Loading...
HomeMy WebLinkAbout1.8-7248 Ph 3MEN ff Ci 1 12 LOT LINE LOT LINE V-6.1 w GSTC STUB\ 0 L - 1 FT / \ N WATER METER MAIN TRENCH a 0 LOT LINE II TYPICAL INTERIOR STUB INSTALLATION NO SCALE THIS CROSS SECTION IS REPRESENTATIONAL ONLY. ANY PARTY EXCEEDING ITS SPACE ALLOTMENT SHOULD MAKE ARRANGEMENTS TO ENSURE THAT THE TRENCH WILL ACCOMMODATE THE ADDED CONDUITS OR DUCTS. F- 24" -1 FINISH GRADE IF R/W R/W GAS TO GO ON SIDE OF TRENCH NEAREST THE CURB. 12" MIN. G BOTTOM OF GAS MAIN TO BE 6" ABOVE NOTES: . TOP OF ANY OTHER CONDUIT/DUCT 1. PROVIDE 2" SAND SHADING ABOVE AND T C IN TRENCH B BELOW GAS FACILITIES (MINIMUM) 2. PROVIDE 4" SAND SHADING ABOVE AND " • MINIMUM COVER FOR ANY PARTY BELOW ELECTRIC FACILITIES (MINIMUM).P.S 'R IN THE STREET AREA IS 30" (EXCEPT STREELIGHTS) n _� 1 a 8" MIN. TYPICAL DISTRIBUTION TRENCH (SO—CAL GAS AREAS) NO SCALE 0 N OTE: ALL SERVICES AND SUB—STRUCTURES ARE NOT TO SCALE FOR CLARITY. ALL COMPONENTS SHALL FIT WITHIN THE PUE OR FRANCHISE AREA UNLESS OTHERWISE NOTED. REFER TO DETAILS FOR LOCATIONS. SUBSTRUCTURE VERIFICATION STAMP DEVELOPER PLEASE NOTE AND SIGN ALL P.G.& E. ENCLOSURES AND BOXES HAVE BEEN SET TO GRADE ACCORDING TO GRADE STAKES PROVIDED BY DEVELOPERS ENGINEER. ALL COSTS TO RELOCATE OR RE -ADJUST BOXES AT A LATER DATE WILL BE BILLED TO THE DEVELOPER. PLEASE HAVE YOUR JOB SUP. VERIFY THE CORRECTED GRADE OF ALL ENCLOSURES AND BOXES. AND SIGN AND DATE DRAWING. THANK YOU SIGNED DATE 10' PUE J NN D_ PAD -MOUNTED EQUIPMENT SUBSURFACE ENCLOSURE 3 O 16' %' 6 7 8 W 12' z J 0_ zZ W U TRENCH CENTERLINE (1' UNDER WALK) SUBSURFACE J TRENCH ENCLOSURE/VAULT CENTERLINE WOODLAWN WAY NO SCALE 18" MIN FINISH GRADE MIN. 59-1/2" MIN. T T C C 8" MIN. 0 1) 2" SAND SHADING AROUND GAS & ELECTRIC IF NATIVE SOIL IS NOT ROCK FREE 2) SEE OTHER DETAIL IF NON -PG&E STREETUGHT IS IN TRENCH 3) ONLY PARTIES PARTICIPATING IN U.S.A. ARE ALLOWED IN THIS TRENCH MIN. MIN. 2" SHADING TYPICAL SERVICE TRENCH NO SCALE W z J D_ H z W U JOINT TRENCH RECAP TRENCH OCCUPANTS DISTRIBUTION OR SERVICE TRENCH SIZE DEPTH FOOTAGE BACKFILL SURFACE GSTC DIST 24" x 59" 578' SPREAD DIRT GPTC DIST 24" x 59" 281' SPREAD DIRT GPSTC DIST 24" x 59" 511' SPREAD DIRT GSTC SERV FRANCH 18" x 46" 555' SPREAD DIRT GSTC SERV PRIVATE 18" x 46" 230' SPREAD DIRT GSTC SERV COMP. 18" x 46" 975' SPREAD DIRT FOR TRENCH INSPECTION CALL (559) 263-7312 ANY CHANGES TO THIS DESIGN MUST FIRST BE APPROVED BY PG&E. GAS ADE: DOMINIC OTHART PHONE: (661) 398-5817 9 10 GENERAL NOTES: 1. DEVELOPER TO DO ALL TRENCHING, SHADING, AND BACKFILLING. PER UO STANDARD S-5453. 2. PHONE AND CABLE TV FACILITIES ARE SUBJECT TO CHANGE AT THE DISCRETION OF THOSE COMPANIES. 3. PADS, BOXES AND OTHER FACILITES ARE NOT SHOWN TO SCALE. 4. GAS AND ELECTRIC FACILITIES WILL REQUIRE SAND SHADING IF NATIVE SOIL IS NOT ROCK -FREE. PG&E WILL INSPECT BACKFILL MATERIAL. TEL AND/OR CATV MAY ALSO REQUIRE 12" OF SAND BACKFILL. 5. GROUND TO BE WITHIN .2 FT OF FINISH GRADE PRIOR TO TRENCHING. 6. GAS AND ELECTRIC FACILITES REQUIRE AT LEAST 3' OF SEPARATION (1' UNDISTURBED SOIL) FROM PARALLEL RUNS OF WATER, SEWER, OR STORM DRAIN. 7. PRE -CONSTRUCTION MEETING REQUIRED TWO WEEKS PRIOR TO THE START OF INSTALLATION. B. CALL U.S.A. AT LEAST 48 HOURS PRIOR TO TRENCHING (DIAL 811) 9. PG&E WILL ASSIST IN LOCATING ENDS OF EXISTING GAS MAINS. 10. DEVELOPER IS RESPONSIBLE FOR OBTAINING ENCROACHMENT PERMITS.. 11. STREETLIGHT LOCATIONS MAY HAVE CHANGED. REFER TO THE APPROVED STREETLIGHT IMPROVEMENT PLAN FOR STREETLIGHT INSTALLATION. 12. DEVELOPER SHALL CONTACT ALL INVOLVED PARTIES PRIOR TO MAKING ANY CHANGES FROM THIS DRAWING. 13. REFER TO EACH PARTY'S INSTALLATION INSTRUCTIONS FOR MORE PRECISE DESCRIPTION OF SUBSTRUCTURES AND OTHER REQUIREMENTS. I�r�rm w G GAS TELEPHONE P ELECTRIC PRIMARY (661) S ELECTRIC SECONDARY 2. BRIAN FRANZ T TELEPHONE 631-3492 C CABLE TV BRIGHTHOUSE (661) SLASH INDICATES CHANGE IN OCCUPANCY — — — — — PROPOSED SERVICE TRENCH — — PROPOSED MAIN LINE TRENCH EXISTING UNDERGROUND FACILITY L2� PROPOSED #2 (17" x 30" x 18") ELECTRIC SPLICE BOX LKj PROPOSED #2E (17" x 30" x 26") ELECTRIC SPLICE BOX [3] PROPOSED #3 (24" x 36" x 18") SECONDARY ELECTRIC SPLICE BOX [E] PROPOSED #3E (24" x 36" x 26") SECONDARY ELECTRIC SPLICE BOX LTJ PROPOSED TELEPHONE PEDESTAL\SPLICE BOX O d+ Lc] PROPOSED CABLE SPLICE BOX Wj PROPOSED PAD MOUNTED TRANSFORMER PST 10 INDICATES TRENCH FOOTAGE & OCCUPANCY ,r---�� PROPOSED LS 2A STREET LIGHT LOCATION (SEE NOTE 11) W L �- PROPOSED SERVICE LOCATION MINIMUM COVER AND CLEARANCES* COMPANY TELEPHONE 1. LES INGLES P G & E (661) 398-9755 12" - 1" 2. BRIAN FRANZ AT&T (661) 631-3492 ELEC. SEC. 3. GREG EOFF BRIGHTHOUSE (661) 395-3351 3" - 30",36" STREET 4. LEON WELLS THE GAS CO. (661) 399-3215 MINIMUM COVER AND CLEARANCES* NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL DRAWINGS FOR ELECTRIC FACILITY PLACEMENT, DETAILS, AND CLEARANCES. VICINITY MAP ■ 1.8-7248 Ph 3 O Q D w CJ 0 OF W L� L_ O D L� L� O O LH C, W Q m m W L_ 1T O UL O O O z� L_OF W C X0.�111 F�1 W N W I H - w W [n C> O O G T C S P COVER GAS - 12"12" 6" 12" 24" 30" IN STREET TELE. 12" - 1" 12" 12" 24".30" STREET CAN 12" 1" - 12" 12" 18" ELEC. SEC. 6" 2" 12" - 3" 24",30" STREET 30" IN STREET ELEC. PRI. 12"12"12* 3" - 30",36" STREET STREETLIGHT 6" 12"12" 1" 3" SEE EX.B FIG.1 NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL DRAWINGS FOR ELECTRIC FACILITY PLACEMENT, DETAILS, AND CLEARANCES. VICINITY MAP ■ 1.8-7248 Ph 3 O Q D w CJ 0 OF W L� L_ O D L� L� O O LH C, W Q m m W L_ 1T O UL O O O z� L_OF W C X0.�111 F�1 W N W I H - w W [n C> O O O U M o � M rn o 4 O Z a� t O N o CD S LN Ln 6' � Lf7 d z o n � � o z O wap rn C � , 00 cn y x N zrn rn p m U H - GO -. p O d+ =a a C\2 Q �mm) ai co x Ld W L Z CD U m C! a m m Q I bi 0 ' Q Ln U r O S M C:) z H w Lil O � U O Q Q d w z 'Z 2 o IL U U a 0 D 4 N U v Q E z o f� Q U wap C O z� 00 C x LaJ zrn rn p m U H - C= p O d+ z C\2 Q v m Z` Ld W L Z In Q U rn m Q H ' Q Ln U r O S M C:) LLJ Lil U O Q Q d Q O 2 IL U U a w D 4 N 5 4 3 2 1 INCH 0 Q f� Q wap z� LLJ x J p m U � C= p O d+ z C\2 Q J m Z` Ld W L Z In Q CC Ld H L Q m S 5 4 3 2 1 INCH 0 23 / / 22 15 \ / / 16 17 18 4 3 4 5 6 7 8 D s / \ *4FNg \` \ \ o il? ss \ \ sa s 5 CSF / K,qSOss / SD \ ss 4 SUMP Ot yy 39 / Z� LOT B I 38 TIE INTO N ��/ EXISTING JT j I z J�v 37 & 0 s / L GSTC �— -- — —� / k- 260, I 36 10' 6 Ni \ W PUE > / \ / 3 \ 10' / 35 Aj � Ga1c I I L? / / ✓� ss \� PUEPST ^_o/ 34 I 4 W 63 PST 0PUE I o s I W \ / GPTC 13 33 w o 32 N N I I / PST 31 / ti f ss 1' / N, r �� I 1100' ti GSTC f N l 19 / 22 0� R\ s1' S ti 20T — r-, l o' 23 �� ss �. d LgNE so 1. FTJ Pu 10' ss TIE INTO 24 PUEss I / EXISTING JT o 3 / �/ GSTC o � � _ n 58 GSTC so / 21 � 25 /ice "' 58' oQ-S 03 3 O� s o Ss GPTC ��y� ° \ \ 0 26 40' y` 20 SSV 03 3 / 27 W 1� I 28 29 IN (EXIST.)1 , \ \ � � 19 // o t I^ 30 f' � _ I I ,wT S� 18 ice/ 3 3 3 3 h °o 0o w \ PST �a/ 249' 3t 17 — 0 I / � o— \ / hp�� s 1 / 16 =W I lo' �j 10' 10' _�/ 15 14 0l °w PUE I ss �,~,r PUE R I I w \ of 13 Inti I i 4' 1SS �1 I-_� 6 666' ' N Imo 12 0 �/ GSTC 2 \ \ 60 \/ T1 / 141 N I o ° / 'L_ 3 GPTC I a W \ 72'SS 1 LAN fs — 4' 1' I \ Zss 4 / � � � �v, I II ss � I s I lo'� \ 0 5 /° PUE 25 / 8 IZS W� I o W O K O U \ / 26 \ IOW 9 1 10 h� 11 I I LO i I ' J / 27 / / RESIDEN_ _ PUE f / 28 AL — I a / — Z ss / 29 -- W �-- zN I // 30 / _ LANE < SS so C'gMpUS\ ss / 31 / a \ / 32 1 33 34 I I 1 35 36 i 37 1 I \ ss I \ DRIVE ss I \ 1 ss S5. 3 \ / \ 2 \ w� 21 \ 22 \ \ 23 s 24 NOTE: ALL SERVICES AND SUB -STRUCTURES ARE NOT TO SCALE FOR CLARITY. ALL COMPONENTS SHALL FIT WITHIN THE PUE OR FRANCHISE AREA UNLESS OTHERWISE NOTED. REFER TO DETAILS FOR LOCATIONS. NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL DRAWINr'� FnR FI Fr.TRIn FAnII ITY PI Ar.FMFNT DFTAII S AND C'.I FARANC.F4 0 N N CAMPUS N N w N ss ss ss ss W. H 9 10 1 6T RK DRIVE 55 _ SCALE: 1"=50' - 50' 0'��� 1.8-7248 Ph 3 6 5 4 3 N W J.- = w w x M o N Lf7 M U CD oa O C> C-) C5 C) U U Z O N d z o CIO y N t4 GO -. E- CD U m C m eD H � N Z E- G4 w ;k oc> �n w � z z ix O Z O � C O U °o LLL r rn rn r p Q n o m c U r u m � I U O Q Q o Q 2 d U U a w D Q fn 0 2 1 INCH 0 a N Q W Q � � Z O w x J p m U to � o ^o C\2 Q Q1 r— W M w � Z E� LLJ Q m o z U U w Z 0 o_ 0 2 1 INCH 0