HomeMy WebLinkAboutFIRE SAFETY INSP 8.22.18ELECTRIC :CODE White - Customer /Original Y Yellow - Station Copy P Pink - Prevention Services FD 2022 (Rev. 10/2017) , FACILITY ADDRESS ) , DATE . t"s �^^ FE ^+ FACILITY NAME CITY, STATE, ZIP 1V\4_,` t l Y BUSINESS OWNER'S NAME AND ADDRESS MANAGER'S NAME } Pg�H',�'N' . BILL TO: (IF DIFFERENT FROM ABOVE) NAME, ADDRESS CITY, STATE, ZIP PH NO.' OCC TYPE OCC LOAD NO. OF FLOORS OCC USE �+ RISER DATE Wet /Dry Sprinkler System Type of Alarm System e 1 -7" CONSTRUCTION TYPE - ! HIGH RISE BLDG SQ /FT OF BLD ❑ YES [I NO r CORRECT ALL VIOLATIONS VIOLATION REQUIREMENTS CHECKED BELOW NO. 1 Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises (CFC COMBUSTIBLE WASTE / DRY 304.1.1) VEGETATION 2 Provide non - combustible containers with tight fitting lids for the storage of combustible waste, and. rubbish pending its safe disposal. (CFC 304.3.2) Note: applies to containers over 40.gallons. COMBUSTIBLE STORAGE 3 Relocate combustible storage to provide at least 3 feet clearance around motor fuse box /fire door.(CFC 605..3) 4 Relocate fire extinguisher(s) so that they will be in a conspicuous location, .hanging on brackets with the top to the extinguisher. not more than 5 feet above the floor. '(CFC 906.5 & 906.9) . EXTINGUISHERS 5 Provide and install (amount) _____ approved (type & size) ___ _____ ____ ___ ___ portable fire extinguisher to be immediate) accessible. for use in (area) ____________________ (CFC y --- - - - - -- TABLE 906:3) ` 6 Re- charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and /or after each use, by a person having a valid license or certificate. (CFC 906:2) Provide and maintain "EXIT" sign(s) with letters 6 or more inches in height over each .required exit SIGNS (door /window) to fire escape. (CFC 1011) $ Provide and maintain appropriate numbers on a contrasting background and visible from the street to indicate the correct address of the building. (CFC 505.1) 9 Repair all (cracks /holes /openings) in plaster in (location) - ---- - - - - -- FIRE DOORS Plastering shall return the surface to its original'fire resistive condition. (CFC 703.1) FIRE SEPARATIONS 10 Remove /repair (item & location) ---- - - - - -- ----------------------------------------- - - - - -- Self- closing doors shall be designed to close by gravity, or by the action of a mechanical device, of an approved smoke and heat sensitive device. Self- closing doors shall have no attachments capable of preventing the operation of the closing device. (CFC 703:2) 11 Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1031.1) . EXITS 12 Provide a contrasting colored and.permanently installed electric light over or near required exit (location) ____- _ ____ to clearly indicate it as an exit. (CFC 1008) 'STORAGE 13 Remove all storage and /or other obstructions from fire esca pe. landings and stairways stair shafts. (Fire escapes /stair shafts are to be maintained free.from obstructions at all times.) (CFC 1003.6) 14 Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved ELECTRICAL APPLIANCES electrical outlets where needed. (CFC 605.5) 15 Remove multiple attachment cords from specific electrical convenience outlet (one plug. per outlet) (CFC 605.4) . OUTDOOR BURNING 16 Recreational fires or open burnin . CFC 307.1 FIREWORKS. 17 Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.). OTHER ' 1$ CORRECTION DATE Correct the violations noted above by: ' i -,. LEGEND: �. t �;, 1 �,. C.F.C. CALIFORNIA FIRE CODE . CUSTOMER: ' (Signature) (Please Print Name Legibl Title) C.B.C. CALIFORNIA BUILDING CODE B M.C. BAKERSFIELD MUNICIPAL CODE �""� N F.P.A. NATIONAL FIRE PROTECTION INSPECTOR.:,. �,,,' ,�`�' NO.: AssocxATloN N.E.C. NATIONAL White - Customer /Original Y Yellow - Station Copy P Pink - Prevention Services FD 2022 (Rev. 10/2017) ,