Loading...
HomeMy WebLinkAboutFMC 20182/21/07 1 MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of California Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. $General Information Facility Name: ________________________________________________________________________ Bldg. No.:___________________ Site Address: ________________________________________________ City: ________________________ Zip: ____________________ Facility Contact Person: ___________________________________________ Contact Phone No.: _________________________________ Make/Model of Monitoring System: ________________________________________ Date of Testing/Servicing: ___________________ %Inventory of Equipment Tested/CertifiedCheck the appropriate boxes to indicate specific equipment inspected/serviced: Tank ID: ____________________________________________ 2/21/072 D. Results of Testing/Servicing Software Version Installed: _____________________________________ Complete the following checklist: 2/21/073 F. In-Tank Gauging / SIR Equipment: Leak Detector Test Results Sheet &ĂĐŝůŝƚLJEĂŵĞ͗Site Address: Test Date: TechnicianŽŶĚƵĐƚŝŶŐdĞƐƚ: ICC No.: Product Type LLD Type Model Serial No. Check Valve Holding Pressure Bleed Off ML. Leak Rate Tested: Pass/Fail 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi 3 gph @ 10 psi TechnicianSignature: Date: 87 gasoline mechanical fx1v unreadable 13 psi 120 ml pass Diesel mechanical fx1dv unreadable 13 psi 110 ml pass 91 gasoline mechanical fx1v unreadable 13 psi 120 ml pass 09/10/2018 Jaco #5562 Fastrip #6 09/10/2018 1640 South Chester Ave Frank Amestoy 8374998 Fastrip chester setup Responses Received: 200 FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SEP 10, 2018 9:03 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNL 7172 64.07 0.0 85.5 4890 2 DIESEL 2286 27.27 0.0 89.0 9776 3 PNL 7271 64.80 0.9 88.9 4791 4 UNL 2 SIPHON 7289 64.92 0.8 85.9 4773 I90500 SEP 10, 2018 9:03 AM SOFTWARE REVISION LEVEL VERSION 329.01 SOFTWARE# 346329-100-B CREATED - 09.01.29.15.44 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I50500 SEP 10, 2018 9:03 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 SEP 10, 2018 9:03 AM SHIFT TIME 1 : DISABLED I50202 SEP 10, 2018 9:03 AM SHIFT TIME 2 : DISABLED I50203 SEP 10, 2018 9:03 AM SHIFT TIME 3 : DISABLED I50204 SEP 10, 2018 9:03 AM SHIFT TIME 4 : DISABLED I54600 SEP 10, 2018 9:03 AM TANK PER TST NEEDED WRN: DISABLED I54900 SEP 10, 2018 9:03 AM TANK ANN TST NEEDED WRN: DISABLED I55300 SEP 10, 2018 9:03 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 SEP 10, 2018 9:03 AM LINE PER TST NEEDED WRN: DISABLED I55900 SEP 10, 2018 9:03 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 SEP 10, 2018 9:03 AM PRINT TC VOLUMES ENABLED I50E00 SEP 10, 2018 9:03 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 SEP 10, 2018 9:03 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 SEP 10, 2018 9:03 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 SEP 10, 2018 9:03 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 SEP 10, 2018 9:03 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 SEP 10, 2018 9:03 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 SEP 10, 2018 9:03 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 SEP 10, 2018 9:03 AM TANK CHART SECURITY DISABLED I5BD00 SEP 10, 2018 9:03 AM CUSTOM ALARM LABELS DISABLED I56000 SEP 10, 2018 9:03 AM MASS/DENSITY DISABLED I88101 SEP 10, 2018 9:03 AM PORT SETTINGS: COMM BOARD : 1 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88102 SEP 10, 2018 9:03 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 SEP 10, 2018 9:03 AM PORT SETTINGS: COMM BOARD : 3 (EDIM ) RS-232 SECURITY CODE : DISABLED I88104 SEP 10, 2018 9:03 AM I88105 SEP 10, 2018 9:03 AM I88106 SEP 10, 2018 9:03 AM I52000 SEP 10, 2018 9:03 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE ??? 10, 2018 DISABLED 2 ON DATE ??? 10, 2018 DISABLED 3 ON DATE ??? 10, 2018 DISABLED 4 ON DATE ??? 10, 2018 DISABLED 5 ON DATE ??? 10, 2018 DISABLED 6 ON DATE ??? 10, 2018 DISABLED 7 ON DATE ??? 10, 2018 DISABLED 8 ON DATE ??? 10, 2018 DISABLED I60100 SEP 10, 2018 9:03 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL ON 2 DIESEL ON 3 PNL ON 4 UNL 2 SIPHON ON I60200 SEP 10, 2018 9:03 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL 2 DIESEL 3 PNL 4 UNL 2 SIPHON I60300 SEP 10, 2018 9:03 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL 1 2 DIESEL 2 3 PNL 3 4 UNL 2 SIPHON 4 I60900 SEP 10, 2018 9:03 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL 0.000700 2 DIESEL 0.000450 3 PNL 0.000700 4 UNL 2 SIPHON 0.000700 I60700 SEP 10, 2018 9:03 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL 111.50 2 DIESEL 111.50 3 PNL 111.50 4 UNL 2 SIPHON 111.50 I60A00 SEP 10, 2018 9:03 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNL 1 PT 12062 2 DIESEL 1 PT 12062 3 PNL 1 PT 12062 4 UNL 2 SIPHON 1 PT 12062 I60400 SEP 10, 2018 9:04 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 12062 2 DIESEL 12062 3 PNL 12062 4 UNL 2 SIPHON 12062 I60500 SEP 10, 2018 9:04 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 12062 0 0 0 2 DIESEL 12062 0 0 0 3 PNL 12062 0 0 0 4 UNL 2 SIPHON 12062 0 0 0 I60600 SEP 10, 2018 9:04 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 DIESEL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PNL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 UNL 2 SIPHON 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 SEP 10, 2018 9:04 AM TANK PRODUCT LABEL METER DATA 1 UNL NO 2 DIESEL NO 3 PNL NO 4 UNL 2 SIPHON NO I62F00 SEP 10, 2018 9:04 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNL 4.0 INCHES 2 DIESEL 4.0 INCHES 3 PNL 4.0 INCHES 4 UNL 2 SIPHON 4.0 INCHES I62700 SEP 10, 2018 9:04 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNL 2.0 2 DIESEL 2.0 3 PNL 2.0 4 UNL 2 SIPHON 2.0 9999FF1B I62400 SEP 10, 2018 9:04 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL 3.0 2 DIESEL 3.0 3 PNL 3.0 4 UNL 2 SIPHON 3.0 I62800 SEP 10, 2018 9:04 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 12062 2 DIESEL 12062 3 PNL 12062 4 UNL 2 SIPHON 12062 I62300 SEP 10, 2018 9:04 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 10855 2 DIESEL 10855 3 PNL 10855 4 UNL 2 SIPHON 10855 I62200 SEP 10, 2018 9:04 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 11459 2 DIESEL 11459 3 PNL 11459 4 UNL 2 SIPHON 11459 I62900 SEP 10, 2018 9:04 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1809 2 DIESEL 1809 3 PNL 1809 4 UNL 2 SIPHON 1809 I62100 SEP 10, 2018 9:04 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 500 2 DIESEL 500 3 PNL 500 4 UNL 2 SIPHON 500 I62600 SEP 10, 2018 9:04 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 99 2 DIESEL 99 3 PNL 99 4 UNL 2 SIPHON 99 I62500 SEP 10, 2018 9:04 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 99 2 DIESEL 99 3 PNL 99 4 UNL 2 SIPHON 99 I60800 SEP 10, 2018 9:04 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNL 4.50 2 DIESEL 2.50 3 PNL 4.30 4 UNL 2 SIPHON 4.44 I60B00 SEP 10, 2018 9:04 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 SEP 10, 2018 9:04 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNL 0.00 2 DIESEL 0.00 3 PNL 0.00 4 UNL 2 SIPHON 0.00 I61200 SEP 10, 2018 9:04 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL NONE NONE 2 DIESEL NONE NONE 3 PNL NONE NONE 4 UNL 2 SIPHON NONE NONE I63600 SEP 10, 2018 9:04 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1220 2 DIESEL 120 3 PNL 120 4 UNL 2 SIPHON 120 I62A00 SEP 10, 2018 9:04 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 0 2 DIESEL 0 3 PNL 0 4 UNL 2 SIPHON 120 I62C00 SEP 10, 2018 9:04 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNL STANDARD 2 DIESEL STANDARD 3 PNL STANDARD 4 UNL 2 SIPHON STANDARD I62D00 SEP 10, 2018 9:04 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 2 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 4 UNL 2 SIPHON GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 SEP 10, 2018 9:04 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNL OFF OFF 2 DIESEL OFF OFF 3 PNL OFF OFF 4 UNL 2 SIPHON OFF OFF I63000 SEP 10, 2018 9:04 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNL OFF 2 DIESEL OFF 3 PNL OFF 4 UNL 2 SIPHON OFF I63200 SEP 10, 2018 9:04 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNL OFF 2 DIESEL OFF 3 PNL OFF 4 UNL 2 SIPHON OFF I61000 SEP 10, 2018 9:04 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNL 1 2 DIESEL 1 3 PNL 1 4 UNL 2 SIPHON 1 I63A00 SEP 10, 2018 9:04 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNL 10.00% 2 DIESEL 10.00% 3 PNL 10.00% 4 UNL 2 SIPHON 10.00% I61100 SEP 10, 2018 9:04 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : TANK 1 MAR 19, 2009 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED TEST ON DATE : TANK 2 MAR 19, 2009 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED TEST ON DATE : TANK 3 MAR 19, 2009 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED TEST ON DATE : TANK 4 MAR 19, 2009 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 SEP 10, 2018 9:04 AM CSLD PROBABLITY OF DETECTION I61400 SEP 10, 2018 9:04 AM CSLD CLIMATE FACTOR I61600 SEP 10, 2018 9:04 AM TANK PRODUCT LABEL CAL UPDATE 1 UNL IMMEDIATE 2 DIESEL IMMEDIATE 3 PNL IMMEDIATE 4 UNL 2 SIPHON IMMEDIATE I61A00 SEP 10, 2018 9:04 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNL DISABLED 2 DIESEL DISABLED 3 PNL DISABLED 4 UNL 2 SIPHON DISABLED I61B00 SEP 10, 2018 9:04 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 SEP 10, 2018 9:04 AM CSLD REPORT ONLY I62B00 SEP 10, 2018 9:04 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNL ??? 0, 0 2 DIESEL ??? 0, 0 3 PNL ??? 0, 0 4 UNL 2 SIPHON ??? 0, 0 I63300 SEP 10, 2018 9:04 AM LEAK TEST REPORT FORMAT: NORMAL I63400 SEP 10, 2018 9:04 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 0 2 DIESEL 0 3 PNL 0 4 UNL 2 SIPHON 0 I63500 SEP 10, 2018 9:04 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 2 DIESEL 1 3 PNL 1 4 UNL 2 SIPHON 1 I63900 SEP 10, 2018 9:04 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNL END FACTOR: NONE 2 DIESEL END FACTOR: NONE 3 PNL END FACTOR: NONE 4 UNL 2 SIPHON END FACTOR: NONE I78000 SEP 10, 2018 9:04 AM I77700 SEP 10, 2018 9:04 AM I77800 SEP 10, 2018 9:04 AM I78C00 SEP 10, 2018 9:04 AM I78300 SEP 10, 2018 9:04 AM I78F00 SEP 10, 2018 9:04 AM I78700 SEP 10, 2018 9:04 AM I70200 SEP 10, 2018 9:04 AM LIQUID LABEL DEVICE LABEL 1 UNL 1 STP 2 UNL1 ANN 3 DIESEL STP 4 DIESEL ANN 5 PNL STP 6 PNL ANN 7 UNL2 SIPON STP 8 UNL2 ANN 9 DISP 1-2 10 DISP 3-4 11 DISP 5-6 12 DISP 7-8 13 TRAN NO. 14 TRAN SO. 15 16 I70300 SEP 10, 2018 9:04 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL 1 STP TRI-STATE (SINGLE FLOAT) 2 UNL1 ANN TRI-STATE (SINGLE FLOAT) 3 DIESEL STP TRI-STATE (SINGLE FLOAT) 4 DIESEL ANN TRI-STATE (SINGLE FLOAT) 5 PNL STP TRI-STATE (SINGLE FLOAT) 6 PNL ANN TRI-STATE (SINGLE FLOAT) 7 UNL2 SIPON STP TRI-STATE (SINGLE FLOAT) 8 UNL2 ANN TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 3-4 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 7-8 TRI-STATE (SINGLE FLOAT) 13 TRAN NO. TRI-STATE (SINGLE FLOAT) 14 TRAN SO. TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 SEP 10, 2018 9:04 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL 1 STP STP SUMP 2 UNL1 ANN ANNULAR SPACE 3 DIESEL STP STP SUMP 4 DIESEL ANN ANNULAR SPACE 5 PNL STP STP SUMP 6 PNL ANN ANNULAR SPACE 7 UNL2 SIPON STP STP SUMP 8 UNL2 ANN ANNULAR SPACE 9 DISP 1-2 DISPENSER PAN 10 DISP 3-4 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 7-8 DISPENSER PAN 13 TRAN NO. PIPING SUMP 14 TRAN SO. PIPING SUMP 15 OTHER SENSORS 16 OTHER SENSORS I74200 SEP 10, 2018 9:04 AM I74300 SEP 10, 2018 9:04 AM I74400 SEP 10, 2018 9:04 AM I74700 SEP 10, 2018 9:04 AM I74800 SEP 10, 2018 9:04 AM I74900 SEP 10, 2018 9:04 AM I7BC00 SEP 10, 2018 9:04 AM I80200 SEP 10, 2018 9:04 AM I80300 SEP 10, 2018 9:04 AM I80400 SEP 10, 2018 9:04 AM I80700 SEP 10, 2018 9:04 AM RELAY LABEL DEVICE LABEL 1 UNL 1 2 DIESEL 3 PNL 4 5 OVERFILL ALARM 6 7 8 I80900 SEP 10, 2018 9:04 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL 1 NORMALLY OPEN 2 DIESEL NORMALLY CLOSED 3 PNL NORMALLY OPEN 4 NORMALLY OPEN 5 OVERFILL ALARM NORMALLY OPEN 6 NORMALLY OPEN 7 NORMALLY OPEN 8 NORMALLY OPEN I80B00 SEP 10, 2018 9:04 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 1 2 DIESEL 2 3 PNL 3 4 NONE 5 OVERFILL ALARM NONE 6 NONE 7 NONE 8 NONE I80A00 SEP 10, 2018 9:04 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL 1 PUMP CONTROL OUTPUT 2 DIESEL STANDARD 3 PNL PUMP CONTROL OUTPUT 4 STANDARD 5 OVERFILL ALARM STANDARD 6 STANDARD 7 STANDARD 8 STANDARD I80C00 SEP 10, 2018 9:04 AM I80800 SEP 10, 2018 9:04 AM RELAY SETUP REPORT R 1:UNL 1 TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 7:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:DIESEL TYPE: STANDARD NORMALLY CLOSED TANK #: 2 LIQUID SENSOR ALMS L 3:FUEL ALARM L 9:FUEL ALARM L11:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L11:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 9:SHORT ALARM L11:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM R 3:PNL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 5:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 5:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 5:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 6: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 7: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 8: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 SEP 10, 2018 9:05 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 SEP 10, 2018 9:05 AM I72300 SEP 10, 2018 9:05 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 V.P.SENSOR DISP 3-4 VAPOR PRESSURE 02 F.M.DISP 1-2 AIR FLOW METER 03 F.M.DISP 3-4 AIR FLOW METER 04 F.M.DISP 5-6 AIR FLOW METER 05 F.M.DISP 7-8 AIR FLOW METER 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 SEP 10, 2018 9:05 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 SEP 10, 2018 9:05 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 SEP 10, 2018 9:05 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 VAPOR PROCESSOR TYPE NONE IV4700 SEP 10, 2018 9:05 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 SEP 10, 2018 9:05 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 ACCEPT HIGH ORVR: NO IV4A00 SEP 10, 2018 9:05 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 01 01 01 BLEND3 02 02 02 01 BLEND3 03 03 03 02 BLEND3 04 04 04 02 BLEND3 05 05 05 03 BLEND3 06 06 06 03 BLEND3 07 07 07 04 BLEND3 08 08 08 04 BLEND3 IV4B00 SEP 10, 2018 9:05 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 SEP 10, 2018 9:05 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 SEP 10, 2018 9:05 AM ISD VERSION: 01.02 Fastrip chester before alarm history Responses Received: I10200 SEP 10, 2018 9:01 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 508079 507779 2 4 PROBE / G.T. 161504 161605 3 INTERSTITIAL BD 202172 202532 4 INTERSTITIAL BD 202533 202605 5 UNUSED 4812041 4753724 6 UNUSED 4809760 4750665 7 UNUSED 4811310 4748139 8 UNUSED 4810181 4747806 9 STP SENSE BOARD 33224 33262 10 RELAY BOARD 14888 14902 11 RELAY BOARD 14955 15014 12 UNUSED 4813085 4754591 13 UNUSED 4809830 4750180 14 UNUSED 4811668 4747055 15 UNUSED 4807351 4745392 16 UNUSED 4811447 4751865 COMM 1 RS232 SERIAL BD 14932 14969 COMM 2 RS232 SERIAL BD 14977 15014 COMM 3 ELEC DISP INT. 101186 101355 COMM 4 UNUSED 4810118 4748518 COMM 5 UNUSED 4811956 4751000 COMM 6 UNUSED 4806399 4751998 I90200 SEP 10, 2018 9:01 AM SOFTWARE REVISION LEVEL VERSION 329.01 SOFTWARE# 346329-100-B CREATED - 09.01.29.15.44 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 SEP 10, 2018 9:01 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L14 PIPE TRAN SO. FUEL ALARM CLEAR 9-06-18 12:12PM L14 PIPE TRAN SO. FUEL ALARM ALARM 9-06-18 12:11PM L13 PIPE TRAN NO. FUEL ALARM CLEAR 9-06-18 12:08PM L13 PIPE TRAN NO. FUEL ALARM ALARM 9-06-18 12:06PM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 9-06-18 11:10AM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 9-06-18 11:08AM L 2 ANNULAR UNL1 ANN FUEL ALARM CLEAR 9-06-18 11:04AM L 6 ANNULAR PNL ANN FUEL ALARM CLEAR 9-06-18 11:03AM L 8 ANNULAR UNL2 ANN FUEL ALARM CLEAR 9-06-18 10:30AM L 8 ANNULAR UNL2 ANN FUEL ALARM ALARM 9-06-18 10:22AM L 2 ANNULAR UNL1 ANN FUEL ALARM ALARM 9-06-18 10:22AM L 6 ANNULAR PNL ANN FUEL ALARM ALARM 9-06-18 10:22AM L 8 ANNULAR UNL2 ANN SENSOR OUT ALARM CLEAR 9-06-18 10:17AM L 7 STP SUMP UNL2 SIPON STP SENSOR OUT ALARM CLEAR 9-06-18 10:17AM L 2 ANNULAR UNL1 ANN SENSOR OUT ALARM CLEAR 9-06-18 10:17AM L 6 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 9-06-18 10:17AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 9-06-18 10:17AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 9-06-18 10:17AM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 9-06-18 10:17AM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 9-06-18 10:17AM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 9-06-18 10:17AM L 5 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 9-06-18 10:17AM L14 PIPE TRAN SO. SENSOR OUT ALARM CLEAR 9-06-18 10:17AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 9-06-18 10:17AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 9-06-18 10:17AM L13 PIPE TRAN NO. SENSOR OUT ALARM CLEAR 9-06-18 10:17AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 9-06-18 10:17AM L 2 ANNULAR UNL1 ANN SENSOR OUT ALARM ALARM 9-06-18 10:17AM L 8 ANNULAR UNL2 ANN SENSOR OUT ALARM ALARM 9-06-18 10:17AM L 7 STP SUMP UNL2 SIPON STP SENSOR OUT ALARM ALARM 9-06-18 10:17AM L 6 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 9-06-18 10:17AM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM ALARM 9-06-18 10:17AM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 9-06-18 10:17AM L14 PIPE TRAN SO. SENSOR OUT ALARM ALARM 9-06-18 10:17AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 9-06-18 10:17AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 9-06-18 10:17AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 9-06-18 10:17AM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 9-06-18 10:17AM L 5 STP SUMP PNL STP SENSOR OUT ALARM ALARM 9-06-18 10:17AM L13 PIPE TRAN NO. SENSOR OUT ALARM ALARM 9-06-18 10:17AM L10 DISP PAN DISP 3-4 FUEL ALARM CLEAR 9-06-18 10:14AM L10 DISP PAN DISP 3-4 FUEL ALARM ALARM 9-06-18 10:14AM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 9-06-18 10:13AM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 9-06-18 10:12AM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 9-06-18 10:11AM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 9-06-18 10:11AM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 9-06-18 10:11AM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 9-06-18 10:10AM L10 DISP PAN DISP 3-4 FUEL ALARM CLEAR 9-06-18 10:08AM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 9-06-18 10:08AM I11200 SEP 10, 2018 9:01 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK DIESEL DELIVERY NEEDED CLEAR 9-06-18 9:17AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 9-06-18 9:16AM OTHER ISD GROSS PRES WARN CLEAR 9-05-18 10:00AM OTHER ISD GROSS PRES WARN ALARM 9-04-18 10:01AM SYSTEM PRINTER ERROR CLEAR 8-29-18 1:42AM SYSTEM PAPER OUT CLEAR 8-29-18 1:42AM SYSTEM PRINTER ERROR ALARM 8-29-18 1:42AM SYSTEM PAPER OUT ALARM 8-29-18 1:42AM SYSTEM PRINTER ERROR CLEAR 8-29-18 1:42AM SYSTEM PAPER OUT CLEAR 8-29-18 1:42AM SYSTEM PRINTER ERROR ALARM 8-29-18 1:42AM SYSTEM PAPER OUT ALARM 8-29-18 1:42AM SYSTEM PRINTER ERROR CLEAR 8-29-18 1:42AM SYSTEM PAPER OUT CLEAR 8-29-18 1:42AM SYSTEM PRINTER ERROR ALARM 8-29-18 1:42AM SYSTEM PAPER OUT ALARM 8-29-18 1:42AM SYSTEM PRINTER ERROR CLEAR 8-29-18 1:42AM SYSTEM PAPER OUT CLEAR 8-29-18 1:42AM SYSTEM PRINTER ERROR ALARM 8-29-18 12:05AM SYSTEM PAPER OUT ALARM 8-29-18 12:05AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 8-23-18 11:08PM T 2 TANK DIESEL DELIVERY NEEDED ALARM 8-22-18 10:58AM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN CLEAR 8-13-18 10:00AM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN ALARM 8-12-18 10:02AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 8-11-18 1:40PM T 2 TANK DIESEL DELIVERY NEEDED ALARM 8-10-18 1:47PM SYSTEM PRINTER ERROR CLEAR 8-03-18 10:56AM SYSTEM PRINTER ERROR ALARM 8-03-18 10:56AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 7-31-18 12:34AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 7-30-18 10:04AM OTHER ISD SENSOR OUT WARN CLEAR 7-30-18 9:36AM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN CLEAR 7-30-18 9:36AM OTHER ISD SENSOR OUT WARN ALARM 7-29-18 10:03AM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN ALARM 7-29-18 10:03AM SYSTEM PRINTER ERROR CLEAR 7-26-18 3:32PM SYSTEM PAPER OUT CLEAR 7-26-18 3:32PM SYSTEM PRINTER ERROR ALARM 7-26-18 3:32PM SYSTEM PAPER OUT ALARM 7-26-18 3:32PM SYSTEM PRINTER ERROR CLEAR 7-26-18 3:32PM SYSTEM PAPER OUT CLEAR 7-26-18 3:32PM SYSTEM PRINTER ERROR ALARM 7-26-18 3:29PM SYSTEM PAPER OUT ALARM 7-26-18 3:29PM OTHER ISD GROSS PRES WARN CLEAR 7-22-18 10:00AM h 7 OTHER FP7: BLEND3 GROSS COLLECT WARN CLEAR 7-16-18 10:00AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 7-16-18 10:00AM OTHER ISD GROSS PRES WARN ALARM 7-15-18 10:02AM h 7 OTHER FP7: BLEND3 GROSS COLLECT WARN ALARM 7-15-18 10:02AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 7-14-18 10:02AM OTHER ISD GROSS PRES WARN CLEAR 7-09-18 9:05AM SYSTEM PRINTER ERROR CLEAR 7-09-18 9:04AM I20600 SEP 10, 2018 9:01 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 TANK ALARM HISTORY TANK 1 UNL SETUP DATA WARNING JAN 29, 2009 8:13 AM OVERFILL ALARM SEP 6, 2018 9:53 AM AUG 2, 2018 9:59 PM JUL 5, 2018 2:51 PM SUDDEN LOSS ALARM SEP 6, 2018 9:15 AM AUG 29, 2018 12:34 AM JUL 4, 2018 7:01 AM PROBE OUT SEP 6, 2018 9:15 AM TANK 2 DIESEL OVERFILL ALARM SEP 6, 2018 9:57 AM PROBE OUT SEP 6, 2018 9:16 AM DELIVERY NEEDED SEP 6, 2018 9:16 AM AUG 22, 2018 10:58 AM AUG 10, 2018 1:47 PM TANK 3 PNL SUDDEN LOSS ALARM SEP 6, 2018 9:17 AM PROBE OUT SEP 6, 2018 9:17 AM TANK 4 UNL 2 SIPHON OVERFILL ALARM SEP 6, 2018 9:50 AM JUL 26, 2018 3:46 PM JUL 10, 2018 4:27 AM PROBE OUT SEP 6, 2018 9:14 AM I38200 SEP 10, 2018 9:01 AM I30200 SEP 10, 2018 9:01 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP SEP 6, 2018 10:17 AM SENSOR OUT ALARM SEP 6, 2018 9:45 AM FUEL ALARM 2 UNL1 ANN SEP 6, 2018 10:22 AM FUEL ALARM SEP 6, 2018 10:17 AM SENSOR OUT ALARM 3 DIESEL STP SEP 6, 2018 10:17 AM SENSOR OUT ALARM SEP 6, 2018 9:44 AM FUEL ALARM JUN 4, 2018 10:24 AM FUEL ALARM 4 DIESEL ANN SEP 6, 2018 10:17 AM SENSOR OUT ALARM SEP 6, 2018 9:39 AM FUEL ALARM JUN 25, 2018 9:38 AM FUEL ALARM 5 PNL STP SEP 6, 2018 10:17 AM SENSOR OUT ALARM SEP 6, 2018 9:43 AM FUEL ALARM 6 PNL ANN SEP 6, 2018 10:22 AM FUEL ALARM SEP 6, 2018 10:17 AM SENSOR OUT ALARM 7 UNL2 SIPON STP SEP 6, 2018 10:17 AM SENSOR OUT ALARM SEP 6, 2018 9:46 AM FUEL ALARM 8 UNL2 ANN SEP 6, 2018 10:22 AM FUEL ALARM SEP 6, 2018 10:17 AM SENSOR OUT ALARM 9 DISP 1-2 SEP 6, 2018 11:08 AM FUEL ALARM SEP 6, 2018 10:17 AM SENSOR OUT ALARM SEP 6, 2018 10:12 AM FUEL ALARM 10 DISP 3-4 SEP 6, 2018 10:17 AM SENSOR OUT ALARM SEP 6, 2018 10:14 AM FUEL ALARM SEP 6, 2018 10:04 AM FUEL ALARM 11 DISP 5-6 SEP 6, 2018 10:17 AM SENSOR OUT ALARM SEP 6, 2018 10:11 AM FUEL ALARM SEP 6, 2018 10:04 AM FUEL ALARM 12 DISP 7-8 SEP 6, 2018 10:17 AM SENSOR OUT ALARM SEP 6, 2018 10:10 AM FUEL ALARM SEP 6, 2018 10:04 AM FUEL ALARM 13 TRAN NO. SEP 6, 2018 12:06 PM FUEL ALARM SEP 6, 2018 10:17 AM SENSOR OUT ALARM JUN 23, 2018 9:58 PM FUEL ALARM 14 TRAN SO. SEP 6, 2018 12:11 PM FUEL ALARM SEP 6, 2018 10:17 AM SENSOR OUT ALARM I31600 SEP 10, 2018 9:01 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 V.P.SENSOR DISP 3-4 2 F.M.DISP 1-2 3 F.M.DISP 3-4 4 F.M.DISP 5-6 5 F.M.DISP 7-8 I40200 SEP 10, 2018 9:02 AM I40300 SEP 10, 2018 9:02 AM I34200 SEP 10, 2018 9:02 AM I34700 SEP 10, 2018 9:02 AM IV0100 SEP 10, 2018 9:02 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.02 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% STAGE I TRANSFERS: 1 of 1 PASS EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 18-09-04 10:01:52 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.47 18-08-12 10:02:35 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 18-07-29 10:03:23 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 3:F.M.DISP 5-6 18-07-29 10:03:23 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 18-07-21 10:02:35 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.70 18-07-20 10:02:30 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.68 18-07-19 10:02:36 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.17 18-07-18 10:02:32 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.18 18-07-17 10:02:39 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.92 18-07-16 10:02:37 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.25 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 18-07-22 10:02:18 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.70 17-04-23 10:02:39 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 18.01 17-04-09 10:01:09 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 15-06-02 10:02:05 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.17 13-08-14 10:02:10 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.13 11-01-03 10:01:19 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 88.77 11-01-02 10:01:22 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 90.19 11-01-01 10:01:28 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 89.64 10-12-31 10:01:34 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 55.83 10-11-12 10:01:46 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.07 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 18-09-07 10:02:14 READINESS ISD:PP EVR:PP ISD & EVR READY 18-09-06 10:17:19 READINESS ISD:PP EVR:NN EVR READINESS PENDING 18-09-06 10:17:19 ISD STARTUP 18-09-06 10:17:09 ISD SHUTDOWN 18-08-14 10:02:27 READINESS ISD:PP EVR:PP ISD & EVR READY 18-08-13 10:02:32 READINESS ISD:PP EVR:NP EVR READINESS PENDING 18-08-13 08:34:13 READINESS ISD:PP EVR:NN EVR READINESS PENDING 18-08-13 08:34:13 ISD STARTUP 18-08-13 08:04:09 ISD SHUTDOWN 18-07-30 09:36:05 SENSOR OUT TEST MANUALLY CLEARED Fastrip chester after alarm history Responses Received: I10200 SEP 10, 2018 11:28 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 508079 508515 2 4 PROBE / G.T. 161504 161542 3 INTERSTITIAL BD 202172 202569 4 INTERSTITIAL BD 202533 202714 5 UNUSED 4812041 4748809 6 UNUSED 4809760 4739877 7 UNUSED 4811310 4740807 8 UNUSED 4810181 4741849 9 STP SENSE BOARD 33224 33285 10 RELAY BOARD 14888 14902 11 RELAY BOARD 14955 15036 12 UNUSED 4813085 4747614 13 UNUSED 4809830 4739702 14 UNUSED 4811668 4742760 15 UNUSED 4807351 4742849 16 UNUSED 4811447 4745908 COMM 1 RS232 SERIAL BD 14932 14947 COMM 2 RS232 SERIAL BD 14977 15014 COMM 3 ELEC DISP INT. 101186 101358 COMM 4 UNUSED 4810118 4747060 COMM 5 UNUSED 4811956 4742760 COMM 6 UNUSED 4806399 4739458 I90200 SEP 10, 2018 11:28 AM SOFTWARE REVISION LEVEL VERSION 329.01 SOFTWARE# 346329-100-B CREATED - 09.01.29.15.44 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 SEP 10, 2018 11:28 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 9-10-18 10:29AM T 4 TANK UNL 2 SIPHON PROBE OUT CLEAR 9-10-18 10:16AM T 4 TANK UNL 2 SIPHON OVERFILL ALARM CLEAR 9-10-18 10:15AM T 4 TANK UNL 2 SIPHON PROBE OUT ALARM 9-10-18 10:15AM T 4 TANK UNL 2 SIPHON OVERFILL ALARM ALARM 9-10-18 10:15AM T 1 TANK UNL PROBE OUT CLEAR 9-10-18 10:12AM T 1 TANK UNL OVERFILL ALARM CLEAR 9-10-18 10:12AM T 1 TANK UNL PROBE OUT ALARM 9-10-18 10:12AM T 1 TANK UNL OVERFILL ALARM ALARM 9-10-18 10:11AM T 2 TANK DIESEL PROBE OUT CLEAR 9-10-18 10:07AM T 2 TANK DIESEL OVERFILL ALARM CLEAR 9-10-18 10:07AM T 2 TANK DIESEL PROBE OUT ALARM 9-10-18 10:07AM T 2 TANK DIESEL OVERFILL ALARM ALARM 9-10-18 10:07AM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 9-10-18 10:07AM T 3 TANK PNL PROBE OUT CLEAR 9-10-18 10:05AM T 3 TANK PNL PROBE OUT ALARM 9-10-18 10:04AM T 3 TANK PNL OVERFILL ALARM CLEAR 9-10-18 10:04AM T 3 TANK PNL OVERFILL ALARM ALARM 9-10-18 10:04AM T 4 TANK UNL 2 SIPHON PROBE OUT CLEAR 9-10-18 10:03AM T 3 TANK PNL PROBE OUT CLEAR 9-10-18 10:00AM T 3 TANK PNL PROBE OUT ALARM 9-10-18 9:59AM T 2 TANK DIESEL PROBE OUT CLEAR 9-10-18 9:59AM T 2 TANK DIESEL PROBE OUT ALARM 9-10-18 9:58AM T 1 TANK UNL PROBE OUT CLEAR 9-10-18 9:58AM T 1 TANK UNL PROBE OUT ALARM 9-10-18 9:57AM T 4 TANK UNL 2 SIPHON PROBE OUT ALARM 9-10-18 9:56AM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 9-10-18 9:53AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 9-10-18 9:53AM L 2 ANNULAR UNL1 ANN SENSOR OUT ALARM CLEAR 9-10-18 9:53AM L 8 ANNULAR UNL2 ANN SENSOR OUT ALARM CLEAR 9-10-18 9:53AM L 7 STP SUMP UNL2 SIPON STP SENSOR OUT ALARM CLEAR 9-10-18 9:53AM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 9-10-18 9:53AM L 6 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 9-10-18 9:53AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 9-10-18 9:52AM L 5 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 9-10-18 9:52AM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 9-10-18 9:52AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 9-10-18 9:52AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 9-10-18 9:52AM L14 PIPE TRAN SO. SENSOR OUT ALARM CLEAR 9-10-18 9:52AM L13 PIPE TRAN NO. SENSOR OUT ALARM CLEAR 9-10-18 9:52AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 9-10-18 9:51AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 9-10-18 9:51AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 9-10-18 9:51AM L 6 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 9-10-18 9:51AM L14 PIPE TRAN SO. SENSOR OUT ALARM ALARM 9-10-18 9:51AM L 5 STP SUMP PNL STP SENSOR OUT ALARM ALARM 9-10-18 9:51AM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM ALARM 9-10-18 9:51AM L13 PIPE TRAN NO. SENSOR OUT ALARM ALARM 9-10-18 9:51AM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 9-10-18 9:51AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 9-10-18 9:51AM I11200 SEP 10, 2018 11:28 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME OTHER ISD SENSOR OUT WARN CLEAR 9-10-18 11:27AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 9-10-18 10:08AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 9-10-18 10:08AM T 2 TANK DIESEL INVALID FUEL LEVEL CLEAR 9-10-18 10:08AM T 2 TANK DIESEL INVALID FUEL LEVEL ALARM 9-10-18 10:07AM T 3 TANK PNL LOW TEMP WARNING CLEAR 9-10-18 10:05AM T 3 TANK PNL LOW TEMP WARNING ALARM 9-10-18 10:05AM OTHER ISD SENSOR OUT WARN ALARM 9-10-18 10:02AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 9-10-18 9:59AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 9-10-18 9:58AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 9-06-18 9:17AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 9-06-18 9:16AM OTHER ISD GROSS PRES WARN CLEAR 9-05-18 10:00AM OTHER ISD GROSS PRES WARN ALARM 9-04-18 10:01AM SYSTEM PRINTER ERROR CLEAR 8-29-18 1:42AM SYSTEM PAPER OUT CLEAR 8-29-18 1:42AM SYSTEM PRINTER ERROR ALARM 8-29-18 1:42AM SYSTEM PAPER OUT ALARM 8-29-18 1:42AM SYSTEM PRINTER ERROR CLEAR 8-29-18 1:42AM SYSTEM PAPER OUT CLEAR 8-29-18 1:42AM SYSTEM PRINTER ERROR ALARM 8-29-18 1:42AM SYSTEM PAPER OUT ALARM 8-29-18 1:42AM SYSTEM PRINTER ERROR CLEAR 8-29-18 1:42AM SYSTEM PAPER OUT CLEAR 8-29-18 1:42AM SYSTEM PRINTER ERROR ALARM 8-29-18 1:42AM SYSTEM PAPER OUT ALARM 8-29-18 1:42AM SYSTEM PRINTER ERROR CLEAR 8-29-18 1:42AM SYSTEM PAPER OUT CLEAR 8-29-18 1:42AM SYSTEM PRINTER ERROR ALARM 8-29-18 12:05AM SYSTEM PAPER OUT ALARM 8-29-18 12:05AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 8-23-18 11:08PM T 2 TANK DIESEL DELIVERY NEEDED ALARM 8-22-18 10:58AM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN CLEAR 8-13-18 10:00AM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN ALARM 8-12-18 10:02AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 8-11-18 1:40PM T 2 TANK DIESEL DELIVERY NEEDED ALARM 8-10-18 1:47PM SYSTEM PRINTER ERROR CLEAR 8-03-18 10:56AM SYSTEM PRINTER ERROR ALARM 8-03-18 10:56AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 7-31-18 12:34AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 7-30-18 10:04AM OTHER ISD SENSOR OUT WARN CLEAR 7-30-18 9:36AM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN CLEAR 7-30-18 9:36AM OTHER ISD SENSOR OUT WARN ALARM 7-29-18 10:03AM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN ALARM 7-29-18 10:03AM SYSTEM PRINTER ERROR CLEAR 7-26-18 3:32PM SYSTEM PAPER OUT CLEAR 7-26-18 3:32PM SYSTEM PRINTER ERROR ALARM 7-26-18 3:32PM SYSTEM PAPER OUT ALARM 7-26-18 3:32PM SYSTEM PRINTER ERROR CLEAR 7-26-18 3:32PM SYSTEM PAPER OUT CLEAR 7-26-18 3:32PM I20600 SEP 10, 2018 11:28 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 TANK ALARM HISTORY TANK 1 UNL SETUP DATA WARNING JAN 29, 2009 8:13 AM OVERFILL ALARM SEP 10, 2018 10:11 AM SEP 6, 2018 9:53 AM AUG 2, 2018 9:59 PM SUDDEN LOSS ALARM SEP 6, 2018 9:15 AM AUG 29, 2018 12:34 AM JUL 4, 2018 7:01 AM PROBE OUT SEP 10, 2018 10:12 AM SEP 10, 2018 9:57 AM SEP 6, 2018 9:15 AM TANK 2 DIESEL OVERFILL ALARM SEP 10, 2018 10:07 AM SEP 6, 2018 9:57 AM INVALID FUEL LEVEL SEP 10, 2018 10:07 AM PROBE OUT SEP 10, 2018 10:07 AM SEP 10, 2018 9:58 AM SEP 6, 2018 9:16 AM DELIVERY NEEDED SEP 10, 2018 10:08 AM SEP 10, 2018 9:58 AM SEP 6, 2018 9:16 AM TANK 3 PNL OVERFILL ALARM SEP 10, 2018 10:04 AM SUDDEN LOSS ALARM SEP 6, 2018 9:17 AM PROBE OUT SEP 10, 2018 10:04 AM SEP 10, 2018 9:59 AM SEP 6, 2018 9:17 AM LOW TEMP WARNING SEP 10, 2018 10:05 AM TANK 4 UNL 2 SIPHON OVERFILL ALARM SEP 10, 2018 10:15 AM SEP 6, 2018 9:50 AM JUL 26, 2018 3:46 PM PROBE OUT SEP 10, 2018 10:15 AM SEP 10, 2018 9:56 AM SEP 6, 2018 9:14 AM I38200 SEP 10, 2018 11:28 AM I30200 SEP 10, 2018 11:28 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP SEP 10, 2018 9:51 AM SENSOR OUT ALARM SEP 10, 2018 9:38 AM FUEL ALARM SEP 6, 2018 10:17 AM SENSOR OUT ALARM 2 UNL1 ANN SEP 10, 2018 9:51 AM SENSOR OUT ALARM SEP 10, 2018 9:48 AM FUEL ALARM SEP 6, 2018 10:22 AM FUEL ALARM 3 DIESEL STP SEP 10, 2018 9:51 AM SENSOR OUT ALARM SEP 10, 2018 9:38 AM FUEL ALARM SEP 6, 2018 10:17 AM SENSOR OUT ALARM 4 DIESEL ANN SEP 10, 2018 10:07 AM FUEL ALARM SEP 10, 2018 9:51 AM SENSOR OUT ALARM SEP 10, 2018 9:49 AM FUEL ALARM 5 PNL STP SEP 10, 2018 9:51 AM SENSOR OUT ALARM SEP 10, 2018 9:39 AM FUEL ALARM SEP 6, 2018 10:17 AM SENSOR OUT ALARM 6 PNL ANN SEP 10, 2018 9:51 AM SENSOR OUT ALARM SEP 10, 2018 9:49 AM FUEL ALARM SEP 6, 2018 10:22 AM FUEL ALARM 7 UNL2 SIPON STP SEP 10, 2018 9:51 AM SENSOR OUT ALARM SEP 10, 2018 9:35 AM FUEL ALARM SEP 6, 2018 10:17 AM SENSOR OUT ALARM 8 UNL2 ANN SEP 10, 2018 9:51 AM SENSOR OUT ALARM SEP 10, 2018 9:48 AM FUEL ALARM SEP 6, 2018 10:22 AM FUEL ALARM 9 DISP 1-2 SEP 10, 2018 9:51 AM SENSOR OUT ALARM SEP 10, 2018 9:40 AM FUEL ALARM SEP 6, 2018 11:08 AM FUEL ALARM 10 DISP 3-4 SEP 10, 2018 9:51 AM SENSOR OUT ALARM SEP 10, 2018 9:41 AM FUEL ALARM SEP 6, 2018 10:17 AM SENSOR OUT ALARM 11 DISP 5-6 SEP 10, 2018 9:51 AM SENSOR OUT ALARM SEP 10, 2018 9:44 AM FUEL ALARM SEP 6, 2018 10:17 AM SENSOR OUT ALARM 12 DISP 7-8 SEP 10, 2018 9:51 AM SENSOR OUT ALARM SEP 10, 2018 9:46 AM FUEL ALARM SEP 10, 2018 9:45 AM FUEL ALARM 13 TRAN NO. SEP 10, 2018 9:51 AM SENSOR OUT ALARM SEP 10, 2018 9:42 AM FUEL ALARM SEP 6, 2018 12:06 PM FUEL ALARM 14 TRAN SO. SEP 10, 2018 9:51 AM SENSOR OUT ALARM SEP 10, 2018 9:43 AM FUEL ALARM SEP 6, 2018 12:11 PM FUEL ALARM I31600 SEP 10, 2018 11:28 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 V.P.SENSOR DISP 3-4 2 F.M.DISP 1-2 3 F.M.DISP 3-4 4 F.M.DISP 5-6 5 F.M.DISP 7-8 I40200 SEP 10, 2018 11:28 AM I40300 SEP 10, 2018 11:28 AM I34200 SEP 10, 2018 11:28 AM I34700 SEP 10, 2018 11:28 AM IV0100 SEP 10, 2018 11:28 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.02 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :WARN EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME : 99% STAGE I TRANSFERS: 0 of 0 NOTEST EVR/ISD PASS TIME : 0% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 18-09-10 10:02:20 SENSOR OUT SELFTEST T 4 18-09-04 10:01:52 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.47 18-08-12 10:02:35 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 18-07-29 10:03:23 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 3:F.M.DISP 5-6 18-07-29 10:03:23 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 18-07-21 10:02:35 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.70 18-07-20 10:02:30 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.68 18-07-19 10:02:36 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.17 18-07-18 10:02:32 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.18 18-07-17 10:02:39 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.92 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 18-07-22 10:02:18 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.70 17-04-23 10:02:39 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 18.01 17-04-09 10:01:09 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 15-06-02 10:02:05 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.17 13-08-14 10:02:10 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.13 11-01-03 10:01:19 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 88.77 11-01-02 10:01:22 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 90.19 11-01-01 10:01:28 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 89.64 10-12-31 10:01:34 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 55.83 10-11-12 10:01:46 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.07 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 18-09-10 11:27:26 SENSOR OUT TEST MANUALLY CLEARED 18-09-10 10:02:20 READINESS ISD:PF EVR:NNN CHECK ISD SENSORS 18-09-10 09:54:47 READINESS ISD:PP EVR:NN EVR READINESS PENDING 18-09-10 09:54:47 ISD STARTUP 18-09-10 09:54:43 ISD SHUTDOWN 18-09-07 10:02:14 READINESS ISD:PP EVR:PP ISD & EVR READY 18-09-06 10:17:19 READINESS ISD:PP EVR:NN EVR READINESS PENDING 18-09-06 10:17:19 ISD STARTUP 18-09-06 10:17:09 ISD SHUTDOWN 18-08-14 10:02:27 READINESS ISD:PP EVR:PP ISD & EVR READY SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: Date of Testing: Facility Address: Facility Contact: Phone: Date Local Agency Was Notified of Testing : Name of Local Agency Inspector (if present during testing): 2. TESTING CONTRACTOR INFORMATION Company Name: Technician Conducting Test: Credentials1: CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) __________________ License Number(s): 3. SPILL BUCKET TESTING INFORMATION Test Method Used: Hydrostatic Vacuum Other Test Equipment Used: Equipment Resolution: Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1234 Bucket Installation Type: Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test: Test Start Time (TI): Initial Reading (RI): Test End Time (TF): Final Reading (RF): Test Duration (TF –TI): Change in Reading (RF -RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Comments –(include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician’s Signature:________________________________________________ Date:_________________________ 1 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. Jaco #5562 Fastrip #6 09/10/2018 1640 South Chester Ave Omero Garcia 661-393-7000 8/14/2018 Kris Karns Confidence UST Services, Inc. Frank Amestoy 804904 lake test 0.0625" 12.00" 12.00" 12.00"12.00" 15.00" 15.00" 15.00" 15.00" 30 minutes 30 minutes 30 minutes 30 minutes 9:30am 9:30am 9:30am 9:30am 14.00" 14.00" 14.00" 14.00" 10:30am 10:30am 10:30am 10:30am 14.00" 14.00" 14.00" 14.00" 60 minutes 60 minutes 60 minutes 60 minutes 0.00" 0.00" 0.00" 0.00" 0.0625" 0.0625" 0.0625" 0.0625" 09/10/2018 ✔✔ ✔ ✔✔✔✔ ✔✔✔✔ 87 (1)diesel 81 87 (2) 8374998