Loading...
HomeMy WebLinkAboutFIRE SAFETY INSP 12-6-18'�'. t�+%t:Jl.. �. L :::.�4;;'i,.� %' _.[.f4:::7i"L..°`�n �, , : �+^':.� ..� - F .�' ; ` ,,/•r t�",...��..a+d.:�� � �r"..;..7' BUSINESS OWNER'S NAME AND.ADDRESS MA�.NAGER'S N ME PH NO. ' .BILL TO: (IF DIFFERENT FROM ABOVE) NAME, ADDRESS CITY, STATE; ZIP PH NO. OCC TYPE OCC LOAD NO. OF FLOORS. OCC USE RISER DATE yLEGEND: CUSTOMER: /: Wet /Dry Sprinkler System: -0 ysk,e��;q Alarm System CONSTRUCTION TYPE HIGH RISE B DG SQ /FT OF BLD INSPEC TOR: y NO.: B M.C. - N F.R.A. N.E;C. ❑YES a . NO CORRECT ALL VIOLATIONS VIOLATION REQUIREMENTS CHECKED BELOW No. .. 1 Remove and safely dispose Hof all hazardous refuse 1 and dry vegetation on the above premises (CFC COMBUSTIBLE WASTE /`DRY 304.1.1) VEGETATION 2 Provide non - combustible containers with tight fitting lids for the storage of combustible waste and rubbish pending its safe disposal. ( CFC 304:.3.2)" Note.: applies to. 'containers over 40 gallons. - COMeusTZBLE :STORAGE 3 Relocate combustible: storage :. to, provi.de•at least 3, feet clearance around motor fuse:`box /fi're door ;(CFC 605.3 ) q Relocate,;fir,e extinguisher(s), so that` they will be in a conspicuous Jocation, hanging on brackets with the' -` top to the extinguisher not more than 5-feet above'the` floor. (CFC` 906.5 & 906.9) - EXTINGUISHERS 5, Provide and install ( amount a ,proved (,type & size) — -- -- - - - -=- - - -- portable fire extinguisher. to be immediately accessible for use in .(area) __________________ (CFC" TABLE 906.3). s Re- charge all fire extinguishers. Fire: extinguishers shall be serviced at least once each year, and /or after each use, by a person having a valid license or certificate: (CFC .90.6:2) Provide a,nd. maintain "EXIT" sign(s) with letters 6 or more inches in height over each'requ.ired.exit SIGNS (door /w.indow) to fire escape. (CFC 101,1) 8 Provide" and maintain appropriate numbers on a contrasting background a.nd visible from the street to :indicate th'e correct address. of the.building: ;.(CFC 505.1) g Repair all in plaster'in, (lo.cation).____- ________ ____ FIRE DOORS/ Plastering shall return `the surface to its original fire resist iVe: condition. (CFC 703.1)' FIRE SEPARATIONS 10 Remove /repair (item & I o cation) ---------- = - - - -- ------- - - - - == - - -- = = - - - =- - - =- -: =- - Self- closing .doors shall be designed to close by gravity, or by the action of. a mechanical device, `or by -.an approved smoke.and.heat sensitive device.. ,Self - Closing doors shall have no attach ments,ca'paWe of „preventing the operation of the,closing device: (CFC 703:2.) 11 Remove al.l obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1031:1) EXITS .' L Provide a contrasting- colored :and permanently installed electric light over or near required exit _12 (location) ____`_____________________ to clearly. indicate it as an exit. (CFC 1008) STORAGE 13 Remove all'storage and /or other.obstr,uctions from fire escape landings and stairways stair shafts, (Fi're escapes /.s.tai,r shafts are to be maintained free "from obstructions at all times:), (CFC 10.03.6) 14 Extension: cords sh.all not be used .in lieu of permanent,'approved wiring..; Install.additi,onal:approved ELECTRICAL APPLIANCES electrical outlets where needed. (CFC 6,05.5) 15 Remove multiple attachment cords; from .specific'electrical convenie.n :ce outlet '(one plug per outlet) (CFC, 605.4) OUTDOORBURNING 16 Recreational fires or open burning. CFC 307;1 FIREWORKS 17 Violations of Section ;(CFC 5608.1) & 8,.44.040 (13-ft C.).. OTHER 18 CORRECTION DATE .. Corr t the. violationsno.ted above ,by.: #( r yLEGEND: CUSTOMER: /: C F.C. C.B.C.. CALIFORNIA FIRE CODE CALIFORNI,A BUILDING CODE' (Signature) (Please Print N�me • giby; Title) . INSPEC TOR: y NO.: B M.C. - N F.R.A. N.E;C. BAKERSFIELD: MUNICIPAL CODE NATIONAL FIRE PROTECTION ASSOCIATION: NATIONAL ELECTRIC CODE White - Customer /Original. Yellow - Station Copy Pink - Prevention Services FD 2022 (Rev. 10%2017)