Loading...
HomeMy WebLinkAboutINSPECTION 2019 5221 STINE RDFACILITY ADDRESS DATE `.".' I FEE 3 FACILITY NAME t� CITY, STATE, ZIP BUSINESS OWNER'S NAME AND ADDRESS""' _ MANAGER'S NAME PHI- . BILL TO: (IF DIFFERENT FROM ABOVE) NAME, ADDRESS CITY, STATE,:ZIP PH NO. OCC TYPE OCC LOAD NO. OF FLOORS OCC USE ' RISER DATE Wet /Dry Sprinkler System Type of Alarm System CONSTRUCTION TYPE HIGH RISE BLDG ❑ YES O `NO SQ /FT OF BLD CORRECT ALL VIOLATIONS VIOLATION REQUIREMENTS CHECKED,BELOW NO. 1 Remove and safely dispose. of all hazardous refuse and dry vegetation on the above premises (CL FC COMBUSTIBLE WASTE / DRY 304.1; VEGETATION, Provide non- combustible containers with tight fitting lids for the storage of combustible waste and 2 rubbish pending its safe disposal. (CFC 304.3.2) Note: applies to'containers over 40 gallons. Relocate combustible storage to provide "at least 3 feet clearance around motor fuse box %fire door (CFC. COMBUSTiscE.sTORA�E 3 605.3) 4 Relocate fire extinguishers) so that they will be in a conspicuous location,'hanging on brackets with.the top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9) EXTINGUISHERS 5 Provide and install (amount) ----- approved (type & size) "_ _ ___ __ __ __ ____ "portable fire CFC extinguisher to be immediately accessible for use in (area) ___ ----------------- ___------- TABLE 906:3) 6 Re- charge all fire extinguishers. .Fire extinguishers shall be serviced at least once each year, and /or, after each use, by a person having a valid license or certificate. (CFC 906.2) Provide and maintain "EXIT" sign(s) with, letters .6' or more inches in height over each .required exit; SIGN (door /window) to fire escape. (CFC 1011) Provide and maintain appropriate numbers on a contrasting background and visible from the street to. 8 indicate the correct address of the building. (CFC 50511) g Repair all (cracks /holes /openings) in plaster in ( location) ___�____________ ___ ___ ___ _ ___ _ _ __ _ __ FIRE DOORS.. Plastering shall return the surface to its original fire resistive condition. (CFC 703.1) FIRE SEPARATIONS 10 Remove/repair ' (item & location) ----------- ---------------------------------------------- be designed to close `by gravity, or by the action of a ,mechanical device, or by an Self- closing .doors shall approved smoke_ a,nd heat sensitive dev,ice.' Self- closing doors shall have no attachments capable of preventing the operation of the closing_ device. (CFC 703.2) 11 Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1031.1) EXITS 12 Provide a contrasting colored and permanently installed electric Light over or near required exit - (location) __ - - - -_ —_ to clearly indicate- it as an exit. (CFC 1008)',, _ Remove all storage and /or. other obstructions from fire escape landings and" stairways stair shafts. ; (Fire STORAGE 13. escapes /stai.r shafts are to be maintained free from obstructions at a.11 times.) .(.CFC 1"OQ3.6) Extension cords shall not be used in lieu of permanent approved wiring., Install additional approved ' 14 ELECTRICAL APPLIANCES electrical outlets where needed. (CFC 605:5) Remove multiple attachment cords from specific electrical: convenience outlet (one" plug per outlet) (CFC 605.4) OUTDOOR, BURNING 16 Recreational 'fires or open burning. CFC 307.1 FIREWORKS 12 Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.). OTHER 18 CORRECTION DATE Correct the violations noted above�Nby L D• r�.m< ¢` �?a�awa'rda;•`tTS�r+."�" C.F.C. CALIFORNIA�FIRE CODE ; CUSTOMER: � g ) (Please Print Name Legibly, Title) C B.C. CALIFORNIA BUILDING CODE Si nature 1 B M:C._ BAKERSFIELD MUNICIPAL CODE .■' c^ N.F.P NO.: N.F.P.A. NATIONAL FIRE PROTECTION INSPECTOR: ° - ASSOCIATION N.E.C: NATIONAL ELECTRIC CODE White — Customer/Original, Yellow - Station Copy Pink - Prevention Services FD 2022 (Rev. 10/2017)