HomeMy WebLinkAboutFIRE SAFETY INSPECTION 12.12.18FACILITY ADDRESS, , p
DATE �y _. ,y�
FEE
FACILITY NAME ,.�..: t -' 1 "' �p
CITY, STATE. ZIP;
BUSINESS OWNER'S NAME AND ADDRESS
MANAGER'S NAME _
PH,NO.
BILL TO: (IF DIFFERENT FROM ABOVE) NAME; ADDRESS
CITY, STATE, ZIP 6
PH NO.'
OCC TYPE
OCC LOAD
NO. OF FLOORS
OCC USE
RISER DATE
o.
Wet /Dry Sprinkler System
Type of Alarm System
CONSTRUCTION TYPE ^ e� %
HIGH RISE Si G
SQ /FT OF BLD
� !
�
-
❑YES [31*
r
CORRECT ALL VIOLATIONS VIOLATION
REQUIREMENTS:'
CHECKED BELOW :NO:
1
Remove and safely dispose of all hazardous refuse and dry vegetation on the above prem.is'es (CFG;
COMBUSTIBLE WASTE / DRY'
304.1.1)
VEGETATION
2
Provide non - combustible containers `with tight fitting lids for the storage'o.f combustible: waste and'.
rubbish pending its safe ,disposal. (CFC 304.3.2) . No.to::.applies ,to, containers over 40 gallons.
COMBUSTIBLE STORAGE
.3 °..
`Relocate com.busti.ble storage to provide'at least 3. feet clearance around motor fuse box /fire door, (CFC
605.3) .
4
Relocate fire extin;guisher(s) so. that they will be in a'. conspicuous location, hanging on brackets with the..
top to the extinguisher not more than. 5 feet above the floor. (CFC 906. 0.5 &`906:9)
EXTINGUISHERS
5
Provide and install (amount) _____approved (type & size) :_ - ------ - portable fire
extinguisher to be immediately accessible for use in (area) ---------------------- ____ __ (CFC
TABLE 906.3)
6'.
Re- charge all fire extinguishers. Fire extinguishers shall be seryiced.at least once each year, and /or
after each use,.. by a: person having a valid license or certificate. (CFC 906 :2)
Provide and maintain "EXIT" sign(s) With , :Letters: 6 or more inches in height over.each required exit
SIGNS
..(door/window) to fire escape. (CFC 1011).
g
Provide and maintain appropriate numbers. on 'a contrasting 'ba,ckground and visible from the street to
indicate the correct address.of the building, (:CFC 505.1)
9
Repair all (cracks /holes /openings) in plaster in (location) _ _ ------------ _____
FIRIEDOORS,/
Plastering shall return the surface to its original fire resistive condition. (CFC 703.1)
FIRE SEPARATIONS
i0
R e m o.v a /repair (item & I o ca d o n) - - - - - -- ----------- - - - - -- ------ - - - - =- -----=--- - - = - --
Self- closing doors shall be designed to close by gravity,. or by the action of a mechanical device, or by an
approved smoke and heat sensitive device. Self-closing doors shall have no! attachments capable 'of
preventing the operation of the. closing device:: (CFC 703.2)
i1
Remove ail obstruction from hallways. Maintain all, means of egress free of•any storage. (CFC 1031.1)
EXITS'
12.
Provide.a contrasting colored and permanently` installed electric light over or near requirEA exit .
(location) `_ - -_ ___ ________ ____ to clearly indicate it as. an exit. (CFC :1008)'
Remove all storage. and /or other obstructions from fire escape landings and stairways, stair shafts., (Fire
STORAGE
13
escapes /stair shafts are to be maintained free from obstructions a,t;all times.) (CF.0 1003.6)
14
Extension cords shall not be used in lieu of permanent approved wiring. InstaII additional approved
ELECTRICAL APPLIANCES '.
e.lectrical outlets where needed. (CFC 605.5)
15 : .
Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) .(CFC
605.4) -
OUTDOOR BURNING
16
Recreational fires or open burning- CFC 307.1
FIREWORKS
17
Violations of Section (CF.C, 5608.1) & 8.44.040.(,B.M.C.) .
OTHER
18
CORRECTION DATE
Correct the violations noted ab a;e by: r
'
" ""'° —�`.'' � .r
CUSTOMER:
LEGEND:
C.F.C. CALIFORNIA FIRE CODE
" �(Si nal:u "re) .0(0lease`Pnnf Name -Lego ( Title)
C,B,C, CALIFORNIA BUILDING CODE
1
BAKERSFIELD.MUNICIPAL CODE
' - NO.: r7 . _
N.F.P :A. NATIONAL FIRE PROTECTION
INSPECTOR: ,! /,
ASSOCIATION
N.E.C. NATIONAL ELECTRIC CODE
White - Customer /Original Yellow - Station Copy Pink - Prevention Services