Loading...
HomeMy WebLinkAbout4101 CALLOWAY DRIVE (4)i Tanlanology 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451 -6334 Fax: (512) 459 -1459 BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES INSPECTOR CRAIG PERKINS 1501 TRUXTUN AVE. BAKERSFIELD, CA. 93301 Test Date: 05/23/2011 Order Number: 3183760 Dear Regulator, Date Printed and Mailed: 06/01/2011 Enclosed are the results of recent testing performed at the following facility: 7- ELEVEN #32241, MKT 2368 4101 CALLOWAY DRIVE BAKERSFIELD, CA. 93312 Testing performed: Healy Quarterly Inspection Healy Vapor /Liquid Sincerely, y/ Dawn Kohlmeyer Manager, Field Reporting 0 0as I , , w San Joaquin Valley HEALTHY AIR LIVING* we.'*.heaIIhI airIivIn;'. cwt AIR POLLUTION CONTROL DISTRICT Make one change for clean air! E.O. VR- 201/202 Vapor -to- Liquid (V /L) Volume Ratio Test Report Form Permit Number. 5- 3256 -1 -2 Test Company: TANKNOLOGY Tri- Tester Site Name: 7- ELEVEN #32241 Technician: EDWIN PINEDA Tri- Tester software version, if applicable (must be version 2.01 ) Site Address: 4101 CALLOWAY DR Certification Number Expiration Date C4: BAKERSFIELD Zip: 93312 District: SYV -0227 3/16/13 Date/Time ofTest: 05/23/11 12:30 Franklin Beal : 1620323702 01/24/13 TEST INFORMATION Gas volume meter i.e., Roots meter or Tri- Tester Tri- Tester Gas volume meter serial or identification number 0435683 Tri- Tester software version, if applicable (must be version 2.01 ) 2.96 & 2.01 & DR Calibration date for Gas volume meter must be within 180 days ofthe test 12/10/10 Gas volume meter correction factor, y meter 0•996 Pre -test leak check for Roots meter: itial pressure: 0 sec. pressure: Pre -test leak check for Tri- tester e- inflate in 30 sec. Yes ®No Post -test leak check for Roots meter: knitial pressure: 0 sec. pressure: Post -test leak check for Tri- tester Re-inflate in 30 sec. Yes ®No Nozzle Number Fuel Grade Nozzle Model & Serial No. Initial Dispenser Reading Final Dispenser Reading Total Gras gal.) Time sec) Dispensing Rate (gal.) Initial Meter Reading (W), Ve Final Meter Reading Uft Vf V/L Pass/Fail P/F) 1 87 M19080789 2.036 8.33 1.15 PASS 1 89 2.056 8.33 1.04 PASS 1 91 2.041 7.89 1.10 PASS 2 87 M32081111 2.048 9.04 0.99 PASS 2 89 2.050 926 1.02 PASS 2 91 2.044 9.04 0.96 PASS 3 87 M41100025 2.035 9.26 1.04 PASS 3 89 2.050 8.82 1.00 PASS I declare, under penalty ofperjury under the laws ofthe state ofCalifornia that based on information and beliefformed after reasonable inquiry, the statements and information provided in this document are true, accurate, and complete. s 0 7c' a 0 w 00 w 0 m 0 0ao 0 00 ii Si tore ofTechnician: Date: Fuel Grade Nozzle Model & Serial No. initial Dispenser Reading al. Gi Final Dispenser Reading Gr Total Gas Dispensed 1) Time sec) Dispensing Rate (gal.) Initial Meter Beading (ft), V, Final Meter Reading Yr V/L P 1 P/F) 3 91 2.036 8.52 0.96 PASS 4 87 M22080933 2.052 926 0.62 FAIL 4 87 2.033 937 0.67 FAIL 4 87 2.041 926 0.74 FAIL 4 87 M60100290 2.050 9.37 1.04 PASS 4 89 2.438 9.49 1.04 PASS 4 91 2.031 8.93 1.05 PASS S 87 M33082621 2.024 9.26 1.01 PASS 5 89 2.049 9.49 1.00 PASS 5 91 2.046 8.93 1.01 PASS 6 87 1607236 2.039 8.72 0.96 PASS 6 89 2.043 9.04 0.98 PASS 6 91 2.038 8.82 0.99 PASS 7 87 1607242 2.049 8.33 1.14 PASS 7 89 2.045 8.62 1.02 PASS 7 91 2.048 8.82 1.09 PASS 8 87 M14100016 2.050 9.04 1.02 PASS g 89 2.045 9.26 I.00 PASS 8 91 2.061 8.93 1.00 PASS NOTE: The V/L ratio shalt be 0.95 to 1.15, measured at a flow rate between 6.0 -10.0 gpm. Any fueting point whose V/L ratio is determined to be at or below 0.80 shall be deemed defective and removed from service, Ideclare, under penalty ofperjury under the laws ofthe state ofCalifornia that based on information and beliefformed after reasonable inquiry, the statements and Information provided in this document are true, accurate, and complete. Signature ofTechnician: Date: Nozzle Number Fuel Grade Nozzle Model & Serial No. initial Dispenser Reading al. Gi Final Dispenser Reading Gr Total Gas Dispensed 1) Time sec) Dispensing Rate (gal.) Initial Meter Beading (ft), V, Final Meter Reading Yr V/L P 1 P/F) 3 91 2.036 8.52 0.96 PASS 4 87 M22080933 2.052 926 0.62 FAIL 4 87 2.033 937 0.67 FAIL 4 87 2.041 926 0.74 FAIL 4 87 M60100290 2.050 9.37 1.04 PASS 4 89 2.438 9.49 1.04 PASS 4 91 2.031 8.93 1.05 PASS S 87 M33082621 2.024 9.26 1.01 PASS 5 89 2.049 9.49 1.00 PASS 5 91 2.046 8.93 1.01 PASS 6 87 1607236 2.039 8.72 0.96 PASS 6 89 2.043 9.04 0.98 PASS 6 91 2.038 8.82 0.99 PASS 7 87 1607242 2.049 8.33 1.14 PASS 7 89 2.045 8.62 1.02 PASS 7 91 2.048 8.82 1.09 PASS 8 87 M14100016 2.050 9.04 1.02 PASS g 89 2.045 9.26 I.00 PASS 8 91 2.061 8.93 1.00 PASS w w rn 0 I 0 0ao 5 0 00 z b x c 00 Yc S' in VR -201 -C and VR -202 -C - Quarterly Inspection and Testing Checklist Checklist results may be used to assist with filling out GDF maintenance log. Date: Page 1 of 'Z Dispenser Number Unihose or Fuel Grade circle one) Weekly Inspection Complete circle one) VP1000 Inspection circle one) Product Dispensing Rate (gallons per minute) Fuel Grade Tested circle one) Clean Air Separator Configuration see figure on back) 1 8 87 89 91 Other No qbs Fail 3S gpm 89 91 Other_ Valve Circle One Unihose 87 89 91 Other No rMs. Fail 3,3S gpm 8700 91 Other A d5an Closed Unihose 87 89 91 Other No 4eps Fail Sq gpm 87 89 P3 Other_ B Open Z 142 e 87 89 91 Other T No e 2a Fail Z(.i gpm D89 89 91 Other C Open s EM Z Unihose 87 89 91 Other No 9s Fail gpm 87 0 91 Other D Open dGzw Z- Unihose 87 89 91 Other No It Fail jol.l gpm 87 89 Other 3 11 a 87 89 91 Other 66 No 4a a Fail gpm 89 91 Other Plug Circle One 3 Unihose 87 89 91 Other fl No Fail Z gpm 87 91 Other E tf d Missing 3 Unihose 87 89 91 Other ` C,39 No d1ft Fail' 3.SZ gpm 87 89 L9) Other F 01ad Missing f C125W 87 89 91 Other _ No f2p Fail 3 gpm Q7 89 91 Other Unihose 87 89 91 Other _ No 13h Fail L6 gpm 87 8 91 Other Unihose 87 89 91 Other No 6& Fail 8Jq - gpm 87 89(o Other ni 87 89 91 Other 61, No 450s Fail 111-4- gpm P 89 91 Other S Urtihose 87 89 91 Other No 112s Fail J,L)q gpm 87 (991 Other s Unihose 87 89 91 Other _ Cds No s Fail 8q3; gpm 87 89 Other Unihose 87 89 91 Other Yes No Pass Fail gpm 87 89 91 Other 2. ao 0 00 z 0 0 b m b 00 S, CD C xm 00 VR -201 -C and VR -202 -C - Quarterly Inspection and Vesting Checklist Checklist results may be used to assist with filling out GDF maintenance log. Date: L3 Page 1, of Dispenser Number Unihose or Fuel Grade circle one) Weekly Inspection Complete circle one) VP1000 Inspection circle one) Product Dispensing Rate (gallons per minute) Fuel Grade Tested circle one) Clean Air Separator Configuration see figure on back} dRbse 87 89 91 Other _ IN No 2TsA Fail gpm 89 91 Other Valve Circle One Unihose 87 89 91 Other No Fail a gpm 87(7b 91 Other A men Closed 6 Unihose 87 89 91 Other No s Fail gpm 87 890 Other B Open cawl 4gbote 87 89 91 Other No a s Fail 3 gpm n 89 91 Other C Open aid Unihose 87 89 91 Other_ Ps No Oa s Fail Z gpm 87(D 91 Other D Open tad Unihose 87 89 91 Other as No s Fail e& gpm 87 89 Other V@R4e 87 89 91 Other No Ios Fail q.dliA gpm 89 91 OtFier Plug Circle One Unihose 87 89 91 Other No s Fail JU gpm 87 1 other E 90Pd Missing Unihose 87 89 91 Other ` n$ No Fail' gpm 87 89 Other F 199-MW Missing Unihose 87 89 91 Other Yes No Pass Fail gpm 87 89 91 Other Unihose 87 89 91 Other Yes No Pass Fail gpm 87 89 91 Other Unihose 87 89 91 Other Yes No Pass Fail gpm 87 89 91 Other Unihose 87 89 91 Other Yes No Pass Fail gpm 87 89 91 Other Urtihose 87 89 91 Other Yes No Pass Fail gpm 87 89 91 Other Unihose 87 89 91 Other Yes No Pass Fail gpm 87 89 91 Other Unihose 87 89 91 Other Yes No Pass Fail gpm 87 89 91 Other 0 0 0 00 Z 0d n tT'1 3 CAD CD 00 a 5' C c xm 00 r_ 0 O aco VR -201 -C and VR -202 -C - Weekly Inspection and Testing Checklist Checklist results may be used to assist with filling out GDF maintenance log. Date: Page. of f Dispenser Number Unihose or Fuel Grade circle one) Nozzle Inspection circle one) Hose inspection circle one) Breakaway Inspection circle one) VP1000 Vacuum Pump Normal Operation circle one) a 87 89 91 Other sus Fail Fail Fail f No m a 89 91 Other s Fail Fail Fail No 3 td>ie 87 89 91 Other I,P. ss Fail Fail s Fail No e 87 89 91 Other _ 3s Faii Fail Fail No 5 t e 87 89 91 Other s Fail Fail Fail No G t F 6e 7 89 1_ Other s Fail Fail a Fail No e 87 89 91 Other _ s Fail Fail s Fail No nih 87 89 91 Other ss Fail Fail Fail No Unihose 87 89 91 Other Pass Fail Pass Fail Pass Fail Yes No Unihose 87 89 91 Other Pass Fail Pass Fail Pass Fail Yes No Unihose 87 89 91 Other Pass Fail Pass Fait Pass Fail fS No Unihose 87 89 91 Other Pass Fail Pass Fail Pass Fait Yes N Unihose 87 89 91 Other Pass Fail Pass Fail Pass Fail Yes No ON Unihose 87 89 91 Other Pass Fail Pass Fail Pass Fail Yes No Unihose 87 89 91 Other Pass Fail Pass Fail Pass Fail Yes No Unihose 87 89 91 Other Pass Fail Pass Fail Pass Fail Yes No eqlm 0 N lA L v p x w i pm d r_ 0 O aco VR -201 -C and VR -202 -C - Weekly Inspection and Testing Checklist Checklist results may be used to assist with filling out GDF maintenance log. Date: Page. of f Dispenser Number Unihose or Fuel Grade circle one) Nozzle Inspection circle one) Hose inspection circle one) Breakaway Inspection circle one) VP1000 Vacuum Pump Normal Operation circle one) a 87 89 91 Other sus Fail Fail Fail f No 87 89 91 Other s Fail Fail Fail No 3 td>ie 87 89 91 Other I,P. ss Fail Fail s Fail No e 87 89 91 Other _ 3s Faii Fail Fail No 5 t e 87 89 91 Other s Fail Fail Fail No G t F 6e 7 89 91 Other s Fail Fail a Fail No e 87 89 91 Other _ s Fail Fail s Fail No nih 87 89 91 Other ss Fail Fail Fail No Unihose 87 89 91 Other Pass Fail Pass Fail Pass Fail Yes No Unihose 87 89 91 Other Pass Fail Pass Fail Pass Fail Yes No Unihose 87 89 91 Other Pass Fail Pass Fait Pass Fail Yes No Unihose 87 89 91 Other Pass Fail Pass Fail Pass Fait Yes No Unihose 87 89 91 Other Pass Fail Pass Fail Pass Fail Yes No Unihose 87 89 91 Other Pass Fail Pass Fail Pass Fail Yes No Unihose 87 89 91 Other Pass Fail Pass Fail Pass Fail Yes No Unihose 87 89 91 Other Pass Fail Pass Fail Pass Fail Yes No r_ 0 O aco SITE DIAGRAM Tan 8501 N MOPAC EXPRESSWAY, SUITE 400 AUSTIN, TEXAS 78759 512) 451 -6334 FAX (512) 459 -1459 TEST DATE: 05/23/11 WORK ORDER NUMBER3183760 CLIENT: 7 -ELEVEN, INC. SITE:7- ELEVEN #32241, MKT 2368 0 W VPH site. - S- 0 U) S .0 1 , 3,14 AIR/ L -11 S- 97 H2O9,10 VENT P # L -3 ,11 PAN S L -6 OL 8 CAS #2 # 5 #8 5L ' ICE L -1 '9 L -4 7 2 7 -11 #32241 #3 4101 Calloway Dr. N Bakersfield, CA 93312 E 661.587.8826 ESOTLSAPCD #S- 3256 -1 -2 Printed 06101/2011 07:20 MTUTTLE