HomeMy WebLinkAbout3200 panama inspector report 9-10-13Facility Name:
#3351 Howard's Mini Mart
Address:
3200 Panama Ln. Bakersfield, CA. 93313
Contact:
R. Craig Lincoln
Phone:
; BAKERSFIELD FIRE DEPARTMENT
`. Prevention Services Division
B a R s a "' - 2101 H Street
_*FIRE Bakersfield, CA 93301
AAbM..1dft1
ARYN' f Phone: 661-326-3979-
Date of Inspection:
Time In: (�,� I Time Out:
Inspected by Esther Duran
ICC# 5296325 -UI
Type of Inspection:
Annual Compliance ❑Re- inspection ❑ Complaint
Permission for Inspection Granted by:
(661) 633-7555
Tank ID
#1
#2 .
#3
4,_
Size
12,000
'12 000
12,000
121 000
Contents
PREM
REG
DSL
REGIZ
Construction
SW CID
$W' S CP
SW CP
SW C P ,
Tank Monitoring
,
DW: Continuous Interstitial Monitoring
❑
❑
❑
❑`�
)ry ❑ Brine/Hydrostatic ❑ Vacuum /Pressure.
❑
❑
❑
SW: SIR and Line Test every 2 years.
El
❑
El
El
SW: ATG 0.1 annual.
SW: ATG 0.2 monthly.
❑
❑
❑
❑
SW: Continuous In -Tank Leak Detection (CITLD).
SW: Tank Gauging.
❑
❑
❑
❑
❑
❑
SW: Vadose/GW Monitoring.
❑
0
❑
❑
Other Description:
PipingrMonitoring:
❑
❑
❑
❑
DW Suction: Continuous Interstitial at UDC and Tank Sump.
DW Pressurized: Interstitial at UDC and Turbine Sump and 3.0 gph LLD,
❑ Annual Line Test or uto- shutdown and Failsafe.
DW VPH Monitoring: Includes lines, sumps, fill pipe, vapor lines, etc.
El
El :
El
❑
SW Conventional Suction: Triennial 0.1 gph line test., and daily
❑
El
[]
Q
monitoring.
SW Pressurized: Line 0.1 gph annual or 0.2 gph monthly line test and
❑
El
❑
❑
LLD with Auto - Shutdown.
El
F-1
❑
SW or DW Safe Suction.
❑
❑.
❑
❑
SW: Vadose Zone or GW Monitoring.
❑
❑
❑
DW or SW: Gravity Flow Pipe.
El
❑❑
❑
❑
Other Description:
References to the Health and Safety Code, the California Code of Regulations and the Code of Federal Regulations throughout this Appendix are
but not necessarily exhaustive of all legal references that might apply or be relevant to a specific compliance determination.
intended to be useful are
Laws and regulations are subject to change, so the references contained herein may not be up to date.
It is the responsibility of the owner and operator
to know and comply with all applicable legal requirements.
UNDERGROUND STORAGE TANK COMPLIANCE INSPECTION REPORT
Facility Name: Date:
Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979
If in compliance, check the box. Check NA if not applicable.
If a violation, determine if Minor, Class II, or Class I, or To
Violations
Be Determined (TBD) if uncertain and will be determined
later.
n
w -,
r
g
3 , Ya
.
vA.r+ .
L-�
n
zC �^✓
ate •:
.. v - „, k.,. y., .', .r r' .- ...... w, 4*,.., -�.-
... _
'... a
wt�
..�
. -��`'
:'
Fi1e :Review
C�1
❑ 1
UST Permit to Operate is current. HSC 25284(x), 25299(x)(1) 25299 (b)(1)
❑
❑ 2
Transfer of permit and /or change of information provided within
30 days of ownership /information changes. HSC 25284(b) (c); T23
CCR 2712(d)
I3
UST form information current/correct for facility, including BOE
❑
number. HSC 25286(x)
4
Fees are paid up -to -date. HSC 25285(c), 25287
❑
3K5
Monitoring Plan approved for current owner with appropriate
❑
content and level of detail. T23 CCR 2632(d), 2634 (d), 2641(h)
;96
Current Emergency Response Plan submitted with appropriate
❑
content and level of detail. T23 CCR 2632(d), 2634 (d), 2641(h)
197
Plot Plan /Site Map submitted with appropriate content and
❑
level of detail. T23 CCR 2632(d), 2634(d), 2641(h), 2711(a)(8)
8
Owner /Operator agreement submitted, if required. HSC 25284(a)(3)
❑
9
Certification of Compliance and Designated Operator
❑
Certification submitted by current tank owner. T23 CCR 2715
10
Certificate of Financial Responsibility submitted and is current
for the permit period. HSC 25292.2, 25299.30 - 25299.34; T23 CCR 2711; 2808.1;
❑
2809 - 2809.2
11
Monitoring system certification (most recent) conducted within
allowable timeframe (sensors and console). Results submitted
❑
and show all required components with passing results. HSC
25284.1 a 4 c ; T23 CCR 2638
12
Spill- bucket test results (most recent) conducted within
allowable time frame. Results submitted and indicate a passing
❑
test. HSC 25284.2
J113
Leak Detector testing conducted within allowable time frame.
The most recent annual certification submitted and shows
RD
RD
RD
RD
❑
passing results. 40 CFR 280.40(a)(2), 280.43(g)(1) &(2), 280.44(a); HSC 25292(e);
T23 CCR 2638, 2641 '
1
11
)414-
Secondary containment testing conducted within allowable
time frame. Most recent testing results submitted and indicate
❑
a passing test. HSC 25284.1(a)(4)(B); T23 CCR 2637(x)
015
Pipe and /or tank integrity testing conducted within allowable
time frame. Most recent testing results submitted and indicate
passing results. 40 CFR 280.33, 280.40, 280.41, 280.44; T23 CCR 2636(0,
2643(b)(3), (c)(3), d e
016
Repaired tanks /piping are tightness tested within 30 days of
RD
RD
RD
RD
the repair. 40 CFR 280.33, T23 CCR 2661
017
ELD test conducted within allowable time frame. Most recent
❑
test results submitted and passing results achieved. T23 CCR
2644.1
X18
The corrosion protection system is checked by a corrosion
specialist within six months of installation /repair and at least
every three years thereafter; results show protection to be
RP
RP
RP
RP
❑
adequate. Impressed current inspected every 60- calendar
days. 40 CFR 280.31, 280.70, T23 CCR 2635(a)(2)
Tank Lining recertification is current (within 10 years of lining
/919
and every 5 years thereafter) and compliant. 40 CFR280.21(b)(1)(i,);
RP
RP
RP
RP
❑
T23 CCR 2663(h)
Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979
UNDERGROUND STORAGE TANK COMPLIANCE INSPECTION REPORT
Facility Name: Date:
Bill
O Automatic Tank Gauging (ATG) / Continuous In -Tank Leak
MEMO
Detection CITLD)
038
ATG or CITLD 0.2 gph monthly test performed properly. 40 CFR
280.43; T23 CCR 2643(b)(1), 2643(b)(5)
039
ATG generates a hard copy printout of all data reported
including time and date, tank I.D., fuel depth, water depth,
temperature, liquid volume and duration of test. If installed after
1/1/95 printout includes calculated leak rate and leak threshold.
T23 CCR 2643 b 1
O Manual Tank Gauging (SW tanks </ =1000 gal. ONLY)
❑40
Weekly manual tank gauging performed properly. 40 CFR 280.43,
T23 CCR 2645
041
Tank Integrity test performed, if necessary. 40 CFR 280.43; T23 CCR
2645
O Vadose Zone and/or Groundwater Monitoring
042
Monitoring system is installed and monitored properly. 40 CFR
280.43; T23 CCR 2647 -48
*Tank Exemption
043
Tanks /piping meet tank exemption criteria, and weekly visual
monitoring records are kept up -do -date. HsC 25283.5
'P,
�
,, } Y'V?'. •�. /..xY e� .yG 1 =".{4` �tln u` iy,`�., Ipc is ["3' I�RJ i, 'u"'{ y k Y v{ e"' i 21 F'.XV 'xl `1 s^Y'L k `;4
'i l'
e.... 1-.,
O Continuous Monitoring System.
044
DW piping (gravity, suction, pressure) in the turbine sump has
continuous monitoring system that activates an audible and
visual alarm or restricts or stops flow at dispenser. T23 CCR
2636 f 1
❑45
DW piping in the UDC is continuously monitored and method
either shuts down the flow of product to the dispenser or
activates an AN alarm. T23 CCR 26360(1)
O Line Integrity Testing for Pressurized Piping
046
An annual 0.1 gph line integrity test is performed properly.
(Either third party or by Enhanced Line Leak Detection) T23 CCR
2636 (4
047
In lieu of the annual tightness test for DW pressurized piping,
the monitoring system for all product piping outside the
dispenser is fail -safe and shuts down the pump when a leak is
detected and the monitoring system shuts down the pump or
flow restriction occurs when a leak is detected in the UDC. T23
CCR 26360(5)
O Line Leak Detectors (LLD)
048
LLD's installed, annually tested, and operational on DW
pressurized piping that detects a 3.0 -gph leak, and restricts or
m
shuts off flow of product. T23 CCR 26360(2)
O DW Emergency Generator Tank
049
LLD activates AN alarm and monitoring system is checked
daily. T23 CCR 26360(2)
❑50
In lieu of LLD, continuous monitoring system of DW emergency
generator tank activates AN alarm, system is checked daily,
and logs are kept. T23 CCR 2636 0(6)
ss
O,R+Y�I'I" 3 t3' Y✓ � a ,p r* ,,.•rte Y ' a z t "tF q 4 h
O Line Integrity Testing
❑51
SW pressurized piping: annual 0.1 gph line integrity test or a
monthly 0.2 gph line integrity test is performed properly. 40 CFR
280.41, 280.44; T23 CCR 2643(c)(2),(3)
052
SW conventional suction system: 0.1 gph line integrity test is
performed every three years. 40 CFR 280.40, 280.41; T23 CCR 2643(d)
Bill
MEMO
Neil
!III
Bill
m
onam
Nome
onno-
Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979
UNDERGROUND STORAGE TANK COMPLIANCE INSPECTION REPORT
FadiliV Name: Date:
Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979
❑53
SW conventional suction system: inspections conducted for
presence of air in the pipeline. Daily monitoring records are
ti
kept. T23 CCR 2643(d)
17154
SW gravity flow piping: biennial 0.1 gph integrity test or overfill
tank integrity test is conducted within allowable time frames.
T23 CCR 2643 e
O Safe Suction (SS) System
055
Piping meets the SS requirements. 40 CFR 280.41; T23 CCR 2636(a)(3)
RD
RD
RD
RD
(A -D
O LLD for Pressurized Piping
056
LLD's installed, annually tested and operational on SW
pressurized piping. Pump shuts down when a leak occurs and
RD
RD
RD
RD
when the LLD fails or is disconnected. T23 CCR 2666
057
LLD's installed, annually tested, and operational on SW
emergency generator systems; LLD is connected to an AN
alarm. 40 CFR 280.40(a)(2), 280.43(g)(1),(2), 280.44(a); T23 CCR 2666
Corrosion Protection
058
Metal Tanks and piping components have corrosion protection,
RP
RP
RP
RP
❑
or are isolated from the backfill. 40 CFR 280.20, 280.21
059
Corrosion protection equipment turned on, functioning properly
and provides continuous protection. 40 CFR 280.3 1 (a), (b) (1); T23 CCR
RP
RP
RP
RP
❑
2635
060
Cathodic protection system is tested within 6 months of
installation and then every 3 years. 40 CFR 280.31(a) & (b)(1); T23 CCR
RP
RP
RP
RP
❑
2635 a 2
❑61
Impressed current systems checked every 60- calendar days
RP
RP
RP
RP
❑
and records are up -to -date. 40 CFR 280.31(c); T23 CCR 2635(x)(2)
On -site Pa erwork
62
Permit and conditions available on -site. Facility is operated
❑
according t0 permit and conditions. HsC 25293, 25299, T23 CCR 2712(i)
1063
Monitoring and response plans are on -site and are the
❑
approved version. T23 CCR 2712(1); 2632 ;2634; 2641
4
Site plan depicts current site conditions and has all required
❑
elements. T23 CCR 2632(4)
X65
All release detection records for monitoring method are
available, up -to -date, and appropriate for leak detection
RD
RD
RD
RD
❑
method. 40 CFR 280.41, 280.45
66
All monitoring /testing records /documents are available for the
required timeframe. (3 years, 6'/ years, five years, life of tank) T23 CCR
❑
2712
l 7
Equipment maintenance records /logs available. T23 CCR 2712(b)
❑
` 68
Alarm logs /tapes available and appropriate follow -up actions
El
occurred. T23 CCR 2712(b); 2632; 2634
N'1_1
Visual observation logs available, up -to -date, and appropriate
❑
follow-up actions t0 problems occurred. T23 CCR 2712(b); 2642
r70
Designated UST Operator monthly reports available and
❑
complete. T23 CCR 2715
1171
Employee training records available and training appropriate
❑
.•'' -� �" -� ��
and up-to-date. T23 CCR 2715
` 072
Suspected or actual unauthorized releases are recorded
and /or reported within allowed timeframes, including non-
RD
RD
RD
RD
❑
passing test results. Leak and Spill Logs available. 40 CFR 280.50;
T23 CCR, 2650, 2652
73
Financial Responsibility Certificate and mechanisms (CFO
- ,� 1- 1�
Letter, etc.) on -site and up -to -date. HsC 25292.2, 25299.30- 25299.34; T23
❑
CCR 2711; T23 2808.1; 2809 - 2809.2
Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979
UNDERGROUND STORAGE TANK COMPLIANCE INSPECTION REPORT
Facility Name: Date:
774 Spill- bucket testing conducted appropriately and a passing test
achieved.
075 Secondary Containment testing conducted appropriately and a ❑
passing test achieved.
SOC AND RED TAG
Item
Inspection Comments:
a. This facility is in compliance with Release Detection (RD) requirements only. (No
,......• .,L4 ZA,.
violations in boxes marked RD, but one or more in boxes marked RP.)
b. This facility is in compliance with Release Prevention (RP) requirements only. (No
--r
D
violations in boxes marked RP, but one or more in boxes marked RD.)
c. This facility is in compliance with BOTH Release Detection (RD) and Release
Prevention (RP) requirements. (No violations in boxes marked RD or RP.)
d. This facility is NOT in compliance with both Release Detection (RD) and Release
Prevention (RP) requirements. (One or more violations marked in (both) boxes RD
and RP.)
A Red Tag was issued to this facility based on the results of this inspection.
El
Red Tag #
Reason for Red Tag (Choose one):
1. Violation that causes or threatens to cause a liquid release. CCR 2717(a)(1)
El
2. Violation that impairs the ability of an UST system to detect a leak. CCR 2717(a)(2)
El
3. Chronic violation or committed by a recalcitrant violator. CCR 2717(a)(3)
El
Item
Inspection Comments:
,......• .,L4 ZA,.
ULA le 61
--r
D
Bakersfield Fire Department — Prevention Services Division, 2101 H Street, Bakersfield, CA 93301 (661) 326 -3979