Loading...
HomeMy WebLinkAbout4901 UNION AVENUE (5)SWRCB, January 2006 Spill Bucket Testing Report Form Thisform is intendedfor use by contractors performing annual testing of UST spill containment structures. The completed_form and printoutsfrom tests (ifapplicable), should he provided to thefacility owner /operatorfor submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: 4775 Chevron (North) I Date of Testing: 8/12/2011 Facility Address: 4901 South Union Avenue, Bakersfield, CA 93307 Facility Contact: Omero Garcia Phone: 661- 393 -7000 Date Local Agency Was Notified of Testing Name of Local Agency Inspector (rfpresent during testing): Ernie Medina 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Services, Inc. Technician Conducting Test: Bradley Seykora Credentials: X CSLB Contractor X iCC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s): CSLB #804904 ICC #81 1 1231 3. SPILL BUCKET TESTING INFORMATION Test Method Used: x Hydrostatic Vacuum Other Test Equipment Used: Lake Test Equipment Resolution: 0.0625' Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1 Regular/ Master 2 Super 3 4 Bucket Installation Type: Direct Bury 0 Contained in Sump Direct Bury 9 Contained in Sump Direct Bury Contained in Surnp Direct Bury Contained in Sum Bucket Diameter: 12.00" 12.00" Bucket Depth: 11.00- 11.001, Wait time between applying vacuum /water and start of test: 5 min. 5 min. Test Start Time (Ti): 11:45 A.M. 11:45 A.M. Initial Reading (Rj): 9.50" 9.00" Test End Time (TF): 12:45 P.M. 12:45 P.M. Final Reading (RF): 9.50" 9.00" Test Duration (TF — Tj): 1 hour I hour Change in Reading (RF - Ri): 0.00" 0.00" Pass /Fail Threshold or Criteria: 0.0625' 0.0625" Test Result: Pass Fail N Pass Fail Pass Fail Pass Fail Comments — (include information on repairs made prior to testing, and recommendedfollow -upforfailed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Techr Date: 8/12/2011 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. SWRCB, January 2006 Spill Bucket Testing Report Form This, form is intendedfor use by contractors performing annual testing ofUST spill containment structures. The completedform and printoutsfrom tests (fapplicable), should be provided to thefacility owner /operatorfor submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: #725 Fastrip # 19 (South) I Date of Testing: 8/12/2011 Facility Address: 4901 South Union Avenue, Bakersfield, CA 93307 Facility Contact: Omero Garcia Phone: 661- 393 -7000 Date Local Agency Was Notified of Testing: Name of Local Agency Inspector (ifpresent during testing): Ernie Medina 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST Services, Inc. Technician Conducting Test: Bradley Seykora Credentials: X CSLB Contractor X ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s): CSLB #804904 ICC #81 1 1231 3. SPILL BUCKET TESTING INFORMATION Test Method Used: x Hydrostatic Vacuum Other Test Equipment Used: Lake Test Equipment Resolution: 0.0625" Identify Spill Bucket (By Tank Number, Slored Product, etc.) 1 Diesel 2 3 4 Bucket Installation Type: Direct Bury x Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sum Bucket Diameter: 12.00" Bucket Depth: 11.25" Wait time between applying vacuum /water and start of test: 5 min. Test Start Time (Ti): 11:45 A.M. Initial Reading (Rj): 9.00" Test End Time (TA 12:45 P.M. Final Reading (RF): 9.00" Test Duration (TF — Tj): I hour Change in Reading (RF - Ri): 0.00" Pass /Fail Threshold or Criteria: 0.0625" Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Comments — (include information on repairs made prior to testing, and recommendedfollow -upforfailed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature: Date: 8/12/2011 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent.