Loading...
HomeMy WebLinkAboutFIRE SAFETY INSP 10-1-18FACILITY ADDRESS � DATE FEE FACILITY PAM E �w CITY, STATE, ZIP r ,. BUSINESS OWNER'S NAME AND ADDRESS MANAGER'S NAME PH NO. BILL TO: (IF DIFFERENT FROM ABOVE) NAME, ADDRESS CITY, STATE, ZIP PH NO. OCC TYPE r"+• +{e • NO. OF FLOORS OCC USE DATE OCC LOAD tr a h x I5 c ti x ,r R j� i' t � ''i �+ FL,; [�;. t."4.. • c 'i.: ! &wr•.: .f.P3 /°1 ,. .3 Cam•% N •.ws Type of Alar System �,� CONSTRUCTION TYPE i' A. "i<" _ HIGH RISE BLDG SQ /FT OF BLD OYES NO Wet/ Dry. Sprinkler System A—I �° ,- REQUIREMENTS CORRECTALLVIOLATIONS VIOLATION CHECKED BELOW No. Remove. and safely dispose of all hazardous refuse and dry vegetation on the above premises (CFC COMBUSTIBLE' WASTE 7 DRY - 1 3 04., 1. 1`) i VEGETATION Provide no containers with tight fitting lids for the storage of combustible waste and 2 rubbish pending its safe disposal. (CFC 304.3.2), Note: ,,applies to containers over 46 gallons.. : Relocate combustible storage to provide, at least 3 feet clearance around motor fuse box /fire door• (CFC COMBUSTIBLE STORAGE 3 605.3) 4 Relocate fire extinguishe.r:(rs) so that they. Will be`.in a conspicuous Location, hanging on brackets with the top to. the extinguisher not more than 5.feet above the floor. (C:FC 906.5 & 906.9) EXTINGUISHERS' S• "Provide and install (amo;unt):_ approved (type &size) _ ----- _portable fire (CFC extinguisher to be immediately accessible for use in (areal _ __ - - --- -- -- ---- - --- TABLE 906.3) - `� ° 6, Re- charge all fire extin uishe`rs. Fire extinguishers shall be serviced at least once each year; and /or 9 after each use, by a,person. having a valid license or certificate., (CFC 906.2) Provide and maintain "EXIT" signs) with letters 6 or more inches in height over each required exit. SIGNS �. ( door /wi'ndow) to fire escape. .(CFC 101,1) Provide and maintain appropriate numbers on a contrasting" background and visible from the street to g indicate th.e correct, address of the building. (CFC 505.1) g Repair (cracks /holes /openings) in, plaster in (location) -- --- --- - ----- - ---- ---- -- - - -- - - FIREDOORS/ ,all Plastering .shall return the surface to its original fire resistive condition. (CFC 703 1) FIRE SEPARATIONS, 10 Remove /repair (item &location) ---------------- -------=- '--------- - - - - -- - Self- closing doors shall be designed to close by gravity, or by the action of a mechanical device, or by an approved smoke and heat sensitise device. Self - closing doors shall have no attachments capable of preventing the operation of the closing device`. (CFC 703.2) 11 Remove all obstruction from hallways. :Maintain all means of egress free of any .storage. (CFC 1031.1) EXITS 12 Provide a contrasting colored and permanently installed electric light over or near required exit (location) ----- _- _---- ---- -- -- ---- - -- to clearly indicate it as an exit. (CFC 1008) Remove all storage and /or other obstructions from fire escape l.andin,gs and stairways stair shafts. (Fire STORAGE 13 escapes /stair. shafts are to be maintained free from obstructions at all times.) (CFC 1003.6) Extension cords shall not be used in lieu of permanent approved wiring'.. Install additional approved ELECTRICAL APPLIANCES 14 electrical outlets where needed. (CFC 605.5) is Remove multiple attachment cords from specific electrical: convenience outlet (one plug per outlet) (CFC 605.4) Recreational fires or open burning. CFC 307.1 OUTDOOR BURNING: 16 FIREWORKS 17 Violations of Section (CFC 5608.1) & 8.44.04.0 (B.M.C.). . . OTHER 18 Pl 'T,: r chic, CORRECTION DATE Corr ct e .violations noted above b4:4 LEGEND: "` C.F.C. CALIFORNIA FIRE, CODE CUSTOMER: ,f- - Signur (Please Print Name Legibly, Title) C.B.C. CALIFORNIA BUILDING CODE: B.M.C. BAKERSFIELD MUNICIPAL CODE 1 N.F.P.A. NATIONAL FIRE PROTECTION NO.: ---=�— ASSOATION INSPECTOR: �t a CI N.E.C. NATIONAL ELECTRIC CODE White Customer /Original Yellow - Station Copy Pink'- Prevention Services FD 2022lRev. 10i2017)