HAZARDOUS WASTE REQUIREMENT
N/A
CERS
Violation #
'
COMMENTS ,
Recordkee in documentation
Generator has an EPA ID number [HSC 25143.131
3010002
Hazardous Waste determination made for all wastes
A Analysis . O Generator Knowledge ; [CCR 66262.401
3030005
C c ntingencY plan information posted near phone (CCR 66262.34(d)(2)]
3010022
Facilitypersonnel demonstrate training/awareness [CCR 66262.34(d)(2)]
3020001
Manifests/Consolidated Manifest receipts complete [CCR 66262.23(a)] `
3010008
- .-Blue co (s) of manifest mailed to DTSC [CCR 66262.23(a)(4)]
3010011
Bills of Ladin recei ts,available [CCR 66262.40(a)]
3010010
LDRs available and complete [CCR 66268.7(a)]
3030006
Onsite recycling reported using UPCF [HSC 25143.10]
3030001
Container /tank management
Containers are in good condition CCR 66262.34(d)(2)]
3030013
Containers are closed, exce t when adding/removing [CCR66262.34(d)(2)]
3030017
Satellite containers at or near point of generation [CCR 66262.34(e) (1) (A)]
Em containers are empty [CCR 66262.34(f)]
3030007
Containers inspected weekly' [CCR 66262.34(d)(2)]
3030019
Tanks inspected daily CCR 66262.34 d 2 L40CFR 265.201
3030027
h
One container per waste "stream at satellite area CCR 66262.34(d)(2)]
3030022
m
Exclude recyclable materials stored in accordance with local
ordinance/hazardousmateria1s codes [HSC 25143.10]
3010016
Accumulation Time Limits
Waste is accumulated not more than 90/180/270 CCR 66262.34 d
3030010
Em t °containers managed within one year CCR 66262.34(d)]
3030010
Universal waste accumulated less than one e
3030011a
Used oil filters offsite within 180 (1 year <1 ton) [CCR 66266.130(c)(4)}
3030004
Pb -acid batteries offsite within 180 (1 yr. < 1 ton) [CCR66266.81(a)(3)]
3030002. .
Labeling/Marking
Containers are properly labeled [66262.34(f)]
3030007
{
Excluded rec clable materials marked properly [HSC 25143.9(a)]
3050005
Universal waste container properly labeled (CCR 66273.341
3030008
Used oil filters marked "drained used oil filters" [CCR 66266.1301
3030004
Date written on s ent lead- acid'batteries - [CCR 66266.81(a)(6)(B)]
3030003
"Used Oil" marked on all used oil tanks /containers [CCR 66279.21
3030007"
Tank marked with "haz.waste" contents, start date 66262.34 (f)]
3030007
Treatment Transport and Disposal/Other
Have ermit/authorization to do treatment [HSC 25136.21
3040003
Waste sent with authorized transport (gen. eli ible) [CCR 66263.411
3050001
Waste disposed of to authorized point/ party [HSC 25189.5(a)]
3050002
Failed to ` properly ''handle appliance wastes HSC 25212 a
Fire Protection [66262.34(d)(2)]
3030032
Print and sign in this box for receipt of this report. Signature does not imply agreement with findings only receipt of report.
INSPECTOR...
POST INSPECTION INSTRUCTIONS:
• Correct the violation(s) noted above by
• Within 5 days of correcting all: of the violations, sign and return a copy of this page to:
Bakersfield Fire Dept., Prevention Services, 2101 H St. Bakersfield, CA 93301
White -- Business Copy Yellow- Station Copy