HomeMy WebLinkAbout4540 EASTON DRIVE AST 2011HOODS ALARMS SPRINKLER SYSTEMS SPRAY BOOTH AST UST
Permit No. Permit No. Permit No. Permit No. Permit No. Permit No.
11- 1661Y 67Fr0 ANNE
File Number. 3=;--/
Date Received: to — I (
Address: 4 40
Bakersfield, CA 933.
Business Name: -26d ' - Lt'oj -e_ o Lam,
SYSTEM: I L BUILDING SQUARE FEET:
New Mod.
Commercial Hood System
Fire Alarm System
Fire Sprinkler System
Spray Finish System
Aboveground Storage Tank
0 Underground Storage Tank
minor
modification Underground Storage Tank
removal Underground Storage Tank
Other.
Comments:
Building Sq. Feet:
Calculation Bldg. Sq. Ft: 1.
2.
c
cE O .
0-) 4.
INSPECTION LOG
Date Time
Signature
Signature
BAKERSFIELD CITY FIRE DEPARTMENT -- INSPECTION RECORD
Post this Card at the Job Site and DO NOT Remove for Duration of Work
Inspection Request Phone No. (661) 326 -3979
UST NEW INSTALL
DESCRIPTION DATE SIGNATURE
BACKFILL
L—:"j .+Q rj PERMIT NO.
PRIMARY PIPE
44 Ak PHONE # Z -1 (o
SECONDARY PIPE
SECONDARY CONTAINMENT
SENSORS
AUTHORIZATION FOR FUEL
ELECTRICAL SEAK -OFF
TANK TESTING
UST REMOVAL
DESCRIPTION DATE SIGNATURE
EVR UPGRADE
MISC. ACTIVITY
REMARKS:
AST NEW INSTALL
DESCRIPTION DATE SIGNATURE
1 MODIFICATIONS MINOR / MAJOR i
AST REMOVAL
DESCRIPTION DATE SIGNATURE
PRIOR TO OPERATION OF ANY SYSTEM,
ALL UST AND /OR AST SYSTEMS SHALL BE
INSTALL, COMPLETE AND ACCEPTED BY
THE BAKERSFIELD CITY FIRE DEPARTMENT.
FIRE DEPARTMENT (FINAL)
BUILDING ADDRESS: Q
JOB DESCRIPTION: 5--' OCCUPANCY TYPE:
OWNER: dd L—:"j .+Q rj PERMIT NO.
CONTRACTOR: 44 Ak PHONE # Z -1 (o
FD 1743
M
2010 CBC (2009 IBC)
All design not shown below is by others
1000 gal. Propane Tank Anchorage
Roofline Supply
4540 Easton Dr
Bakersfield CA
Contractor: Wholesale Fuels
6/16/2011
Sheet 1 of 'I
Project No. 18001
Scope of Work: These calculations are for the seismic anchorage of a propane tank in Bakersfield, CA.
Earthquake Design Data:
Occupancy Category: II Latitude ( °): 35.3698 Sr. (g): 1.153
Importance Factor: 1.00 Longitude ( °): - 119.0532 Sl (g): 0.415
Site Classification: D Basic SFRS: Tank, Unbraced Legs
Seismic Category: D Analysis Procedure: Equivalent Lateral Force Method
Seismic Response Coefficient, Cs, FP /WP: 0.399 Design Base Shear, pQE (k): 2.41
Response Modification Factor, R, RP: 2.00
Wind Design Data: I i
Occupancy Category: II Basic Wind Speed, 3- Second Gust (mph): 85
Importance Factor: 1.00 Building Enclosure Classification: NA
Wind Exposure: C Internal Pressure Coefficient: NA
Exterior Components and Cladding Design Pressure for Use by Others (psf) NA
Design Dead Loads:
Tank dead load, empty (k): 1.8
Propane specific weight (# /gal): 4.23
Tank volume (gal): 1000
Total tank dead load (k): 6.03
Soil Design Characteristics I Conservatively Assume 2/3 of 2010 CBC Table 1806.2 Class 5 Soil
Allowable vertical soil bearing pressure (psf): 1000
Allowable lateral soil bearing pressure (psf): 66.7
le
i•7 No. 52710
e
Exp.6'30'1 2
7"
4
1000 gal. Propane Tank Anchorage
Sheet d- of A/
Project No. 18001
Seismic Coefficient: ASCE 7 12.8, 15.4, 15.5.3: Non - building structure (tank, unbraced legs)
Ss: 1.153 Fa: 1.04 SMS: 1.20 SDS: 0.798
St: 0.415 F,,: 1.59 SMJ: 0.66 Sol: 0.439
R: 2.0 I: 1.00 T (sec): 0.19 TL (sec): 12
00: 2.00 hn: 19.60 x: 0.75 Site Classification: D
Cd: 2.50 Ct: 0.02 Seismic Category: D
Code 12.8 -2 12.8 -3 12.8 -4 12.8 -5 12.8 -6 15.4 -2 Cs = 0.399
Cs = 0.40 1.18 75.80 0.01 0.10375 0.166 1 7Cs = 0.279
E (k): 2.41
Seismic forces govern by inspection.
1000 gal. Propane Tank Anchorage
Sheet3 of 4
Project No. 18001
L 0.91) +1.6W +1.61-1 0.00 1 5.43
Load Combination Analysis IBC2006 /CBC2007 (LRFD)
Governing Load (k)
D(l), Vert: 6.03 D(2 ), Vert: 0 D(3), Vert: 0 D(4), Vert• 0
Svert: 0 LVert: 0 Lrvert: 0 QE (seismic): 2.41 0': 1
WHOrIZ 0 WVe,: 0 SDS: 0.798 P: 1
L.C. # Formula H. (k) Vu (k)
1 1.4(D + F) 0.00 8.44
2 1.2(D + F + T) + 1.6(L + H) + 0.5(Lr or S or R) 0.00 7.24
3 1.21) + 1.6(L,or S or R) + (L or 0.8W) 0.00 7.24
4 1.21) + 1.6W + L + 0.5(Lr or S or R) 0.00 7.24
L 0.91) +1.6W +1.61-1 0.00 1 5.43
LRFD /ASD
Checking load combinations 5, 7 at propane tank, foundation overturning
LC 5: QE
Hu k : 2.41 Vu k : 8.20
Assume CG = centroid of equipment = H force application height
Ht of CG (ft) = 2.15 bw (ft): 2.75
HT of tank (ft) = 4.29
Summing moments clockwise about point A:
SM:2.41x2.15 +8.2x1.38 +By, ux2.75 =0
B u k: 6_0 Auk: 2.22
1000 gal. Propane Tank Anchorage
Sheet Y of 4
Project No. 18001
2' -9"
LC 7:
Hu k: 2.41 Vu k: 4.46
Summing moments clockwise about point A:
SM:2.41x2.15 +4.46x1.38 +BV, ux2.75 =0
Bu k:. 4_1 Auk: 0.35
No uplift: tank can be supported on ground with 5/8 "0 ground anchors or anchor bolts to conc.
anchors: 4 Hu per anchor (k): 0.60 H per anchor (k): 0.42
Anch 0 (in): 0.625 Min edge dist (in): 6.25 H allow (k): 2.95 OK
Check max bearing pressure: Assume tank frame evenly loads slab as line load
B u (k): 6_0 P do (k): 4.60 Support L (ft): 15.00
Soil br'g w (ft): 0_5 F ksf): 1.00 fp (ksf): 0.61 OK
r
7
v
v
D
NNtla
7
Y
a
4
Oi
6UN
Ln
7
N3OTtl
07i6
Ln
D
C
3tlia
CDF, LntlN
7n7
tl
YC6N
D
iN
N3
N
C
N
DCt
L
4
N
VICINITY MAP
APN: 332 - 332 -22
ti
SITE PLAN 61/256" = 1' -0"
ALL PROPERTY LINES AND DIMENSIONS SHOWN ARE RECOMMENDED TO BE VERIFIED
WITH A BOUNDARY SURVEY PRIOR TO GON5TRUGTION
APN: 332 - 332 -22
AUG 0 8 Z011
0
is
a
ro
a
0N
co
co
C3
0
ofa
NW0N
0
o,
0
ULn
0V)
0
v
3
30
a
o,
a
0
0
ip
i
0mc
3
LA
CO
Lnc
v
0a
cl6
YC6V
1
0
N
v34-
0!
6Nd
OS3
CL
w
mWrA:4
PROPOSED 1000
CAL. TANK (5Y
OTHERS)
E) 6" GONG.
SLAB, 5EE
51TE PLAN
U,
EXISTING A.G.
PAVINC7
TANK ACHORAGE
SECTION
TANK SUPPORT
FRAME BY OTHERS
DRILL (4) 3/4 " (Px5" DEEP HOLE
AND PLACE W(P TREADED
ROD TO FULL DEPTH IN HILTI
HIT RE 500 5D EPDXY PER
H ILT 15PEG I F I GATI ON5.
IIAIue-1
1
L —i
I
DIA.
TYPICAL PIPE BOLLARD
DETAIL
GONG. GROWN
6 "(P STD. PIPE
FILL w/ GONG.
COLOR A5 5EL.
A.G. PAVING
WHERE OCCURS)
GEMENT WASH
AT A.G. PAVING)
GONG. SLAB
WHERE OGCUR5)
i / /-
j
1000 gal. Propane Tank Anchorage
Roofline Supply
2010 CBC (2009 IBC) 4540 Easton Dr
Bakersfield CA
Contractor: Wholesale Fuels
All design not shown below is by others 6/16/2011
Sheet of
Project No. 18001
Scope of Work: These calculations are for the seismic anchorage of a Propane tank in Bakersfield CA
Earthquake Design Data:
Occupancy Category: II Latitude ( °): 35.3698 Ss (g): 1.153
Importance Factor: 1.00 Longitude ( °): - 119.0532 Sl (g): 0.415
Site Classification: D Basic SFRS: Tank, Unbraced Legs
Seismic Category: D Analysis Procedure: Equivalent Lateral Force (!Method
Q
Response Modification Factor, R, RP: 2.00
Wind Design Data:
UJ
Importance Factor: 1.00 Building Enclosure Classification: NA
m
Exterior Components and Cladding Design Pressure for Use by Others (psf) NA
Design Dead Loads:
Tank dead load, empty (k): 1.8
Propane specific weight (# /gal): 4.23
Tank volume (gal): 1000
Total tank dead load (k): 6.03
w
IIAIue-1
1
L —i
I
DIA.
TYPICAL PIPE BOLLARD
DETAIL
GONG. GROWN
6 "(P STD. PIPE
FILL w/ GONG.
COLOR A5 5EL.
A.G. PAVING
WHERE OCCURS)
GEMENT WASH
AT A.G. PAVING)
GONG. SLAB
WHERE OGCUR5)
i / /-
j
1000 gal. Propane Tank Anchorage
Roofline Supply
2010 CBC (2009 IBC) 4540 Easton Dr
Bakersfield CA
Contractor: Wholesale Fuels
All design not shown below is by others 6/16/2011
Sheet of
Project No. 18001
Scope of Work: These calculations are for the seismic anchorage of a Propane tank in Bakersfield CA
Earthquake Design Data:
Occupancy Category: II Latitude ( °): 35.3698 Ss (g): 1.153
Importance Factor: 1.00 Longitude ( °): - 119.0532 Sl (g): 0.415
Site Classification: D Basic SFRS: Tank, Unbraced Legs
Seismic Category: D Analysis Procedure: Equivalent Lateral Force (!Method
Seismic Response Coefficient, C5, Fp /Wp: 0.399 Design Base Shear, pQE (k): 2.41
Response Modification Factor, R, RP: 2.00
Wind Design Data:
Occupancy Category: 11 Basic Wind Speed, 3- Second Gust (mph): 85
Importance Factor: 1.00 Building Enclosure Classification: NA
Wind Exposure: C Internal Pressure Coefficient: NA
Exterior Components and Cladding Design Pressure for Use by Others (psf) NA
Design Dead Loads:
Tank dead load, empty (k): 1.8
Propane specific weight (# /gal): 4.23
Tank volume (gal): 1000
Total tank dead load (k): 6.03
Soil Design Characteristics Conservatively Assume 2/3 of 2010 CBC Table 1806.2 Class 5 Soil
Allowable vertical soil bearing pressure (psf): 1000
Allowable lateral soil bearing pressure (psf): 663
PROPOSED TANK PLAN
ENGEL & COMPANY
n
n iiaeers
4000 UNION AV9NUr-
5AKEKSFiEl.ra, CA 93305
661) 327.7025
El E1 I
NOTES:
Copies of all necessary test and inspection records shall be filed with b uilding official overseeing
the project, as well as the registered design professional in responsible charge of the project,
the engineer in charge of structural design and the soils engineer.
All test specimens shall be consistent with the materials, mrkmanship and details to be used
throughout this project,
The contractor responsible for overseeing the construction of the main lateral force resisting
systems on this project shall submit a written statement of responsibility to the building official
and the owner prior to the commencement of work on that particular system that shall contain
the following (per CBC 9706. 1)
9 Acknowtedgment of abvereness of the special requirements contained in the statement
of special inspections
2 Acknowledgment that control will be exercised to obtain conformance with the construction
documents approved by the building official
3 Procedures for exercising' control within the contractor's organization; the method and
frequency of reporting and the distribution of reports
4 Identification and qualifications of the person(s) exercising such control and their position(S)
in the organization.
It shall.be the responsibility of the contractor to read and understand the above inspection. requirements
and to coordinate the testing schedule with the appropriate testing agency:.
GENERAL NOTES
2010 CALIFORNIA BUILDING CODE GOVERNS DESIGN AND CONSTRUCTION
SCOPE OF WORK: THESE PLANS ARE FOR THE ANCHORAGE OF A NEW
PROPANE TANK IN BAKERSFIELD, CA. ALL WORK NOT SHOWN ON THESE
PLANS IS BY OTHERS.
SAFETY REGULATIONS — CALIF. ADMIN. CODE, TITLE 8, GENERAL SAFETY
ORDERS ( "CAL OSHA') IS APPLICABLE TO THE CONSTRUCTION OF THIS PROJECT
AND PROVISIONS THEREOF MUST BE FOLLOWED. ENGEL & COMPANY
ENGINEERS IS NOT RESPONSIBLE FOR THE MEANS AND METHODS OF
CONSTRUCTION, NOR FOR SAFETY ON THE JOBSITE. THESE RESPONSIBILITIES
ARE INTENDED TQ BE AND TO REMAIN SOLELY THOSE OF THE BUILDER.
ALL DIMENSIONS WHICH ARE DEPENDENT ON EXISTING CONDITIONS SHALL BE
FIELD VERIFIED PRIOR TO THE COMMENCEMENT OF CONSTRUCTION.
FOUNDATIONS ARE DESIGNED FOR A SOIL PRESSURE OF NOT MORE THAN 1000
PSF.
STRUCTURAL STEEL — ALL PLATES AND SHAPES SHALL CONFORM TO THE
REQUIREMENTS OF ASTM A36 OR ASTM A992. PIPE SHALL CONFORM TO THE
REQUIREMENTS OF ASTM A501. STRUCTURAL TUBING SHALL CONFORM TO THE
REQUIREMENTS OF ASTM A500, GRADE B. BOLTS SHALL BE ASTM A307
UNLESS THE PLANS SHOW OTHERWISE. BOLT HOLES BE 1/16" LARGER IN
DIAMETER THAN THE BOLT,
AUG 0 0 2011
STATEMENT OF SPECIAL INSPECTIONS
Testing, Agency: Date: 8/812011
Project Name: ROOFLINE SUPPLY Owner: ROOFLINE SUPPLY
Project Description: CONCRETE ANCHORAGE FOR, 1000 GAL, PROPANE TANK.
Project Location: 4540 EASTON DRIVE City: BAKERSFIELD, CA
R.D.Pi of Record: JOSEPH C. ENGEL Engel & Co. Job No., 18001
Architect:
Soils Report by: File No.: Date:
The special' inspector shall refer to the approved construction drawings, CBC 2010 Chapter 17 and the
documents referenced therein to verify the following selected items.:
STRUCTURAL STEEL (SEE CBC 2010 TABLE 1704.3)
Frequency of inspection; check all applicable conditions
Continuous Periodic
HIGH STRENGTH BOLTS: REMARKS
ID markings to conform to ASTM standards
MNs certificate of compliance
Bearing -type conditions
Slip - critical conditions
MATERIAL VERIFICATION:'
ID markings to conform to AWS standards
Mfr's certificate of compliance.
WELDING:
Complete & partial pen. groove welds
Multipass fillet welds
Single -pass Fillet welds ? s /rfi"
Single -pass Fillet welds < s /rr`
Floor and /or roof deck welds
Verify weldability of reinf steel other than ASTM A 706
Reinf. steel- resisting flexural and axial forces in
intermediate and special moment frames
Boundary elements of special reinf. conk. ,shear walls
and shear reinforcement
Shear reinforcement
Other reinforcing steel
STEEL. FRAME JOINTS:
Details such as bracing and stiffening
Member locations
Application of joint details at each connection-
MISC. ITEMS
Special inspection of all welding; bolting, screw
attachment and holdowns associated with .Shear
Walls constructed of cold- ioimed steel framing
Verify the erection and fastening of arch'I cladding
and veneers weighing more than 5 P5F
Verify the anchorage and installation of
suspended ceiling systems
ENSURE THE PROPER INSTALLATION OF ALL POST INSTALLED CONC: ANCHORS
El E1 I
NOTES:
Copies of all necessary test and inspection records shall be filed with b uilding official overseeing
the project, as well as the registered design professional in responsible charge of the project,
the engineer in charge of structural design and the soils engineer.
All test specimens shall be consistent with the materials, mrkmanship and details to be used
throughout this project,
The contractor responsible for overseeing the construction of the main lateral force resisting
systems on this project shall submit a written statement of responsibility to the building official
and the owner prior to the commencement of work on that particular system that shall contain
the following (per CBC 9706. 1)
9 Acknowtedgment of abvereness of the special requirements contained in the statement
of special inspections
2 Acknowledgment that control will be exercised to obtain conformance with the construction
documents approved by the building official
3 Procedures for exercising' control within the contractor's organization; the method and
frequency of reporting and the distribution of reports
4 Identification and qualifications of the person(s) exercising such control and their position(S)
in the organization.
It shall.be the responsibility of the contractor to read and understand the above inspection. requirements
and to coordinate the testing schedule with the appropriate testing agency:.
GENERAL NOTES
2010 CALIFORNIA BUILDING CODE GOVERNS DESIGN AND CONSTRUCTION
SCOPE OF WORK: THESE PLANS ARE FOR THE ANCHORAGE OF A NEW
PROPANE TANK IN BAKERSFIELD, CA. ALL WORK NOT SHOWN ON THESE
PLANS IS BY OTHERS.
SAFETY REGULATIONS — CALIF. ADMIN. CODE, TITLE 8, GENERAL SAFETY
ORDERS ( "CAL OSHA') IS APPLICABLE TO THE CONSTRUCTION OF THIS PROJECT
AND PROVISIONS THEREOF MUST BE FOLLOWED. ENGEL & COMPANY
ENGINEERS IS NOT RESPONSIBLE FOR THE MEANS AND METHODS OF
CONSTRUCTION, NOR FOR SAFETY ON THE JOBSITE. THESE RESPONSIBILITIES
ARE INTENDED TQ BE AND TO REMAIN SOLELY THOSE OF THE BUILDER.
ALL DIMENSIONS WHICH ARE DEPENDENT ON EXISTING CONDITIONS SHALL BE
FIELD VERIFIED PRIOR TO THE COMMENCEMENT OF CONSTRUCTION.
FOUNDATIONS ARE DESIGNED FOR A SOIL PRESSURE OF NOT MORE THAN 1000
PSF.
STRUCTURAL STEEL — ALL PLATES AND SHAPES SHALL CONFORM TO THE
REQUIREMENTS OF ASTM A36 OR ASTM A992. PIPE SHALL CONFORM TO THE
REQUIREMENTS OF ASTM A501. STRUCTURAL TUBING SHALL CONFORM TO THE
REQUIREMENTS OF ASTM A500, GRADE B. BOLTS SHALL BE ASTM A307
UNLESS THE PLANS SHOW OTHERWISE. BOLT HOLES BE 1/16" LARGER IN
DIAMETER THAN THE BOLT,
AUG 0 0 2011
BILLING & PERMIT STATEMENT BAKERSFIELD FIRE DEPARTMENT
M E R 9 F I L D Prevention Services
PERMIT # FIRE 2101 H StreetARrAr
41
S
Bakersfield, CA 93301
oh.,..e• GG1 _ 27G_70 . Gov- AA1 _f2C7_'7171
All permits must be reviewed, stamped, and approved PRIOR TO BEGINNING WORK.
Alarm - New & Modification (minimum charge) $280
Over 10,000 sq ft $0.028 x sq ft
Sprinkler - New & Modification (minimum charge) $280
Over 10,000 sq ft $0 .028 x sq ft
Sprinkler - Minor Modification ( <10 heads) $ 96 (inspection only) 84
Commercial Hood (New & UL 300 Upgrade Modification) $470
Additional Hood 58 hood _
Commercial Hood -Minor Modification (add /move nozzle) $ 96 (inspection only) 84
Spray Booth (New & Modification)
SITE INFORMATION
LOCATION OF PROJECT c PROPERTY OWNER
w
0 1
180 /tank
STARTING DATE COMPLETION DATE
S-
NAME
h15Lk - l l l K L
PROJE E
E
ADDRESS PH NE # [,LGiC7
PROJECT ADDRESS
40 ZASN•• l
crry g C ER S E L STATE CA ZIP CODE
CONTRACTOR INFORMATION
82
CONTRACTOR NA ' ` , CA LICENSE # TYP OF LICENSE EXPIRATION DATE PHONE #
CONTRACTOPjC0j4PANY NAME
AO
FAX #
ADDRESS' . • •
l l tea, W S
CITY ZIP CODE
All permits must be reviewed, stamped, and approved PRIOR TO BEGINNING WORK.
Alarm - New & Modification (minimum charge) $280
Over 10,000 sq ft $0.028 x sq ft
Sprinkler - New & Modification (minimum charge) $280
Over 10,000 sq ft $0 .028 x sq ft
Sprinkler - Minor Modification ( <10 heads) $ 96 (inspection only) 84
Commercial Hood (New & UL 300 Upgrade Modification) $470
Additional Hood 58 hood _
Commercial Hood -Minor Modification (add /move nozzle) $ 96 (inspection only) 84
Spray Booth (New & Modification) 470
98
Aboveground Storage Tank (1 inspection per installation) AST 180 /tank 82
Additional Tank ATI 96 /tank 82
Aboveground Storage Tank (Removal, Mod,or Inspect'n) ATR 109 /tank 82
Underground Storage Tank (Installation /Inspection) NI 878 /tank 82
Underground Storage Tank (Modification) MOD 878 /site 82
Underground Storage Tank (Minor Modification) MTM 167 /site 82
Underground Storage Tank (Removal) TR 573 /tank 84
Mandated UST Testing: Fuel Mont Cert/SB989 /Cath. Prot.
NOTE: $96 /hr for each type of test/per site /per UST system
even if scheduled at the same time
96 /hr (2 hrs minimum) _ $192 82
Oil well (Installation, Inspection, or re- inspection) X 96 /hr 82
Tent # 96 /tent 84
After -hours inspection fee 121 /hr (2 hrs minimum) = $242
Pyrotechnic (1 permit per event, plus an inspection fee of
96 /hr during business hours) PY
NOTE: After hours Pyrotechnic event inspection Is @ 121 /hr
96 /hr + (5 hrs min standby fee /insp) _ $576
5 hrs min standby fee Ins = 605
84
Re- inspection /Follow -up Inspection 96 /hr 84
Portable LPG (Propane): # of Cages? _ 96 /hr 84
Explosive Storage 266 84
Copying & File Research (File Research fee $50 /hr) 0.25 /page 84
Miscellaneous 1 84