CORRECT ALL VIOLATIONS VIOLATION
REQUIREMENTS
CHECKED,BELOW NO.
1
Remove and safely dispose. of all hazardous refuse and dry vegetation on the above premises (CL FC
COMBUSTIBLE WASTE / DRY
304.1;
VEGETATION,
Provide non- combustible containers with tight fitting lids for the storage of combustible waste and
2
rubbish pending its safe disposal. (CFC 304.3.2) Note: applies to'containers over 40 gallons.
Relocate combustible storage to provide "at least 3 feet clearance around motor fuse box %fire door (CFC.
COMBUSTiscE.sTORA�E
3
605.3)
4
Relocate fire extinguishers) so that they will be in a conspicuous location,'hanging on brackets with.the
top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9)
EXTINGUISHERS
5
Provide and install (amount) ----- approved (type & size) "_ _ ___ __ __ __ ____ "portable fire
CFC
extinguisher to be immediately accessible for use in (area) ___ ----------------- ___-------
TABLE 906:3)
6
Re- charge all fire extinguishers. .Fire extinguishers shall be serviced at least once each year, and /or,
after each use, by a person having a valid license or certificate. (CFC 906.2)
Provide and maintain "EXIT" sign(s) with, letters .6' or more inches in height over each .required exit;
SIGN
(door /window) to fire escape. (CFC 1011)
Provide and maintain appropriate numbers on a contrasting background and visible from the street to.
8
indicate the correct address of the building. (CFC 50511)
g
Repair all (cracks /holes /openings) in plaster in ( location) ___�____________ ___ ___ ___ _ ___ _ _ __ _ __
FIRE DOORS..
Plastering shall return the surface to its original fire resistive condition. (CFC 703.1)
FIRE SEPARATIONS
10
Remove/repair ' (item & location) ----------- ----------------------------------------------
be designed to close `by gravity, or by the action of a ,mechanical device, or by an
Self- closing .doors shall
approved smoke_ a,nd heat sensitive dev,ice.' Self- closing doors shall have no attachments capable of
preventing the operation of the closing_ device. (CFC 703.2)
11
Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1031.1)
EXITS
12
Provide a contrasting colored and permanently installed electric Light over or near required exit -
(location) __ - - - -_ —_ to clearly indicate- it as an exit. (CFC 1008)',, _
Remove all storage and /or. other obstructions from fire escape landings and" stairways stair shafts. ; (Fire
STORAGE 13.
escapes /stai.r shafts are to be maintained free from obstructions at a.11 times.) .(.CFC 1"OQ3.6)
Extension cords shall not be used in lieu of permanent approved wiring., Install additional approved '
14
ELECTRICAL APPLIANCES
electrical outlets where needed. (CFC 605:5)
Remove multiple attachment cords from specific electrical: convenience outlet (one" plug per outlet) (CFC
605.4)
OUTDOOR, BURNING 16
Recreational 'fires or open burning. CFC 307.1
FIREWORKS 12
Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.).
OTHER 18
CORRECTION DATE
Correct the violations noted above�Nby
L D•
r�.m< ¢` �?a�awa'rda;•`tTS�r+."�" C.F.C. CALIFORNIA�FIRE CODE ;
CUSTOMER:
� g ) (Please Print Name Legibly, Title) C B.C. CALIFORNIA BUILDING CODE
Si nature
1 B M:C._ BAKERSFIELD MUNICIPAL CODE
.■'
c^
N.F.P
NO.: N.F.P.A. NATIONAL FIRE PROTECTION
INSPECTOR: ° - ASSOCIATION
N.E.C: NATIONAL ELECTRIC CODE