HomeMy WebLinkAboutFIRE SAFETY INSPECTION 2.7.19FACILITY ADDRESS DATE
FEE
FACILITYNAME p CT f TATE, Z7e .
BUSINESS OWNER'S NAME AND ADDRESS MANAGER'S NAME..
PH'NO.
BILL TO: "(IF DIFFERENT FROM ABOVE) NAME, ADDRESS CITY, STATE, ZIP
PH NO.
OCC TYPE
OCC LOAD
NO. OF FLOORS! OCC USE,.
n. A
RISER DATE
Wet /Dry Sprinkler' System •
Type of Alarm System .,
_644
q: CONSTRUCTION TYPE }"� HIGH RISE BLDG,
SQ /FT OF.BLD
YES NO
CORRECT ALL VIOLATIONS VIOLATION
_ REQUIREMENTS '
CHECKED BELOW NO.
1
Remove and safely dispose, of all hazardous refuse and dry vegetation 'on the above premises (CFC
COMBUSTIBLE WASTE / DRY
3 0 4, L . 1)
304.11.1),
VEGETATION
2 `"
Provide .non - combustible, containers with tight fitting, lids for the storage of combustible waste and
rubbish pending.,its safe disposal. (CFC 304.3. .2) .Note: applies to containers over 40 gallons.
COMBUSTIBLE sroRAGE
3 "
Relocate combustible storage to provide at least .3 feet clearance around motor.fuse bo;x /fire door (CFC -`
605.3)
4
" Relocate fire"extinguisher(s) so that they.will'.be in; a'co;nspicuous location, hanging on brackets with the-
top to the extinguisher not more than 5:feet above the floor. '(CFC 90.6.5 & 90.6.9)
EXTINGUISHERS
5
Provide. and install (amount) ____— approved (type & size) - __ ______ __- portable fire
extinguisher to be immediately accessible for use in (area) ___ ______________ _____ __ (CFC
TABLE 906.3)
6 ~:
Re- charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and /or
after each use, by a person having_ a. valid license or certifica e. 6.727 "°"' '
7 '
Provide and maintain "EX:IT" si"gn(s),with letters 6 or more inches, in height over each required exit
SIGNS
(do „'or /window) to fire escape.: (CFC 1011)
8
Provide and maintain appropriate numbers on a "contrasting background anal ,visible "from the street to
indicate the correct address of the 'building. (CFC 505.1)
9
Repair all (cracks /holesJopenings) in plaster in.(location) _- N ------ __________
FIRE DOORS
Plastering shall return the surface to its original fire, resistive condition. (CFC 703, .1)” '
FIRE SEPARATIONS
io `.
Remove /repair (item & I o ca t i o n) ------------------------------------------------------
Self- closing doors shall be designed to close by" gravity, or by the action of a mechanical device, or by an
approved smoke and heat sensitive device. Self - closing d;o,ors shall have no attachments capable of
preventing :the operation of the closing device. (CFC ' 703.2) .
11
Remove all obstruction-from hallways. Maintain all means `of'egress free of any storage. (CFC 10.31.1)'"
EXITS
Provide `a contrasting colored and permanently installed electric light over or' near required 'exit
A2.
(location) ------------- to clearly indicate it as an exit. (CFC 1008)
sTORAGE,
1,
Remove 'all. storage and /or other obstructions from fire escape.landin'gs and: stairways stair shafts. (Fire
escapes /stair shafts are to be maintained free from obstructions at all times.) (CFC 1003.6)
14
Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved
ELECTRICAL APPLIANCES
electrical outlets where needed. (CFC 605..5)
15.
Remove multiple attachment cords from specifi,c'electrical convenience outlet (o•ne plug per outlet) (CFC
605.4)
OUTDOOR BURNING
161 1.
Recreational fires or open burning. CFC 307.1
FIREWORKS
17
Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.).
OTHER
18
�+^
C�i I`: t' �%./c. .. Y CSG;C,. {hJi 0+. ("`a (� tJ a4 0 ' L ��+� i^4
�ry ,� j
V � J _t 0.4
11 f..`� -+ l2 <e— 1..��C.4 i=ce► ' -1 { t)f�. U f f�.
.°"'gin
j� , r -• £3-d t C7 C (X AJ4 i'r^ t) 5C, It, O pv.tu
CORRECTION DATE
Correct the.vio.l,ations noted above:by:
�f
CUSTOMER: " • i4 10 '
LEGEND:.
C.F.C. ' CALIFORNIA FIRE CODE
(Signa ure) (Ple ase Print N m Legibly, Title)
C B.C.." CALIFORNIA BUILDING CODE -
B M.C. BAKERSFIELD MUNICIPAL CODE
INSPECTOR: _ N.Q. ;
N.F.P.A. NATIONAL FIRE PROTECTION
ASSOC iArION
N.E.C., NATIONAL ELECTRIC, CODE
White — Customer /Original Yellow - Station Copy in - Prevention Services l ¢
FD 2022 (Rev. 10/2017)