Loading...
HomeMy WebLinkAbout4800 fairfax 9-19-12Kern Business Forms (661) 325-5818 - KBF-7320 n BAKERSFIELD 1_ E ® .. YURI FIRE EVE TIO INSPECTION E y, 1 �r B' E -R S F I L D" L�� k � �} FIRE Prevention Services �E ®aRrM r 2101 H Street : _ �. Bakersfield ,1 CA 93301 DISTRICT BLOCK: NO. * DATE FEE; axFACILITY ADDRESS, c'4 CITY, STATE, ZIP NAME` 6: . +�,,s MANAGER'S NAME PH. NO. BUSINESS OWNER'S NAME AND ADDRESS- CITY, STATE, ZIP PH NO. BILL TO: (IF DIFFERENT FROM ABOVE) NAME, ADDRESS CITY, STATE, ZIP,'' PH NO., OCC TYPE OCC LOAD NO. OF FLOORS• HIGH RISE. BLDG RISER DATE YES 0' NO CORRECT ALL VIOLATIONS VIOLATION CHECKED BELOW NO. REQUIREMENTS 1: Remove and. safely di of all hazardous refuse and dry vegetation on the ab "ove premises (CFC COMBUSTIBLE WASTE / DRY' 304.1.1) - VEGETATION 2 Provide non -co `mbus`tible containers with tight fitting lids for the storage of. combustible waste and rubbish pending its safe disposal. (CFC 304.3. 1) STORAGE 3 Relocate combustible storage to provide at least 3 feet clearance- around motor fuse, box /fire door (CFC COMBUSTIBLE 605.3) -•4 Relocate fire extin 9 uisher(s) so that they will be in a conspicuous location, hanging on brackets with the 'top to the extinguisher not more'than 5 feet above the floor. (CFC 906.5 & 906:9) EXTINGUISHERS 5 Provide and. install (amount) __ approved (type & size), —_ —__ ___ __ _ portable -fire (CFC extinguisher to be fmme'diately accessible for use in (area) __________ _ _____ TABLE 906.3(1))' 6 Re- charge all fire extinguishers. Fire extinguishers shall. be serviced at least once each-ye "ar, and /or after each use', by a: person having a valid license or certificate. (CGR TITLE 19`: 575.1) Provide and maintain "EXIT" signs) with letters 5 or more inches in height' over each ,required exit SIGNS , (door/window) to .fire escape. (CFC 1011.5.1) 8 Provide and maintain appropriate numbers - on a contrasting background and visible from the street to ; . indicate the correct address of the build,i'ng. (Uit 505.1) 9 Repair all (cracks/ ho I es /openings), in plaster in (location),,---- ------ - ----- ----- ------ --- --- --- -• FIRE, DOORS Plastering shalt return the surface to its original fire resistive condition-. (.CFC 7.03.1) FIRE SEPARATIONS 10 Remove /repair ' (item & location) ---------=----------------------------------------------- Self7clo-sing doors shall be designed to close by gravity, or by the action of a mechanical device, or by an approved srnoke and heat sensitive device. Self- Closing doors shall have no attachments capable of preventing the operation of the closing •device. (CFC 703,2) 11 Remove alt obstruction from hallways. Maintain all means of egress free of any-storage.. (CFC 1028.3) EXITS 12 Provide a contrasting colored and permanently installed electric light over or near required exit (4ocation) __ =__ _ -_ to clearly, indicate it "as. an exit... (CFC 1006.3) STORAGE '13 Remove all storage and /or other obstructions from fire escape landings and stairways stair shafts. (Fire escapes /stair shafts are to be maintained free from obstructions at all times.) (CFC 102:8.3) 14 Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved ELECTRICAL APPLIANCES electrical outlets'where7'needed'. (CFC 605.5) X 15 Remove multiple attachment cords from specific electrical, convenience outlet (one plug.per outlet) (CFC 605.4) OUTDOOR BURNING 16 Recreational- fires or open burning. CFC 307.1 FIREWORKS 17 Vio).ations of °Section (CFC 3308.1) & 8.44.040 (13 :.t4.C.). 18 .. )� Cam; J" 4 �'' 0 OTHER' '- r 4 —w iJ y y�y �° '�' �, �' �^ , Y °� ,{� yam' i.Yt w '*^ CUSTOMER: " !J � '1v7 LEGEND: 3eF.C., CALIFORNIA FIRE CODE `(Sigh ature) ZPlease Print Name Legibly, Title) C B.C. CALIFORNIA BUILDING CODE ' B.M.C. BAKERSFIELD MUNICIPAL CODE N.F.P.A. NATIONAL FIRE PROTECTION " NO INSPECTOR: / ASSOCIATION (Signature) N.E.C. _ NATIONAL ELECTRIC CODE