Loading...
HomeMy WebLinkAbout4800 FAIRFAX ROAD (2)Spill Bucket Testing Report Form SWRCB, January 2006 Thisform is intended, for use by contractors performing annual testing ofUST spill containment structures. The completedform and printouts r om tests (ifapplicable), should be provided to thefacility ownerloperator.for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: Arco AM PM I Date of Testing: 7/1/2011 Facility Address: 4800 Fairfax Road, Bakersfield, CA 93306 Facility Contact: Alondra Hernandez I Phone: 661- 835 -8044 Date Local Agency Was Notified of Testing: 6/28/2011 Name of Local Agency Inspector (ifpresent during testing): Ernie Medina 2. TESTING CONTRACTOR INFORMATION Company Name: Confidence UST services, Inc. Technician Conducting Test: Kristopher Karns Credentials': x CSLB Contractor x ICC Service Tech. x SWRCB Tank Tester Other (Specify) License Number(s): #804904 #5264406 -UT #09 -1743 3. SPILL BUCKET TESTING INFORMATION Test Method Used: O Hydrostatic Vacuum Other Test Equipment Used:Lake Test Equipment Resolution: 0.0625" Identify Spill Bucket (lay Tank Number, Stored Product, etc. Super Bucket Installation Type: Direct Bury x Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sum Bucket Diameter: 12.00" Bucket Depth: 14.50" Wait time between applying vacuum /water and start of test: 5 Minutes Test Start Time (Ti): 12:10 PM Initial Reading (R,): 13.00" Test End Time (T,:): 1:10 PM Final Reading (R,:): 13.00" Test Duration (T,: — T,): I Hour Change in Reading (R,: - R,): 0.00" Pass /Fail Threshold or Criteria: 0,0625" Test Result: x Pass Fail Pass Fail Pass Fail Pass Fail Comments — (include information on repairs made prior to testing, and recommendedfollow -up for.failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING 1 herehy certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature: 4 iA4 Date 7/1//2011 State laws and regulations do not currently require testing to be perfonned by a qualified contractor. However, local requirements may be more stringent. G0 n a0F S T Invoice No.: 27214 Site: Arco AM PM 4800 Fairfax Road Bakersfield, CA 93306 Repairs Requested: Replace and Re -Test the Super Phil Tite Spill Bucket. Repairs completed: We replaced the Super Phil Tite Spill Bucket. Then ran an hour long Lake Test Which passed. Total time on site was two hours. Required Repairs, Still Pending: Technician Name: Kristopher Karns Signature: , A. Date: 7/11/2011