HomeMy WebLinkAboutFIRE SAFETY INSP 11-6-18FACILITY ADDRESS 4« � DATE - i � E FEE FACILITY. NAME _ w ( �✓ CITY, STATE, ZIP BUSINESS OWNER'S.NAME °AND ADDRESS MANAGER'S NAME - PH NO. BILL TO:. (IF DIFFERENT FROM ABOVE) NAME, ADDRESS CITY, STATE, ZIP PH, NO. OCC TYPE OCC LOAD NO. OF FLOORS _ OCC USE RISER DATE Wet /Dry Sprinkler System Type of Alarm System . CONSTRUCTION TYPE HIGH RISE BLDG SQ /FT OF BLD ❑ YES ❑ NO CORRECT ALL VIOLATIONS VIOLATION. REQUIREMENTS CHECKED BELOW NO. i 'Remove anal safely dispose of all hazardous refuse and dry vegetation on the above premises .(CFC COMBUSTIBLE WASTE / DRY 304.1.1 ) VEGETATION . 2 Provide non - combustible containers with tight fitting.lids for the storage of combustible waste and rubbish "pending its safe disposal. (CFC 304.3.2) Note: applies to containers' over `40: gallons. COMBUSTIBLE STORAGE 3 Relocate combustible storage to provide at least 3 feet clearance, around motor fuse box /fire door, (CFC 605.3) °• 4 Relocate fire e.xtinguisher(s).so that they will be in.a conspicuous location, hanging on 'brackets. with the top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9) EXTINGUISHERS 5 Provide and install (amount) a e & size - ( ) - - - -- approved roved (t y P ) --- .--------- ------ Portable fire . extinguisher to be immediately accessible for use 'in (area) ------------ _ __ ________ __ (CFC :;,TABLE 906.3) 6 Re- charge all fire extinguishers.. Fire extinguishers shall be serviced at'least once each year, and /or after each use, by a person having a -valid license or certificate. -(CFC 906:2) z Provide and maintain "EXIT" sign(s) with letters 6 or more inches .in height over each required: exit SIGNS (door /window) to fire escape. (CFC 1011): a Provide and maintain appropriate numbers on a contrasting background and visible from the street to indicate the correct address of the building. (CFC 505.1) 9 Repair all (cracks /holes /openings) in plaster in (.location) ___------------------ --- _----------- . FIRE DOORS / Plastering shall return the surface to its original fire resistive.condition.. (CFC 703.1) FIRE SEPARATIONS 10 Remove /repair (item & location) --------------------------- --------- - - - - -- - Self - closing doors. shall be.designed to` close 'by gravity, or by the action of a mechanical device, or by approved smoke and heat sensitive device. Self- closing doors. shall have no attachments capable of . preventing` the operation of.the closing device: (CFC 703.2) 11 Remove all obstruction from hallways. Maintain -all means of.,eg.ress free of any storage. (CFC t031.1) EXITS 12 Provide a contrasting colored and. permanently installed electric light over. or near required exit (location) --- --- -- ---- ----- ---- - - -- -- --- to clearly indicate it as an exit. (CFC 1008) - STORAGE 13 Remove all storage and /or other obstructions from fire- escape Landings and stairways stair shafts. (Fire escapes /stair shafts. are to be maintained - free-from obstructions at all time.s.) (CFC 1003.6) 14 Extension cords shall.. not be used in lieu, of permanent approved wiring. Install additional approved ELECTRICAL APPLIANCES electrical outlets where needed. (CFC'605.5) ' .15 Remove multiple attachment cords. from specific electrcal.convenience outlet (one plug per outlet) (CFC 605.4) OUTDOOR BURNING '' 16 Recreational'. fires or open burning. CFC 307.1 FIREWORKS 17 Violations of Section (CFC 560:8.1) & 8.44.040 (B:M.C..), OTHER ]$ CORRECTION'DATE Corr.e t the violate np npted above by ?. "�' • . _ �Z:f'°� " F LEGEND: CUSTOMER: >.i' �}''';. �.» _.Y`qp� C.F.C. CALIFORNIA FIRE CODE C.B.C. CALIFORNIA BUILDING CODE (Signature) (Please Print Name Legibly, Title) B.M.C. BAKERSFIELD. MUNICIPAL CODE INSPECTOR:, - "� ` �"�- N.Q.: a . N.F.P.A. NATIONAL FIRE PROTECTION,' . ,� "" ASSOCIATION d` N.E.C. NATIONAL ELECTRIC CODE . White Customer /Original Yellow- Station Copy, Pink - Prevention. Services' Fa 2022.(Rev.10/2017)