THE PROPERTY OF THE CITY. 12. WYE FITTINGS SHALL BE INJECTION MOLDED !N—UNE TYPE AND SHALL BE USED FOR ALL LATERAL CONNECTIONS AND SHALL BE ROTATED A MINIMUM OF 23 DEGREES ABOVE THE HORIZONTAL PLANE RUNNING THROUGH THE CENTERUNE OF THE MAIN. ALL LATERALS SHALL BE 4" IN DIAMETER EXCEPT AS NOTED ON ,PLANS, EXTENDING A MINIMUM OF 4' BEYOND THE PROPERTY UNE OR RIGHT—OF—WAY UNE WITH 30" OF COVER AT FLOW LINE. SURFACE MARKERS FOR SEWER LATERALS SHALL BE INSTALLED AT THE PROPERTY UNE OR RIGHT—OF— WAY LINE AS SHOWN IN THE "SEWER LATERAL MARKER" DETAIL., C.O.B. STD. DET. SW -1. LATERALS SHALL BE A MINIMUM OF 5.0' DEEP AND A MAXIMUM OF 7' DEEP AT PROPERTY LINE OR RIGHT—OF—WAY UNE AND A MINIMUM OF 2.5' DEEP AT FLOWUNE. 13. ALL SEWER STUBS SHALL BE CLOSED WITH A STANDARD PLASTIC PLUG. SOLVENT WELDED. 14. ALL MANHOLES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF BAKERSFIELD STANDARD DRAWINGS S-7, S-8, AND S-21 AND SECTIONS 70-1.02H AND 71-1.07 OF THE STANDARD SPECIFICATIONS OF THE STATE OF CALIFORNIA, DEPARTMENT OF TRANSPORTATION, CURRENT EDITION. ALL CLEANOUTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CiTY OF BAKERSFIELD STANDARD DRAWING S-20. MANHOLES SHALL BE TYPE "A" FOR PIPES UNDER 48" IN DIAMETER AND TYPE "B" FOR PIPES 48" IN DIAMETER OR LARGER. UNLESS NOTED OTHERWISE. THE BOTTOM MANHOLE BARREL AT THE MANHOLE FOUNDATION SHALL BE SET ON A 2" MORTAR BED OR SET ON KENT—SEAL, IN A GROOVED FOUNDATION. 15. STORM DRAIN PIPE STORM DRAIN PIPE. CONTRACTOR SHALL UTILIZE RCP PIPE, CLASS III WITH RUBBER GASKET JOINTS PER ASTM SPECIFICATION C-76, UNLESS OTHERWISE NOTED ON THE CONTRACT PLANS. REINFORCED CONCRETE PIPE. REINFORCED CONCRETE PIPE SHALL CONFORM TO THE IN SECTION 65, "REINFORCED CONCRETE PIPE% OF THE STANDARD SPECIFICATIONS AND THESE SPECIAL PROVISIONS. EXCEPT AS OTHERWISE DESIGNATED BY CLASSIFICATION ON THE PLANS OR IN THE SPECIFICATIONS, JOINTS FOR CULVERT AND DRAINAGE PIPES SHALL CONFORM TO THE PLANS OR SPECIFICATIONS FOR STANDARD JOINTS. HYDROSTATIC TESTS SPECIFIED BY SECTION 65-1.08 "LAYING SIPHON AND PRESSURE PIPE", OF THE STANDARD SPECIFICA11ONS WiLL NOT BE REQUIRED. REINFORCED CONCRETE PIPE SHALL HAVE RUBBER GASKETED JOINTS CONFORMING TO SECTION 65-1.06B, "RUBBER GASKETED JOINTS", OF THE STANDARD SPECIFICATIONS. HANDLING OF MATERIALS. ALL PIPE, FITTINGS, SPECIALS AND CASTINGS MUST BE CAREFULLY HANDLED AT ALL TIMES. ONLY SUITABLE AND PROPER EQUIPMENT AND APPLIANCES SHALL BE USED FOR THE SAFE LOADING, HAULING, UNLOADING, HANDLING AND PLACING OF MATERIALS, SPECIAL CARE SHALL BE EXERCISED SO THAT PREFORMED RESILIENT JOINTS ON PIPE AND FITTINGS WILL NOT BE DAMAGED. ANY PIPE OR FITTING WITH A JOiNT DAMAGED OR FLATTENED WILL CAUSE THAT PIPE OR FITTING TO BE REJECTED. PIPE LAYING. NO PIPE SHALL BE LAID UNTIL THE ENGINEER INSPECTS AND APPROVES THE CONDITION OF THE BOTTOM OF THE TRENCH. PIPE SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. PIPE LAYING SHAH BEGiN FROM THE DOWNSTREAM END OF THE STORM DRAiN OR AS DIRECTED BY THE ENGINEER. PIPE LAYING SHALL PROCEED WITH EACH PIECE LAID TRUE TO UNE AND GRADE, AND IN SUCH A MANNER AS TO FORM A CLOSE CONCENTRIC JOINT WITH THE ADJOINING PiPE AND TO PREVENT SUDDEN OFFSETS IN THE FLOW LINE. AS THE WORK PROGRESSES, THE INTERIOR OF THE PIPE SHALL BE CLEARED OF ALL DIRT AND DEBRIS OF EVERY DESCRIPTION. PIPE SHALL NOT BE LAID WHEN THE CONDITION OF THE TRENCH OR THE WEATHER IS UNSUITABLE. AT TiMES WHEN WORK IS NOT IN PROGRESS, OPEN ENDS OF PiPE AND FITTINGS SHALL BE CLOSED. WITH BELLED END PIPE, BELL HOLES SHALL THEN BE EXCAVATED AT EACH JOINT TO FACILITATE THE JOINT OPERATIONS, AND SHALL BE ONLY OF SUFFICIENT SIZE FOR THAT PURPOSE. IN ORDER THAT BELL HOLES MAY BE PROPERLY LOCATED, NOT MORE THAN SIX (6) HOLES SHALL BE EXCAVATED AHEAD OF ACTUAL PIPE LAYING, ON ACCOUNT OF THE VARIATIONS IN JOINT CONSTRUCTION OPERATIONS. THE CONTRACTOR SHALL MAKE PROVISIONS FOR PREVENTING FOREIGN MATERIAL FROM BEING FLUSHED INTO AN EXISTING STORM DRAIN UNE. CUTTING PIPE. THE CONTRACTOR SHALL PERFORM ALL WORK OF CUTTING PiPE AND SPECIAL CASTING NECESSARY TO THE ASSEMBLY, ERECTION, AND COMPLETION OF THE WORK. ALL PIPE SHALL BE CUT TO FIT ACCURATELY, WITH SMOOTH EDGES AND FACES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF CUTTING AND NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR ANY MATERIALS WHICH ARE DAMAGED OR INCORRECTLY CUT 16. BORED/JACKED PIPE CASING OR SMOOTH OUTSIDE WALLED PiPE FOR BORED/JACKED PIPE SHALL BE INSTALLED. iT SHALL HAVE EVEN BEARING THROUGHOUT ITS LENGTH AND SHALL SLOPE TOWARD ONE END. SPACE BETWEEN CASING AND PIPELINE SHALL BE BACKFILLED WITH SAND. IF THE PIPE AND CASING ARE INSTALLED BY BORING, THE SPACE AROUND THE CASING ALSO SHALL BE BACKFILLED WITH GROUT OR SAND. THE ENDS OF SPACE BETWEEN THE CASING AND THE PIPE SHALL BE SEALED WITH GROUT. THE STRENGTH OF PiPE DESIGNATED IN THE PLANS OR SPECIFICATIONS IS DETERMINED FOR VERTICAL LOAD ONLY ANY ADDITIONAL STRENGTH REQUIRED BY BORING/JACKING OPERATIONS SHALL BE FURNISHED AT THE CONTRACTOR'S EXPENSE. THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR APPROVAL ALL PLANS OF BORING/ JACKING OPERATIONS PRIOR TO BORING OR JACKING. BORING/JACKING OPERA11ONS SHALL BE CONDUCTED IN A SAFE AND EFFICIENT MANNER, CONSISTENT NTH CURRENT ACCEPTED PROCEDURES. WATER BORING SHALL NOT BE PERMITTED. THE CASING PiPE SHALL BE JACKED WITH SUCH PRECISION THAT WILL ALLOW THE REPLACEMENT OF THE PIPELINE TO THE LINE AND GRADE AS INDICATED ON THE PLANS. UPON COMPLETION OF THE INSTALLATION OF THE CASING AND INSTALLATION OF THE PIPELINE TO GRADE, THE VOID BETWEEN THE CASING OR RC PIPE AND THE EXCAVATION SHALL BE COMPLETELY FILLED WITH SAND, COMPACTED BY THE USE OF AIR—BLOWING SAND EQUIPMENT OR ANY OTHER MEANS ACCEPTABLE TO THE ENGINEER UPON HIS APPROVAL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN A SAFE OPERATION AT ALL TiMES. "SHOULD THE TUNNEL HEADING OPERATIONS RESULT iN DANGEROUS OR UNREASONABLE SLOUGHING OF MATERIAL WHICH MAY JEOPARDIZE THE SAFETY OF WORKERS OR THE STABILITY OF THE SOL AND ROADWAY ABOVE, THE CONTRACTOR SHALL FURNISH AND INSTALL BREASTBOARDING AND/OR FACE CLOSURE WITH SUFFICIENT JACKS TO INHIBIT THE SLOUGHING AND/OR CLOSING THE WORK FACE. THE CONTRACTOR, BEFORE RESUMING WORK, SHALL FURNISH THE ENGINEER WITH A DETAILED PLAN OF PRECEDING WITH THE WORK, FOR HIS REVIEW AND APPROVAL. ANY AND ALL EXPENSES THEREFORE WILL BE CONSIDERED AS INCLUDED IN THE BID PRICE AND NO ADDITIONAL COMPENSATION WILL BE MADE THEREFORE. 17.IN STRUCTURES . MINOR STRUCTURES. PORTLAND CEMENT CONCRETE MINOR STRUCTURES SHALL CONFORM, IN DESIGN, MATERIALS, AND CONSTRUCTION, TO THE PROVISIONS OF SECTIONS 70-1.02 H OF THE STANDARD SPECIFICATIONS AND THESE SPECIAL PROVISIONS. MANHOLES SHALL CONFORM TO THE CITY OF BAKERSFIELD STANDARDS S-7 AND S-8. DRO' INLETS SHALL CONFORM TO THE CITY OF BAKERSFIELD STANDARD S-12. TEMPORARY INLET GRATES SHALL CONFORM TO DETAILS ON THE PLANS. THE PRECAST CYLINDER, TAPER, AND ECCENTRIC FLAT TOP SECTIONS SHALL MEET THE STRENGTH REQUIREMENT OF ASTM. C-478. EACH SUCCESSIVE MANHOLE SECTION SHALL BE SET ON A BED OF PORTLAND CEMENT GROUT OR "KENT SEAL" TO MAKE A WATERTIGHT JOINT, SHALL BE NEATLY POINTED ON THE INSIDE, AND SHALL BE SET PLUMB. 18. ADJUST SURVEY MONUMENT ENCASEMENTS SURVEY MONUMENT AND FRAME AND COVER WITH ENCASEMENTS SHALL BE ADJUSTED OR INSTALLED NEW TO FINISH GRADE AT THE LOCATIONS SHOWN ON THE PLANS, IN ACCORDANCE WITH THESE SPECIAL PROVISIONS, AND CITY STANDARD S-29. THE SURFACE OF THE CONCRETE SHALL BE PROTECTED FROM PUBLIC TRAFFIC FOR A MiNIMUM OF THREE DAYS. AT THE OPTION OF THE CONTRACTOR, MINOR CONCRETE CONTAINING A MINIMUM OF SEVEN SACKS OF CEMENT PER CUBIC YARD MAY BE USED AND THE 11ME REQUIRED FOR PROTECTION OF THE CONCRETE SURFACE FROM PUBLIC TRAFFIC SHALL BE REDUCED TO A MINIMUM OF ONE DAY. THE MONUMENT WILL BE SET BY OTHERS. THE OWNER WILL PROVIDE SURVEYS. CONTRACTOR SHAD_ GIVE THE OWNER 24 HOURS NOTICE WHEN SURVEYS ARE REQUIRED. ANY MONUMENT FRAME OR COVER DAMAGED BY THE CONTRACTOR OR HIS OPERATIONS SHALL BE REPLACED BY THE CONTRACTOR AT NO COST TO THE OWNER. AN OPEN STREET PERMIT SHALL BE OBTAINED FROM THE CITY OF BAKERSFIELD PUBLIC WORKS DEPARTMENT FOR ANY WORK PERFORMED WITHIN ACCEPTED STREET RIGHT—OF—WAY. UNLESS SECURED BY A SUBDIVISION AGREEMENT, A DEPOSIT BASED ON APPROVED ENGINEER'S ESTIMATE FOR THE WORK PERFORMED WITHIN THE RIGHT—OF—WAY AND INSURANCE SHALL BE POSTED PRIOR TO ISSUANCE OF THE PERMIT. 19. CONNEC11ON SEAL TO PVC LINED SEWER UNE OR MANHOLE THE CORED HOLE SHALL BE APPROXIMATELY 3 INCHES GREATER THAN THE OUTSIDE DIAMETER OF THE CONNECTING UNE. THE CORES HOLE SHALL BE DESIGNED TO CUT A HOLE WITH MINIMUM DAMAGE TO REINFORCING STEEL, PIPE OR PLASTIC LINER. PRIOR TO THE INSTALLATION OF THE PVC BOOT ON THE CONNECTION, THE PLASTIC LINER AROUND THE PIPE AT THE CORED HOLE SHALL BE CLEANED PER THE PLASTIC LINER MANUFACTURER'S RECOMMENDATION. THE END OF THE CONNECTING LINE SHALL BE SEALED TO THE PVC BOOT WITH SIKA 449/203 PRIMER AND SIKA FLEX 1A SEALANT OR AN APPROVED EQUAL. THE PVC BOOT SHALL BE ORDER SO IT WILL FIT SNUGGLY TO THE OUTSIDE WALL OF THE CONNECTION. THE PVC BOOT AND WELD STRIPS SHALL BE INSTALLED AND TESTED FOR HOLIDAYS PER THE PLASTIC LINER MANUFACTURER'S RECOMMENDATION. THE CONNECTION LINE SHALL BE CENTERED IN THE CORED HOLE AND PLACED SO IT IS FLUSH WITH THE INSIDE WALL OF THE RCP. THE PVC BOOT WELD STRIPS SHALL BE MANUFACTURED BY AMERON, INC. OR AN EQUAL APPROVED BY THE CITY ENGINEER. 1, ,., -.7 0% 0% Am% r-. I „ ol �IIINIIII LADBROOK WAY NII ; SEE SHEET 4 / I I ♦ �� $a / �. co o d cr_ co tCUL-DE-SAC p, cn STA. 31+71.55 C.L. M V) �� 3 z z cf) 00 10 J 10 co v WC3+ 00 11 3 C.) + 9 UJ x r- cn 0 C; w <0 LLJ F..: z r - V) Oq _j _j w af C*4 _j 0,00. M (:s Z Z LLJ c6 LLJ tc) tn ce Uj Te) w + .00 IW4* cl) IN 0 M to < Oq 9' P _j J <cj + z 8*W-SEE (3 LLJ C4 to I Uj cn 30' 0 0: 0 WATER cn 0 < + < z c! 1,1, w C3 4 0:: a V) am a cl _j wd, W PLANS Oq 0z 5:= w LIJ 0 Z --! M C-) W 0; 0; 00 < d + < CJ + cn UJ n to w to cn P cn M 00 rl� N cn 1 024 kL1 cr; of c%j u-cn + + + 00 w + to Q L cn + + 0! cli cn a CN 04 04 R/W M A^ I rn < 0_j 04 CN 0 n zw VNI I'd, + N I W " %­ - 4 4 W (D cn 0; 6' MIN. BLOCK WALL i 7 cn + cn r- cn + w rn 00 c*4 < PER SEPARATE PLANS ,<� <� ", �<_: ;z -< LO + + cn cn C14 cn + 3 C14 00 c%j M c/) Irb R/W N 04 04 R/W 10 N x kn I- -SEE WATER PLANS cn Sea 0% EX. 8"W 8"W -SEE WATEB PLANS 8"W -w- 53 cn w -W-cn-**- 1) . . . . . . . . ....... _w ------------------------ ------------------- - -- ---------------------------------------------------- ---------------------- ------------- - ----------------------------- -- - ------- -- --------- vE A*S �S_L _77 In EX 8 S S5=7, S56*00'19* 185.12 Nw 600 00- 16061 EX___ 5- P"W �X ------------ C:) -------- ---- \Iff ---------------------- -- ------ ----- -------------------------------------------- ------------------------ CO -CD ------------------ TP - ------------- 23+00 6 LTP -C-4 re) TP T 6�3�1 -2 25+00 27+00 %_ 4 L6. 29+00 EX. 34" PG&E HIGH PRESSU _SAS' 4111- 1 1----F---346.71 G G G G E; G +G--- ­/-G-C:)---G---G-- 0 -G---G- N56*45 49"W 8"S (0) 24+00 _0_4 L4 26+00 EX. 34 PG&E HIGH -0-RESSURE GAS 28+00 N56.4526 511.20' 30+00 PRIVATE 90 S5 031'01 8 .0185132' ON 00 C), -8 S56 0�5'17"E�80n_N 6 Ile) 06 -3S5? -E 6*S LO LANDSCAPE W-05171 J00.00 Nz, 1116 C14 EX. 18*D AREA - - - - - - - - - - - - - - - - - - - - - - - - - - EX. 18"D D D f N56'45 26 18"D 1, 13' R/W7 ot 10 -in R/W II C> IN to a; 1 0 c; 0) n 7M c*4 w R/W0 c� w to . f- W cs (1)06 00 cr v- W J 0 C14 z c:5 ce- 6z w 1=z %_ O C44 0) C) cr- P6 f �_ 0 V) ci w W C.) w + 06 0 C> ci _j CI W n z ce- CF; = O" .4:, 27 ;z w Z 0 cn C) C5 C4 z z CD n MM c� z Cp C1 IN CD 0) U css 0) z a; co N < •CNI C> 0: C> + co + + Im 0 1 z4 Q �2 w op 00 00 W IN + a. + .-j 06 Ir- 00 0) 0) 0++ w cj cn X + ANN 0"o + + (zo cn r - CDC) cn 6cn + A 0�0 06 on I a Q :z n c*4 0: 0 C1 d:t 4C4,j + +zowc;0;(n M w cq+ + < M LO Ln ; I- cn V) cn It 0� " " cn (/)I(/) cn cn rn t1q - <: 9117 •04 C-4 re) 00 5 t- xCvn) n + LAJ 1L ?Aj (D C4 a. cf) cf) PO 5* KNIT V) 5cn UNIT 4 LMBROM WAY SEE SHEET 4 HIGHGATE GREENS DRIVE STA. 23+39.01 C.L. TO STA. 31+71.55 C.L. SCALE: 1" = 401 HORIZONTAL SCALE: 1" = 4' VERTICAL INSTALL 30.18 LF OF INSTALL 19.82 LF OF W PVC SEWER 0 -0.25% INSTALL 130.43 LF OF INSTALL 100.00 LF OF 364 Q* 019% CCUCC A _n or%w mcTA" ion jo i r Ar j pur cruto 364 362 360 358 356 354 352 350 348 346 364 362 360 358 356 354 352 350 348 346 344 342 340 Iwo 336 334 23+00 INRTAI I IQ RA IF (W 25+00 28+00 INSTALL 30.18 LF OF 30+00 ILItIVAII 4AOA%4 Ir- ^r- 31+00 jqj$ pv - 6- PVC SEWER 0 -1.00%9 1 Li N 16'48'1 7" W 20.00' L2 N 5615'42* W 19.82! L3 N 57*25'00" W 1NSTAI1 185.19 LF OF ir PVC SEW 200.00' ro N 7311'43" E 101.34' L6 INS OF 8" PVC -U.2076 63.38' L8 N 61-00`16- W 50.23' w6l* py^ %A -A- C-4 MFS ro _wN co >< Uj C) C1 Ui _j M w A co I_z �111,1,1,1 _j 0 2 0) a z as U') C5 Z I co c 00 co C3 0 Uj z V) z 00 Do LL C4 cr• DOA cr 3: LLI V) 00 3t LL c! z v 67*00* ZZ 2 1 co OC M z 1 z C3 >: >: Z_Z 0 cli Z co 0 LLI -00 to 200 *00 C3 0 Z �j C) L� d zmz 0) Uj C-5 0) if) _Uj 00 < LLJq- Z,4 < toCA rt) v US 6 + to LJ >: >: Z Z_ w X z tz 0 M -0 r- 0? -114 + 00 0000 _j 0- 06 z M -a W L>� > v- O U-) in Z < ots U.) + 00 00 0) le _3 c*4 O C� in 0) L0 W) to 3: =100 0:: 04 N M cn LL c/) U3 cn Uj co tx + CL >; UJ + cy) r r < "s + rn Of Uj z Z C-4 tA 16 3 I L . >: i� C4tS cf) LLJ Uj Uj Uj P 10 td P_ 15 V) V) 04 N 0, Q !� V) W !ti LLJ Uq LL <� Ui LL w APPROXI k ^nAr%f- ATE EAS11N h tW'LI'rrTM ILI!-\ % . j LLJ LL L _j c U.1 w U) 4 Uj %OUJI# I LJNUII DWI w APPROXIMATE EXISTING GRADE TERLINE 11 INV. 8-S (TO BE A ......... CONSTRUCTED WITH 2 8"W . ............ 2 8"W ......... T RAI, - T 7302 MIT 2) TRACT 7302 - U AT 2) ...... INV. 6-S ......... INV. 8 . ......... . INV. 6' •& ........ INV. 18W7 INV. frs ............. A • INV. 8"S J Dj INV. E *S INV. TS INV. 8*S INV. leD 3 3 23+00 INRTAI I IQ RA IF (W 25+00 28+00 INSTALL 30.18 LF OF 30+00 ILItIVAII 4AOA%4 Ir- ^r- 31+00 jqj$ pv - 6- PVC SEWER 0 -1.00%9 1 Li N 16'48'1 7" W 20.00' L2 N 5615'42* W 19.82! L3 N 57*25'00" W 1NSTAI1 185.19 LF OF ir PVC SEW 200.00' ro N 7311'43" E 101.34' L6 INS OF 8" PVC -U.2076 63.38' L8 N 61-00`16- W 50.23' w6l* py^ %A -A- C-4 MFS ro ix Uj C) C1 Ui M w �111,1,1,1 0 2 0) a 00 co z cr 3: LLI V) 00 3t LL c! z v M z 00 00 Z_Z 0 (D to -w C3 _j *00 voc �j z z - - - 0) Uj C-5 < LLJq- 0 0? LIJ Ib z M -a _z, -� F + 00 00 0) le _3 c*4 O C� in 0) L0 W) to 3: =100 00 CD M 04 tx 04 CL >; UJ + cy) r r < "s 04 cn cn Uj z Z C-4 tA C4tS cf) LLJ Uj td P_ 15 V) V) 0, Q !� V) W !ti LLJ <� Ui LL w APPROXI k ^nAr%f- ATE EAS11N h tW'LI'rrTM ILI!-\ % %OUJI# I LJNUII 11 IV. EX. 8!S TO BE A ......... CONSTRUCTED WITH 2 8"W . ............ ......... T RAI, - T 7302 MIT 2) . ...... ...... INV. 6-S INV. 8 INV. 18W7 INV. frs A INV. leD 3 if(TO rD C-4 1-: CON"' TRUCTED W1'H 0 TRACT 7Z 02 - UNIT 2) 0 *00 C? cnj M" 400 �_j V_ *00 W_ cn P- 00 Ix 0 • 04 0)(0co 04 1- �_Ck: + -q- -It P >:_j W w 012 LLJ.- " te)" C14 cn j Eu w 8wd Ui > U w wi INSTALL 78.13 LF 4 18- RGA- CP ® 0.11 III-- I I I I 23+00 24+00 25+00 26+00 28+00 29+00 364 362 360 358 356 354 352 350 348 346 344 342 340 338 336 334 31+00 362 360 358 356 354 352 350 348 346 LINE TABLE LINE BEARING LENGTH Li N 16'48'1 7" W 20.00' L2 N 5615'42* W 19.82! L3 N 57*25'00" W 19.83' L4 N 56*44!26* W 200.00' L5 N 7311'43" E 101.34' L6 N 11*3352" W 29.33' L7 N 28'59'44- E 63.38' L8 N 61-00`16- W 50.23' CAUTION: CONTRACTOR TO KEEP 7' HORIZONTAL CLEARANCE FROM EXISTING 34" HIGH PRESSURE PG&E GAS LINE EXCEPT AT CROSSING. REFER TO PG&E ON SHEET & I SCALE: 1 = 40' 40 20' LEGEND:. ABBREVIATIONS FL FLOWUNE PA PROPERTY LINE CL CENTERLINE E.P. EDGE OF PAVEMENT ELEV ELEVATION TP TOP OF PIPE MH MANHOLE FC FINISHED CONCRETE CB CATCH BASIN R/W RIGHT-OF-WAY JB JUNCTION BOX A.P. ANGLE POINT ELEV ELEVATION C&G CURB AND GUTTER T.O.M. TOP OF MANHOLE T.O.C. TOP OF CLEANOUT SCP STREET CONSTRUCTION PLAN EX. EXIS71NG TEMP. TEMPORARY INV. INVERT TRACT BOUNDARY CENTERLINE UNIT BOUNDARY w EXISTING WATER w PROPOSED WATER - REFER WATER PLANS. s EXISTING SEWER D EXISTING STORM DRAIN CONSTRUCT STORM DRAIN UNE PER CITY STANDARDS 0 CONSTRUCT STORM DRAIN MANHOLE TYPE 'A" PER C.O.B. STD. SW -4 & SW -5. CONSTRUCT TYPE "A" CATCH BASIN WITH 3.5' OPENING PER C.O.B. STD. D-14, UNLESS NOTED OTHERWISE. CONSTRUCT SEWER UNE PER CITY STANDARDS G CONSTRUCT SEWER MANHOLE TYPE "A" PER C.O.B. STD. SW -4 AND SW -5. CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. SW -6. /-PIPE SIZE ew UTILITY: W -WATER D -DRAIN G -GAS S--7SEWER SEC11ON DESIGNATION: SECTION LETTER 2 SHEET WHERE SECTION IS SHOWN NOTES: 1. ALL PIPE ELEVATIONS SHOWN ARE INVERT ELEVATIONS UNLESS OTHERWISE NOTED. 2. ALL CATCH BASINS TO BE TYPE *A* WITH 3.5! OPENINGS PER C.O.B. STD. D-14, UNLESS NOTED OTHERWISE. 3. REMOVE ALL EX. TEMP. CLEMOUTS AT THE UNIT BOUNDARY AND CONNECT TO EXISTING SEWER. CONTRACTOR TO VERIFY LOCATION AND INVERT OF EXISTING SEWER PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES. 4. REMOVE CAP & CONNECT TO EXISTING STORM DRAIN ON HIGHGATE GREENS DRIVE. CONTRACTOR TO VERIFY LOCATION AND INVERT OF EXISTING STORM DRAIN PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER OF MY DISCREPANCIES. 5. ALL SEWER LATERALS SHALL BE 4" IN SIZE, UNLESS NOTED OTHERWISE. CONSTRUCTION NOTES: IF PHASES 3 & 4 ARE NOT TO BE CONSTRUCTED SIMULTANEOUSLY, THEN THE DEVELOPER OF PHASE 3 SHALL CONSTRUCT TEMPORARY SEWER CLEANOUT OR STUB &PLUG AS PART � PHASE 3. CONSTRUCT PIPE SADDLE PER C.O.B. STD. D-9 AT LOCATIONS OF CROSSING PIPES WITH CLEARANCE LESS THAN 12". CONNECT TO EXISTING SEWER/STORM DRAIN. CONTRACTOR TO VERIFY LOCATION AND INVERT OF EXISTING SEWER/STORM DRAIN PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER OF 'ANY DISCREPANCIES. Knnvi what's helow a Call before you dig. 14 ---------- 0:: 3 lot '0 'j0 '_ m W IV) Z M Z O , (n + %_ T_ D C1 + D C1 c� C3 C) ++13 I 12 cn �� , t I WWW HINFELL COURT STA. 10+00.00 C.L. TO STA. 12+55.18 C.L. SCALE: 1" = 40' HORIZONTAL SCALE: 1" = 4! VERTICAL 364 362 360 358 356 354 352 350 348 346 W ck: ck: C> cn 1 Lo Mon= CUL-DE-SAC 44,S A. 12+55.18 C -L • '0' .00 10 . SCALE: 1 = 40' 40 20 0 40 80 6� INSTALL 100.00 LF OF LINE INSTALL 156.63 LF (F 8" PVC: SEWER 0 0.25% �� E.P. EDGE OF PAVEMENT 6 SEWER 0 1.00% 7 MH MANHOLE FC FINISHED CONCRETE CB CATCH, BASIN R/W RIGHT-OF-WAY JB JUNCTION BOX A.P. ANGLE POINT ELEV ELEVATION C&G CURB AND GUTTER T.O.M. TOP OF MANHOLE T.O.C. TOP OF CLEANOUT SCP STREET CONSTRUCTION PLAN cq 11 J TEMPORARY i LAJ C) S 11*4526" E 72.68' C3 W cn c"0i a 56.20' Z 0 (/) cl - us LO N 78'14'34" E 11 Wyl�� Jus 06 0 3: JC ca N0Ui W Ws C.3 a W Z (3 4"WCO w UTILITY: W -WATER D -DRAIN p cc + La J GOOD D 0.: CIP V7Q:co THEN THE DEVELOPER OF PHASE 3 SHALL CONSTRUCT TEMPORARY J 00 SEWER CLEANOUT OR STUB & PLUG AS PART OF PHASE 3. V7 z -4 I— d > 0 + Know whafs below. d CROSSING PIPES WITH CLEARANCE LESS THAN 12'. TO EXISTING SEWER/STORM DRAIN. CONTRACTOR TO CaII INV.18'DO (D VERIFY LOCATION AND INVERT OF EXISTING SEWER/STORM DRAIN i CO PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER OF ANY cf) 8"W DISCREPANCIES. kd cf) r) -70f%r) 0 W z 0 0 A 0 00 00 C4 a 2 0000 = � < . 0 • m C5 >: S37"29"OTE EL 5q.63' I 00 6 :j, N37*29'004 255.187 _.4 11+00 00 0 12+00 z 0!g + 6 -* to -t') CD ---------- 0:: 3 lot '0 'j0 '_ m W IV) Z M Z O , (n + %_ T_ D C1 + D C1 c� C3 C) ++13 I 12 cn �� , t I WWW HINFELL COURT STA. 10+00.00 C.L. TO STA. 12+55.18 C.L. SCALE: 1" = 40' HORIZONTAL SCALE: 1" = 4! VERTICAL 364 362 360 358 356 354 352 350 348 346 W ck: ck: C> cn 1 Lo Mon= CUL-DE-SAC 44,S A. 12+55.18 C -L • '0' .00 10 . SCALE: 1 = 40' 40 20 0 40 80 6� INSTALL 100.00 LF OF 10+00 11+00 LEGEND: LINE INSTALL 156.63 LF (F 8" PVC: SEWER 0 0.25% CENTERLINE E.P. EDGE OF PAVEMENT 6" PVC SEWER 0 1.00% TP TOP OF PIPE MH MANHOLE FC FINISHED CONCRETE CB CATCH, BASIN R/W RIGHT-OF-WAY JB JUNCTION BOX A.P. ANGLE POINT ELEV ELEVATION C&G CURB AND GUTTER T.O.M. TOP OF MANHOLE T.O.C. TOP OF CLEANOUT SCP STREET CONSTRUCTION PLAN EX. EXISTING TEMP. TEMPORARY INV. INVERT S 11*4526" E 72.68' C', N 13'39'41" E 56.20' C> WW Z (n N 78'14'34" E 11 Wyl�� UNIT BOUNDARY W c*4 W PROPOSED WATER - REFER WATER PLANS. 4"WCO w UTILITY: W -WATER D -DRAIN s EXISTING SEWER J GOOD D EXISTING STORM DRAIN THEN THE DEVELOPER OF PHASE 3 SHALL CONSTRUCT TEMPORARY J 00 SEWER CLEANOUT OR STUB & PLUG AS PART OF PHASE 3. z -4 I— d > 2 CONSTRUCT PIPE SADDLE PER C.O.B. STD. D-9 AT LOCATIONS OF Know whafs below. d CROSSING PIPES WITH CLEARANCE LESS THAN 12'. TO EXISTING SEWER/STORM DRAIN. CONTRACTOR TO CaII INV.18'DO 2®CONNECT VERIFY LOCATION AND INVERT OF EXISTING SEWER/STORM DRAIN CO PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER OF ANY 000. 0� DISCREPANCIES. kd r) -70f%r) 0 W z 0 0 A 0 00 00 C4 a 2 0000 = � < . 0 • m C5 >: o m :j, C; CO cmto Z ___ GOD z 0!g + 6 -* to -t') CD 00 + '4- V_ Ci viiT C) fe) _! C-4 MM ; >: U4 :3= tst�t.11 _j _j AP " F ROXIMATE I NISHED z< Uj �m 3 al 102%0 00 00 0 INSTALL (1) cn Uj W G?ADE 0 CENTERLINE RGJ-RCP Q 0.11% I 0 to 200 d >: 0 00 Z Z 00 to OU Z < L q 0 CM-, • ...... >: Z = >: - INV. 6"S _c> I 1W 1qr INV. B'S m z C1 C1 pe 5 = Z -r- b. 4m CD + oo 00 + 14, *4- MM 10+00 11+00 LEGEND: LINE FL ABBREVIATIONS FLOWLINE PA PROPERTY LINE CL CENTERLINE E.P. EDGE OF PAVEMENT ELEV ELEVATION TP TOP OF PIPE MH MANHOLE FC FINISHED CONCRETE CB CATCH, BASIN R/W RIGHT-OF-WAY JB JUNCTION BOX A.P. ANGLE POINT ELEV ELEVATION C&G CURB AND GUTTER T.O.M. TOP OF MANHOLE T.O.C. TOP OF CLEANOUT SCP STREET CONSTRUCTION PLAN EX. EXISTING TEMP. TEMPORARY INV. INVERT S 11*4526" E 72.68' TRACT BOUNDARY N 13'39'41" E 56.20' CENTERLINE N 78'14'34" E 11 Wyl�� UNIT BOUNDARY W EXISTING WATER W PROPOSED WATER - REFER WATER PLANS. 4"WCO w UTILITY: W -WATER D -DRAIN s EXISTING SEWER D EXISTING STORM DRAIN IT15111 36-41 362 360 358 356 354 352 350 348 'ZA& 13+00 LINE TABLE LINE BEARING LENGTH Li N 33'14'34' E 160.06 L2 N 74'3648 W 26.09' L3 S 3314!34!' W 130.76 L4 N 02*36'27* E 15.11' L5 S 37129"00" E 100.00' L6 N 07*31'00* E 70.02' L7 N 82*29'00" W 58.21' L8 S 52'31'00" W 5.00' L9 N 50*52!22" W 53.12' Li 0 S 11*4526" E 72.68' L11 N 13'39'41" E 56.20' Li 2 N 78'14'34" E 58.54! %JUU 354 352 350 348 346 344 342 340 338 336 334 332 SECTION � �4 SCALE: 1 40' HORIZ. 1 4' VERT. YMINFELL COURT SEE LEFT 356 APPR ;0 MATE (MATE 356 352 FINISHED ADE 352 348 0 PIPE 348 344 346 342 344 340 342 _j 340 336 338 334 336 332 334 AND SW -5. EXISTING STORM DRAIN PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER OF ANY DISCREPANCIES. CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. SW -6. 5. ALL SEWER LATERALS SHALL BE e IN SIZE, UNLESS NOTED OTHERWISE. ® /-PIPE SIZE ISISTRUC110N NOTES: � 4"WCO w UTILITY: W -WATER D -DRAIN 8"S C,GAS S -SEWER IF PHASES 3 & 4 ARE NOT TO BE CONSTRUCTED SIMULTANEOUSLY, THEN THE DEVELOPER OF PHASE 3 SHALL CONSTRUCT TEMPORARY SECTION DESIGNATION: SEWER CLEANOUT OR STUB & PLUG AS PART OF PHASE 3. SECTION LETTER 2 CONSTRUCT PIPE SADDLE PER C.O.B. STD. D-9 AT LOCATIONS OF Know whafs below. CROSSING PIPES WITH CLEARANCE LESS THAN 12'. TO EXISTING SEWER/STORM DRAIN. CONTRACTOR TO CaII INV.18'DO 2®CONNECT VERIFY LOCATION AND INVERT OF EXISTING SEWER/STORM DRAIN SHEET WHERE SECTION IS SHOWN PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER OF ANY 14 0� DISCREPANCIES. r) -70f%r) 0 W z 0 0 A 00 C4 a 2 0000 0 C*4 00 C5 >: o m d a Z Z ___ z Z" to -t') CD 00 Ci viiT C-4 MM 0:: :3= Ili Ui L4 z< 102%0 00 00 INSTALL 26.09 LF OF 18" tu6i RGJ-RCP Q 0.11% I 332 SECTION � �4 SCALE: 1 40' HORIZ. 1 4' VERT. YMINFELL COURT SEE LEFT 356 358 354 356 352 354 350 352 348 350 346 348 344 346 342 344 340 342 338 340 336 338 334 336 332 334 HIGHGATE GREENS DRIVE SEE SHEET 3 I � li N � �I I � 00 z cn C.D ca 8 < m r) 1" 1 ', I . I '="� CI cn D! U W p I vI cn cn 1818'1 1 1 30 3 00 HIGHGATE GREENS DRIVE SEE SHEET 3 LADBROOK W.. AY STA. 10+00.00 C.L. TO STA. 14+41.75 C.L. SCALE: 1" = 40' HORIZONTAL SCALE: 1" = 4! VERTICAL INSTALL 139.38 LF OF 8 PVC SEWER 0 -0.25% INSTALL 130.76 LF OF 8" PVC SEWER 0 -0.25% C.O.B. STD. D-14, UNLESS NOTED OTHERWISE INSTAIL 160.00 U-' OF 6' PV(,' SEWER 0 1.00% LOCATION AND INVERT OF EXISTING SEWER PRIOR TO S CONSTRUCT SEWER LINE PER CITY STANDARDS CONSTRUCTION AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES. 4. REMOVE CAP & CONNECT TO EXISTING STORM DRAIN ON HIGHGATE CONSTRUCT SEWER MANHOLE TYPE "A" PER C.O.B. STD. SWI GREENS DRIVE. CONTRACTOR TO VERIFY LOCATION AND INVERT OF AND SW -5. EXISTING STORM DRAIN PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER OF ANY DISCREPANCIES. CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. SW -6. 5. ALL SEWER LATERALS SHALL BE e IN SIZE, UNLESS NOTED OTHERWISE. ® /-PIPE SIZE ISISTRUC110N NOTES: � 4"WCO w UTILITY: W -WATER D -DRAIN C,GAS S -SEWER IF PHASES 3 & 4 ARE NOT TO BE CONSTRUCTED SIMULTANEOUSLY, THEN THE DEVELOPER OF PHASE 3 SHALL CONSTRUCT TEMPORARY SECTION DESIGNATION: SEWER CLEANOUT OR STUB & PLUG AS PART OF PHASE 3. SECTION LETTER 2 CONSTRUCT PIPE SADDLE PER C.O.B. STD. D-9 AT LOCATIONS OF Know whafs below. CROSSING PIPES WITH CLEARANCE LESS THAN 12'. TO EXISTING SEWER/STORM DRAIN. CONTRACTOR TO CaII before you dig. 2®CONNECT VERIFY LOCATION AND INVERT OF EXISTING SEWER/STORM DRAIN SHEET WHERE SECTION IS SHOWN PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER OF ANY 14 0� DISCREPANCIES. r) -70f%r) ML, 0 0 A o viiT 0:: 102%0 00 00 tu6i 0 to 200 d >: 0 00 Z Z 00 to OU Z < L q 0 CM-, L4 >: Z = >: - _c> I 1W 1qr m z C1 C1 pe 5 = Z -r- b. 4m CD + oo 00 + 14, *4- MM C'i 1"* .0- 06 tn F + WW a_ Lj WW WJJ Lq Lq Ui iy) W APPROXIMATE FINISH D i A W _j ---GRADE- 0 GENTERU fl ,A ' . I - f I 0 cow .................. ................... ........... ............. ............ IN� 8'SINV. 8-S :A1 tIN. 18"D -EWC X. C". _0 Z C1 W z .00 T - 00 rn 10 zo mvm ;> cn C; Z c ZZ >: z ;c- ­. " �� cq 3 zr� 0000 C*4 rt) W) m + 'm C14 U) Uj 11 _j U3 < < i- L -U O'n W INSTALL 15.11 LF Of' 18' RGJ-F !CP 0 -0.1 X� 10+00 11+00 12+00 13+00 14+00 364 362 360 358 356 354 352 350 348 346 344 342 340 338 336 334 LEGEND(CON NO CONSTRUCT STORM DRAIN LINE PER CITY STANDARDS 1. ALL PIPE ELEVA11ONS SHOWN ARE INVERT ELEVATIONS UNLESS OTHERWISE NOTED. CONSTRUCT STORM DRAIN MANHOLE TYPE "A" PER 2. ALL CATCH BASINS TO BE TYPE *A" WITH 3.5' OPENINGS PER C.O.B. STD. SWI & SW -5. C.O.B. STD. D-14, UNLESS NOTED OTHERWISE CONSTRUCT TYPE "A7 CATCH BASIN WITH 3.5' OPENING PER 3. REMOVE ALL EX. TEMP. CLEMOUTS AT THE UNIT BOUNDARY AND CONNECT TO EXISTING SEWER. CONTRACTOR TO VERIFY C.O.B. STD. D-14, UNLESS NOTED OTHERWISE LOCATION AND INVERT OF EXISTING SEWER PRIOR TO S CONSTRUCT SEWER LINE PER CITY STANDARDS CONSTRUCTION AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES. 4. REMOVE CAP & CONNECT TO EXISTING STORM DRAIN ON HIGHGATE CONSTRUCT SEWER MANHOLE TYPE "A" PER C.O.B. STD. SWI GREENS DRIVE. CONTRACTOR TO VERIFY LOCATION AND INVERT OF AND SW -5. EXISTING STORM DRAIN PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER OF ANY DISCREPANCIES. CONSTRUCT SEWER CLEANOUT PER C.O.B. STD. SW -6. 5. ALL SEWER LATERALS SHALL BE e IN SIZE, UNLESS NOTED OTHERWISE. ® /-PIPE SIZE ISISTRUC110N NOTES: � 4"WCO w UTILITY: W -WATER D -DRAIN C,GAS S -SEWER IF PHASES 3 & 4 ARE NOT TO BE CONSTRUCTED SIMULTANEOUSLY, THEN THE DEVELOPER OF PHASE 3 SHALL CONSTRUCT TEMPORARY SECTION DESIGNATION: SEWER CLEANOUT OR STUB & PLUG AS PART OF PHASE 3. SECTION LETTER 2 CONSTRUCT PIPE SADDLE PER C.O.B. STD. D-9 AT LOCATIONS OF Know whafs below. CROSSING PIPES WITH CLEARANCE LESS THAN 12'. TO EXISTING SEWER/STORM DRAIN. CONTRACTOR TO CaII before you dig. 2®CONNECT VERIFY LOCATION AND INVERT OF EXISTING SEWER/STORM DRAIN SHEET WHERE SECTION IS SHOWN PRIOR TO CONSTRUCTION AND NOTIFY THE ENGINEER OF ANY 14 DISCREPANCIES. r) -70f%r) ML, 0 0 A 00 III