HomeMy WebLinkAboutFMC 2013HOODS ALARMS SPRINKLER SYSTEMS SPRAY BOOTH AST UST
Permit No. Permit No. Permit No. Permit No. Permit No. Permit No.
az6=3SS-5
File Number: f2 K Address: -5-3 z I S(oc
Bakersfield, CA 933
Date Received: r„- i3 _
Business Name: S oc <<
SYSTEM: IF BUILDING SQUARE FEET: INSPECTION LOG
New Mod.
Commercial Hood System
Fire Alarm System
Fire Sprinkler System
Spray FiNsh System
Aboveground Storage Tank
Underground Storage Tank
minor
modification Underground Storage Tank
removal Underground Storage Tank
Ga' Other. f-w C-1
Comments:
Building Sq. Feet:
Calculation Bldg. Sq. Ft: 1.
2.
3.
4.
natp Timp
Signature
1 %.—
MONITORING SYSTEM CERTIFICATION
For Use By All Jurisdictions Within the State ofCalifornia
Authority Cited: Chapter 6 7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code ofRegulations
This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be nrenared for each
monitoring system control panel by the technician who performs the work. A copy ofthis form must be'provided to the tank system owner /operator.
The owner /operator must submit a copy ofthis form to the local agency regulating UST systems within 30 days of test date.
A. General Information
Facility Name: STOCKDALE FOODMART Bldg. No.:
Site Address: 5321 STOCKDALE HWY City: BAKERSFIELD Zip:
Facility Contact Person: FONIG CHAO
Make/Model ofMonitoring System: TLS -350
B. Inventory of Equipment Teste&Certified
Check the appro riate boxes to indicatespecific equipment inspected/serviced:
Contact Phone No.: ( )
Date of Testing/Servicing: 81271201 3
Tank ID: UNL87 Tank ID: PREM91
In -Tank Gauging Probe. Model: MAG In -Tank Gauging Probe. Model: MAG
Annular Space or Vault Sensor. Model: 420/463 Annular Space or Vault Sensor. Model: 420/463
Piping Sump / Trench Sensor(s). Model: 2081304 Piping Sump / Trench Senors). Model: 2081304
Fill Sump Sensor(s). Model: 2081304 Fill Sump Sensor(s). Model: 2081304
Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model:
Electronic Line Leak Detector. Model: VEEDER -ROOT Electronic Line Leak Detector. Model: VEEDER -ROOT
Tank Overfill / High -Level Sensor. Model: GOA Tank Overfill / High -Level Sensor. Model: GOA
Other (specify equipment type and model in Section E on Page 2). Other (specify equipment type and model in Section E on Page 2).
Tank ID: DIESEL Tank ID: VENT BOX
In -Tank Gauging Probe, Model: MAG In -Tank Gauging Probe. Model:
Annular Space or Vault Sensor. Model: 4021463 Annular Space or Vault Sensor. Model:
Piping Sump / Trench Sensor(s). Model: 2081304 Piping Sump / Trench Sensor(s). Model: 2081304
Fill Sump Sensor(s). Model: 208/304 Fill Sump Sensor(s). Model:
Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model:
Electronic Line Leak Detector. Model: VEEDER -ROOT Electronic Line Leak Detector. Model:
Tank Overfill / High -Level Sensor. Model: GOA Tank Overfill / High -Level Sensor. Model:
Other (specify equipment type and model in Section E on Page 2). Other (specify equipment type and model in Section E on Page 2).
Dispenser ID: 112 Dispenser ID: 314
Dispenser Containment Sensor(s). Model: 2081304 Dispenser Containment Sensor(s). Model: 2081304
Shear Valve(s). Shear Valve(s).
Dispenser Containment Float(s) and Chain(s). Dispenser Containment Float(s) and Chain(s).
Dispenser ID: 516 Dispenser ID: 718
Dispenser Containment Sensor(s). Model: 208/304 Dispenser Containment Sensor(s). Model: 2081304
Shear Valve(s). Shear Valve(s).
Dispenser Containment Float(s) and Chain(s). Dispenser Containment Float(s) and Chain(s).
Dispenser ID: 9110 Dispenser ID:
Dispenser Containment Sensor(s). Model: 208/304 Dispenser Containment Sensor(s). Model:
Shear Valve(s). Shear Valve(s).
Dispenser Containment Float(s) and Chain(s). Dispenser Containment Float(s) and Chain(s).
Ifthe facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility.
C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'
guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is
correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also
attached a copy of the report; (check all that apply): ® System set -up ® Alarm history report
Technician Name (print): RICHARD MASON Signature: r
Certification No.: B3688015297857 -UT License. No.: C6 D40 809850
Testing Company Name: RICH ENVIRONMENTAL Phone No.: (661) 392 -8687
Testing Company Address: 5643 BROOKS CT. BAKERSFIELD, CA 93308 Date of Testing/Servicing: 8/27/2013
Page 1 of 5
UN- 036 -1/4 www.unidocaorg Rev. 01 /17/08
Monitoring System Certification
D. Results of Testing/Servicing
Software Version Installed: 330.02
rmmnlete the Mllnwina Apeklict!
Yes No* Is the audible alarm operational?
IR Yes No* Is the visual alarm operational?
Yes No* Were all sensors visually inspected, functionally tested, and confirmed operational?
Yes No* Were all sensors installed at lowest point ofsecondary containment and positioned so that other equipment will
not interfere with their proper operation?
Yes No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem)
N/A operational?
Yes No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment
N/A monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate
positive shut -down? (Check all that apply) ® Sump/Trench Sensors; ® Dispenser Containment Sensors.
Did you confirm positive shut -down due to leaks an sensor failure /disconnection? IS Yes; No.
Yes p No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no
N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank
fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? 90%
Yes* No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced
and list the manufacturer name and model for all replacement parts in Section E, below.
Yes* No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)
Product; Water. Ifyes, describe causes in Section E, below.
Yes No* Was monitoring system set -up reviewed to ensure proper settings? Attach set up reports, if applicable
Yes 1 No* I Is all monitoring equipment operational per manufacturer's specifications?
In Section E below, describe how and when these deficiencies were or will be corrected.
E. Comments: 1) 91 SPILL BUCKET FAILED LAKE TEST. DRAIN WAS CLOGGED, I CLEANED AND RETESTED -
PASSED
Page 2 of 5
UN-036 — 2/4 www.unidocs.org Rev. 01 /17/08
Monitoring System Certification
F. In -Tank Gauging / SIR Equipment: Check this box if tank gauging is used only for inventory control.
Check this box if no tank gauging or SIR equipment is installed.
This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring.
Complete the following checklist:
Yes No* Has all input wiring been inspected for proper entry and termination, including testing for ground faults?
Yes No* Were all tank gauging probes visually inspected for damage and residue buildup?
Yes No* Was accuracy of system product level readings tested?
Yes No* Was accuracy ofsystem water level readings tested?
Yes No* Were all probes reinstalled properly?
Yes No* Were all items on the equipment manufacturer's maintenance checklist completed?
In Section H, below, describe how and when these deficiencies were or will be corrected.
G. Line Leak Detectors (LLD):
Cmmnlete the fnllnwino Apeklict!
Check this box ifLLDs are not installed.
Yes No* For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance?
N/A Check all that apply) Simulated leak rate: ® 3 g.p.h.; [10. 1 g.p.h ; 0.2 g,p.h.
Yes No* Were all LLDs confirmed operational and accurate within regulatory requirements?
Yes No* Was the testing apparatus properly calibrated?
Yes No* For mechanical LLDs, does the LLD restrict product flow if it detects a leak?
N/A
Yes No* For electronic LLDs, does the turbine automatically shut off ifthe LLD detects a leak?
N/A
Yes No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled
N/A or disconnected?
Yes No* For electronic LLDs, does the turbine automatically shut off ifany portion ofthe monitoring system malfunctions
N/A or fails a test?
Yes No* For electronic LLDs, have all accessible wiring connections been visually inspected?
N/A
Yes No* Were all items on the equipment manufacturer's maintenance checklist completed?
In Section H, below, describe how and when these deficiencies were or will be corrected.
H. Comments:
UN -036 — 3/4
Page 3 of 5
www.unidocs.org Rev. 01/17/08
r.
V V i.
f- I is IF i 0 v 4 -4 t v 4. • a I t a :4 1 k V .0 a a
A -0
j 8
a w 4 1 'r 'i CL X I A jw .1 L +
s i it t;!• a a t:flK "A- 4 V • 4
I q
L
a - W-
5, A' 4k. -8 a .4 9 6 It ' -I
k 'I v jv 4 a 14-4 i i i: .i -
j, IF. h: s At 4. r -F t -1 • v v I , T, 1p <K 0 1. ilr41I1r4w ' k
B Ir g 1 .4 r it f. r
X t L
it A w I F"a 4 -C.1,4 ri
1 .14 • -p A Ijr ;k it
Al 1 0 It
ort ,r1 a-6
W --;,Ljr a A-4 4
I kA ft
jr- :k zk i k t iL a - v -7jIM a
4; A' 14•'1 lk I a • it 9 1 it 14 C'! "1 .04. • -0, % W.- •"
Ot I -P,A,.A A IL A zo 't tip
I'L
t AL Y a f a
I • A. 4- I or. -A • it 4 -k d T-W
k if.p .1 .4 1 4 kl' 10 k t
c A • or •0. if, -$- 'vx --p i
s IA .1 11 IP *A • 1 '1--f I. J. 0 1 4
R A 1 40 .11 fA • t • Y
f* -I. v j 9 4. 0j 4L
4t ;C it. -4 •
wit fl,
41
4 k a 4, Ir
J
S'11
1 0 1 r• A • f a a! s a -0 a 4 1 s a
19
RICHENVIRONMENTAL
5643 BROOKS CT. BAKERSFIELD, CA. 93308
OFFICE (661)392 -8687 FAX (661)392 -0621
PRODUCT LINE LEAK DETECTOR TEST
WORK SHEET
W /0#:
FACILITY NAME: STOCKDALE FOODMART
FACILITY ADDRESS: 5321 STOCKDALE HWY, BAKERSFIELD
PRODUCT LINE TYPE: PRESSURE
PRODUCT LEAK DETECTOR TYPE TEST TRIP PASS
BELOW P.S.I. OR
SERIAL NUMBER 3 G.P.H. FAIL
87 L/D TYPE: VEEDER -ROOT YES 0 PASS
SERIAL # ELECTRONIC
91 L/D TYPE: VEEDER -ROOT YES 0 PASS
SERIAL # ELECTRONIC
DIESEL L/D TYPE: VEEDER -ROOT YES 0 PASS
SERIAL # ELECTRONIC
L/D TYPE: YES PASS
SERIAL # NO FAIL
I CERTIFY THE ABOVE TESTS WERE CONDUCTED ON THIS DATE ACCORDING TO RED
JACKET PUMPS FIELD TEST APPARATUS TESTING PROCEDURE AND LIMITATIONS.
THE MECHANICAL LEAK DETECTOR TEST PASS / FAIL IS DETERMINED BY USING A
LOW FLOW THRESHOLD TRIP RATE OF 3 GALLONS PER HOUR OR LESS AT 10 P.S.I. I
ACKNOWLEDGE THAT ALL DATA COLLECTED IS TRUE AND CORRECT TO THE BEST
OF MY KNOWLEDGE.
TECHNICIAN RICHARD MASON
SIGNATURE: 71/ DATE: 8127/13
r
SWRCB, January 2006
Spill Bucket Testing Report Form
Thisform is intendedfor use by contractors performing annual testing of UST spill containment structures. The completedform and
printoutsfrom tests (ifapplicable), shouldbeprovided to thefacility owner /operatorfor submittal to the local regulatory agency.
1. FACILITY INFORMATION
Facility Name: STOCKDALE FOODMART Date ofTesting: 8/27/13
Facility Address: 5321 STOCKDALE HWY, BAKERSFIELD
Facility Contact: FONIG CHAD I Phone:
Date Local Agency Was Notified of Testing: 7/9/13
Name of Local Agency Inspector (fpresent during testing): ERNIE MEDINA
2. TESTING CONTRACTOR INFORMATION
Company Name: RICH ENVIRONMENTAL
Technician Conducting Test: RICHARD MASON
Credentials': CSLB Contractor X ]CC Service Tech. 0 SWRCB Tank Tester Other (Specify)
License Number(s): 5297857 -UT
3. SPILL BUCKET TESTING INFORMATION
Test Method Used: X Hydrostatic 0 Vacuum Other
Test Equipment Used: VISUAL Equipment Resolution: 0
Identify Spill Bucket (By Tank
Number, Stored Product, etc.
1 87 2 91 3 DIESEL 4 91 RE -TEST
Bucket Installation Type: 0 Direct Bury
X Contained in Sump
Direct Bury
X Contained in Sump
0 Direct Bury
X Contained in Sump
Direct Bury
X Contained in Sum
Bucket Diameter: 12" 12" 12" 1299
Bucket Depth: 14" 14" 14" 14"
Wait time between applying
vacuum /water and start of test: 30MIN 30MIN 30MIN 30MIN
Test Start Time (Tj): 9:00 9:00 9:00 9:30
Initial Reading (111): 14" 5" 14" 14"
Test End Time (TF): 10:00 10:00 10:00 10:30
Final Reading (RF): 14" 0" 14" 14"
Test Duration (TF — Tj): 60MIN 60MIN 60MIN 60MIN
Change in Reading (RF - Ri): 0 5" 0 0
Pass/Fail Threshold or
Criteria: 0.00 0.00 0-00 0.00
Test Result: X Pass 0 Fail Pass X Fail X Pass 0 Fail X Pass 0 Fail
Comments — (include information on repairs made prior to testing, and recommendedfollow -upforfailed tests)
91 SPILL BUCKET FAILED LAKE TEST. I CLEANED DRAIN. RETESTED - PASSED
CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING
I hereby certJ& that all the information contained in this report is true, accurate, and infull compliance with legal requirements.
Technician's Signature: Date: 8/27/13
State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements
may be more stringent.
IN -TANK SETUP COMMUNICATIONS SETUP
SYSTEM SETUP
T 1:87 AUG 27, 2013 9:46 AM
PRODUCT CODE 1 PORT SETTINGS:
THERMAL COEFF :.000700
TANK DIAMETER 113.75 COMM BOARD : 1 (EDIM }
TANK PROFILE I PT RS -232 SECURITY SYSTEM UNITS
FULL VOL 15022 CODE : DISABLED U.S.
SYSTEM LANGUAGE
COMM BOARD : 2 (RS -232) ENGLISH
FLOAT SIZE: 3.0 IN. BAUD RATE : 1200 SYSTEM DATE /TIME FORMAT
PARITY : ODD MON DD YYYY HH:MM:SS xM
WATER WARNING : 2.0 STOP BIT : 1 STOP
HIGH WATER LIMIT: 3.0 DATA LENGTH: 7 DATA STOCKDALE FOOD MART
RS -232 SECURITY 5321 STOCKDALE HWY
MAX OR LABEL VOL: 15022 CODE : DISABLED BAKERSFIELD CA 93309
OVERFILL LIMIT : 720%
10615 COMM BOARD 3 (FXMOD)
HIGH PRODUCT 76% BAUD RATE : 2400 SHIFT TIME 1 DISABLED
11 PARITY ODD SHIFT TIME 2 : DISABLED
DELIVERY LIMIT STOP BIT 1 STOP SHIFT TIME 3 DISABLED
1502 DATA LENGTH: 7 DATA SHIFT TIME 4 DISABLED
SECURITY
LOW PRODUCT 500 CODE : CODE DISABLED TANK PER TST NEEDED WRN
LEAK ALARM LIMIT: 99 DIAL TYPE : TONE DISABLED
SUDDEN LOSS LIMIT: 50 ANSWER ON : 1 RING TANK ANN TST NEEDED WRN
TANK TILT 0.00 MODEM SETUP STRING : DISABLED
PROBE OFFSET 0.00
DIAL TONE INTERVAL: 32 LINE RE- ENABLE METHOD
PASS LINE TEST
SIPHON MANIFOLDED TANKS
TO: NONE AUTO TRANSMIT SETTINGS: LINE PER TST NEEDED WRN
LINE MANIFOLDED TANKS DISABLED
TO: NONE AUTO LEAK ALARM LIMIT DINE ANN TST NEEDED WRN
DISABLED
AUTO HIGH WATER LIMIT
LEAK MIN PERIODIC: DISABLED PRINT TC VOLUMES
1502 AUTO OVERFILL LIMIT ENABLED
DISABLED
LEAK MIN ANNUAL : 10% AUTO LOW PRODUCT TEMP COMPENSATION
1502 DISABLED VALUE (DEG F ): 60.0
AUTO THEFT LIMIT STICK HEIGHT OFFSET
DISABLED DISABLED
PERIODIC TEST TYPE AUTO DELIVERY START ULLAGE: 90%
STHNDARD DISABLED
AUTO DELIVERY END H- PROTOCOL DATA FORMAT
ANNUAL TEST FAIL DISABLED HEIGHT
ALARM DISABLED AUTO EXTERNAL INPUT ON PRECISION TEST DURATION
DISABLED
PERIODIC TEST FAIL AUTO EXTERNAL INPUT OFF DAYLIGHT SAVING TIME
ALARM DISABLED DISABLED ENABLED
AUTO SENSOR FUEL ALARM START DATE
GROSS TEST FAIL DISABLED APR WEEK 1 SUN
ALARM DISABLED AUTO SENSOR WATER ALARM START TIME
DISABLED 2:00 AM
ANN TEST AVERAGING: OFF AUTO SENSOR OUT ALARM END DATE
PER TEST AVERAGING: 'OFF DISABLED OCT WEEK 6 SUN
END TIME
TANK TEST NOTIFY: OFF 2 :00 AM
TNK TST SIPHON BREAK:OFF RE- DIRECT LOCAL PRINTOUT
DISABLED
DELIVERY DELAY : 15 MIN' RECEIVER SETUP:
PUMP THRESHOLD : 10.00% EURO PROTOCOL PREFIX
NONE S
SYSTEM SECURITY
CODE : 000000
MAINTENANCE HISTORY
DISABLED
LEAK 'PEST METHOD
TEST ANNUALLY: ALL TANK
DEC WEEK 1
2SUN
AMSTARTTIME
DURATION :0220NAL/HR
TST EARLY STOP:DISABLED
LEAK TEST REPORT FORMAT
PRESSURE LINE LEAK SETUP
A 1:87
2YOIN• DIA
F
LEN:
120R
B
FEET
3.0IN DIA LEN: 0 FEET
SHUTDOWN RATE: 3.0 GPH
LOW PRESSURE SHUT40 : NO
LOW PRESSURE PSI
T 1-87
DISPENSE MODE:
STANDARD
SENSOR: NON— VENTED
PRESSURE OFFSET: O.OPSI
MECHANICAL BLENDER: NO
A 2:91
TYP :2.0/3.0IN FIBERGLASS
2.0IN DIA LEN: 120 FEET
3.0IN DIA LEN: 0 FEET
SHUTDOWN RATE: 3.0 GPH
LOW PRESSURE SHUTOFF :NO
LOW PRESSURE
T. 2:91
DISPENSE MODE:
STANDARD
SENSOR: NON— VENTED
PRESSURE OFFSET: O.OPSI
MECHANICAL BLENDER: NO
T 3:DIESEL
PRODUCT CODE 3
THERMAL COEFF 000450
TANK DIAMETER 113.75
TANK PROFILE 1 PT
FULL VOL 7070
FLOAT SIZE: 3.0 IN.
WATER WARNING 2.0
HIGH WATER LIMIT: 3.0
MAX OR LABEL VOL: 7070
OVERFILL LIMIT 90%
6363
HIGH PRODUCT 95%
6716
DELIVERY LIMIT : 10%
707
LOW PRODUCT 500
LEAK ALARM LIMIT: 99
SUDDEN LOSS LIMIT: 50
TANK TILT 0.00
PROBE OFFSET 0.00
SIPHON MANIFOLDED TANKS
TO: NONE
LINE MANIFOLDED TANKS
TO: NONE
LEAK MIN PERIODIC: 10%
707
LEAK MIN ANNUAL 10%b
707
PERIODIC TEST TYPE
STANDARD
ANNUAL TEST FAIL
ALARM DISABLED
PERIODIC TEST FAIL
ALARM DISABLED
GROSS TEST FAIL,
ALARM DISABLED
ANN TEST AVERAGING: OFF
PER TEST AVERAGING: OFF
TANK TEST NOTIFY: OFF
TNK TST SIPHON BREAK:OFF
DELIVERY DELAY 15 MIN
PUMP THRESHOLD 10.00%
0 % L -0-
r
T 2:91
2.0
PRODUCT CODE 2
THERMAL COEFF 000700
TANK DIAMETER 113.75
TANK PROFILE i PT
FULL Vol. 804'2'
FLOAT SIZE: 3.0 IN.
WATER WARNING 2.0
HIGH WATER LIMIT: 3.0
MAX OR LABEL VOL: 8042
OVERFILL LIMIT : 90%
7237
HIGH PRODUCT 95%
7639
DELIVERY LIMIT : 10%
804
LOW PRODUCT 500
LEAK ALARM LIMIT: 99
SUDDEN LOSS LIMIT: 50
TANK TILT 0.00
PROBE OFFSET 0.00
SIPHON MANIFOLDED TANKS
Tit: NONE
LINE MANIFOLDED TANKS
TO: NONE
LEAK MIN PERIODIC: 1(?n
804
LEAK MIN ANNUAL : 10%
804
PERIODIC TEST TYPE
STANDARD
ANNUAL TEST FAIL
ALARM DISABLED
PERIODIC TEST FAIL
ALARM DISABLED
GROSS TEST FAIL
ALARM DISABLED
ANN TEST AVERAGING: OFF
PER TEST AVERAGING: OFF
TANK TEST NOTIFY: OFF
TNK TST SIPHON BREAK:OFF
DELIVERY DELAY 15 MIN
PUMP THRESHOLD 10.001a
PLLD LINE DISABLE SETUP
Q 1:87
LIQUID SENSOR ALMS
L 1:FUEL ALARM
L 9:FUEL ALARM
L15 :FUEL ALARM
L 17 :.FUEL ALARM
L19:FUEL ALARM
L21:FUEL ALARM
L23:FUEL ALARM
L 1:SENSOR OUT ALARM
L 9:SENSOR OUT ALARM
L15:SENSOR OUT ALARM
L17:SENSOR OUT ALARM
L 19 : S'ENSOR OUT ALARM
L21 :SENSOR OUT ALARM
L23 :SENSOR OUT ALARM
ISD SITE ALARMS
ISD GROSS PRES FAIL
ISD DEGRD PRE$ FAIL
ISD VAPOR LEAK FAIL
ISD VP PRES FAIL
ISD VP STATUS FAIL
ISD HOSE ALARMS
ALL:GROSS COLLECT FAIL
ALL:DEGRD COLLECT FAIL
ALL:FLOW COLLECT FAIL
Q 2:91
LIQUID SENSOR ALMS
L 3:FUEL ALARM
L15-FUEL ALARM
L17:FUEL ALARM
L19-FUEL ALARM
L21:FUEL ALARM
L23 :FUEL ALARM
L W SENSOR OUT ALARM
L15:SENSOR OUT ALARM
L17:SENSOR OUT ALARM
L19 :SENSOR OUT ALARM
1.21:8ENOOR OUT ALARM
L23:SENSOR OUT ALARM
ISD SITE ALARMS
ISD GROSS PRES FAIL
ISD DEGRD PRES FAIL
ISD VAPOR LEAK FAIL
ISD VP PRES FAIL
ISD VP STATUS FAIL
ISD SETUP FAIL
ISD HOSE ALARMS
ALL:GROSS COLLECT FAIL
ALL:DEGRD COLLECT FAIL
Q 3:DIEBEL
LIQUID SENSOR ALMS
L 5:FUEL ALARM
L13:FUEL ALARM
L19:FUEL ALARM
L23:FUEL ALARM
L 5 :SENSOR OUT ALARM
L M SENSOR OUT ALARM
L19:SENSOR OUT ALARM
L23 :SENSOR OUT ALARM
L13 :DIESEL FILL
TRI -STATE (SINGLE FLOAT) CATEGORY : PIPING SUMP LIQUID SENSOR SETUP
L W DIESEL FILL ANNTRI -STATE TRI. -STATE
STP
SINGLE FLOAT) SINGLE FLOAT)* CATEGORY : ANNULAR SPACE STP SUMP
L 2:87 STP ANN
L15:DISP 1 -2 TRI-STATE (SINGLE FLOAT)
CATEGORY ANNULAR SPACETRI -STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN
L 3:91 STP
L16:DISP 1-2 ANN TRI -STATE (SINGLE FLOAT)
CATEGORY STP SUMPTRI -STATE (SINGLE FLOAT) CATEGORY : ANNULAR SPACE
L 4:91 STP ANN
TRI -STATE (SINGLE FLOAT)
L17:DISP 3 -4 CATEGORY : ANNULAR SPACE
TRI -STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN
L 5:DIESEL STP
TRI-STATE (SINGLE FLOAT)
L18:DISP 3 -4 ANN CATEGORY : STP SUMP
TRI -STATE (SINGLE FLOAT) . CATEGORY : ANNULAR SPACE L 6:DIESEL STP ANN
TRI-STATE (SINGLE FLOAT) CATEGORY : ANNULAR SPACE
LI9 :DISP 5 -6
TRI -STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN L 7:VENT
TRI -STATE (SINGLE FLOAT) CATEGORY : OTHER SENSORS
L20:DISP 5 -6 ANNTRI -STATE (SINGLE FLOAT) CATEGORY : ANNULAR SPACE L 8:VENT ANN
TRI -STATE (SINGLE FLOAT)
CATEGORY : ANNULAR SPACE
L21:DISP 7 -8
TRI -STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN L 9:87 FILL
TRI -STATE (SINGLE FLOAT)
CATEGORY : PIPING SUMP
L22:DISP 7 -8 ANNTRI-STATE (SINGLE FLOAT) CATEGORY : ANNULAR SPACE L10:87 FILL ANN
TRI -STATE (SINGLE FLOAT)
CATEGORY : ANNULAR SPACE
L23:DISP 9 -10
TRI -STATE (SINGLE FLOAT) CATEGORY : DISPENSER PAN L11:91 FILL
TRI -STATE (SINGLE FLOAT)
CATEGORY : PIPING SUMP
L24 :DISP 9 -10 ANNTRI -STATE (SINGLE FLOAT) L12:91 FILL ANN
TRI -STATE (SINGLE FLOAT) CATEGORY : ANNULAR SPACE CATEGORY : ANNULAR SPACE
ALARM HISTORY REPORT
SENSOR ALARM -- - --
L 1:87 STP
STP SUMP
SENSOR OUT ALARM
AUG 27, 2013 10:16 AM
FUEL ALARM
AUG 27. 2013 9:58 AM
SENSOR OU•T ALARM
AUG 27. 2012 2:58 PM
xkxxx END X*x**
ALARM HISTORY REPORT
SENSOR ALARM - - - --
L 2:87 STP ANN
ANNULAR SPACE
FUEL ALARM
AUG 27, 2013 10:28 AM
SENSOR OUT ALARM
AUG 27. 2013 10:16 AM
FUEL ALARM
AUG 27, 2012 2:59 PM
x * % x * END X * * * x
ALARM HISTORY REPORT
SENSOR ALARM - - - --
L 3:91 STP
STP SUMP
SENSOR OUT ALARM
AUG 27, 2013 10:16 AM
FUEL ALARM
AUG 27, 2013 10 :05 AM
SENSOR OUT ALARM
AUG 27, 2012 2:58 PM
E•VR /ISD SETUP
EVR TYPE: VACUUM ASSIST
VACUUM ASSIST TYPE
HEALY VAC
NOZZLE A/L RANGE
MAX: 1.15 MIN: 0.95
VAPOR PROCESSOR TYPE
NONE
ANALYSIS TIMES
TIME: 9:59 AM
DELAY MINUTES: 1
ACCEPT HIGH ORVR:
ENABLED
ISD HOSE TABLE
NUM LABEL
1
ID FP FL HL AA RR
01 01 01 02 01 00
02 02 02 02 01 00
03 03 03 02 02 00
04 04 04 02 02 00
05 05 05 02 03 00
06 06 06 02 03 00
07 07 07 02 04 00
08 08 08 02 04 00
09 09 09 02 05 00
10 16 10 02 05 00
ISD AIRFLOW METER MAP
ID SERIAL NUM LABEL
1
7-r1. ,7231 DISP 1 -2 F
2`51729 DISP 3 -4 F
3 50776 DISP 5 -6 F
4 7020 DISP 7 -8 F
5 58152 DISP 9 -10
ISD FUEL GRADE HOSE MAP
1 2 3 4
FP MHH MHH MHH MHH AA
01 101 901 201 U U 1
02 102 902 202 U U 1
03 103 903 203 U U 2
04 104 904 204 U U 2
05 105 905 205 3 U 3
06 106 906 206 3 U 3
07 107 907 207 U U 4
08 108 908 208 U U 4
09 109 909 209 3 U 5
15 110 910 210 3 U 5
LABEL TABLE
1: UNASSIGNED
2: BLEND 3
3: REGULAR
4: MID GRADE
5: PREMIUM
6: GOLD
7: BRONZE
8: SILVER
9: BLEND2
10: BLEND4
s 1:87 TANK ANN
CATEGORY VAC SENSOR
PUMP 13:
A 1:87
VOLUME: 205.7 GALLONS
RELIEF VALVE: : NO
s 2 :87 VENT
CATEGORY VAC SENSOR
PUMP 0:
A 1:87
VOLUME: 128.8 GALLONS
RELIEF VALVE: : NO
s 3:87 -91 VAPOR
CATEGORY VAC SENSOR
PUMP It :
Q 1:87
VOLUME: 64.4 GALLONS
RELIEF VALVE: : NO
s 4:87 -PROD
CATEGORY VAC SENOR
PUMP 0:
Q 1:87
VOLUME: 99.0 GALLONS
RELIEF VALVE: : NO
s 5:91 VENT
CATEGORY VAC SENSOR
PUMP 0:
Q 291
VOLUME: 64.4 GALLONS
RELIEF VALVE: : NO
s 6:91 PROD
CATEGORY VAC SENSOR
PUMP 0:
Q 2:91
VOLUME: 110.4 GALLONS
RELIEF VALVE: : NO
s 7:DIESEL -91 TANK ANN
CATEGORY VAC SENSOR
PUMP #:
Q 3 :DIESEL
VOLUME: 205.7 GALLONS
RELIEF VALVE: : NO
s 8:DIESEL PROD
CATEGORY VAC SENSOR
PUMP #:
Q 3:DIESEL
VOLUME: 110,4 GALLONS
RELIEF VALVE: : NO
s 9:DIESEL VENT
CATEGORY VAC SENOR
PUMP 1S:
Q 3:DIESEL
VOLUME: 64.4 GALLONS
RELIEF VALVE: : NO
s10:DISP 1 -2 FM
CATEGORY AIR FLOW METER
s11:DISP 3 -4 FM
CATEGORY AIR FLOW METER
512 :DISP 5 -6 FM
CATEGORY AIR FLOW METER
s13:DISP 7 -8 FM
CATEGORY AIR FLOW METER
s14:DISP 9 -10 FM
CATEGORY AIR FLOW METER
s15:DISP 5 -6 VP
CATEGORY VAPOR PRESSURE
516:ATM PRESS
CATEGORY ATM P SENSOR
L 0.0-
ALARM HISTORY REPORT
SENSOR ALARM
L10:67 FILL ANN
ANNULAR SPACE
FUEL ALARM
AUG 27, 2013 10:28 AM
SENSOR OUT ALARM
AUG 27, 2013 10 :16 AM
FUEL ALARM
AUG 27, 2012 2:59 PM
xw * *x END ** *0*
ALARM HISTORY REPORT
SENSOR ALARM --- --
L11:91 FILL
PIPING SUMP
SENSOR OUT ALARM
AUG 27. 2013 10:16 AM
FUEL ALARM
AUG 27, 2013 10:06 AM
SENSOR OUT ALARM
AUG 27, 2012 2:58 PM
END * * * * *
ALARM HISTORY REPORT
SENSOR ALARM --
L12:91 FILL ANN
ANNULAR SPACE
FUEL ALARM
AUG 27, 2013 10:27 AM
SENSOR OUT ALARM
AUG 27, 2013 10:16 AM
FUEL ALARM
n oo. 7nr3 12:39 PM
ALARM HISTORY REPORT
SENSOR ALARM --
L 7:VENT
OTHER SENSORS
FUEL ALARM
AUG 27, 2013 10:33 AM
SENSOR OUT ALARM
AUG 27, 2013 10 :16 AM
FUEL ALARM
AUG 27. 2012 3 :05 PM
END * * * * *
ALARM HISTORY REPORT
SENSOR ALARM - - - --
L B:VENT ANN
ANNULAR SPACE
FUEL ALARM
AUG 27, 2013 10:33 AM
SENSOR OUT ALARM
AUG 27. 2013 10:16 AM
FUEL ALARM
AUG 27, 2012 3:05 PM
END * * * * *
ALARM HISTORY REPORT
SENSOR ALARM - - - --
L 9:87 FILL
PIPING SUMP
SENSOR OUT ALARM
AUG 27, 2013 10:16 AM
FUEL ALARM
AUG 27, 2013 10:07 AM
SENSOR OUT ALARM
AlIC 27. 2012 2:58 PM
SENSOR ALARM - - - --
L 4:91 STP ANN
ANNULAR SPACE
FUEL ALARM
AUG 27. 2013 10:27 AM
SENSOR OUT ALARM
AUG 27, 2013 10 :16 AM
FUEL ALARM
AUG 27, 2013 5:31 AM
END **x**
ALARM HISTORY REPORT
SENSOR ALARM - - - --
L 5:DIESEL STP
STP SUMP
SENSOR OUT ALARM
AUG 27. 2013 10:16 AM
FUEL ALARM
AUG 27, 2013 10:01 AM
SENSOR OUT ALARM
AUG 27. 2012 2:58 PM
x x * END * * * x *
ALARM HISTORY REPORT
SENSOR ALARM - - - --
L 6:DIESEL STP ANN
ANNULAR SPACE
FUEL ALARM
AUG 27, 2013 10:26 AM
SENSOR OUT ALARM
AUG 27, 2013 10:16 AM
FUEL ALARM
JAN 28, 2013 6:45 AM
J1 l-.71-j
ALARM HISTORY REPORT
SENSOR ALARM -----
L19:DISP 5 -6
DISPENSER PAN
SENSOR OUT ALARM
AUG 27. 2013 10:16 AM
FUEL ALARM
AUG 27, 2013 10:14 AM
SENSOR OUT ALARM
AUG 27. 2012 2:56 PM
x x x x x END x x x x x
ALARM HISTORY REPORT
SENSOR ALARM - - - -_
L20:DISP 5 -6 ANN
ANNULAR SPACE
FUEL ALARM
AUG 27, 2013 10:31 AM
SENSOR OUT ALARM
AUG 27. 2013 10:16 AM
FUEL ALARM
AUG 27, 2012 2:59 PM
x* x* END * x* x x
ALARM HISTORY REPORT
SENSOR ALARM --
L21:DISP 7 -8
DISPENSER PAN
SENSOR OUT ALARM
AUG 27. 2013 10:16 AM
FUEL ALARM
AUG 27, 2013 10:14 AM
SENSOR OUT ALARM
Al lel 017. on t 9 P: 58 PM
ALARM HISTORY REPORT
SENSOR ALARM - - - --
L16:DISP 1 -2 ANN
ANNULAR SPACE
FUEL ALARM
AUG 27. 2013 10:28 AM
SENSOR OUT ALARM
AUG 27. 2013 10:16 AM
FUEL ALARM
AUG 27. 2012 5:46 PM
x x x x x END x x x x*
ALARM HISTORY REPORT
SENSOR ALARM - - - --
L17:DISP 3 -4
DISPENSER PAN.
SENSOR OUT ALARM
AUG 27, 2013 10:16 AM
FUEL ALARM
AUG 27, 2013 10:12 AM
SENSOR OUT ALARMAUG27. 2012 2:58 PM
x x** x END x x x x x
ALARM HISTORY REPORT
SENSOR ALARM - - - --
L18:DISP 3 -4 ANN
ANNULAR SPACE
FUEL ALARM
AUG 27, 2013 10:29 AM
SENSOR OUT ALARMAUG27, 2013 10:16 AM
FUEL ALARM
Al h- oo nn I f . ao na
ALARM HISTORY REPORT
J! L ..r-
SENSOR ALARM - - - --
L13:DIESEL FILL
PIPING SUMP
SENSOR OUT ALARM
AUG 27, 2013 10:16 AM
FUEL ALARM
AUG 27, 2013 10:03 AM
SENSOR OUT ALARM
AUG 27, 2012 2:56 PM
x* x x x END x x x* x
ALARM HISTORY REPORT
SENSOR ALARM - - - --
L14 :DIESEL FILL ANN
ANNULAR SPACE
FUEL ALARM
AUG 27. 2013 10:27 AM
SENSOR OUT ALARM
AUG 27. 2013 10:16 HM
FUEL ALARM
JUN 28. 2013 6:49 AM
xxxx END xx *x'x
ALARM HISTORY REPORT
SENSOR ALARM - - - --
L15 *18P 1 -2
DISPENSER PAN
SENSOR OUT ALARM
AUG 27, 2013 10:16 AM
FUEL ALARM
AUG 27, 2013 10:10 AM
SENSOR OUT ALARM
ALARM HISTORY REPORT
51 [
SENSOR ALARM ALARM HISTORY REPORT
0 1:87 - - - -- SENSOR ALARM - - - -- PLLD SHUTDOWN ALARM L22:DISP 7 -8 ANNAUG27, 2013 11:36 AM ANNULAR SPACE
FUEL ALARM
GROSS LINE FAIL
AUG 27. 2013 10:30 AM
AUG 27. 2013 11:36 AM SENSOR OUT ALARM
AUG 27. 2013 10:16 AM
PLLD SHUTDOWN ALARM FUEL ALARMAUG27. 2013 10:16 AM AUG 27, 2012 2:59 PM
PLLD SHUTDOWN ALARM
AUG 27, 2013 10:14 AM
PLLD SHUTDOWN ALARM
AUG 27, 2013 10:14 AM
ALARM HISTORY REPORT PLLD SHUTDOWN ALARM
AUG 27, 2013 10:13 Aft
END
SENSOR ALARM -
AUG 27, 2013 10:12 AM SENSOR ALARM - - - --
0- 3:UIESEL PLLD SHUTDOWN ALARMPLLDSHUTDOWNALARMAUG27, 2013 10:12 AM
FUEL ALARM
AUG 27, 2013 11 :40 AM
AUG 27. 2013 10:30 AM
SENSOR OUT ALARM
PLLD SHUTDOWN ALARM AUG 27. 2013 10:16 AM
GROSS LINE FAIL AUGD27H 2O1133N10:1100 AMAUG27, 2013 11:40 AM
PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARMAUG27. ALARM HISTORY REPORT
AUG 27. 2013 10:16 AM 2013 10:07 AM
SENSOR ALARM - - - --
PLLD SHUTDOWN ALARM DISPEINSER9PANPLLDSHUTDOWNALARMAUG27, AUG 27. 2013 9:58 AM SENSOR OUT ALARM201310:14 API AUG 27. 2013 10:16 AM
PLLD SHUTDOWN ALARM ALARM HISTORY REPORT FUEL ALARM
AUG 27. 2013 10:13 AM SENSOR ALARM - - - --
AUG 27, 2013 10:13 AM
0 2:91 SENSOR OUT ALARM
PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM AUG 27. 2012 2:58 PM
AUG 27. 2013 10:03 AM AUG 27. 2013 11:38 AM
PLLD SHUTDOWN ALARM GROSS LINE FAIL
AUG 27. 2013 10.01 AM AUG 27. 2013 11:38 AM
PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM
AUG 27. 2012 2:58 PM AUG 27, 2013 10 :16 AM
x x x x END * x X w
PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM
AUG 27, 2012 2:39 PM AUG 27. 2013 10:14 AM
PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM
AUG 27, 2012 2:37 PM AUG 27, 2013 10:14 AM
PLLD SHUTDOWN ALARM
AUG 27, 2013 10:13 AM
ALARM HISTORY REPORT
PLLD SHUTDOWN ALARM
AUG 27, 2013 10:12 AM SENSOR ALARM - - - --
L24:DISP 9 -10 ANN
ANNULAR SPACE
PLLD SHUTDOWN ALARM FUEL ALARM
AUG 27, 2013 10:10 AM AUG 27. 2013 10:30 AM
SENSOR OUT ALARM
PLLD SHUTDOWN ALARM AUG 27. 2013 10:16 AM
AUG 27. 2013 10:05 AM QFNRAT? Al T nr nnne
ALARM HISTORY REPORT
SMARTSENSOR ALARM --
s 7:DIESEL -91 TANK ANN
HIGH LIQUID ALARM
AUG 27, 2013 11:07 AM
NO VACUUM ALARM
AUG 27. 2013 11:01 AM
NO VACUUM ALARM
f AUG 27. 2013 10:51 AM
x x* x END x x x x x
ALARM HISTORY REPORT
SMARTSENSOR ALARM --
s B:DIESEL PROD
HIGH LIQUID ALARM
AUG 27. 2013 10:52'AM
NO VACUUM ALARM
AUG 27. 2013 10:52 AM
VACUUM WARNING
AUG 27. 2012 5:05 PM
x x x ** END x x* x*
ALARM HISTORY REPORT
SMARTSENSOR ALARM --
s 9:DIESEL VENT
HIGH LIQUID ALARM
AUG 27. 2013 10:52 AM
NO VACUUM ALARM
AUG 27. 2013 10:51 AM
ALARM HISTORY REPORT
SMARTSENSOR ALARM --
s 4:87 -PROD
HIGH LIQUID ALARM
AUG 27,-2013 10:48 AM
NO VACUUM ALARM
AUG 27, 2013 10:46 AM
COMMUNICATION ALARM
AUG 27. 2012 5:32 PM
X x* x x END ** x* x
ALARM HISTORY REPORT
SMARTSENSOR ALARM --
s 5:91 VENT
HIGH LIQUID ALARM
AUG 27. 2013 10:55 AM
NO VACUUM ALARM
AUG 27, 2013 10:55 AM
xxx *x END xxx *x
ALARM HISTORY REPORT
SMARTSENSOR ALARM --
s 6:91 PROD
NO VACUUM ALARM
AUG 27. 2013 10:55 AM
HIGH LIQUID ALARM
AUG 27, 2013 10:55 AM
VACUUM WARNING
AUG 27. 2012 5:05 PM
ALARM HISTORY REPORT
SMARTSENSOR ALARM --
s 1:87 TANK ANN
HIGH LIQUID ALARM
AUG 27. 2013 11:00'AM
NO VACUUM ALARM
AUG 27, 2013 10:58 AM
NO VACUUM ALARM
AUG 27. 2013 10:47 AM
X x x* x END * x* x x
ALARM HISTORY REPORT
SMARTSENSOR ALARM --
s 2:87 VENT
HIGH LIQUID ALARM
AUG 27, 2013 10:48 AM
NO VACUUM ALARM
AUG 27, 2013 10:47 AM
COMMUNICATION ALARM
AUG 27, 20I2 5:29 PM
xxxx END 9xx *x
ALARM HISTORY REPORT
SMARTSENSOR ALARM --
s 3:87-91 VAPOR
HIGH LIQUID ALARM
AUG 27, 2013 10:49 AM
NO VACUUM ALARM
AUG 27, 2013 10:46 AM
7t ty
MONITOR CERT. FAILURE REPORT
SITE NAME: STOCKDALE FOODMART DATE: 8/27/13
ADDRESS: 5321 STOCKDALE HWY TECHNICIAN: RICHARD MASON
CITY: BAKERSFIELD SIGNATURE: fz VN---
REPAIRS:
91 SPILL BUCKET FAILED LAKE TEST - O -RING WAS TORN. I REPLACED
AND RE- TESTED - PASSED
PARTS INSTALLED:
I- PHIL -TITE SHUT -OFF COLLAR 0 -RING
THE ABOVE NAMED PERSON TAKES FULL RESPONSIBILITY OF NOTIFYING
THE APPROPRIATE PARTY TO HAVE CORRECTIVE ACTION TAKEN TO REPAIR
THE ABOVE LISTED PROBLEMS AND NOTIFYING RICH ENVIRONMANTAL FOR
ANY NEEDED RETESTING. THIS ALSO RELEASES RICH ENVIRONMENTAL OF
ANY FINES OR PENALTIES OCCURING FROM NON - COMPLIANCE.
A COPY OF THIS DOCUMENT HAS BEEN LEFT ON -SITE FOR YOUR
CONVIENENCE.
BAKERSFIELD CITY FIRE DEPARTMENT — INSPECTION RECORD
Post this Card at the Job Site and DO NOT Remove for Duration of Work
Inspection Request Phon6 No. (661) 326 -3979
UST NEW INSTALL
DESCRIPTION DATE SIGNATURE
BACKFILL
PRIMARY PIPE
SECONDARY PIPE
SECONDARY CONTAINMENT
SENSORS
AUTHORIZATION FOR FUEL
ELECTRICAL SEAK -OFF
TANKlESTING- -_ - - =1
UST REMOVAL
DESCRIPTION DATE SIGNATURE
AST NEW INSTALL
DESCRIPTION DATE SIGNATURE
MODIFICATIONS MINOR / MAJOR
AST REMOVAL
DESCRIPTION DATE SIGNATURE
EVR UPGRADE
PIP- 01 ANY SYSTEM,
ALL USTAND /ORAST'SYSTEMS SHALL BE
IN,STAL-COMPLETE AND ACCEPTED BY
MISC. ACTIVITY I sTHE BAKERSFIELD CITY PlRt DEPARTMENT.
FIRE;DEPARTMENT- (FINAL)_ , "-
REMARKS:
BUILDING ADDRESS: —3 "d -e
JOB DESCRIPTION: 6CCUPANCY TYPE:
OWNER: S v L d d,v PERMIT NO. 13y
CONTRACTOR: PHONE -# 2—
FD 1743
UNDERGROUND STORAGE TANKS
APPLICATION
TO PERFORM ELD /LINE TESTING/
SB989 SECONDARY CONTAINMENT
TESTING/TANK TIGHTNESS TEST AND
FUEL MONITORING CERTIFICATION
Please note that these are separate
Individual tests and will be charged per
separate type test accordingly.)
PERMIT #
ENHANCED LEAK DETECTION
TANK TIGHTNESS
Amrzz
lRL
ARrr r
BAKERSFIELD FIRE DEPARTMENT
Prevention Services
Q10( l-k 5-mr- ET
Bakerstield, CA 93301
Phone: 661-326-3979 • Fax: 661-852-2171
Page 1 of 1
LINE TESTING SB-989 SECONDARY CONTAINMENT
TUEL MONITORING CERTIFICATION
SITE INFORMATION :.
FACILITY AME 8 PH F CANT PERSON
tan
ADDRESS
OWNER NAME
OPERATOR NAME PERMIT TO OPERATE #
OF TANKS TO BE TESTED: IS PIPING GOING TO BE TESTED? YES NO
TANK VOLUME CONTENTS
l
TANK TESTING;COINPANY..
TESTING COMPANY Tsi,F—s
NAME a PHONE # OF CONTACT PERSON
MAILING ADDRESS
rjlay3 ook -S C.T. - F A K+F2SFIE.t -D C °13303
NAME & PHO OF TESTER R SPECIAL INSPECTOR CERTIFICATION #
0 eso
DATE & TIME TEST TO BE CONDUCTE ^
IG
ICC # TEST METHOD
APPLICANT SIGNATU DATE
IS APPLICATION BECOMES A PERMIT WHEN APPROVED
APPROVED BY DATE
FD2095 (Rev 03/08)
BILLING & PERMIT STATEMENT
PERMIT NO.:
B 13 R S F I D
F/RB
ARrr r
BAKERSFIELD FIRE DEPT.
Prevention Services
1600 Truxtun Ave Ste 401
Bakersfield CA 93301
Tel.: (661) 326 -3979 • Fax: (661) 852 -2171
FD 2021 (Rev. 06/07)
1 - ORIGINAL WHITE (to Treasury) 1- YELLOW (to File) 1 -PINK (to Customer)
SITE INFORMATION
LOCATION OF PROJECT PROPERTY OWNER
STARTING DATE COMPLETIO
LA
NAM
PROJECT NAME ADDRE PHONE NO.
PROJECTADDRESS C STATE ZIP CODE
INFORMATION
CONTRACTOR NAME CA LICENSE NO. TYPE OF LICENSE. EXPIRATION DATE
J e30
PHONE NO.
CONTRACTOR COMPANY NAME
i= 'E. v
FAX NA.
8O
ADDRESS
5U L4
CITY
WORK
ZIPL.we
All permits must be reviewed, stamped, and approved PRIOR TO BEGINNING ON THAT PROJECT. •
Alarms - New & Modifications - (Minimum Charge) $280.00 , •
98
Over 10,000 Sq. FL Sq. Ft. x.028 = Permit fee 84
98
11 Sprinklers - New & Modifications - (Minimum Charge) 280.00 84
98
Over 10,000 Sq. Ft. Sq. Ft. x.028 = Permit fee 98
Minor Sprinkler Modifications (< 10 heads) 96.00 [Inspection Only] 84
98
Commercial Hoods — New & Modifications 470.00 84
98
Additional Hoods 58.00 B4
98
1:1 Spray Booths - New & Modifications 470.00 84
98
Aboveground Storage Tanks (Installation/Insp. -1" Time) 180.00 82
Additional Tanks 96.00 82
Aboveground Storage Tanks (Removal/Inspection) 109.00 82
Underground Storage Tanks (InstallationAnspection) 878.00 (per tank) 82
Underground Storage Tanks (Modification) 878.00 (persite) 82
Underground Storage Tanks (Minor Modification) 167.00 82
Underground Storage Tanks (RemovA 573.00 (per tank) 84
Oilwell (Installation) 96.00 84
Mandated Leak Detection (Testing) / "uelMon Cert/SB989.
Note. $96.00 foreach type oftest /per scheduled
at the same time)
fi8 66{persite f d
g - S-113
82
Tents 96.00 (per tent) 84
Pyrotechnic - (Per event, Plus Insp. Fee @ $96 per hour) 96.00 + (5 hrs. min. standby fee /Inspeclion)=$576..00 84
After hours inspection fee 121.00 84
RE- INSPECTIONS) /FOLL OW -UP INSPECTION(S) 96.00 (per hour) 84
Portable LPG (Propane): NO. OF CAGES? _ 96.00 84
Explosive Storage 266.00 84
Copying & File Research (File Research Fee $50.00 per hr) 250 per page 84
Miscellaneous 84
FD 2021 (Rev. 06/07)
1 - ORIGINAL WHITE (to Treasury) 1- YELLOW (to File) 1 -PINK (to Customer)