HomeMy WebLinkAbout4600 STINE ROAD SB-989 2013HOODS ALARMS SPRINKLER SYSTEMS SFIRA B OUT H AST UST
Permit No. Permit No. Permit No. Permit No. Permit No. Permit No.
File Number: ZCQ &"7 Address: S-r -22-L
Bakersfield, CA 933
Date Received: 5?-- :? cr -- ! 3
Business Name: -2'V AT V' e a 6 u d-f •
SYSTEM: BUILDING SQUARE FEET: INSPECTION LOG
New Mod.
Commercial Hood System
Fire Alarm System
Fire Sprinkler System
Ingay Finish
Aboveground Storage Tank
Underground Storage Tank
minor
modification Underground Storage Tank
removal Underground Storage Tank
C Other.
Building Sq. Feet:
Calculation Bldg. Sq. Ft:
Comments:
9.
a.
3.
4.
Date Time
8 I/3 I .n
Signature
Signature
BILLING & PERMIT STATEMENT
PERMIT #
ly %
B l
OarPARIM MT
BAKERSFIELD FIRE DEPARTMENT
Prevention Services
2101 H Street
Bakersfield, CA 93301
Phnna• AA1 a Fax• hh1 -RS7 -7171
All permits must be reviewed, stamped, and approved PRIOR TO BEGINNING WORK.
PERMITTYPE FEE CALCULATION TOTAL
DUE
Alarm - New & Modification (minimum charge) $280
SITE INFORMATION
LOCATION OF PROJECT PROPERTY OWNER
Metro Gas & Mart Metro Gas & Mart
STARTING DATE NAME
8/30/13 9:00am Mike
PROJECT NAME ADDRESS PHONE #
Metro Gas & Maxi 4600^^ Stine Rd. 661- 831 -0836
PROJECT ADDRESS CITY D/'"C ICEF2.._S I E LD STATE C /4 ZIP CODE
4600 STine Rd. Bakersfield CA 93309 93309
CONTRACTOR INFORMATION
96 (inspection only)
CONTRACTOR NAME CA LICENSE # TYPE OF LICENSE EXPIRATION DATE PHONE #
Frank Landa 804904 A C61 D4013/3 J 14 661 -631 -3870
CONTRACTOR COMPANY NAME FAX #
Confidence UST Services Inc. 661- 587 -9758
ADDRESS CITY ZIP CODE
16250 Meacham Road lBakerafield93314
All permits must be reviewed, stamped, and approved PRIOR TO BEGINNING WORK.
PERMITTYPE FEE CALCULATION TOTAL
DUE
Alarm - New & Modification (minimum charge) $280
ONLY
TREASURY
ACCT NO
Over 10,000 sq ft 0 .028 x sq ft
Sprinkler - New & Modification (minimum charge) 280
Over 10,000 sq ft 0 .028 x sq ft
Sprinkler - Minor Modification ( <10 heads) 96 (inspection only) 84
Commercial Hood (New & UL 300 Upgrade Modification)
Additional Hood
470
58 hood
Commercial Hood - Minor Modification (add /move nozzle) 96 (inspection only) 84
Spray Booth (New & Modification) 470
98
Aboveground Storage Tank (1 inspection per installation) AST 180 /tank 82
Additional Tank ATI 96 /tank 82
Aboveground Storage Tank (Removal, Mod,or Inspect'n) ATR 109 /tank 82
Underground Storage Tank (Installation /Inspection) NI 878 /tank 82
Underground Storage Tank (Modification) MOD 878 /site 82
Underground Storage Tank (Minor Modification) MTM 167 /site 82
Underground Storage Tank (Removal) TR 573 /tank 84
Mandated UST Testing: Fuel Mont Cert /SB989 /Cath. Prot.
NOTE: $96 /hr for each type of test/per site /per UST system
even if scheduled at the same time
96 /hr (2 hrs minimum) _ $192 82
Oil well (Installation, Inspection, or re- inspection) X 96 /hr 82
Tent # 96 /tent 84
After -hours inspection fee 121 /hr (2 hrs minimum) = $242
Pyrotechnic (1 permit per event, plus an inspection fee of
96 /hr during business hours) Py
NOTE: After hours Pyrotechnic event inspection is @ $121 /hr
96 /hr + (5 hrs min standby fee /insp) _ $576
5 hrs min standby fee /ins = $605
84
Re- inspection /Follow -up Inspection 96 /hr 84
Portable LPG (Propane): # of Cages? _ 96 /hr 84
Explosive Storage 266 84
Copying & File Research (File Research fee $50 /hr) 0.25 /page 84
Miscellaneous 84
FD2021 (Ray 05/11)
UNDERGROUND STORAGE TANKS
APPLICATION
TO PERFORM ELD /LINE TESTING/
SB989 SECONDARY CONTAINMENT
TESTING /TANK TIGHTNESS TEST AND
FUEL MONITORING CERTIFICATION
Please note that these are separate
individual tests and will be charged per
separate type test accordingly.)
PERMIT #
ENHANCED LEAK DETECTION
TANK TIGHTNESS
AR1N T
BAKERSFIELD FIRE DEPARTMENT
Prevention Services
2101 H Street
Bakersfield, CA 93301
Phone: 661 - 326 -3979 • Fax: 661 - 852 -2171
Page 1 of 1
LINE TESTING ® SB -989 SECONDARY CONTAINMENT
FUEL MONITORING CERTIFICATION
SITE INFORMATION
FACILITY
Matreo Gas & Mart
NAME & PHONE # OF CONTACT PERSON
Mike (661) 831 -0836
ADDRESS
4600 Stine Rd. , Bakersfield CA 93309
OWNER NAME
Metro Gas & Mart
OPERATOR NAME PERMIT TO OPERATE #
OF TANKS TO BE TESTED: IS PIPING GOING TO BE TESTED? YES NO
TANK # VOLUME CONTENTS
TANK TESTING COMPANY
TESTING COMPANY
Confidence UST Services Inc.
NAME & PHONE # OF CONTACT PERSON
Karli Karns (661) 631 -3870
MAILING ADDRESS
16250 Meacham Road Bakersfield CA 93314
NAME & PHONE # OF TESTER OR SPECIAL INSPECTOR
Frank T-a.nda (661) 20c;-c;944
CERTIFICATION #
486853 703
DATE & TIME TEST TO BE CONDUCTED
8/30/13
ICC #
8058524 -U1
TEST METHOD
APPLICANT SIG TURE DATE
THIS APPLICATION BECOMES A PERMIT WHEN APPROVED
APP VED BY DATE
FD2095 (Rev 03/08)
BAKERSFIELD CITY FIRE DEPARTMENT — INSPECTION RECORD
Post this Card at the Job Site and DO NOT Remove for Duration of Work
Inspection Request Phone No: (661) 326 -3979
UST NEW INSTALL
DESCRIPTION DATE SIGNATURE
BACKFILL
PRIMARY PIPE
SECONDARY PIPE
SECONDARY CONTAINMENT
SENSORS a
AUTHORIZATION FOR FUEL
ELECTRICAL SEAK -OFF
TANK - TESTING -- . -- A
UST REMOVAL
DESCRIPTION DATE SIGNATURE
AST NEW INSTALL
DESCRIPTION DATE SIGNATURE
MODIFICATIONS MINOR / MAJOR
AST REMOVAL
DESCRIPTION DATE SIGNATURE
EVR UPGRADE
PRIOR-TO- OPERATION -OF ANY SYSTEM,
ALL_USTANb %OR_AST_SYSTEMS_SHALL BE
INSTALL,.COMPLETE AND ACCEPTED'BY
MISC. ACTIVITY I THE SAKERSFIELD CITY FIRE DEPARTMENT.
r,-FIRE-DEPARTMENT (FINAL)
REMARKS:
BUILDING ADDRESS:
JOB DESCRIPTION: 6- OCCUPANCY TYPE: 23
OWNER: .rirea < 6 - P 1yi4r PERMIT NO. -1660C qZG
CONTRACTOR: a PHONE # i-- Q
FD 1743
MONITORING SYSTEM CERTIFICATION
For Use By All Jurisdictions Within the State ofCalifornia
Authority Cited: Chapter 6 7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code ofRegulations
This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be
prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided
to the tank system owner /operator. The owner /operator must submit a copy of this form to the local agency regulating UST systems
within 30 days of this date.
A. General Information
Facility Name: Metro Station Bldg. No.:
Site Address: 4600 Stine Road City: Bakersfield zip: 93309
Facility Contact Person: Sam Bassem
Make /Model of Monitoring System: Veeder -Root TLS 350
B. Inventory of Equipment Tested /Certified
Check the appropriate boxes to Indicate specific equipment inspected/serviced:
Contact Phone No.: 661 -496 -0838
Date of Testing/Servicing: 3/25/2013
Tank ID: 12000 gal. Regular 1 Tank ID: 12000 gal. Regular 2
In -Tank Gauging Probe. Model: 847390-107 Lx] In -Tank Gauging Probe. Model: 847390 -107
Lx] Annular Space or Vault Probe. Model: 794390-420 U Annular Space or Vault Sensor. Model: 794390 -420
U Piping Sump / Trench Sensor(s). Model: 794380-208 U Piping Sump / Trench Sensor(s). Model: 794380 -208
Fill Sump Sensor(s) Model: Fill Sump Sensor(s). Model:
U Mechanical Line Leak Detector. Mode I:FXiV U Mechanical Line Leak Detector. Model: FX1V
Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model:
Tank Overfill / High Level Sensor. Model: 847390 -107 U Tank Overfill / High Leval Sensor. Model: 847390 -107
Other (specify equip. type and model in Sec. E on Pg. 2) Other (specify equip. type and model in Sec. E on Pg. 2)
Tank ID: 12000 gal. Super Tank ID: 12000 gal. Diesel
x] In -Tank Gauging Probe. Model:847390 -107 Lx] In -Tank Gauging Probe. Model: 847390 -107
Lx] Annular Space or Vault Sensor. Model:794390 -420 x] Annular Space or Vault Sensor. Model: 794390 -420
U Piping Sump / Trench Sensor(s). Modcl:794380 -208 L Piping Swap / Trench Sensor(s). Model: 794380 -208
Fill Sump Sensors(s). Model: Fill Sump Sensor(s). Model:
n Mechanical Line Leak Detector. Model:FX1V Lx] Mechanical Line Leak Detector. Model: FX1DV
Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model:
U Tank Overfill / High Level Sensor. Model: 847390-107 Lx] Tank Overfill / High Level Sensor. Model. 847390 -107
Other (specify equip. type and model in Sec. E on Pg. 2) Other (specify equip. typs and model in Sec. E on Pg. 2)
Dispenser ID: 1 - 2 Dispenser ID: 3-4
Dispenser Containment Sensor(s). Model: 794380 -208 U Dispenser Containment Sensor(s). Model: 794380 -208
n Shear Valve(s). X] Shear Valve(s).
Dispenser Containment Float(s) and Chain(s). Dispenser Containment Float(s) and Chain(s)
Dispenser ID: 5 - 6 Dispenser ID: 7 - 8
xU Dispenser Containment Sensor(s). Model: 794380 - 208 U Dispenser Containment Sensor(s). Model: 794380 -208
Lx] Shear Valve(s). U Shear Valve(s).
Dispenser Containment Float(s) and Chains(s). Dispenser Containment Float(s) and Chain(s).
Dispenser ID: 9-10 Dispenser ID:
U Dispenser Containment Sensor(s). Model: 794380 -208 Dispenser Containment Sensor(s). Model:
Shear Valve(s). Shear Valve(s).
Dispenser Containment Float(s) and Chain(s) Dispenser Containment Float(s) and Chain(s).
If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility.
C. Certification -I certify that the equipment identified in this document was inspected /seryices in accordance with the
manufacturers' guidlines. Attached to this Certification is information (e.g. manufacturers' checklist) necessary to verify that
this information is correct and a plot plan showing the layout of monitoring equipment. For equipment capable of generating
such reports, I have attached a copy of the report; (check all that apply) x System S t -up x Alarm history report
Technician Name (print): Bradley Seykora Signature: _
Certification No: 840738 License No: 804904
Testing Company Name: Confidence UST Services, Inc. Phone No: 800 - 339 -9930
Site Address: 4600 Stine Road, Bakersfield CA 93309 Date of Testing/Servicing: 3/25/2013
D. Results of Testing /Servicing
Software Version Installed: 331.00
Complete the following checklist:
x] Yes No* Is the audible alarm operational?
x Yes I No* Is the Visual alarm operational?
x Yes No* Were all sensors visually inspected, functionally tested, and confirmed operational?
x I Yes No* Were all sensors installed at the lowest point of secondary containment and positioned so that other
equipment will not interfere with their proper operation?
Yes No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) Hx N/A operational?
x Yes No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary
N/A containment monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes:
which sensors initate positive shut - down? E Sump /Trench Sensors Dispenser Containment Sensors
Did you confirm positive shut -down due to leaks and sensor failure /disconnected? [X] Yes; No;
Yes No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no
N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visual and audible at
the tank fill point(s) and operating properly? If so, at what percent oftank capasity does the alarm
trigger? 9p %
Yes* U No Was any monitoring equipment replaced? if Yes, identify specific sensors, probes, or other equipment
replaced and list the manufacturer name and model for all replacement parts in Section E, below.
Yes* Lx] No Was liquid found inside any secondary containment systems designed as dry systems?
Product; Water. If yes, describe causes in Section E, below.
x Was monitoring system set -up reviewed to ensure proper settings? Attach set -up reports, if applicable.
x Yes No* I Is all monitoring equipment operational per manufacturer's specifications?
In Section E below, discribe how and when these deficiencies were or will be corrected.
E. Comments:
F. In -Tank Guaging / SIR Equipment: [X] Check this box if tank guaging is used only for inventory control.
Check this box if tank guaging or SIR equipment is installed.
This section must be completed if in -tank guaging equipment is used to perform leak detection monitoring.
Complete the following checklist:
Lx Yes No* Has all input wiring been inspected for proper enter and termination, including testing for ground faults?
x Yes No* Were all tank guaging probes visually inspected for damage and residue buildup?
x Yes No* Was accuracy of system product level readings tested?
x Yes No* Was accuracy of system water level readings tested?
x Yes 7 No* Were all probes reinstalled properly?
Lx] Yes No* I Were all items on the equipment manufacturer's maintenance checklist completed?
In the Section H, below, describe how and when these deficiencies were or will be corrected.
G. Line Leak Detectors (LLD): Check this box if LLD's are not installed.
Complete the following checklist:
Lx] Yes No* For equip. start -up or annual equipment certification, was a leak simulated to varify LLD performance?
Check all that apply) Simulated leak rate: E3 g.p.h.: 0.1 g.p.h.; 0.2 g.p.h.;
x Yes No* Were all LLD's confirmed operational and accurate within regulatory requirments?
Was the testing apparatus properly calibrated?
No For mac anical LLD's, does the LLD restrict product flow i it detects a leak?
qYeNo*
N/A
No* For electronic LLD's, does the turbine automatically shut off ifthe LLD detects a leak?
N/A
Yes No* For electronic LLD's, does the turbine automatically shut off if any portion of the monitoring system is
x] N/A disabled or disconnected?
Yes No* For electronic LLD's, does the turbine automatically shut off if any portion ofthe monitoring system
rx] N/A malfunction or fails a test?
Yes No* For electronic LLD's, have all accessible wiring connections been visually inspected?
x] N/A
x Yes No I Were all items on the equipment manufacturer's maintenance checklist completed?
In the section H, below, describe how and when these deficiencies were or will be corrected.
H. Comments:
METRO STATION
4600 STINE ROAD SOFTWARE REVIS WN LEVEL
BAK,EkSFIELD. CA VERSION 331.00
SOFTWARE# 346331 -100 -A
CREATED - 11.02.10.12.31
MAR 25. 2013 12:43 PM
S- MODULE# 330160 -004 -a
SYSTEM FEATURES:
PERIODIC IN -TANK TEST
SYSTEM STATUS REPORT ANNUAL III -TANK TESTS
I SD /APM
ALL FUNCTIONS NORMAL
INVENTORY REPORT
T (:REGULAR 1
VOLUME = 3487 GALS
ULLAGE e 8513 GALS
90% ULLAGE= 7313 GALS
TC VOLUME - 3467 GALS
HEIGHT - 32.07 INCHES SYSTEM SETUP
WATER VOL = 0GALS - - - - - - - - - - - -
WATER = 0.00 INCHES MAR 25, 2013 12:43 PM
TEMP - 67.4 DEG F
T 2:REGULAR 2
GALS
SYSTEPI UNITS
VOLUME = 3491 GALS U.S.
ULLAGE = 8509 GALS SYSTE°I LANGUAGE
90% ULLAGE= 7309 GALS ENGLISH
TC VOLUME - 3471 GALS SYSTEM DATE /TIME FORMAT
HEIGHT - 32.09 INCHES MON DD YYYY HH:MM:SS xM
WATER VOL 0 GALS
DISABLED
WATER o 0.00 INCHES METRO STATION
TEMP m 67.1 DEG F 4600 STINE ROAD
T 4:DIESEL
BAKERSFIELD, CA
T 3:SUPER
VOLUME = 2205 GALS SHIFT TIME 1 DISABLED
ULLAGE = 9795 GALS SHIFT TIME 2 DISABLED
90% ULLAGE- 8595 GALS SHIFT TIME 3 DISABLEDTCVOLUME - 2186'GALS SHIFT TIME 4 DISABLED
HEIGHT - 23.09 INCHES
WATER VOL = 18 GALS TANK PER TST NEEDED WRNWATER = 0.89 INCHES DISABLED
TEMP - 71.3 DEG F TANK. ANN TST NEEDED WRN
DISABLED
T 4:DIESEL LINE RE- ENABLE METHOD
VOLUME = 2224 GALS PASS LINE TEST
ULLAGE = 9776 GALS
90% ULLAGE= 8576 GALS LINE PER TST NEEDED WRN
TC VOLUME - 2215 GALS DISABLED
HEIGHT = 23.23 INCHES LINE ANN TST NEEDED WRN
WATER VOL = 20 GALS DISABLED
WATER = 0.97 INCHES
TEMP - 68.5 DEG F PRINT TC VOLUMES
ENABLED
MANIFOLDED TANKS TEMP COMPENSATION
INVENTORY TOTALS VALUE (DEG F ): 60.0
T (:REGULAR 1 STICK HEIGHT OFFSET
T 2:REGULAR 2 DISABLED
VOLUME - 6978 GALS ULLAGE: 90%
TC VOLUME = 6938 GALS
A x x x x END x x x x x
vL LI--11 H r VKITH 1
HEIGHT
DAYLIGHT SAVING TIME
DISABLED
RE- DIRECT LOCAL PRINTOUT
DISABLED
EURO PROTOCOL PREFIX
S
SYSTEM SECURITY
CODE : 000000
MAINTENANCE HISTORY
DISABLED
TANK CHART SECURITY
DISABLED
CUSTOM ALARMS
DISABLED
SERVICE NOTICE
DISABLED
ISO 3166 COUNTRY
CODE:
VAPOR MONITORING TYPE
CARB ISD
MASS/DENSITY
DISABLED
I
COMMUNICATIONS SETUP IN—TANK SETUP T 2:REGULAR 2
PRODUCT CODE 2
THERMAL COEFF :.000750
T 1:REGULAR 1 TANK DIAMETER 96.50
PORT SETTINGS: PRODUCT CODE I TANK PROFILE 1 PT
THERMAL 0 FULL VOL 12000
COMM BOARD : 1 (ED1M ) TANK DIAMETER 96.50
RS -232 SECURITY TANK PROFILE 1 PT
CODE : DISABLED FULL VOL 12000 FLOAT SIZE: 4.0 IN.
COMM BOARD 2 (RS -232) WATER WARNING 2.0
BAUD RATE 9600 FLOAT SIZE: 4.0 IN. HIGH WATER LIMIT: 3.0
PARITY NONE WATER ALARM FILTER: LOW
STOP BIT I STOP
DATA LENGTH:
WATER WARNING : 1.5
HIGH WATER LIMIT: 3.0 MAX OR LABEL VOL: 1200138DATA
RS -232 SECURITY WATER ALARM FILTER: LOW OVERFILL LIMIT 90%
CODE DISABLED 10800
MAX OR LABEL VOL: 12000 HIGH PRODUCT
COMM BOARD 3 (RS -232) OVERFILL LIMIT 9G`o
10800 DELIVERY LIMIT
11400
15% BAUD RATE 1200
PARITY NONE HIGH PRODUCT 95Y. 1800
STOP BIT 1 STOP
DATA LENGTH: 8 DATA
11400
DELIVERY LIMIT 15 LOW PRODUCT 400
RS -232 SECURITY 1800 LEAK ALARM LIMIT:
CODE DISABLEU 99
LOW PRODUCT : 400 TANK TILT 0.00
LEAK ALARM LIMIT: 99 PROBE OFFSET 0.00
AUTO TRANSMIT SETTINGS: SUDDEN LOSS LIMIT:
TANK TILT 0.00
AUTO LEAK ALARM LIMIT PROBE OFFSET 0.00 SIPHON MANIFOLDED TANKS
DISABLED TO: NONE
AUTO HIGH WATER LIMIT LINE MANIFOLDED TANKS
DISABLED SIPHON MANIFOLDED TANKS TO: 01
AUTO OVERFILL LIMIT TO: NONE
DISABLED LINE MANIFOLDED TANKS LEAK MIN PERIODIC: O:oAUTOLOWPRODUCTTO020DISABLED
AUTO THEFT LIMIT
DISABLED LEAK MIN PERIODIC: 0% LEAK MIN ANNUAL 0%
AUTO DELIVERY START 0 0
DISABLED
AUTO DELIVERY END LEAK MIN ANNUAL 0%
0 PERIODIC_. TEST TYPEDISABLEDSTANDARDAUTOEXTERNALINPUTON
DISABLED
AUTO EXTERNAL INPUT OFF PERIODIC TEST TYPE ANNUAL TEST FAIL
DISABLED STANDARD ALARM DISABLED
AUTO SENSOR FUEL ALARM
DISABLED ANNUAL TEST FAIL PERIODIC TEST FAIL
AUTO SENSOR WATER ALARM ALARM DISABLED ALARM DISABLED
DISABLED
AUTO SENSOR OUT ALARM PERIODIC TEST FAIL GROSS TEST FAIL
DISABLED ALARM DISABLED ALARM DISABLED
GROSS TEST FAIL ANN TEST AVERAGING: OFF
ALARM DISABLED PER TEST AVERAGING: OFF
ANN TEST AVERAGING: OFF TANK TEST NOTIFY: OFF
PER TEST AVERAGING: OFF
TNK TST SIPHON BREAK:OFF
TANK TEST NOTIFY: OFF
DELIVERY DELAY 5 MINRS -232 END OF MESSAGE
DISABLED TNK TST SIPHON BREAK :OFF PUMP THRESHOLD 10.00 d
DELIVERY DELAY 5 MIN
PUMP THRESHOLD : 10.00:
r
T 3:SUPER
PRODUCT CODE 3
THERMAL COEFF :.000750
TANK DIAMETER 96.50
TANK PROFILE 1 PT
FULL VOL 12000
FLOAT SIZE: 4.0 IN.
WATER WARNING 1.5
HIGH WATER LIMIT: 2.0
WATER ALARM FILTER: LOW
MAX OR LABEL VOL: 12000
OVERFILL LIMIT 90%
10800
HIGH PRODUCT 95%
11400
DELIVERY LIMIT 15%
1800
LOW PRODUCT 400
LEAK ALARM LIMIT: 99
SUDDEN LOSS LIMIT: 99
TANK TILT 0.00
PROBE OFFSET 0.00
SIPHON MANIFOLDED TANKS
TO: NONE
LINE MANIFOLDED TANKS
TO: N014E
LEAK MIN PERIODIC: Or
0
LEAK MIN ANNUAL 0v5
0
PERIODIC TEST TYPE
STANDARD
ANNUAL TEST FAIL
ALARM DISABLED
PERIODIC TEST FAIL
ALARM DISABLED
GROSS TEST FAIL
ALARM DISABLED
ANN TEST AVERAGING: OFF
PER TEST AVERAGING: OFF
TANK TEST NOTIFY: OFF
TNK TST SIPHON BREAK:OFF
DELIVERY DELAY 5 MIN
PUMP THRESHOLD 10.00%
T 4:DIEBEL
PRODUCT CODE 4
THERMAL COEFF 000450
TANK DIAMETER 96.50
TANK PROFILE 1 PT
FULL VOL 12000
FLOAT SIZE: 4.0 IN.
WATER WARNING 2.0
HIGH WATER LIMIT: 3.0
WATER ALARM FILTER: LOW
MAX OR LABEL VOL: 12000
OVERFILL LIMIT 901/4
10800
HIGH PRODUCT 95%
11400
DELIVERY LIMIT 15%
1800
LOW PRODUCT 400
LEAK ALARM LIMIT: 99
SUDDEN LOSS LIMIT: 99
TANK TILT 0.00
PROBE OFFSET 0.00
SIPHON MANIFOLDED TANKS
TO: NONE
LINE MANIFOLDED TANKS
TO: NONE
LEAK MIN PERIODIC:: 0%
0
PERIODIC TEST TYPE
STANDARD
PERIODIC TEST FAIL
ALARM DISABLED
GROSS TEST FAIL
ALARM DISABLED
PER TEST AVERAGING: OFF
TANK TEST NOTIFY: OFF
TNK TST SIPHON BREAK:OFF
DELIVERY DELAY 5 MIN
PUMP THRESHOLD 10.00%
LEAK TEST METHOD
TEST ON DATE : ALL TANK
FEB 10, 2011
START TIME : DISABLED
TEST RATE :0.20 GAL /HR
DURATION : 2 HOURS
TST EARLY STOP:DISABLED
LEAK TEST REPORT FORMAT
NORMAL
LIQUID SENSOR SETUP
L I:DISP 1 -2
TRI -STATE (SINGLE FLOAT)
CATEGORY : DISPENSER PAN
L 2:DISP 3 -4
TRI -STATE (SINGLE FLOAT)
CATEGORY : DISPENSER PAN
L 3:DISP 5 -6
TRI -STATE (SINGLE FLOAT)
CATEGORY : DISPENSER PAN
L 4:DISP 7 -8
TRI -STATE (SINGLE FLOAT)
CATEGORY : DISPENSER PAN
L S:DISP 9 -10
TRI -STATE (SINGLE FLOAT)
CATEGORY : DISPENSER PAN
L 9:REGULAR 1 STP
TRI -STATE (SINGLE FLOAT)
CATEGORY : STP SUMP
L10:REGULAR I ANN
TRI -STATE (SINGLE FLOAT)
CATEGORY : ANNULAR SPACE
L11:REGULAR 2 STP
TRI -STATE (SINGLE FLOAT)
CATEGORY : STP SUMP
L12 :REGULAR 2 ANN
TRI -STATE (SINGLE FLOAT)
CATEGORY : ANNULAR SPACE
L13:SUPER STP
TRI -STATE (SINGLE FLOAT)
CATEGORY : STP SUMP
L14:SUPER ANN
TRI -STATE (SINGLE FLOAT)
CATEGORY : ANNULAR SPACE
LI5:DIESEL STP
TRI -STATE (SINGLE FLOAT)
CATEGORY : STP SUMP
L16:DIESEL ANN
TRI -STATE (SINGLE FLOAT)
CATEGORY : ANNULAR SPACE
R 2:REGULAR 2 R 3:SUPER
PUMP SENSOR SETUP TYPE: TYPE:
PUMP CONTROL OUTPUT STANDARD
TANK 0: 2 NORMALLY CLOSED
S I:REGULAR 1
TA14K 0: 1
DISPENSE MODE:
MANIFOLDED: ALTERNATE
S 2:REGULAR 2
TANK 0: 2
DISPENSE MODE:
MANIFOLDED: ALTERNATE
OUTPUT RELAY SETUP
R I:REGULAR I
TYPE:
PUMP CONTROL OUTPUT
TANK p: 1
IN —TANK ALARMS
T 1:HIGH WATER ALARM
T 1:LOW PRODUCT ALARM
LIQUID SENSOR ALMS
L 2:FUEL ALARM
L 3 :FUEL ALARM
L 4 :FUEL ALARM
L 5:FUEL ALARM
L 9:FUEL ALARM
L11:FUEL ALARM
L 2:SENSOR OUT ALARM
L 3:SENSOR OUT ALARM
L 4:SENSOR OUT ALARM
L 5:SENSOR OUT ALARM
L 9:SENSOR OUT ALARM
L11:SENSOR OUT ALARM
L 2:SHORT ALARM
L 3:SHORT ALARM
L 4:SHORT ALARM
L 5:SHORT ALARM
L 9:SHORT ALARM
L11:SHORT ALARM
ISD SITE ALARMS
ISD GROSS PRES FAIL
ISD DEGRD PRES FAIL
ISD VAPOR LEAK FAIL
ISD VP PRES FAIL
ISD VP STATUS FAIL
ISD SETUP FAIL
ISD SENSOR OUT FAIL
PC —ISD FAILURE
ISD HOSE ALARMS
ALL:GROSS COLLECT FAIL
ALL:DEGRD COLLECT FAIL
ALL:FLOW COLLECT FAIL
IN —TANK ALARMS
T 2:HIGH WATER ALARM
T 2:LOW PRODUCT ALARM
LIQUID SENSOR ALMS
L 2:FUEL ALARM
L 3:FUEL ALARM
L 4:FUEL ALARM
L 5:FUEL ALARM
L 9:FUEL ALARM
LII:FUEL ALARM
L 2:SENSOR OUT ALARM
L 3:SENSOR OUT ALARM
L•4:SENSOR OUT ALARM
L 5:SENSOR OUT ALARM
L 9:SENSOR OUT ALARM
LII:SENSOR OUT ALARM
L 2:SHORT ALARM
L 3:SHORT ALARM
L 4:SHORT ALARM
L 5:SHORT ALARM
L 9:SHORT ALARM
LII:SHORT ALARM
ISD SITE ALARMS
ISD GROSS PRES FAIL
ISD DEGRD PRES FAIL
ISD VAPOR LEAK FAIL
ISD VP PRES FAIL
ISD VP STATUS FAIL
ISD SETUP FAIL
ISD SENSOR OUT FAIL
PC —ISD FAILURE
ISD HOSE ALARMS
ALL:GROSS COLLECT FAIL
ALL:DEGRD COLLECT FAIL
ALL:FLOW COLLECT FAIL
TANK a: 3
IN —TANK ALARMS
T 3 :HIGH WATER ALARM
T 3:LOW PRODUCT ALARM
LIQUID SENSOR ALMS
L 2:FUEL ALARM
L 3:FUEL ALARM
L 4:FUEL ALARM
L 5:FUEL ALARM
L13:FUEL ALARM
L 2:SENSOR OUT ALARM
L 3:SENSOR OUT ALARM
L 4:SENSOR OUT ALARM
L 5:SENSOR OUT ALARM
L13:SENSOR OUT ALARM
L 2:SHORT ALARM
L 3:SHORT ALARM
L 4:SHORT ALARM
L 5:SHORT ALARM
L13:SHORT ALARM
ISD SITE ALARMS
ISD GROSS PRES FAIL
ISD DEGRD PRES FAIL
ISD VAPOR LEAK FAIL
ISD VP PRES FAIL
ISD VP STATUS FAIL
ISD SETUP FAIL
ISD SENSOR OUT FAIL
PC —ISD FAILURE
ISD HOSE ALARMS
ALL:GROSS COLLECT FAIL
ALL:DEGRD COLLECT FAIL
ALL:FLOW COLLECT FAIL
R 4:DIESEL
TYPE:
STANDARD
1ORMALLY CLOSED
TANK is : 4
IN —TANK ALARMS
T 4:HIGH WATER ALARM
T 4:LOW PRODUCT ALARM
LIQUID SENSOR ALMS
L 1:FUEL ALARM
L 2 :FUEL ALARM
L 3:FUEL ALARM
L15:FUEL ALARM
L 1:SENSOR OUT ALARM
L 2:SENSOR OUT ALARM
L 3:SENSOR OUT ALARM
L15:SENSOR OUT ALARM
L 1 :SHORT ALARM
L 2:SHORT ALARM
L 3:SHORT ALARM
L15:SHORT ALARM
R 5:OVERFILL ALARM
TYPE:
STANDARD
NORMALLY OPEN
TANK 0: NONE
IN —TANK ALARMS
ALL:OVERFILL ALARM
ALL :HIGH PRODUCT ALARM
SMARTSENSOR SETUP
s 2:FM 3 -4
CATEGORY AIRFLOW METER
s 3:FM 5 -6
CATEGORY AIR FLOW METER
s 4:FM 7 -8
CATEGORY AIR FLOW METER
s 5:FM 9 -10
CATEGORY AIR FLOW METER
s 6:VP PRESSURE SEN.
CATEGORY VAPOR PRESSURE
s 7:CANISTER
CATEGORY VAPOR VALVE
S 8:ATM P SENSOR
CATEGORY ATM P SENSOR
EVR /ISD SETUP
EVR TYPE: BALANCE
BALANCE NOZZLE TYPE
VST
VAPOR PROCESSOR TYPE
VEEDER -ROOT POLISHER
ANALYSIS TIMES
TIME: 11:59 PM
DELAY MINUTES: I
ACCEPT HIGH ORVR:
ENABLED
ISD HOSE TABLE
ID FP FL HL AA RR
01 03 03 02 01 03
02 04 04 02 01 03
03 05 05 02 02 03
04 06 06 02 02 03
05 07 07 02 03 03
06 08 08 02 03 03
07 09 09 02 04 03
08 16 10 02 04 03
ISD AIRFLOW METER MAP
ID SERIAL NUM LABEL
1 40348 FM 3 -4
2 40070 FM 5 -6
3 40350 FM 7 -8
4 40356 FM 9 -10
ISD FUEL GRADE HOSE MAP
1 2 3 4
FP MHH MHH MHH MHH AA
01 1 0 0 0 U U U U 0
02 2 0 0 0 U U U U 0
03 201 101 901 3 U 1
04 202 102 902 3 U 1
05 203 103 903 3 U 2
06 204 104 904 3 U 2
07 105 905 205 U U 3
08 206 106 906 U U 3
09 207 107 907 U U 4
16 208 108 908 U U 4
LABEL TABLE
1: UNASSIGNED
2: BLEND3
3: REGULAR
4: MID GRADE
5: PREMIUM
6: GOLD
7: BRONZE
8: SILVER
9: BLEND2
10: BLEND4
PMC SETUP
PMC VERSION: 01.04
VAPOR PROCESSOR TYPE
VEEDER -ROOT POLISHER
ALARM HISTORY REPORT
SENSOR ALARM - - --
L I:DISP 1 -2
DISPENSER PAN
SETUP DATA WARNING
APR 17, 2012 11:56 AM
A x A x* END x x x x x
ALARM HISTORY REPORT
SENSOR ALARM - - - --
L 2:DISP 3 -4
DISPENSER PAN
SETUP DATA WARNING
APR 17, 2012 11:56 AM
A x x x x END x x x x x
ALARM HISTORY REPORT
ALARM HISTORY REPORT
SE14SOR ALARM - - - --
L 3:D1SP 5 -6 - - - -- SENSOR ALARM - - - --
DISPENSER PAN L 9:REGULAR 1 STP ALARM HISTORY REPORT
SETUP DATA WARNING STP SUMP
APR 17, 2012 11:56 AM SETUP DATA WARNING ----- SENSOR ALARM - - - --
APR 17, 2012 11:56 AM L12:REGULAR 2 ANN
ANNULAR SPACE
SETUP DATA WARNING
APR 17, 2012 11 :56 AM
x x x* x END x* x x x
x x x x END * x x x x
x** x x END x x x x x
ALARM HISTORY REPORT
ALARM HISTORY REPORT
SENSOR ALARM - - - --
L 4:DISP 7 -6 - - - -- SENSOR ALARM - - - --
ALARM HISTORY REPORTDISPENSERPANL10:REGULAR 1 ANN
SETUP DATA WARNING:: ANNULAR SPACE
APR 17. 2012 11:56 AM SETUP DATA WARNING -- --- SENSOR ALARM - - - --
APR 17. 2012 11:56 AM L13:SUPER STP
STP SUMP
SETUP DATA WARNING
APR 17. 2012 11:56 AM
x ** x END x* x x x
x x x x* END * x x x x
x x** END x x x x x
ALARM HISTORY REPORT
ALARM HISTORY REPORT
SENSOR ALARM - - - --
L 5:DISP 9 -10 - - - -- SENSOR ALARM - - - --
DISPENSER PAN LII:REGULAR 2 STP ALARM HISTORY REPORT
SETUP DATA WARNING STP SUMP
APR 17, 2012 11:56 AM SETUP DATA WARNING ----- SENSOR ALARM - - - --
APR 17. 2012 11:56 AM L14:SUPER ANN
ANNULAR SPACE
SETUP DATA WARNING
APR 17, 2012 11:56 All
x x x x x END * x x**
x* x x END * x x x*
x* END x* x x x
ALARM HISTORY REPORT
SENSOR ALARM -----
L15-DIESEL STP
STP SUMP
FUEL ALARM
MAR B. 2013 11:42 PM
FUEL ALARM
MAR 8, 2013 10:13 PM
FUEL ALARM
MAR 8. 2013 9:58 AM
0 x x ie x END x K x x x
ALARM HISTORY REPORT
SENSOR ALARM
L16:DIESEL ANN
ANNULAR SPACE
SETUP DATA WARNING
APR l7. 2012 11:56 AM
x x x x* END s x x x x
SENSOR ALARM - - - --
L15:DIESEL STP
STP SUMP
FUEL ALARM
MAR 25. 2013 1:33 PM
SENSOR ALARM - - - --
L16:DIESEL ANN
ANNULAR SPACE
FUEL ALARM
MAR 25, 2013 1:34 PM
SENSOR ALARM - - - --
LII:REGULAR. 2 STP
STP SUMP
FUEL ALARM
MAR 25. 2013 1:35 PM
SENSOR ALARM - - ---
L12:REGULAR 2 ANN
ANNULAR SPACE
FUEL ALARM
MAR 25, 2013 1:36 PM
SENSOR ALARM - - - --
L 9,: REGULAR 1 STP,
STP SUMP
FUEL ALARM
MAR 25, 2013 1:37 PM
SENSOR ALARM - - - --
L10:REGULAR 1 ANN
ANNULAR SPACE
FUEL ALARM
MAR 25. 2013 1:38 PM
SENSOR ALARM - - - --
L14:SUPER ANN
ANNULAR SPACE
FUEL ALARM
MAR 25. 2013 1:38 PM
SENSOR ALARM - - - --
L13:SUPER STP
STP SUMP
FUEL ALARM
MAR 25, 2013 1:39 PM
SENSOR ALARM - - - --
L 1:DISP 1 -2
DISPENSER PAN
FUEL ALARM
MAR 25, 2013 1:42 PM
SENSOR ALARM - -- -
L 2:DISP 3 -4
DISPENSER PAN
FUEL ALARM
MAR 25, 2013 1 :42 PM
SENSOR ALARM
L 3:DISP 5 -6
DISPENSER PAN
FUEL ALARM
MAR 25, 2013 1:43 PM
SENSOR ALARM - - - --
L 4 :DISP 7 -8
DISPENSER PAN
FUEL ALARM
MAR 25, 2013 1:44 PM
SENSOR. ALARM - - - --
L 5:DISP 9 -10
DISPENSER PAN
FUEL ALARM
MAR 25. 2013 1:46 PM
SENSOR ALARM - - - --
L13:SUPER STP
STP SUMP
SENSOR OUT ALARM
MAR 25, 2013 1:49 PM
SENSOR ALARM - - - --
L 1:DISP 1 -2
DISPENSER PAN
SENSOR OUT ALARM
MAR 25, 2013 1:49 PM
SENSOR ALARM - - - --
L 9:REGULAR 1 STP
STP SUMP
SENSOR OUT ALARM
MAR 25, 2013 1:49 PM
SENSOR ALARM - -- --
L14:SUPER ANN
ANNULAR SPACE
SENSOR OUT ALARM
MAR 25. 2013 1:49 PM
SENSOR ALARM - - - --
L 5:DISP 9 -10
DISPENSER PAN
SENSOR OUT ALARM
MAR 25, 2013 1:49 PM
SENSOR ALARM - - - --
L15:DIESEL STP
STP SUMP
SENSOR OUT ALARM
MAR 25, 2013 1:49 PM
SENSOR ALARM - - - --
L16:DIESEL ANN
ANNULAR SPACE
SENSOR OUT ALARM
MAR 25. 2013 1:49 PM
SENSOR ALARM - - - --
L 2:DISP 3 -4
DISPENSER PAN
SENSOR OUT ALARM
MAR 25. 2013 1:49 PM
SENSOR ALARM - - - --
L10:REGULAR 1 ANN
ANNULAR SPACE
SENSOR OUT ALARM
MAR 25. 2013 1:49 PM
SENSOR ALARM - - - --
L 3:DISP 5 -6
DISPENSER PAN
SENSOR OUT ALARM
MAR 25, 2013 1:49 PI °1
SENSOR ALARM - - - --
L 4:DISP 7 -8
DISPENSER PAN
SENSOR OUT ALARM
MAR 25, 2013 1:49 PM
SENSOR ALARM - - - -- METRO STATION
L11:REGULAR 2 STP 4600 STINE ROAD
STP SUMP BAKERSFIELD, CA
SENSOR OUT ALARH
MAR 25, 2013 1:49 PM
MAR 25, 2013 2:11 PM
SENSOR ALARM
L 12 : REGULAR 2 ANN
ANNULAR SPACE
SENSOR OUT ALARM
MAR 25, 2013 1:49 PM
SENSOR ALARM - - - --
L 2:DISP 3 -4
DISPENSER VAN
FUEL ALARM
MAR 25. 2013 1:57 PM
SYSTEM STATUS REPORT
ALL FUNCTIONS NORMAL
SENSOR ALARM - - - --
L 2 :DISP 3 -4
D 1 SPE14SER PAN
FUEL ALARM
MAR 25, 2013 2:34 PM
METRO STATION
4600 STINE ROAD
BAKERSFIELD, CA
MAR 25. 2013 2:44 PM
P
SYSTEM ASTATUS REPORT
ALL FUNCTIONS NORMAL
SWRCB, January 2006
Spill Bucket Testing Report Form
Thisform is intendedfor use by contractors performing annual testing ofUST spill containment structures. The completedform and
printouts from tests (if applicable), should be provided to thefacility owner /operatorfor submittal to the local regulatory agency.
1. FACILITY INFORMATION
Facility Name: Metro Station Date of Testing: 3/26/2012
Facility Address: 4600 Stine Road
Facility Contact: Mike Phone: 661 -831 -0836
Date Local Agency Was Notified of Testing: 3/19/2013
Name of Local Agency Inspector (fpresent during testing): Ernie Medina
2. TESTING CONTRACTOR INFORMATION
Company Name: Confidence UST Services, Inc.
Technician Conducting Test: Bradley Seykora
Credentials: x CSLB Contractor 9 ICC Service Tech. SWRCB Tank Tester Other (Spec)
License Number(s): CSLB# 804904 ICC# 8111231 -UT
3. SPILL BUCKET TESTING INFORMATION
Test Method Used: x Hydrostatic Vacuum Other
Test Equipment Used: Lake Test Equipment Resolution: 0.0625"
Identify Spill Bucket (By Tank
Number, Stored Product, etc.
l Regular #1 2 Regular #2 3 Super 4 Diesel
Bucket Installation Type: x Direct Bury
Contained in Sump
x Direct Bury
Contained in Sump
x Direct Bury
Contained in Sump
x Direct Bury
Contained in Sum
Bucket Diameter: 12.00" 12.00" 12.00" 12.00"
Bucket Depth: 1 13.50" 13.75" 13.50" 14.00"
Wait time between applying
vacuum /water and start of test:
5 min. 5 min. 5 min. 5 min.
Test Start Time (Ti): 1:15 PM 1:15 PM 1:15 PM 1:15 PM
Initial Reading (Rj): 7.50" 7.25" 7.00" 9.50"
Test End Time (TF): 2:15 PM 2:15 PM 2:15 PM 2:15 PM
Final Reading (RF): 7.50" 7.25" 7.00" 9.50"
Test Duration (TF — Ti): 1 hour 1 hour 1 hour 1 hour
Change in Reading (RF - Rj): 0.00" 0.00" 0.00" 0.00"
Pass/Fail Threshold or
Criteria: 0.0625" 0.0625" 0.0625" 0.0625"
Test Result: 9 Pass Fail 9 Pass Fail 0 Pass Fail 9 Pass Fail
Comments — (include information on repairs made prior to testing, and recommendedfollow -upfor failed tests)
CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING
I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements.
Technician's Signature: Date: 03/25/2013
State laws and regulations cfo not currently require testing to be performed by a qualified contractor. However, local requirements
may be more stringent.
1= Veeder Root TLS 350
2= External Overfill Alarm
3= ESO Switch
4= Veeder Root ATG Probe
5= Veeder :Boot 208 Sump Sensor
6= Veeder :Root 420 Annular Seri.
7= FX1 V Line Leak Detector
8= PX1 DV Lire Leak Detector
9= Regular 1 STP Sump
1 g= Regualr 2 STP Sump
11= Super STP Sump
12= Diesel STP Sump
13= Regular I Spill Bucket
14= Regular 1 Vapor Bucket
15= Regular 2 Spill Bucket
15= Regular 2 Vapor Bucket
17= Super Spill Bucket
18= Super Vapor Bucket
19= Diesel Spill Bucket
Metro Station
4600 Stine Road
Bakersfield, CA 9a3O9
1
I L-
5 4 e7' I I
57,9.
103 94
5,7,10
35 16
05,8,12,
A 9
1. 4. L..