Loading...
HomeMy WebLinkAbout2600 WHITE LANE FMC 2013q'.02t Q k HOODS ALARMS SPRINKLER SYSTEMS SPRAY BOOTH AST UST Permit No. Permit No. Permit No. File Number: 3 . 7 7 7 Date Received: 2'-6, -- Address: Permit No. Permit No. Permit No. 0 Business Name: :!fs ke-C._ T.-) - SYSTEM: E BUILDING SQUARE FEET: New Mod. Commercial Hood System Building Sq. Feet: Fire Alarm System Calculation Bldg. Sq. Ft: 1. Fire Sprinkler System 2. Spray FWsh System 3. Aboveground Storage Tank 4. Underground Storage Tank minor modification Underground Storage Tank removal Underground Storage Tank tY Other. INSPECTION LOG Date Time S Signature Comments: -TEd. SCG:9 5,299X5-2 Exe- VR 836 Fra-o exe MONITORING SYSTEM CERTIFICATION For Use ByAll Jurisdictions Within the State ofCalifornia Authority Cited: Chapter 6 7, Health andSafety Code; Chapter 16, Division 3, Title 23, California Code ofRegulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monit9drig system control aenel by the technician who performs the work. A copy of this form must be provided to the tank system owner /operator. The owner /operator must submit a copy ofthis form to the local agency regulating UST systems within 30 days of test date. A. General Information Facility Name: WHITE LN SHELL Site Address: 2600 WHITE LN City: BAKERSFIELD Bldg. No.: Zip: Facility Contact Person: LOUNG CHAO Contact Phone No.: ( ) Make/Model of Monitoring System: TLS -350 Date of Testing/Servicing: 8/21/2013 B. Inventory of Equipment Tested/Cerdfled Check the anorooriate boxes to indicate soecitic eauioment iasnected /serviced: Tank ID: UNL87 Tank ID: PREM91 Z In -Tank Gauging Probe. Model: MAGI Z In -Tank Gauging Probe. Model: MAGI Annular Space or Vault Sensor. Model: 303 Annular Space or Vault Sensor. Model: 303 Z Piping Sump / Trench Sensor(s). Model: 208 Z Piping Sump/ Trench Sensor(s). Model: 208 Fill Sump Sensor(s). Model: 208 Z Fill Sump Sensor(s). Model: 208 Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: Z Electronic Line Leak Detector. Model: VEEDER -ROOT Z Electronic Line Leak Detector. Model: VEEDER -ROOT Z Tank Overfill / High -Level Sensor. Model: BALL FLOAT IS Tank Overfill / High -Level Sensor, Model: BALL FLOAT Other (specify equipment type and model in Section E on Page 2). Other (specify equipment type and model in Section E on Page 2). Tank ID: DIESEL Tank ID: Z in -Tank Gauging Probe. Model: MAGI In -Tank Gauging Probe. Model: Annular Space or Vault Sensor. Model: 303 Annular Space or Vault Sensor. Model: Z Piping Sump / Trench Sensor(s). Model: 208 Piping Sump / Trench Sensor(s). Model: Fill Sump Sensor(s). Model: 208 El Fill Sump Sensor(s). Model: Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: Electronic line LeakDetector. Model: VEEDER -ROOT Electronic Line Leak Detector. Model: Z Tank Overfill / High -Level Sensor. Model: BALL FLOAT Tank Overfill / High -Level Sensor. Model: Other (specify equipment type and model in Section E on Page 2). Other (specify equipment type and model in Section E on Page 2). Dispenser ID: 1 -2 Dispenser ID: 3-4 Z Dispenser Containment Sensor(s). Model: 208 Dispenser Containment Sensor(s). Model: 208 Z Shear Valve(s). Z Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: 5-6 Dispenser ID: 7.8 Dispenser Containment Sensor(s). Model: 208 • Dispenser Containment Sensor(s). Model: 208 ShearValve(s). Z Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser Containment Float(s) and Chain(s). Dispenser ID: 9 -10 Dispenser ID: Z Dispenser Containment Sensor(s). Model: 208 Dispenser Containment Sensor(s). Model: Z Shear Valve(s). Shear Valve(s). Dispenser Containment Float(s) and Chain(s). Dispenser Containment Float(s) and Chain(s). Ifthe facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy ofthe report; (check all that apply): ® System set -up ® Alarm history report Technician Name (print): RICHARD MASON Signature: Certification No.: 63688015297857 -UT License. No.: C611 D40 809850 Testing Company Name: RICH ENVIRONMENTAL Phone No.: (661) 392 -8687 Testing Company Address: 5643 BROOKS CT. BAKERSFIELD, CA 93308 Date ofTesting/Servicing: 821113 Page 1 of 4 UN- 036 —1/4 www.unidoes.org Rev. 01/17/08 Monitoring System Certification D. Results of Testing/Servicing Software Version Installed: 327.04 Complete the follo ing checklist: Yes No* Is the audible alarm operational? Yes No* Is the visual alarm operational? Yes No* Were all sensors visually inspected, functionally tested, and confirmed operational? Yes No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Yes No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) N/A operational? Yes No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? Ifyes: which sensors initiate positive shut -down? (Check all that apply) ® Sump/Trench Sensors; ® Dispenser Containment Sensors. Did you confirm positive shut -down due to leaks and sensor failure /disconnection? ® Yes; No. Yes No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? Ifso, at what percent oftank capacity does the alarm trigger? % Yes* No Was any monitoring equipment replaced? Ifyes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E, below. Yes* No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) Product; Water. Ifyes, describe causes in Section E, below. Yes No* Was monitoring system set -up reviewed to ensure proper settings? Attach set up reports, ifapplicable Yes 1 No* 1 Is all monitoring equipment operational per manufacturer's specifications? In Section E below, describe how and when these deficiencies were or will be corrected. E. Comments: Page 2 of 4 UN- 036 — 2/4 www.unidotLorg Rev. 01 /17/08 Monitoring System Certification F. In -Tank Gauging / SIR Equipment: Check this box iftank gauging is used only for inventory control. Check this box ifno tank gauging or SIR equipment is installed. This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. Complete the following checklist: Yes No* Has all input wiring been inspected for proper entry and termination, including testing for ground faults? Yes No* Were all tank gauging probes visually inspected for damage and residue buildup? Yes No* Was accuracy ofsystem product level readings tested? Yes No* Was accuracy of system water level readings tested? Yes No* Were all probes reinstalled properly? Yes No* Were all items on the equipment manufacturer's maintenance checklist completed? In Section H, below, describe how and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): Cmmnlete the follnwing checklist: Check this box if LLDs are not installed. Yes No* For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? N/A Check all that apply) Simulated leak rate: ® 3 g.p.h.; [10. 1 g.p.h ; [10.2 g.p.h. Yes No* Were all LLDs confirmed operational and accurate within regulatory requirements? Yes No* Was the testing apparatus properly calibrated? Yes No* For mechanical LLDs, does the LLD restrict product flow ifit detects a leak? NIA Yes No* For electronic LLDs, does the turbine automatically shut off ifthe LLD detects a leak? N/A Yes No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled N/A or disconnected? Yes No* For electronic LLDs, does the turbine automatically shut off ifany portion ofthe monitoring system malfunctions N/A or fails a test? Yes No* For electronic LLDs, have all accessible wiring connections been visually inspected? N/A Yes I No* I Were all items on the equipment manufacturer's maintenance checklist completed? In Section M below, describe how and when these deficiencies were or will be corrected. H. Comments: UN -036 — 3/4 Page 3 of 4 www.unidocs.org Rev. olm/os 3+ t ,4— w - i a 1Y` Ttyoa eheady hape a diagrasuibb Am all mOred , pea mgy:tncslu ii, 7atbar d tbis page. with yoar Moolmdag Skswm Cerdflp3h n. On y* IUaor%' Meow *.. Wer lagoon! of-tau And• %_ gmdy ' of for taDow4egnpmeaifmstaedmoAborgyrionavlpwsrsosg'ak anwlar Spa .mss, ftportset• pmts, spig wakes, or odw sacmfty ancs;%uai lor eTuiroaic lit yakdetrotow, and is-tank HgWd laud probes {ifuwJ . iea&de ctfoofj. ia eSpa o ided;'i' tt :datb.s.Sire.P9sie sprepbsudy. .••• . 0 ' of 8, ' 0449 44 pdmssasaoeegg RtwO!!1 ?dttt 0 RICH ENVIRONMENTAL 5643 BROOKS CT. BAKERSFIELD, CA. 93308 OFFICE (661)392 -8687 FAX (661)392 -0621 PRODUCT LINE LEAK DETECTOR TEST WORK SHEET W /0 #: FACILITY NAME: WHITE LANE SHELL FACILITY ADDRESS: 2600 WHITE LANE, BAKERSFIELD PRODUCT LINE TYPE: PRESSURE PRODUCT LEAK DETECTOR TYPE TEST TRIP PASS BELOW P.S.I. OR SERIAL NUMBER 3 G.P.H. FAIL UNL87 L/D TYPE: ELECTRONIC YES 11 PASS SERIAL # VEEDER -ROOT PREM91 L/D TYPE: ELECTRONIC YES 11 PASS SERIAL # VEEDER -ROOT DIESEL L/D TYPE: ELECTRONIC YES it PASS SERIAL # VEEDER -ROOT L/D TYPE YES PASS SERIAL # NO FAIL I CERTIFY THE ABOVE TESTS WERE CONDUCTED ON THIS DATE ACCORDING TO RED JACKET PUMPS FIELD TEST APPARATUS TESTING PROCEDURE AND LIMITATIONS. THE MECHANICAL LEAK DETECTOR TEST PASS / FAIL IS DETERMINED BY USING A LOW FLOW THRESHOLD TRIP RATE OF 3 GALLONS PER HOUR OR LESS AT 10 P.S.I. I ACKNOWLEDGE THAT ALL DATA COLLECTED IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE. TECHNICIAN: RICHARD MASON SIGNATURE: t ( V r DATE: 8/21/13 0• t ,j SWRCB, January 2006 Spill Bucket Testing Report Form Thisform is intendedfor use by contractorsperforming annual testing ofUSTspill containment structures. The completedform and printoutsfrom tests (ifapplicable), should be provided to thefacility owner /operatorfor submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: WHITE LN SHELL Date of Testing: 8/21/13 Facility Address: 2600 WHITE LANE, BAKERFIELD Facility Contact: I Phone: Date Local Agency Was Notified ofTesting: 8/1/13 Name ofLocal Agency Inspector (ifpresent during testing): ERNIE MEDINA 2_ TFSTiNG CONTRArTnR iNFnRMATinN Company Name: RICH ENVIRONMENTAL Technician Conducting Test: RICHARD MASON Credentials': CSLB Contractor X ICC Service Tech. SWRCB Tank Tester 0 Other (Spec) License Number(s): 5297857 -UT 3. SPILL BUCKET TESTING INFORMATION Test Method Used: X Hydrostatic Vacuum Other Test Equipment Used: VISUAL Equipment Resolution: 0.00 Identify Spill Bucket (By Tank Number, Stored Product, etc. t UNL87 2 PREM91 3 DIESEL 4 Bucket Installation Type: Direct Bury X Contained in Sump Direct Bury X Contained in Sump Direct Bury X Contained in Sump Direct Bury Contained in Sum Bucket Diameter: 12" 12" 12" Bucket Depth: 16" 16" 16" Wait time between applying vacuum/water and start oftest: 30MIN 30MIN 30MIN Test Start Time (TO: 1:45 1:45 1:45 Initial Reading (Rj): 16" 16" 16" Test End Time (TF): 2:45 2 :45 2:45 Final Reading (RF): 16" 16" I6" Test Duration (TF — TO: 60MIN 60MIN 60MIN Change in Reading (RF - Rj): 0 0 0 Pass/Fail Threshold or Criteria: 0 0 0 Test Result: X Pass Fail X Pass Fail X Pass []Fail 0 Pass Fail Comments — (include information on repairs made prior to testing, and recommendedfollow -upforfailed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and infull compliance with legal requirements. Technician's Signature: / — Date: 8/21/13 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. SYSTEM SETUP AUG 21, 2013 1:14 PM CUSTOM ALARMS DISABLED MASS /DENSITY n r OAOT nn SYSTEM UNITS U.S. IN -TANK SETUP COMMUNICATIONS SETUP SYSTEM LANGUAGE ENGLISH SYSTEM DATE /TIME FORMAT T 1 :UNL MON DD YYYY HH :MM:SS xM PRODUCT CODE 1 PORT SETTINGS: THERMAL COEFF :.000700 WHITE LANE SHELL TANK DIAMETER : 92.00 COMM BOARD 1 <EDIM ) COM232 2600 WHITE LANE TANK PROFILE : 4 PTS SECURITY BAKERSFIELD FULL VOL 9728 CODE DISABLED 69.0 INCH VOL : 7910 46.0 INCH VOL 4864 COMM BOARD 2 (RS -232) SHIFT TIME 1 DISABLED 23.0 INCH VOL 1818 BAUDBAUD RATEBR : 1200 SHIFT TIME 2 DISABLED ODD SHIFT TIME 3 DISABLED STOP BIT 1 STOPI SHIFT TIME 4 DISABLED FLOAT SIZE: 4.0 IN. DATA LENGTH: DATA RS -232 SECURITY TANK PER TST NEEDED WRN WATER WARNING 2.0 CODE : DISABLED DISABLED HIGH WATER LIMIT: 3.0 TANK TST NEEDED WRNCOMMHOARD3 {FXMOD) MAX OR LABEL VOL: 9728 BAUD RATE : 2400 OVERFILL LIMIT METHOD 8755 STOP BIT I STOP PASS LINEN TEST HIGH PRODUCT 95% DATA LENGTH: 7 DATA 9241 RS -232 SECURITY LINE PER TST NEEDED WRN DELIVERY LIMIT 10% CODE : DISABLED DISABLED 972 DIAL TYPE : TONE LINE ANN TST NEEDED WRN ANSWER ON : 1 RING DISABLED LOW PRODUCT 500 MODEM SETUP STRING LEAK ALARM LIMIT: 99 PRINT TC VOLUMES SUDDEN LOSS LIMIT: 200 DIAL TONE INTERVAL: 32 ENABLED TANK TILT 0.00 PROBE OFFSET 0,00 C AUTO TRANSMIT SETTINGS: VALUE EGNFAT: 60.0 STICK HEIGHT OFFSET SIPHON MANIFOLDED TANKS AUTO LEAK ALARM LIMIT DISABLED Tit: NONE DISABLED ULLAGE: 90% LINE MANIFOLDED TANKS AUTO HIGH WATER LIMIT T #: NONE DISABLED H- PROTOCOL DATA FORMATAUTOOVERFILLLIMITHEIGHTDISABLEDPRECISIONTESTDURATION LEAK MIN PERIODIC: 10% AUTO LOW PRODUCT HOURS: 12 972 DISABLED DAYLIGHT SAVING TIME AUTO THEFT LIMIT ENABLED LEAK MIN ANNUAL 10% DISABLED START DATE 942 AUTO DELIVERY START APR WEEK 1 SUNDISABLEDSTARTTIMEAUTODELIVERYEND2:00 AM PERIODIC TEST TYPE DISABLED END DATE STANDARD AUTO EXTERNAL INPUT ON OCT WEEK 6 SUN DISABLED END TIME ANNUAL TEST FAIL AUTO EXTERNAL INPUT OFF 2:00 AM ALARM DISABLED DISABLED AUTO SENSOR FUEL ALARM RE- DIRECT LOCAL PRINTOUT PERIODIC TEST FAIL DISABLED DISABLED ALARM DISABLED AUTO SENSOR WATER ALARM DISABLED EURO PROTOCOL PREFIX GROSS TEST FAIL AUTO SENSOR OUT ALARM S ALARM DISABLED DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF SYSTEM SECURITY CODE : 000000 TANK TEST NOTIFY: OFF RECEIVER SETUP: MAINTENANCE HISTORY TNK TST SIPHON BREAK:OFF DISABLED NONE DELIVERY DELAY : 15 MIN PUMP THRESHOLD : 10.00% TANK CHART SECURITY DISABLED CUSTOM ALARMS DISABLED MASS /DENSITY n r OAOT nn LEAK TEST METHOD TEST ON DATE : ALL TANK FEB 6, 2007 START TIME :.DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED LEAK TEST REPORT FORMAT NORMAL PRESSURE LINE LEAK SETUP A 1:87 STP TYP:2.0i3,0IN FIBERGLASS 2.0IN DIA LEN: 150 FEET 3.0IN DIA LEN: 0 FEET SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 0 PSI T 1:UNL DISPENSE MODE: STANDARD SENSOR: NON— VENTED PRESSURE OFFSET: O.OPSI 8 2:91 STP TYP:2.0i3.0IN FIBERGLASS 2.0IN DIA LEN: 150 FEET 3.0IN DIA LEN: 0 FEET SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE 0 PSI T 2:PREM DISPENSE MODE: STANDARD SENSOR: NON— VENTED PRESSURE OFFSET: O.OPSI T 3:DIESEL ' T'2:PREM PRODUCT CODE 3 PRODUCT CODE 2 THERMAL COEFF 000450 THERMAL COEFF 000700 TANK DIAMETER 92.00 TANK DIAMETER 92.00 TANK PROFILE 4 PTS TANK PROFILE 4 PTS FULL VOL 9728 FULL VOL 9728 69.0 INCH VOL 7910 69.0 INCH VOL 7910 46.0 INCH VOL 4864 46.0 INCH VOL 4864 23.0 INCH VOL 1818 23.0 INCH VOL 1818 FLOAT SIZE: WATER WARNING HIGH WATER LIMIT: MAX OR LABEL VOL: OVERFILL LIMIT : HIGH PRODUCT DELIVERY LIMIT 4.0 IN. 2.0 3.0 LOW PRODUCT LEAK ALARM LIMIT: SUDDEN LOSS LIMIT: TANK TILT PROBE OFFSET 9728 92% 8949 97% 9436 109 972 500 99 200 0.00 0.00 SIPHON MANIFOLDED TANKS T#: NONE LINE MANIFOLDED TANKS T #: NONE LEAK MIN PERIODIC: 10% 972 LEAK MIN ANNUAL 10% 972 FLOAT SIZE: WATER WARNING HIGH WATER LIMIT: MAX OR LABEL VOL: OVERFILL LIMIT : HIGH PRODUCT . DELIVERY LIMIT 4.0 IN. 2.0 3.0 LOW PRODUCT LEAK ALARM LIMIT: SUDDEN LOSS LIMIT: TANK TILT PROBE OFFSET 9728 90% 8755 959 9241 1046 972 500 99 220 0.00 0.00 SIPHON MANIFOLDED TANKS T #: NONE LINE MANIFOLDED TANKS T #: NONE LEAK MIN PERIODIC: 10: 972 LEAK MIN ANNUAL 10s: 972 PERIODIC TEST TYPE PERIODIC TEST TYPE STANDARD STANDARD ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY : 15 MIN PUMP THRESHOLD : 10.0 ANNUAL TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED GROSS TEST FAIL ALARM DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF DELIVERY DELAY 15 MIN PUMP THRESHOLD 10.009 PLLD LINE DISABLE SETUP Q 1:87 STP LIQUID SENSOR ALMS L 3:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL Q 2:91 STP LIQUID SENSOR ALMS L 3:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L12:FUEL ALARM L 3:SENSOR OUT ALARM L 4 :SENSOR OUT ALARM L 5:SENSUR (flit rtl,r,RM L 6:SENSOR otrr ALt xvi L 7:SENSOR OUT HLARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL :FLOW COLLECT FAIL Q 3 :DIESEL STP LIQUID SENSOR ALMS L 6:FUEL ALARM L 7 :FUEL ALARM L15:FUEL ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L15:SENSOR OUT ALARM LIQUID SENSOR SETUP L 1:DSL TRI -STATE (SINGLE FLOAT) CATEGORY : PIPING SUMP L 2:VENT TRI -STATE (SINGLE FLOAT) CATEGORY : OTHER SENSORS L 3:DISP 1 -2 TRI -STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN L 4:DIS 3 -4 TRI -STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN i L 5:DIS 5 -6 TRI -STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN L 6:DIS 7 -8 TRI -STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN L 7:DIS 9 -10 TRI -STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN L 9:87 STP TRI -STATE (SINGLE FLOAT) CATEGORY : STP SUMP L10:87 ANN DUAL POINT HYDROSTATIC CATEGORY : ANNULAR SPACE L11:87 FIL TRI -STATE (SINGLE FLOAT) CATEGORY : PIPING SUMP L12:91 STP TRI -STATE (SINGLE FLOAT) CATEGORY : STP SUMP L13:91 ANN DUAL POINT HYDROSTATIC CATEGORY : ANNULAR SPACE L14:91, FIL TRI -STATE (SINGLE FLOAT) CATEGORY : PIPING SUMP L15:DSL STP TRI -STATE (SINGLE FLOAT) CATEGORY : STP SUMP L16:DSL ANN DUAL POINT HYDROSTATIC CATEGORY : ANNULAR SPACE Q 3 :DIESEL STP ' TYP :2.0/3.OIN FIBERGLASS 2.0IN DIA LEN: 150 FEET 3.01N DIA LEN: 0 FEET SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO LOW PRESSURE : 0 PSI T 3:DIESEL DISPENSE MODE: STANDARD SENSOR: NON- VENTED PRESSURE OFFSET: 0.OPSI LINE LEAK LOCKOUT SETUP LOCKOUT SCHEDULE DAILY START TIME: DISABLED STOP TIME : DISABLED SOFTWARE REVISION LEVEL VERSION 327.04 SOFTWARE# 346327 -100 -E CREATED - 07.02.06.10.28 S- MODULE# 330160 -004-a SYSTEM FEATURES: PERIODIC IN -TANK TESTS ANNUAL IN -TANK TESTS ISD PMC ALARM HI6 TUXY klrl OKI n r izu,i n tA i vx Y xarvx 1 SENSOR ALARM - - - -- SENSOR ALARM - - - -- L 4:DIS 3-4 L 1 :DSL OTHER SENSORS DISPENSER PAN PIPING SUMP AUG 21, 2013 2:55 PM SENSOR OUT ALARM SENSOR OUT ALARM AUG 21, 2013 2 :55 PM AUG 21, 2013 2:54 PM SENSOR OUT ALARM SENSOR OUT ALARM AUG 21. 2013 2:51 PM AUG 21. 2013 2:50 PM FUEL ALARM FUEL ALARM AUG 21. 2013 2:48 PM AUG 21. 2013 2:35 PM xxxx9 END xxxxx x0xxx END xxxxx ALARM HISTORY REPORT ALARM HISTORY REPORT SENSOR ALARM - - - -- SENSOR ALARM - - - -- L S:DIS 5 -6 L 2:VENT DISPENSER PAN OTHER SENSORS SENSOR OUT ALARM FUEL ALARM AUG 21, 2013 2:55 PM AUG 21. 2013 3:50 PM SENSOR OUT ALARM SETUP DATA WARNING AUG 21, 2013 2:50 PM AUG 21, 2013 3:50 PM FUEL ALARM FUEL ALARM AUG 21. 2013 2:47 PM AUG 21. 2013 3:16 PM xxxxx END xxxxx xxxxx END xxxxx ALARM HISTORY REPORT ALARM HISTORY REPORT SENSOR ALARM - - - -- SENSOR ALARM - - - -- L 6:DIS 778 L 3:DISP 1 -2 DISPENSER PAN DISPENSER PAN SENSOR OUT ALARM SENSOR OUT ALARM AUG 21, 2013 2:55 PM AUG 21, 2013 2:55 PM SENSOR OUT ALARM SENSOR OUT ALARM AUG 21. 2013 2:50 PM AUG 21, 2013 2:51 PM FUEL ALARM FUEL ALARM AUG 21, 2013 2:46 PM AUG 21, 2013 2 :49 PM SMARTSENSOR SETUP s 1 :DIS 1 -2 AFM CATEGORY AIR FLOW METER s 2:DIS 3 -4 AFM CATEGORY AIR FLOW METER s 3:DIS 5 -6 AFM CATEGORY AIR FLOW METER s 4:DIS 7 -8 AFM CATEGORY AIR FLOW METER s 5:DIS 9 -10 AFM CATEGORY AIR FLOW METER s 6 :PRES SENS CATEGORY VAPOR PRESSURE s B:ATM CATEGORY ATM P SENSOR EVR /ISD SETUP EVR TYPE: VACUUM AS81ST VACUUM ASSIST r,'PE HEALY VAC J% v J ALARM HISTORY REPORT SENSOR ALARM - - - -- L13:91 ANN ANNULAR SPACE LOW LIQUID ALARM AUG 21. 2013 2:56 PM SENSOR OUT ALAN( AUG 21. 2013 2:54 PM LOW LIQUID ALARM AUG 21, 2013 2:52 PM x % X END Wxxxx ALARM HISTORY REPORT SENSOR ALARM -- L14:91 FIL PIPING SUMP SENSOR OUT ALARM AUG 21, 2013 2:55 PM SENSOR OUT ALARM AUG 21. 2013 2:51 PM FUEL ALARM AUG 21, 2013 2 :34 PM X X m x X END m* X m X ALARM HISTORY REPORT SENSOR ALARM - - - -- L15:DSL STP STP SUMP SENSOR OUT ALARM AUG 21. 2013 2:55 PM SENSOR OUT ALARM AUG 21, 2013 2:51 PM FUEL ALARM AUG 21, 2013 2:43 PM ALARM HISTORY REPORT SENSOR ALARM - - - -- 1.10:87 ANN ANNULAR SPACE LOW LIQUID ALARM AUG 21. 2013 2:56 PM SENSOR OUT ALARM AUG 21. 2013 2:55 PM LOW LIQUID ALARM AUG 21. 2013 2:52 PM x X x x X END X x* x x ALARM HISTORY REPORT SENSOR ALARM - - - -- 1.11:87 FIL PIPING SUMP SENSOR OUT ALARM AUG 21. 2013 2:55 PM SENSOR OUT ALARM AUG 21. 2013 2:61 PM FUEL ALARM AUG 21, 2013 2:31 PM xxxxX END ***X* ALARM HISTORY REPORT SENSOR ALARM - - - -- L12:91 STP STP SUMP SENSOR OUT ALARM AUG 21. 2013 2:55 PM SENSOR OUT ALARM AUG 21, 2013 2:51 PM FUEL ALARM AUG 21, 2013 2:32 PM ALARM HISTORY REPORT SENSOR ALARM - - - -- L 7:DIS 9 -10 DISPENSER PAN SENSOR OUT ALARM AUG 21. 2013 2:55 PM SENSOR OUT ALARM AUG 21,, 2013 2:50 PM FUEL ALARM AUG 21. 2013 2:46 PM x x x x x END X X x x x ALARM HISTORY REPORT SENSOR ALARM - - - -- L 8: OTHER SENSORS x x x x x END x X x x X ALARM HISTORY REPORT SENSOR ALARM - - - -- L 9:87 STP STP SUMP SENSOR OUT ALARM AUG 21. 2013 2:54 PM SENSOR OUT ALARM AUG 21, 2013 2:51 PM FUEL ALARM AUG 21. 2013 2:30 PM i%t ALARM HISTORY REPORT SENSOR ALARM - - - -- Q 2 :91 STP PLLD SHUTDOWN ALARM AUG 21, 2013 2:55 PM PLLD SHUTDOWN ALARM AUG 21, 2013 2:50 PM PLLD SHUTDOWN ALARM AUG 21, 2013 2:49 PM PLLD SHUTDOWN ALARM AUG 21, 2013 2:48 PM PLLD SHUTDOWN ALARM AUG 21, 2013 2:47 PM PLLD SHUTDOWN ALARM AUG 21, 2013 2:46 PM PLLD SHUTDOWN ALARM AUG 21, 2013 2:46 PM PLLD SHUTDOWN ALARM AUG 21. 2013 2:44 PM PLLD SHUTDOWN ALARM AUG 21, 2013 2:44 PM LLD SHUTDOWN ALARM 4UG 21, 2013 2:32 PM PLLD SHUTDOWN ALARM AUG 21. 2013 2:49 PM PLLD SHUTDOWN ALARM AUG 21. 2013 2:48 PM PLLD SHUTDOWN ALARM AUG 21, 2013 2 :47 PM PLLD SHUTDOWN ALARM AUG 21. 2013 2:46 PM PLLD SHUTDOWN ALARM AUG 21, 2013 2:46 PM PLLD SHUTDOWN ALARM AUG 21, 2013 2:44 PM PLLD SHUTDOWN ALARM AUG 21, 2013 2:44 PM PLLD SHUTDOWN ALARM AUG 21. 2013 2:30 PM PLLD SHUTDOWN ALARM MAR 2, 2013 10:01 AM ALARM HISTORY REPORT b SENSOR ALARM - - - -- 3> '0 L16:DSL ANN d ANNULAR SPACE ALARM HISTORY REPORT LOW LIQUID ALARM AUG 21, 2013 2:56 PM SENSOR ALARM - - - -- Q 1:87 STP SENSOR OUT ALARM PLLD SHUTDOWN ALARM AUG 21. 2013 2:54 PM AUG 21. 2013 2:54 PM 0 ca Z LOW LIQUID ALARM W AUG 21. 2013 2 :52 PM PLLD SHUTDOWN ALARM AUG 21. 2013 2:49 PM PLLD SHUTDOWN ALARM AUG 21. 2013 2:48 PM PLLD SHUTDOWN ALARM AUG 21, 2013 2 :47 PM PLLD SHUTDOWN ALARM AUG 21. 2013 2:46 PM PLLD SHUTDOWN ALARM AUG 21, 2013 2:46 PM PLLD SHUTDOWN ALARM AUG 21, 2013 2:44 PM PLLD SHUTDOWN ALARM AUG 21, 2013 2:44 PM PLLD SHUTDOWN ALARM AUG 21. 2013 2:30 PM PLLD SHUTDOWN ALARM MAR 2, 2013 10:01 AM xxxxx END xxxxx ALARM HISTORY REPORT SENSOR ALARM - - - -- L 1:DSL PIPING SUMP SENSOR OUT ALARM AUG 21. 2013 2:54 PM SENSOR OUT ALARM AUG 21. 2013 2:50 PM FUEL ALARM AUG 21, 2013 2:35 PM b 0 9D t irr. 3> '0 C7 m d b tV til r iSi to to to aQ O, GQ pr0 0 ca ZW aNN N G1i N 2> m a` Ct3> to t t w+ xxxxx END xxxxx ALARM HISTORY REPORT SENSOR ALARM - - - -- L 1:DSL PIPING SUMP SENSOR OUT ALARM AUG 21. 2013 2:54 PM SENSOR OUT ALARM AUG 21. 2013 2:50 PM FUEL ALARM AUG 21, 2013 2:35 PM b 0 9D t irr. C7 m d b N b t 5 v 3 N0 to aQ O, G7 pr0 0 caZ b j N 2> m a` 3 t t MONITOR CERT. FAILURE REPORT SITE NAME: WHITE LANE SHELL DATE: 8/21/13 ADDRESS: 2600 WHITE LANE TECHNICIAN: RICHARD MASON CITY: BAKERSFIELD SIGNATURE: ! V REPAIRS: NONE PARTS INSTALLED: NONE THE ABOVE NAMED PERSON TAKES FULL RESPONSIBILITY OF NOTIFYING THE APPROPRIATE PARTY TO HAVE CORRECTIVE ACTION TAKEN TO REPAIR THE ABOVE LISTED PROBLEMS AND NOTIFYING RICH ENVIRONMANTAL FOR ANY NEEDED RETESTING. THIS ALSO RELEASES RICH ENVIRONMENTAL OF ANY FINES OR PENALTIES OCCURING FROM NON - COMPLIANCE. A COPY OF THIS DOCUMENT HAS BEEN LEFT ON -SITE FOR YOUR CONVIENENCE. BAKERSFIELD CITY FIRE DEPARTMENT - INSPECTION RECORD Post this Card at the Job Site and DO NOT Remove for Duration of Work Inspection Request Phone No. (661) 326 -3979 UST NEW INSTALL DESCRIPTION DATE SIGNATURE BACKFILL PRIMARY PIPE SECONDARY PIPE SECONDARY CONTAINMENT SENSORS AUTHORIZATION FOR FUEL ELECTRICAL SEAK -OFF C- -- TANK TESTING __ - - _ _ t G UST REMOVAL DESCRIPTION DATE SIGNATURE AST NEW INSTALL DESCRIPTION DATE SIGNATURE MODIFICATIONS MINOR / MAJOR AST REMOVAL DESCRIPTION DATE SIGNATURE EVR UPGRADE PIRM TO OPERATION_OF ANY SYSTEM, BALL UST AND /OR AST SYSTEMS SHALL BE INSTALLCOMPLETE AND ACCEPTED BY MISC. ACTIVITY THE BAKERSFIELD CITY FIRE DEPARTMENT., FIRE DEPARTMENT (FINAL) REMARKS: BUILDING ADDRESS: c2Cc00 77777 LK JOB DESCRIPTION: t= iA,& L OCCUPANCY TYPE: OWNER: ke L PERMIT NO. 1,3 - CONTRACTOR: c L PHONE # S 2 - 9f7 FD 1743 BILLING & PERMIT STATEMENT FPERIMIT NO.: B 1A B R S P I D 4 FIRE ARrAr r BAKERSFIELD FIRE DEPT. Prevention Services 1600 Truxtun Ave Ste 401 Bakersfield CA 93301 Tel.: (661) 326 -3979 • Fax: (661) 852 -2171 All permits must be reviewed, stamped, and approved PRIOR TO BEGINNING WORK ON THAT PROJECT. Alarms - New & Modifications - (Minimum Charge) $280.00 , SITE INFORMATION LOCATION OF PROJEC PROPERTY OWNER Ck STARTING DATE QM ION DATE NAME PROJECTNAME , , l ADDRESS PHONE NO. PROJECTADDRESS CnY STATE ZIPCODE CONTRACTOR INFORMATION CONTRACTOR NAME CA LICENSE NO. TYPE OF LICENSE. EXPIRATION DATEJFYY13'cS R C tt O SO t 1>40AHA 3c 20l PHONE NO. g 2 -8 CONTRACTOR COMPANY NAME IG r )V FAX NO. Oo ADDRESS CITY ZlPwut 9:6 All permits must be reviewed, stamped, and approved PRIOR TO BEGINNING WORK ON THAT PROJECT. Alarms - New & Modifications - (Minimum Charge) $280.00 , 98 Over 10,000 Sq. Ft. Sq. Ft x.028 = Permit fee 84 98 Sprinklers - New & Modifications - (Minimum Charge) 280.00 84 98 Over 10,000 Sq. Ft Sq. Ft x.028 = Permit fee 84 98 Minor Sprinkler Modifications (< 10 heads) 96.00 [Inspection Only] 84 98 Commercial Hoods - New & Modifications 470.00 84 98 Additional Hoods 58.00 84 98 Spray Booths - New & Modifications 470.00 84 98 Aboveground Storage Tanks (Installation/Insp.-1 0 Time) 180.00 82 Additional Tanks 96.00 82 Aboveground Storage Tanks (RemovaUlnspection) 109.00 82 Underground Storage Tanks (Installation. /Inspection) 878.00 (per tank) 82 Underground Storage Tanks (Modification) 878.00 (persite) 82 Underground Storage Tanks (Minor Modification) 167.00 82 Underground Storage Tanks (Removao 573.00 (per tank) 84 Oilwell (Installation) 96.00 84 Mandated Leak Detection (Testing) / Fu Monit. rt/SB989. Note: $96.00 for each type of test / per site heduled at the same dme) C) n „ /1 82 Tents 96.00 (per tend 84 Pyrotechnic - (Per event, Plus Insp. Fee @ $96 per hour) 96.00 + (5 hrs. min. standby fee /Inspection) -- $576..00 84 After hours inspection flee 121.00 84 RE- INSPEC77ON(S) / FOLLOW -UP INSPECTION(S) 96.00 (per hour) 84 Portable LPG (Propane): NO. OF CAGES? _ 96.00 84 Explosive Storage 266.00 84 Copying & File Research (File Research Fee $50.00 per hr) 250 per page 84 Miscellaneous 84 FD 2021 (Rev. 06/07) 1 •ORIGINAL WHrTE (to Treasury) 1- YELLOW (to File) 1 -PINK (to Customer) UNDERGROUND STORAGE TANKS APPLICATION TO PERFORM ELD /LINE TESTING/ SB989 SECONDARY CONTAINMENT TESTING/TANK TIGHTNESS TEST AND FUEL MONITORING CERTIFICATION Please note that these are separate Individual tests and will be charged per separate type test accordingly.) PERMIT # ARA Aftsp I np wfiBi Asrmr r BAKERSFIELD FIRE DEPARTMENT Prevention Services Q10 k E-t 5 -mF-ET Bakerstield, CA 93301 Phone: 661-326-3979 • Fax: 661-852-2171 Page 1 of 1 ENHANCED LEAK DETECTION SB -989 SECONDARY CONTAINMENT TANK TIGHTNESS 1 f EL MONITORING CERTIFICATIO SIT FACILITY NAME ® PHONE 9 OF CONTACT PERSON ADDRESS OWNER NAME OPERATOR NAME PERMIT TO OPERATE # OF TANKS TO BE TESTED: IS PIPING GOING TO BE TESTED? YES NO TANK a# VOLUME CONTENTS I a 15 TANK:TESTING:COMPANY;_ . TESTING COMPANY NAME $ PHONE it OF CONTACT PERSON MAILING ADDRESS 5tn -13 t3C oo c5 CrT. - F.PrK+R.SF 1E.t -D C °13308 NAME & PHONE # OF TESV OR SPECIAL INSP CT CERTIFICATION S 1809 GSo DATE & TIME TEST TO BE C CTS ^ C1• \ Y l ICC 3 TEST METHOD APPLICANT SIGNATUR DATE YHIS APPLICATION BECOMES A PERMIT WHEN APPROVED APPROVED BY DATE FD2095 (Rev 03/08)