HomeMy WebLinkAbout1520 20th st. inspector report 1-7-14_2019032108014201Facility Name: Date of Inspection: AT&T Corp. CAK010 Time In: ; Op Ao" Time Out: Address: Inspected by: Ernie Medina 1520 20th Street. Bakersfield, CA 93301 II Contact: M I- r, _ i1 , 0 ICC# 8012428 -UI Type of Inspection: 5ffAnnual Compliance ❑Re- inspection ❑ Complaint =Tank Monitoring:., DW Suction: Continuous Interstitial at UDC and Tank Sump. DW: Continuous Interstitial Monitoring El El D El Brine/Hydrostatic ❑ Vacuum /Pressure. ❑�❑ DW VPH Monitoring: Includes lines, sumps, fill pipe, vapor lines, etc. ❑ ❑ ❑ ❑ ❑ SW: SIR and Line Test every 2 years. ❑ .. , ❑ ❑ ❑ �❑ SW: ATGr 0.1 annual. SW Pressurized: Line 0.1 gph annual or 0.2 gph monthly line test and LLD with Auto - Shutdown. E ❑.❑ ❑ ❑ ❑ ❑;� �_ SW: ATG 0.2 monthly. ❑ E ❑ ❑ . ❑ ❑ ; SW: Continuous In -Tank Leak Detection (CITLD). ❑ ❑ ❑ E] ❑;''❑ =_ SW: Tank Gauging. ❑ ❑ . . ,'; ❑ ❑' SW: Vadose /GW Monitoring. ❑ ❑ .- ❑ ❑ , Other Description: ❑❑ ❑�❑ Piping;Monitoring: DW Suction: Continuous Interstitial at UDC and Tank Sump. DW Pressurized: Interstitial at UDC and Turbine Sump and 3.0 gph LLD, ❑ Annual Line Test or ❑ Auto - shutdown and Failsafe. 1 1❑ ❑ ❑�❑ DW VPH Monitoring: Includes lines, sumps, fill pipe, vapor lines, etc. ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ .. , SW Conventional Suction: Triennial 0.1 gph line test., and daily monitoring. ❑ ❑ � ❑ ❑ = - SW Pressurized: Line 0.1 gph annual or 0.2 gph monthly line test and LLD with Auto - Shutdown. E El ❑ ❑ ❑ ❑�`� SW or DW Safe Suction. ❑ ❑ E E] E E] SW: Vadose Zone or GW Monitoring. ❑ ❑ ❑ ❑ ❑ ❑ � �❑ DW SW G 't FI P' U1 avl y ow Ipe. . Other Description: ❑ - ❑ " ❑ ❑ ReferPnces to the Health and Safety Code. the California Code of Reaulations and the Code of Federal Regulations throuqhout this Appendix are intended to be useful but are not necessarily exhaustive of all legal references that might apply or be relevant to a specific compliance determination. Laws and regulations are subject to change, so the references contained herein may not be up to date. It is the responsibility of the owner and operator to know and comply with all applicable legal requirements. UNDERGROUND STORAGE TANK COMPLIANCE INSPECTION REPORT Facility Name: Date: Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979 R" If in compliance, check the box. Check NA if not applicable. If a violation, determine if Minor, Class 11, or Class 1, or To Violations Be Determined (TBD) if uncertain and will be determined later. .. .. .e . .. :.� . ..:' -i, „^. .. >t :GI -WYE �.., s WS. ,. Ym„ '' {� Y�'k°c' 3 .r7'7'.. ,�., -?u {t,.r .<. .y �t S, .A. .� )' � S ,`"w`i .. x, 'h.'�Y'YY". f� ?'�',: �"... f z : .`?-' "J ^2✓.�u`5- io- -. ,.a'a 3=%'. F " : ,..,{ °r s r' a e. aa. s , a , e -� i�"E ,fy"C L G.: . . "f .'"f �',•vt �G: . ,y Y . x:s: Y, �.¢. ' f',` �i � �C��S ' +<l. r- :>�i,, ��_ rac � :�.: -. c+` ..:5 t{('.:' �. ,. 1i. 5•,, y� � 4+. f F t : � /q ?'V '4, �. , :6. §' Nv, � EY :. .:'�"i,3� fi. T. I , .✓�" i p},y '✓.5'a' � :� ,-��rM � �'. -. INN -: "�i,3r r�»y ".b`. 3t:wati. -...� 9?': � �, >I E :`F' f t �, - �< .,y. ,_Y�,' ■r�.. - .§�.ti✓�, -�'� ,'�,ia. f �`ft3�. �3, p ��` ( ih? 5 /� ff l�K''�l - �"'�,.. �✓ ✓...d :S°". .,y..` & � 3 .�: .'3 1, .. y.�i.. R --� 3'� -?'. l C✓1 � File Review 1 UST Permit to Operate is current. HSC 25284(a), 25299(a)(1) 25299 (b)(1) ❑ ❑ 2 Transfer of permit and /or change of information provided within 30 days of ownership /information changes. HSC 25284(b) (c); T23 CCR 2712(d) X3 UST form information current/correct for facility, including BOE ❑ number. HSC 25286(a) 59,4 Fees are paid up -to -date. HSC25285(c), 25287 ❑ )95 Monitoring Plan approved for current owner with appropriate ❑ content and level of detail. T23 CCR 2632(d), 2634 (d), 2641(h) A6 Current Emergency Response Plan submitted with appropriate ❑ content and level of detail. T23 CCR 2632(d), 2634 (d), 2641(h) ;K7 Plot Plan /Site Map submitted with appropriate content and ❑ level of detail. T23 CCR 2632(d), 2634(d), 2641(h), 2711(a)(8) ❑ 8 Owner /Operator agreement submitted, if required. HSC 25284(a)(3) 09 Certification of Compliance and Designated Operator i� ❑ -11r" S`c ^H a Certification submitted b current tank owner. T23 CCR 2715 CuQ/t &A.,�7 D. v ZZi2e X10 Certificate of Financial Responsibility submitted and is current S £�T• Csx�. ecy� for the permit period. HSC 25292.2, 25299.30- 25299.34; T23 CCR 2711; 2808.1; ❑ 2809-2809.2 X11 Monitoring system certification (most recent) conducted within allowable timeframe (sensors and console). Results submitted, ❑ and show all required components with passing results. Hsc 25284.1 a 4 c ; T23 CCR 2638 X12 Spill- bucket test results (most recent) conducted within allowable time frame. Results submitted and indicate a passing ❑ test. HSC 25284.2 ❑13 Leak Detector testing conducted within allowable time frame. The most recent annual certification submitted and shows RD RD RD RD J� passing results. 40 CFR 280.40(a)(2), 280.43(g)(1) &(2); 280.44(a); HSC 25292(e); T23 CCR 2638, 2641 ' )014 Secondary containment testing conducted within allowable time frame. Most recent testing results submitted and indicate ❑ a passing test. HSC 25284.1(a)(4)(8); T23 CCR 2637(a) 015 Pipe and /or tank integrity testing conducted within allowable time frame. Most recent testing results submitted and indicate passing results. 40 CFR 280.33, 280.40, 280.41, 280.44; T23 CCR 2636(1), 2643b3,c3,d e ❑16 Repaired tanks /piping are tightness tested within 30 days of RD RD RD RD X the rep air. 40 CFR 280.33; T23 CCR 2661 017 ELD test conducted within allowable time frame. Most recent test results submitted and passing results achieved. T23 CCR 2644.1 018 The corrosion protection system is checked by a corrosion specialist within six months of installation /repair and at least every three years thereafter; results show protection to be RP RP RP RP adequate. Impressed current inspected every 60- calendar days. 40 CFR 280.31, 280.70, T23 CCR 2635(a) (2) ❑19 Tank Lining recertification is current (within 10 years of lining and every 5 years thereafter) and compliant. 40 CFR280.21(b)(1)(#j; RP RP RP RP T23 CCR 2663(h) Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979 R" UNDERGROUND STORAGE TANK COMPLIANCE INSPECTION REPORT Facility Name: Date: Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979 Y . < C✓1 On Site Review This Inspection is being conducted during the annual monitoring certification. X YES ONO The service technician has provided ICC Certification and manufacturers training documentation, and possesses a tank tester's license or works under a CSLB contractor's license. IK YES O NO L i ., .T k.. :.. ,u. , a < _„r. ws ?" ,.::.. ;...,o .�,..... :.._..,,;.� .w .r., ...•. �#a. .+ni A p 4 i ... : m.. .. �... .s.'Hx+�u,.vsrl r ¢ ✓r.. ,. -. .. �' .. l,:-� ... .t" $, .. s" .. ,., -5 .: ,..$ ,:. Y � a 1. , .. ,..�. v.:.... .. t- General x,20 Tank systems meet current construction standards as required ❑ for type of system. HSC 25288 J621 Hazardous substance tanks have secondary containment. 40 RP RP RP RP ❑ CFR 280.42(b); T23 CCR 2631 X2 Electronic monitoring system has audible and visual alarm in ❑ operating condition. T23 CCR 2632, 2634, 2636 23 Monitor console programmed appropriately for monitoring ❑ option used. T23 CCR 2638, 2643, 2643.1 024 Tank systems in temporary closure meet requirements. 40 CFR RD RD RD RD 280.70; T23 CCR 2670 & 2671 025 Overfill Prevention mechanism present and operational according to type: ;&Flapper valve j5ZAud ible- visual alarm RP RP RP RP ❑ ❑ball float. ❑ A/V alarm and Ball Float 40 CFR 280.20(c)(1)pi), 280.21(d); T23 CCR 2635(b)(2), 2631 d 4 g:6 Spill prevention device is present and functional (in good condition and drain mechanism operational if applicable). 40 CFR RP RP RP RP ❑ 280.20 c 1 I , 280.21(d); T23 CCR 2635(b)(1);2665 027 Piping and piping penetration boots within sumps /UDC are in ❑ cR2�K /5? /ov. e'a PAP %N good condition. HSC25288(a), 25292.1 boa J.28 All sumps, spill buckets, and UDC's free from debris and liquid. ❑ HSC 25291(e), 25290.1, 25290.2, T23 CCR 2635(b) (1) (C) X29 Areas around vents appear to be free from signs of liquid ❑ releases. HSC 25288(a), 25290.1, 25290.2, 25295.5 R30 Release Detection methods are present and meet performance RD ❑ standards. See LG -113. 40 CFR 280.40(x)(3) RD RD RD ,31 All sensors are correct for the type of system and operational.. RD RD RD RD ❑ 40 CFR 280.40 a 2 , 280.43 1 & 2 ; HSC 25290.1 e , 25290.2, 25291; T23 CCR 2638 X32 All sensors are located in the proper position /location. 40 CFR 280.40(a)(2), 280.43(g)(1) &(2); HSC 25290.1, 25290.2, 25291; T23 CCR 2630(d); RD RD RD RD ❑ 2632(c);2641(a) ,6Z33 All secondary containment, including UDC shall be equipped with a continuous monitoring system that either activates an ❑ A/V alarm or stops the flow of product at the dispenser when it detects a leak. T23 CCR 2636 (0(1) Tank Monitoring X Y S :fix .: � a, >w.,f..i. � b� yxy{5� "v .. ). > y... .i) ,.:r ✓.:H, .,. >t _£.. f ) ,...._..� ) :,: .. r. -. .. u+�•.m'�:v�. y.,ili k� c', , AA l .r'k 6 3 4. ' � . �� uwv... �.n....��.+:,:IStN'.rt_i�+.. a' S d_ ,_ � .L'a. y� . 1+ .��..i -,, ., ... 4� 1 � Interstitial monitoring conducted properly. 40 CFR 280.40(x)(2), . )..c> , ... 1,. :.,,. x'v" .0 JZ34 RD RD RD RD El 280.43(g)(1)&(2); T23 CCR 2632 (c)(2); 2634 d 1 035 ❑ VPH monitoring conducted proper) HSC 25290 1 RD RD RD RD J9 ✓+sa- 4:.wuessL'�iaF ..... t .n . 5m, Dui# R' e�. v'{" �... �. e�,_,.y��v?.Y�nt�.�3<sYG.�e.... .,. : " >/'t .r^:..�w�.4....%a.. . u4° i�.,. u�'. �/ �+.. n, u,» e§._.,.J r... f£ .,..z,&:.X.i,+.:.- :f „:..ks. -... ... .0 .w:'., ,. <.._:..::,_1 _ ✓R s:r .t <, . . . _ ..i',..'S F' 1036 O SIR SIR and Biennial 0.1 gph tank test performed properly. 40 CFR RD RD RD RD 280.41, 280.43, T23 CCR 2643, 2646.1 037 Non - passing SIR monitoring report results are reported and RD RD RD RD investigated properly. 40 CFR 280.41(a), 280.43(h)(1),(2); T23 CCR 2646.1 Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979 UNDERGROUND STORAGE TANK COMPLIANCE INSPECTION REPORT Facility Name: Date: Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979 , u r, < ff a Ai r -r r r - SE. FRIM r O Automatic Tank Gauging (ATG) / Continuous In -Tank Leak Detection CITLD 038 ATG or CITLD 0.2 gph monthly test performed properly. 40 CFR RD RD RD RDl 280.43; T23 CCR 2643(b)(1), 2643 b 5 JW39 ATG generates a hard copy printout of all data reported including time and date, tank I.D., fuel depth, water depth, temperature, liquid volume and duration of test. If installed after ❑ 1/1/95 printout includes calculated leak rate and leak threshold. T23 CCR 2643 b 1 O Manual Tank Gauging (SW tanks </ =1000 gall. ONLY) 040 Weekly manual tank gauging performed properly. 40 CFR 280.43, RD RD RD RD �8( T23 CCR 2645 041 Tank Integrity test performed, if necessary. 40 CFR 280.43, T23 CCR RD RD RD RD ' 2645 O Vadose Zone and /or Groundwater Monitoring 042 Monitoring system is installed and monitored properly. 40 CFR RD RD RD RDI 280.43, T23 CCR 2647 -48 OTank Exemption 043 Tanks /piping meet tank exemption criteria, and weekly visual monitoring records are kept up-do-date. HSC 25283.5 Pi eMonitorin" F' z s`Q➢xk.. 3 v rnth aFh r a c .. & , 3 C'. N.. R ..:a, a,,.. . : .- ,a.._..ri; ,_..:......_..,,r, . w,,. �P ,..,,u .. ._:. ;n+.. ✓„ �s t. �,...r.3,.., .. ..,:_w „r..,z ,,.. �. _.,._.,. .._._ ,..,. .s .., ,. ,..:: », .. ,_._..0 :.._•...e.._s..:.. O Continuous Monitoring System ;944 DW piping (gravity, suction, pressure) in the turbine sump has continuous monitoring system that activates an audible and RD RD RD RD ❑ visual alarm or restricts or stops flow at dispenser. T23 CCR 2636 (0(1) J45 DW piping in the is continuously monitored and method s've1.04 either shuts down the flow of product to the dispenser or ❑ activates an AN alarm. T23 CCR 2636(0(1) O Line Integrity Testing for Pressurized Piping 046 An annual 0.1 gph line integrity test is performed properly. (Either third party or by Enhanced Line Leak Detection) T23 CCR RD RD RD RD 2636 (0(4) ❑47 In lieu of the annual tightness test for DW pressurized piping, the monitoring system for all product piping outside the dispenser is fail -safe and shuts down the pump when a leak is RD RD RD RD detected and the monitoring system shuts down the pump or flow restriction occurs when a leak is detected in the UDC. T23 CCR 26360(5) O Line Leak Detectors (LLD) 048 LLD's installed, annually tested, and operational on DW pressurized piping that detects a 3.0 -gph leak, and restricts or RD RD RD RDI shuts off flow of product. T23 CCR 26360(2) O DW Emergency Generator Tank ❑49 LLD activates AN alarm and monitoring system is checked RD RD RD RD daily. T23 CCR 26360(2) *0 In lieu of LLD, continuous monitoring system of DW emergency 2 y h2 generator tank activates AN alarm, system is checked daily, ❑ and logs are kept. T23 CCR 2636 0(6) ..a..w: r. >a.:K.. nv _.. u ... Y ,.. ... t✓ ry ,.. C t.,,... . ;_ ,... .. k 5.:, .,.. ':Yi. .. F >....:, 4C - ... ...,, .., Y ,. ... ,'; . '.4;:.. •. .. :. F.. ..,.. O Line Integrity Testing 051 SW pressurized piping: annual 0.1 gph line integrity test or a monthly 0.2 gph line integrity test is performed properly. 40 CFR RD RD RD RD 280.41, 280.44; T23 CCR 2643 c 2 , 3 052 SW conventional suction system: 0.1 gph line integrity test is RD RD RD I i RD performed every three years. 40 CFR 280.40, 280.41; T23 CCR 2643(d) Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979 UNDERGROUND STORAGE TANK COMPLIANCE INSPECTION REPORT Facility Name: Date: 053 SW conventional suction system: inspections conducted for presence of air in the pipeline. Daily monitoring records are kept. T23 CCR 2643(d) 054 SW gravity flow piping: biennial 0.1 gph integrity test or overfill tank integrity test is conducted within allowable time frames. T23 CCR 2643(e) O Safe Suction (SS) System 055 Piping meets the SS requirements. 40 CFR 280.41; T23 CCR 2636(a)(3) RD RD RD RD O LLD for Pressurized Piping 056 LLD's installed, annually tested and operational on SW pressurized piping. Pump shuts down when a leak occurs and when the LLD fails or is disconnected. T23 CCR 2666 ❑57 LLD's installed, annually tested, and operational on SW emergency generator systems; LLD is connected to an AN alarm. 40 CFR 280.40(a)(2), 280.43(g)(1),(2), 280.44(a); T23 CCR 2666 Corros�dn Pro ection ; 058 Metal Tanks and piping components have corrosion protection, or are isolated from the backfill. 40 CFR 280.20, 280.21 059 Corrosion protection equipment turned on, functioning properly and provides continuous protection. 40 CFR 280.31(a), (b)(1); T23 CCR 2635 060 Cathodic protection system is tested within 6 months of installation and then every 3 years. 40 CFR 280.31(a) & (b) (1); T23 CCR 2635 a 2 061 Impressed current systems checked every 60- calendar days and records are up-to-date. 40 CFR 280.31(c); T23 CCR 2635(x)(2) 064 to Pa erwork X62 Permit and conditions available on -site. Facility is operated according to permit and conditions. HSC 25293, 25299; T23 CCR 2712(1) X63 Monitoring and response plans are on -site and are the approved version. T23 CCR 2712(1); 2632 ;2634; 2641 5464 Site plan depicts current site conditions and has all required elements. T23 CCR 2632(d) ;965 All release detection records for monitoring method are available, up -to -date, and appropriate for leak detection method. 40 CFR 280.41, 280.45 066 All monitoring /testing records /documents are available for the required timeframe. (3 years, 6'/2 years, five years, life of tank) T23 CCR 2712 67 Equipment maintenance records/logs available. T23 CCR 2712(b) 068 Alarm logs /tapes available and appropriate follow -up actions occurred. T23 CCR 2712(b); 2632; 2634 X69 Visual observation logs available, up -to -date, and appropriate follow-up actions to problems occurred. T23 CCR 2712(b); 2642 JWO Designated UST Operator monthly reports available and com lete. T23 CCR 2715 01 Employee training records available and training appropriate and u -to -date. T23 CCR 2715 t72 Suspected or actual unauthorized releases are recorded and /or reported within allowed timeframes, including non - passing test results. Leak and Spill Logs available. 40 CFR 280.50, T23 CCR, 2650, 2652 'PV3 Financial Responsibility Certificate and mechanisms (CFO Letter, etc.) on -site and up -to -date. HSC 25292.2, 25299.30- 25299.34; T23 CCR 2711; T23 2808.1; 2809 - 2809.2 mmm© RP I RP I RP 1 RP RP 1 RP 1 RP I RP RP I RP I RP 1 RP RD 1 RD I RD I RD RD I RD I RD 1 RD Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979 UNDERGROUND STORAGE TANK COMPLIANCE INSPECTION REPORT Facility Name: Date: SOC AND RED TAG In : 6 \iF ��" ,. a. This facility is in compliance with Release Detection (RD) requirements only. (No violations in boxes marked RD, but one or more in boxes marked RP.) ❑ b. This facility is in compliance with Release Prevention (RP) requirements only. (No violations in boxes marked RP, but one or more in boxes marked RD.) ❑ c. This facility is in compliance with BOTH Release Detection (RD) and Release Prevention (RP) requirements. (No violations in boxes marked RD or RP.) d. This facility is NOT in compliance with both Release Detection (RD) and Release Prevention (RP) requirements. (One or more violations marked in (both) boxes RD ❑ and RP.) yM'F� t t Y � � �.x r�` A Red Tag was issued to this facility based on the results of this inspection. Red Tag # ❑ Reason for Red Tag (Choose one): 1. Violation that causes or threatens to cause a liquid release. CCR 2717(x)(1) ❑ 2. Violation that impairs the ability of an UST system to detect a leak. CCR 2717(x)(2) ❑ 3. Chronic violation or committed by a recalcitrant violator. CCR 2717(x)(3) ❑ Item inspection Comments: Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979