CORRECT ALL VIOLATIONS.; VIOLATION
'REQUIREMENTS
CHECKED BELOW NO,
1
Remove and safely dispose of all hazardous refuse and dry vegetation on.the above premises (CFC
COMBUSTIBLE WASTE / DRY
3 0.4.1.1
VEGETATION
2
Provide non - combustible containers with tight fitting lids for the storage of ,comb.ustible waste and
rubbish pending its safe. disposal. .(CFC 304.3.2) Note: applies to' containers 'over. 40 gallons.
COMBUSTIBLE STORAGE
3
Relocate combustible storage to provide at least.3 . feet clearance around motor fuse box/fire-door (CFC
605:3)
- 4
Relocate fire extinguisher(s) -so that they will be in a co'nspicuo:us location,. hanging on' brackets with the
top to the extinguisher not more than 5' feet above the floor. (CFC 906.5 & 906.9)
EXTINGUISHERS
5...
Provide and install (amount) ----- approved (type & size) -------------- Portable fire
extinguisher to be immediately accessible for use in, (area) ___ ___ _____ ___ _ __ —_!— (CFC
.
..TABLE 906.3)
M 6
Re- charge 'a 1.1 fire extinguishers. Fire extinguishers shall be serviced at Feast .once each year, and /or
, .
_.
i
after each use;. by a person haying 'a valid license or ceef` icf ate.
7
Provide and maintain "EXIT" sign(s), with letters 6 or more inches in height over each required exit'
SIGNS
(door /window) to fire escape. (CFC 1011) `
8
Provide and maintain. appropriate numbers on a contrasting background and visible from the 'street to
indicate the correct.. address of the building. (CFC 505.1)- ;
g
''Repair all (cracks/holes/openings) in plaster. in (location) _____________________ _ M
FIRE DOORS
Plastering shall return the surface to lts original fire "resistive condition. (CFC 703.1)
FIRE SEPARATIONS
10
Remove/repair (item. & I o cation) -------=----------- - = - - -- —=------------=-=-----------
S61f- closing doors shall be designed to close by gravity, or. by the action of a mechanical device, or by an
approved smoke and heat sensitive device. Serf- closing doors shall have no attachments capable of
preventing the operation of the `closing device. (CFC 703.2)
1�1
Remove all obstruction from hallways. Maintain all means, of egress free of any storage. (CFC.1031.1)-
-
EXITS
12
Provide a contrasting colored and permanently installed electric light over or near, required exit
(location)" ____________________ __ __ __ to clearly indicate it as an .exit. (CFC 1008)
-
Remove al.l storage and /or other obstructions from fire escape landings and' stairways stair shafts. (Fire.
STORAGE
13
escapes /stair shafts are to be maintained free from obstructions at'aII times.) (CFC 1003.6)
i4
Extension :cords shall not be. used in lieu of permanent approved wiring;. Install additional approved
ELECTRICAL APPLIANCES
electrical : outlets, where..needed. (CFC'.605.5)
15
Remove multiple attachment cords from specific.electrical convenience outlet (one plug per outlet) (CFG
605.4) .
OUTDOOR BURNING '.
16
Recreational fires or open burning. CFC 307.1
FIREWORKS1
Violations of Section (CFC. 5608.1)'& 8.44.040 ('B.M.C.).
OTHER
z '
4"
rz `..
kyr'"
CORRECTION DATE
torrect'thO: violations noted above. by:
CUSTOMER:
LEGEND:
CFC CALIFORNIA FIRE CODE
G.B.C. CALIFORNIA BUILDING CODE
ignat .re) (Please Pri 'Na a egibly,'fitl6l,
B.M.C. BAKERSFIELD MUNICIPAL CODE
`:�;�, NO.:
N. .P NATIONAL FIRE PROTECTION.
P.A
INSPECTOR: 11''
ASSOCIATION
1
N.E.C. NATIONAL ELECTRIC CODE
White — Customer /Original Yellow - Station Copy Pink — Prevention. Services
FD 2022 (Rev. 10/2017)