CORRECT ALL VIOLATIONS VIOLATION REQUIREMENTS
CHECKED BELOW ivo
Remove and.safely dispose of all hazardous' refuse and dry vegetation on the above premises (CFC
COMBUSTIBLE WASTE / DRY 304.1.1)
VEGETATION
Provide non- combustible containers with `t'ightfitting lids for the storage of combustible waste and
rubbish pending its safe - disposal. (CFC' 304.3.2) Note:, applies to, containers over 40 gallons. '
COMBUSTIBLE STORAGE 3 :. Relocate combustible stora,ge',to provide at least 3'feet clearance ;aroun `m
d otor fuse box /fire door (CFC
605:.3)
4 Relocate fire extinguishers) o that they will be in a conspicuous location, hanging on brackets with the
top to the extingui'sher,,riot_ more , than 5 feet, above the floor. (CFC 906.5`& 906.9)
exrinicuiSHERS 5 Provide and install, (type "& sine)
------------------ portable fire
extinguisher to be .immediately accessible for use in (area) _- (CFC
TABLE • 906.3) '
6 Re- charge all fire extinguishers: Fire extinguishers shall be serviced: at least'o.nce each.year, and/or.
after each use, by ,a person having a, valid ,license or certificate. (CFC 906.:,2)
7. Provide "and maintain "EXIT" sign(s) with letters 6 or, rriore °inches in height'over; each required exit
SIGNS (door /win.dow) to fire escape. (CFC 1011)
8' Provide and 'maintain' appropriate numbers on a contrasting background and visible from the street to
indicate the correct address of the building. (CFC 505.1)
9 Repair
rinll slia I return. the surface in pls oteg.iin; (location) ____ ^______________ ____ ____ —____
FIRE DOORS/ ( g ) al fire., resistive condition. (CFC 703.1)
FIRE SEPARATIONS'
10 Remove /repair (item & location)
— =- ------=----- - - - - -- -- -------------- - - - - -- - - = - - --
g g se by gravity, or by the action of a mechanical device, or by an.
Self- closin doors shall be designed. to -clo
approved smoke and heat sensitive device. Self- clos;i,ng, doors sha,li have-no attachments: capable of
preventing the operation of the closing device. -'(CFC 703.2) '
1 "S Remove all obstruction from haliwa:ys: 'Maintain all means of egress free of any storage. _(CFC. 1031.1).
EXITS
12 Provide a, contrasting colored and permanently installed electric light over or near, required exit
(location) ___ ______ __ _____ __ __M_!: to clearly indicate it as `an exit. : (CFC `1008)' -
STORAGE 13` Remove all storage and/or other obstructions from fire „escape landings 'and stairways stair shafts. (Fire
escapes /stair shafts are to be maintained free. from obstructions at all times.) :(CFC 1003.6)
14 'Extension cords shall not be used in lieu of .permanent ap -proved wiring. Install additional approved
ELECTRICAL APPLIANCES electrical' outlets. where' needed. (CFC 605.5)
15: ` Remove multiple ,attachment cords''from specific electrical convenience outlet (one plug per outlet) (CFC
605.4)
OUTDOOR BURNING 16 Recreational 'fires or open burning. CFC 307`.1 1
FIREWORKS 17, Violations of Section (CFC 5608.1)' & 8.44.040
OTHER iPr7 -7/ r t T
{'. r
Correct the violations. noted 'above;by-,
°CORRECTION DATE ”
CUSTOMER: ,rte O�it.s�.:. Ir��r r-rtit LEGEND:'
C.F.C. CALIFORNIA FIRE CODE