HomeMy WebLinkAbout2929 E Brundage 989 Re-test 2017Testing and Inspection Certificate Tanknology Inc. 11000 North MoPac Expressway, Suite 500, Austin, TX 78759 800-800-4633 www.tanknology.com Page 1 of 1 Test Date 12/6/2017 Tanknology WO#SC1-3437459 Test Purpose COMPLIANCE Customer PO# Customer Location PENSKE TRUCK LEASING P.O. BOX 7635 READING, PA 19603 PENSKE CA-094 (CA-094/0198-10) 2929 E. BRUNDAGE BAKERSFIELD, CA 93307 Attn: BRIAN YAZEMBOSKI Attn: Jorge Or David (610) 603-8450 (661) 322-3146 Test / Inspection Description Item Tested Date Tested Result Dispenser Containment (UDC) See test report for details 12/6/2017 Pass Tanknology Representative: JEFFREY KERTIS Technician: Franscico Castro Telephone: (800) 964-0010 Technician Certification: (See forms) SWRCB, January 2002 Page 1 of 1 Secondary Containment Testing Report Form This form is intended for use by contractors performing periodic testing of UST secondary containment systems. Use the appropriate pages of this form to report results for all components tested. The completed form, written test procedures, and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: PENSKE CA-094 Date of Testing: 12/6/2017 Facility Address: 2929 E. BRUNDAGE , BAKERSFIELD, CA 93307 Facility Contact: Jorge Or David Phone: 661-322-3146 Date Local Agency Was Notified of Testing: 12/28/2017 Name of Local Agency Inspector (if present during testing): peter 2. TESTING CONTRACTOR INFORMATION Company Name: TANKNOLOGY INC. Technician Conducting Test: Franscico Castro Credentials: CSLB Licensed Contractor SWRCB Licensed Tank Tester License Type: A / UT License Number: 743160 / 8026747 Manufacturer Manufacturer Training Component(s)Date Training Expires VPLT PRECISION EQUIPMENT 2/1/2019 3. SUMMARY OF TEST RESULTS Component Pass Fail Not Tested Repairs Made UDC # 2 Sat/ X UDC # 2 Sat/ X Component Pass Fail Not Tested Repairs Made If hydrostatic testing was performed, describe what was done with the water after completion of tests: CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING To the best of my knowledge, the facts stated in this document are accurate and in full compliance with legal requirements Technician's Signature:Date:12/6/2017 WO: 3437459 SB 989 TEST WATER LEFT ONSITE. SWRCB, January 2002 Page 1 of 1 7. UNDER-DISPENSER CONTAINMENT (UDC) TESTING Test Method Developed By: UDC Manufacturer Industry Standard Professional Engineer Other (Specify) Test Method Used By: Pressure Vacuum Hydrostatic Other (Specify) Test Equipment Used: VPLT Equipment Resolution: 0.00001 in. UDC Manufacturer: UDC Material: UDC Depth: Height from UDC Bottom to Top of Highest Piping Penetration: Height from UDC Bottom to Lowest Electrical Penetration: Condition of UDC prior to testing: Portion of UDC Tested1 Does turbine shut down when UDC sensor detects liquid (both product and water)?* Turbine shutdown response time Is system programmed for fail- safe shutdown?* Was fail-safe verified to be operational?* Wait time between applying pressure/vacuum/water and starting test Test Start Time: Initial Reading (RI): Test End Time: Final Reading (RF): Test Duration: Change in Reading (RF-RI) : Pass/Fail Threshold or Criteria: Test Result: Was sensor removed for testing? Was sensor properly replaced and verified functional after testing? UDC #2 Sat ENVIRON Fiberglass 32.00 6.00 8.00 OK 4"ABOVE Yes No NA 00:00:00 sec Yes No NA Yes No NA 15 min 08:40:00 0.37870 in. 08:55:00 0.37800 in. 15 min -0.00070 in. +/- 0.00200 Pass Yes No NA Yes No NA UDC #2 Sat ENVIRON Fiberglass 32.00 6.00 8.00 OK 4"ABOVE Yes No NA 00:00:00 sec Yes No NA Yes No NA 1 min 08:56:00 0.37800 in. 09:11:00 0.37700 in. 15 min -0.00100 in. +/- 0.00200 Pass Yes No NA Yes No NA UDC # Yes No NA sec Yes No NA Yes No NA min +/- Yes No NA Yes No NA UDC # Yes No NA sec Yes No NA Yes No NA min +/- Yes No NA Yes No NA Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) 1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an asterisk (*) is "NO" or "NA", the entire UDC must be tested. WO: 3437459 INSPECTOR ONSITE. Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:3437459 Site ID / Name:CA-094/0198-10 / PENSKE CA-094 Address:2929 E. BRUNDAGE City:BAKERSFIELD State:CA Zip:93307 W.O.# SC1-3437459