Loading...
HomeMy WebLinkAboutFIRE SAFETY INSP 7-23-18BAKERSFIELD FIRE DEPARTMENT FIRE PREVENTION INSPECTION Prevention Services 2101 H Street B akersfield,, CA 93301, Phone: 661 - 326 -3979 *_Fax: 661- 852 -2171 FACILITY ADDRESS DATE 7 FEE , FACILITY NAME CITY, STATE, ZIP 3 BUSINESS OWNER'S NAME AND ADDRESS MANAGER'S NAME PH - NO. BILL TO; (IF DIFFERENT FROM ABOVE) NAME, ADDRESS city, STATE, ZIP PH NO., OCC TYPE OCC LOAD NO. OF FLOORS OCC USE FA.I. RISER DATE 0 A,1 Wet/Dry Sprinkler System Type of Alarm System CONSTRUCTION TYPE HIGH RISE BLDG �YES NO SQ/FT OF BLD A J OL ❑ -A= CORRECT ALL VIOLATIONS VIOLATION REQUIREMENTS CHECKED BELOW NO. Remove and safely dispose. o, f all hazardous refuse and dry vegetation on the above premises (CFC. COMBUSTIBLE WASTE DRY 304..1.1) VEGETATION 2 Provide non-combustible containers with tightfitting lids for the storage of..comb,ustible waste anal rubbish pending, its safe disposal. (CFC 304.3.2) Note: applies to containers over 40 gallons. :10 COMBUSTIBLE STORAGE 3 Relocate combustible storage to provide at least 3 feet.clearance around motor fuse box/fire door (CFC 605.3). 4 Relocate fire extinguisher(s) so that they will be in a conspicuous location,, hanging, o ri brackets, with the top to the extinguisher not more than 5 feet. above the floor. (CFC 906.5 906.9) EXTINGUISHERS Provide and instal] (amount), approved (type� & size) --- ------ portable fire extinguisher to be immediately accessible for use in, (area) --- 7 ----------- ------ ---- (CFC TABLE 906.3) 6 Re-charge all fire extinguishers. Fire extinguishers shall be serviced at least once, each year, and/or after each use,. by a person having a valid license or certificate. (CFC 906.2) Provide and maintain "EXIT" sign(s) with letters.6 or more inches in height over each required exit SIGNS 7 (dPor/window) to, fire escape. (CFC 1011) Provide and, maintain - appropriate numbers on .a contrasting background and visible from the.'stree.t to indicate the correct address of the building. (CFC 50.5.1) 9 Repair all (cracksfhbles/openings) in plaster in (location) -------------------------------- - FIRE DOORS/ Plastering shall return the.. surface to its original fire resistive condition. (CFC .,.703.11) FIRE SEPARATIONS jo Remove/repa ir (item & location) --------------------------- - - - = -- -------------- - - - - -- Self-closing doors shall be designed to chose by gravity, or by the action of a mechanical device, or by an approved smoke and heat sensitive device. Self-closirig doors. shall have no attachments capable. of preve,nting,the operation. of the closing device., (CFC 7,03-2) 11 Remove all obstruction from hallways. Maintain all means.o.f egress free of any storage. (CFC 1031.11) EXITS 12 Provide, a contrasting co.lored and permanently installed electric light over or near required exit (location) --- ---- ------ ----- ---- -- - --- -- I to clearly indicate it as an exit. (CFC 1008) Remove all storage and/or other obstructions from fire escape landings and stairways stair shafts. (Fire STORAGE 1 3 escapes/stair shafts are to be maintained free from obstructions at all times:)' (CFC I 003.6) Extension cords shall not be used in, lieu of permanent approved, wiring. Install additional approved ELECTRICAL APPLIANCES 14 electrical outlets where needed. (CFC 605.51) is Remove*multiple attachment cords from specific electrical convenience outlet (one. plug per outlet) -(CFC 605.4) OUTDOOR BURNING 16 Recreational fires or.open burning. (CFC 307.1) FIREWORKS 17 Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.). OTHER 18, r CORRECT-ION D 'Correct the violation)s noted above P 10C OMER Z� CUSTOMER. LEGEND: RE C.F.C. CALIFORNIA F1 CODE' B.C. CALIFORNIA BUILDING. CODE -0-y, TitA (Sighature) 'i-kirase-P'rint Name Leg B.M.C. BAKERSFIELD MUNICIPAL CODE N.F.P.k, _NATIONAL FIRE PROTECTION INSPECTOR: NO.: ASSOCIATION N.E.0 . NATIONAL ELECTRIC CODE p White - .Customer /Original Yellow - Station Copy Pink - Prevention Services FD 2022 (R6. 10/2017)