Loading...
HomeMy WebLinkAbout215 21ST STREET (8)Tan nol® 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451 -6334 Fax: (512) 459-1459 BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES INSPECTOR CRAIG PERKINS 1501 TRUXTUN AVE. BAKERSFIELD, CA 93301 Test Date: 5/31/2012 Order Number: 3402244 i Date Printed and Mailed: 6/21/2012 i , Dear Regulator, Enclosed are the results of recent testing performed at the followin g PEPSI COLA #3040 ; 1 215 EAST 21ST STREET BAKERSFIELD, CA 93305 Testing performed: ATG IMPACT. VALVE LEAK DETECTOR SPILL BUCKET TEST Sincerely, Y a srrY'- Dawn Kohlmeyer Manager, Field Reporting I t: i 4 i it. • b: rf ' T, I I TAnknology Work Order: 3402244 Site Name / ID: PEPSI COLA #304 Address: 215 EAST 21ST ST City: BAKERSFIELD LDT 5000 Field Test Apparatus Line Leak Detector Test Date: 5/31/2012 i Page 1 of 1 r State: CA Zip: 93305 I Tank ID 1 Product Diesel Product Line 1 Tested From 1 Existing /New Existing Mechanical /Electronic Mechanical Manufacturer /Model Red Jacket FX1D Serial No. 308082873 Pump Operating Pressure (psi) 28.00 Calibrated Leak (mllmin) 189.0 Calibrated Leak (gph) 3.00 Holding PSI NIA for Electronic Lo's 11.00 Resiliency (ml) N/A for Electronic Lo's 50.00 Metering PSI N /A for Electronic Lo's Opening Time (sec) N /A for Electronic LD's 2 est Results Pass Technician Name: Edgar Sotomayor Certification #: 1950 •" Technician Signature: Environmental Compliance for Petroleum Systems 2010Tankndogy Inc., Austin, TX. All rights reserved, tankndogy.com Ir i Tanknology Impact Valve Inspection Impact Valve Operational Inspection Work Order: X402244 Date: 5/31/2012 Site Name /ID: PEPSI COLA #3040 Address: 215 EAST 21ST STREET City: 13AKERSFIELD State: y i Appendix VI Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http.: / /www.swrcb.Ca.gov.) MONITORING SYSTEM CERTIFICATION For Use By All Jurisdictions Within the State of California Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner /operator. The owner /operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. { A. General Information I 4 . Facility Name: PEPSI COLA #3040 Bldg. No.: 3040'" { Site Address: 215 EAST 21ST STREET City: BAKERSFIELD Zip: 93305 Facility Contact Person: CASEY BLAIR Contact Phone No.: 201 -6963 Make /Model of Monitoring System: Veeder Root Simplicity Date of Tiist14servicing: 5/31/2012 B. Inventory of Equipment Tested /Certified { ChPrk tha nonronriatn hmrac to Indiratn cnnrlflr anidnmant Incnartadloa 1~1- Tank ID: Tl: DIESEL FUEL - Diesel Tank ID: R, In -Tank Gauging Probe. Model: Mag r In -Tank Gauging Probe. Model: r` Annular Space or Vault Sensor. Model: 302 rl Annular Space or Vault Sensor. Model: i f Piping Sump / Trench Sensor(s). Model: 352 r Piping Sump / Trench Sensor(s). Model: l' r FIII Sump Sensor(s), Model: r Fill Sump Sensor(s). Model: I Mechanical Line Leak Detector. Model: Red Jacket FX1DV r Mechanical Line Leak Detector. Model: Electronic Line Leak Detector. _Model: r Electronic Line Leak Detector. Model: i r Tank Overfill / High -Level Sensor: Model: Flapper r Tank Overfill / High -Level Sensor. Model: Other (specify ui ment type and model in Section E on Page 2). ri Other (soecify equipment and model in Sectlon E on Pa e 2). Tank ID: j Tank ID: r In -Tank Gauging Probe. Model: r In -Tank Gauging Probe. Model: I r Annular Space or Vault Sensor. Model: N Annular Space or Vault Sensor. Model: ! Piping Sump / Trench Sensor(s). Model: 17! Piping Sump / Trench Sensor(s). Model: { Y' r FIII Sump Sensor(s), Model: Fill Sump Sensor(s). Model: Mechanical Line Leak Detector. Model r Mechanical Line Leak Detector. Model: r Electronic Line Leak Detector. -Model: r Electronic Line Leak Detector, Model: { Tank Overfill / High -Level Sensor. Model Tank Overfill /High -Level Sensor. Model: I Other (specify equipment and model in Section E on Page 2). rj Other (specify equipment a and model in Section on Pa e 2). Dispenser 1/2 Dispenser ID: ID: {. Dispenser Containment Sensor(s). Model: r Dispenser Containment Sensor(s).;Model: R Shear Valve(s). Shear Valve(s). I P7 Dispenser Containment Float(s) and Chaln(s). Dispenser Containment Float(s) and Chain(s). Dispenser Dispenser i4. ID: ID: r Dispenser Containment Sensor(s). Model: r Dispenser Containment Sensor(s). Model: F Shear Valve(s), r Shear Valve(s). r Dispenser Containment Floats and Chain(s ). Dis enser Containment Floats and Chain(s). Dispenser Dispenser ID: ID: '} T7. Dispenser Containment Sensor(s). Model: r Dispenser Containment Sensor(s). Model: r Shear Valve(s). rl Shear Valve(s). r Dispenser Containment Float(s) and Chain(s). r Dispenser Containment Float(s) and Chain's). r the raclllty contains more tanks or dispensers, copy this form. include information for every tank and dispenser at the facility. ? - C. Certification - I certify that the equipment identified in this document was inspected /serviced in accordance with the,manufactu ers' uidelines'' Attached to this Certification is Information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing,the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all tha' apply) :.r System set- up r Alarm history report Technician Name (print): Edgar Sotomayor Certification No.: 836950' Testing Company Name: Tanknology Testing Company Address: 11000 N. MoPac Expressway Suite 500 Signature: License. No.: 743160 Class 'A' " Phone No.: (800) 800-4633 E Monitoring System Certification Page 1 of i k D. Results of Testing /Servicing i Software Version Installed: 119.05 Complete the following checklist: f` Yes C No* Is the audible alarm operational? i, f i is Yes No* Is the visual alarm operational? C Yes No* Were all sensors visually Inspected, functionally tested, and confirmed operational? JJ i. is Yes t? No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not Interfere with Monitoring System Certification Page 2 of 3 12/07 i their proper operation? ' I r Yes 7 No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operatlorial? 4, ; t: r N/A f i G Yes r No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring Ii C. N/A system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors Initiate positive shut -down? (Check all that apply) P Sump/Trench Sensors; r Dispenser Containment Sensors. j Did you confirm positive shut -down due to leaks and sensor failure /disconnection? (o Yes; r No r Yes r No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) andoperating.properly? IfrN/A so at what percent of tank capacity does the alarm trigger? % fYes* 0. No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer name and model for all replacement parts in Section E below, t Yes* t No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply),: F Product; r Water. If yes, describe causes in Section E below. i IT-' Yes 0y, No* Was monitoring system set -up reviewed to ensure proper settings? Attach set up reports, If applicable r Yes i > No* Is all monitoring equipment operational per manufacturer's specifications? in section r Deiow, descnoe now and when these deticiencies were or will be corrected. . E. Comments: i, f i I removed a small amount of rain water from the STP /piping sump. I ' 4 JJ i. Monitoring System Certification Page 2 of 3 12/07 i 4, ; t: t Ii t i F. In -Tank Gauging / SIR Equipment: r 1 Check this box if tank gauging is used only for Inventory control. r' Check this box if no tank gauging or SIR equipment is Installed. This section must be completed if In -tank gauging equipment Is used to perform leak detection monitoring. ; f I Complete the following checklist: Yes r No* Has all Input wiring been Inspected for proper entry and termination, Including testing for ground fauits7 Yes rO No* Were all tank gauging probes visually inspected for damage and residue buildup? r Yes r No* Was accuracy of system product level readings tested? r Yes M No* Was accuracy of system water level readings tested? r Yes 00 No* Were all probes reinstalled properly?.. r Yes Ir No* Were all items on the equipment manufacturer ?s maintenance checklist completed? I in the bection H, Deiow, aescrIbe now and when these deficiencies were or will be corrected. G. Line Leak Detectors (LLD): r Check this box If LLDs are not Installed. i. k Complete the following checklist: r Yes r No* For equipment start-up or annual equipment certification was a leak simulated to verify LLD performance? (Check all that M, N/A apply) Simulated leak rate: WA g.p.h.; r 0.1 g.p.h; 0.2 g.p.h. y I r Yes C, No* Were all LLDs confirmed operational and accurate within regulatory requirements? I Yes r No* Was the testing apparatus properly calibrated? r Yes r No* For mechanical LLDs, does the LLD restrict product Flow if it detects a leak? ry N/A r Yes G"' No* For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? ? N/A Yes OP No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system'is °disabled or. disconnected? r Yes r No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or.falls a test? 7- N/A r Yes r= No* For electronic LLDs, have all accessible wiring connections been visually Inspected? N/A j r Yes r No* Were all Items on the equipment manufacturer's maintenance checklist completed? in Lne Jeuiun r1, Deiow, oescrioe now ano when Cnese aehaencies were or Wnl be correctea. 1 i f SWRCB, January 2002 Page 1 of 1 Secondary Containment Testing Report Form This form is intendedfor use by contractors performing periodic testing of UST secondary containment systems. Us'e the appropriate pages ofthis form to report resultsfor all components tested. The completedform, written test procedures,. and printoutsfrom tests ifapplicable), should be provided to thefacility owner /operator for submittal to the local regulatory agency.` 1. FACTT.TTV TNFnRMATTnN Facility Name: PEPSI COLA #3040 Date of Testing: 5/31 /2012 1 .. Facility Address: 215 EAST 21ST STREET , BAKERSFrELD, CA 93305 Facility Contact: CASEY BLAIR Phone: 201 -6963 Date Local Agency Was Notified of Testing: 5/22/2012 Name ofLocal Agency Inspector (if present during testing): Ernie Medina j 2. TF,STTNC. CONTRACTOR INFORMATION Company Name: TANKNOLOGY INC. Technician Conducting Test: Edgar Sotomayor j Credentials: CSLB Licensed Contractor r SWRCB Licensed Tank Tester License Type: A ILicense Number: 743160 M ._ ..... -, _......., ._. -., w .. - .. .....,. , Manufacturer Training Manufacturer Component(s) Date Training l' Expires OPW VR 102 2/21/2014° l f: 3. SUMMARY OF TEST RESULTS I Not Repair Not RepairsComponentPassFailComponentPass. Fail r!::? Tested Made ; .:, Tested Made Spill Box TI: DIESEL FUEL diesel fill j( F If hydrostatic testing was performed, describe what was done with the water after completion of tests: I, CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING , ., z .:. a To the best ofmy knowledge, the facts stated in this document are accurate and infull compliance with legal requirements Technician's Signature: Date: 5/31/2012 WO: 3402244 iti i 7 Page 1 of 1 I SPILL /OVERFILL CONTAINMENT BOXES Facility is Not Equipped With Fill Riser Containment Sumps rJ Fill Riser Containment Sumps are Present, but were Not Tested r Test Method Developed By: r Spill Bucket Manufactured, Industry Standard 0 Professional "Engineer t' Other (Specify): i Test Method Used By: r7 Pressure r Vacuum C Hydrostatic -: l" Other (Specify): Test Equipment Used: LAKE TE T Equipment Resolution: 0.062 in. Offi 1, , r4. 4 fix= si 5`III Box # V t z r Tank TS DIE$EL FUEL Dlesel v SpIII Boxy # 9 RSpIII7Box #i Er k F Spill Bon #7 S FIII Direct+ W0: 3402244 broa Bucket Diameter: 11.00 a:, Irj i I7 i Bucket Depth: 12.00 I Wait time between I applying pressure /vacuum /water 10 min min min min and starting test I Test Start Time: 09:00:00 Initial Reading ,>Sy. 5.50 In. i Test End Time: 10:00:00 Final Reading oyl: 5.50 In. i ' ." . Test Duration: 1 hr Change in Reading rAfyl: 0.00 In, i Pass /Fall Threshold or Criteria: 0.00 Pas E w. G Comments ? (include information on repairs made prior to testing, and recommended follow- up 'for fpiledtests) '. i i t 5.. W0: 3402244 tr a:, Irj i I7 Site DiagramUnknology' This site diagram is for reference only and is not drawn to scale) Work Order: 3402244 Date: 5/31/2012 Site ID / Name: 3040 /PEPSI COLA #3040 Address: 215 EAST 21ST STREET City: BAKERSFIELD State: CA ;Zip, .93305 ST DSL TL 4 r t/ 80 p ENTRANCE VENT C LI 0 Bravo Lu L2 Float V` 80 p ENTRANCE 1 t• 1 N. Lu V` 1 t• 1 W.O.# SCI- 3402244 i SHIFT TIME 1 6:00 AM SHIFT TIME 2 DISABLED SHIFT TIME 3 DISABLED SHIFT TIME 4 DISABLED . SHIFT BIR PRINTOUTS DISABLED 108689 PEPSI SITE 9 DAILY BIR PRINTOUTS j 215 EAST STREET DISABLED21ST BAKERSFIELD.CA 93305 TICKETED DELIVERY AUTO DIAL TIME SETUP 81152324905001 DISABLED TANK PER TST NEEDED WRN NONE I, MAY 31, 2012 7:27 AM DISABLED TANK ANN TST NEEDED WRN jDISABLED SYSTEM STATUS REPORT LINE RE- ENABLE METHOD PASS LINE TEST ALL FUNCTIONS NORMAL 1 LINE PER TST NEEDED WRN INVENTORY REPORT DISABLED LINE ANN TST NEEDED WRN y DISABLED i T 1:DIESEL FUEL RS -232 SECURITY i VOLUME - 5888 GALS PRINT TC VOLUMES CODE 000000 ULLAGE - 9214 GALS ENABLED 1k% ULLAGE- 7703 GALS TC VOLUME a 5844 GALS TEMP COMPENSATION HEIGHT - 49.64 INCHES VALUE (DEG F ): 60.0 WATER VOL - 0 GALS STICK HEIGHT OFFSET j WATER - 0.00 INCHES DISABLED RS -232 END OF MESSAGE..] TEMP - 76.8 DEG F DISABLEDH- PROTOCOL DATA FORMAT 5 HEIGHT AUTO DIAL ALARM SETUP,,:,! x x * * END x x x * x DAYLIGHT SAVING TIME ENABLED START DATE MAR WEEK 3 SUN START TIME 2:05 AM END DATE NOV WEEK 1 SUN END TIME 2:00 AM REDIRECT LOCAL PRINTOUT, SOFTWARE REVISION LEVEL DISABLED 1N -TANK SETUP I' VERSION 119.05. SOFTWARE# 346119 -100 -F EURO PROTOCOL PREFIX T,. CREATED - 00.02.25.12..15 S T 1:DIESEL FUEL j PRODUCT CODES- MODULE# 330160 -105-A THERMAL COEFF :.000450. SYSTEM FEATURES: TANK DIAMETER'' : 119 '.50PERIODICIN -TANK TESTS SYSTEM SECURITY TANK PROFILE 4 PT$. ANNUAL IN -TANK TESTS CODE 000000 FULL VOL 151'02' CSLD 89.6 INCH VOL, 12290, BIR 59.8 INCH VOL 7580 FUEL MANAGER 29.9 INCH VOL 2836,.. METER DATA YES END FACTOR: HEM ISPHER: CAL UPDATE: IMMEDIATE) FLOAT SIZE: 4.0 IN 8496!,. WATER WARNING 1,. 5 ; COMMUNICATIONS SETUP HIGH WATER LIMIT: 20(.; SYSTEM SETUP MAX OR LABEL VOL: 15102! OVERFILL LIMIT aMAY31, 2012 7:27 AM PORT SETTINGS: 2H13289] HIGH PRODUCT COMM BOARD 2 (FXMOD) 138931BAUDRATE2400DELIVERYLIMIT` SYSTEM UNITS PARITY ODD 3020 "' U.S. STOP BIT I STOP SYSTEM LANGUAGE DATA LENGTH: 7 DATA LOW PRODUCT 1000 ENGLISH DIAL TYPE TONE LEAK ALARM LIMIT: 241 SYSTEM DATE /TIME FORMAT ANSWER ON 1 RING SUDDEN LOSS LIMIT: 501 MON DD YYYY HH:MM:SS_xM TANK TILT 1'.511: Y i 4 W.O. #,SCI - 3402244 LEAK MIN PERIODIC: 0% 0 LIQUID SENSOR SETUP LEAK MIN ANNUAL 0% RECONCILIATION SETUP 0 L 1:ANNULAR SPACE DUAL FLOAT HYDROSTATIC CATEGORY ANNULAR SPACE MDIM 1: TTGG PERIODIC TEST TYPE STANDARD AUTOMATIC DAILY CLOSING, 'yTIME: 2:00 AM ANNUAL TEST FAIL L 2:TURBINE SUMP ALARM DISABLED DUAL FLT. HIGH VAPOR AUTO SHIFT 01 CLOSING ' tCATEGORYSTPSUMPTIME: DISABLED PERIODIC TEST FAIL ALARM DISABLED AUTO SHIFT 02 CLOSING TIME: DISABLED• GROSS TEST FAIL ALARM DISABLED AUTO SHIFT 03 CLOSING TIME: DISABLED ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF AUTO SHIFT 04 CLOSING,.,.; TIME: 6:00 AM i TANK TEST NOTIFY: OFF TNK TST SIPHON BREAK:OFF PERIODIC RECONCILIATION, ! OUTPUT RELAY SETUP MODE: MONTHLY DELIVERY DELAY 5 MIN ALARM: DISABLED 4 R 2:POSITIVE SHUTDOWN TEMP COMPENSATION TYPE: STANDARD STANDARD NORMALLY CLOSED BUS SLOT FUEL METER TANK;:j 2 10 0 0 1` l" IN -TANK ALARMS 2 10 1 0 ALL:LEAK ALARM ALL:SUDDEN LOSS ALARM LIQUID SENSOR ALMS I LEAK TEST METHOD L 1:FUEL ALARM L 2:FUEL ALARM TEST CSLD ALL..TANK L I :SENSOR OUT ALARM i Pd a 99%c L 2 :SENSOR OUT ALARM CLIMATE FACTOR :MODERATE L 1 :SHORT ALARM L 2:SHORT ALARM L 1:HIGH LIQUID ALARM i. LEAK TEST REPORT FORMAT L 1:LOW LIQUID ALARM NORMAL i 108889 PEPSI SITE 9 215 EAST 21ST STREET BAKER$FIELD.CA 93305 81152324905001 MAY 31. 2012, . 728,AM i k' FUEL MANAGEMENT SETUP t,t DELIVERY WARN DAYS; 0.4 F AUTO PRINT: DISABLED T 1:DIESEL FUEL AVG SALES -SUN: 0 GAL l AVG SALES -MON: 218 GAL AVG SALES -TUE: 365 GAL AVG SALES -WED: 372 GAL nun onrco_•ruoo A150 /`_Ar 4 W.O.# SC1- 3402244 108889 PEPSI SITE 9 215 EAST 21ST STREET AKERSFIELD.CA 93305 81152324905001 MAY 31. 2012 . 9:33 AM SYSTEM- STATUS_REPORT - D 8:ALARM CLEAR WARNING ALARM HISTORY REPORT IN -TANK ALARM - - - -- T I:DIESEL FUEL HIGH WATER ALARM MAY 31, 2012 8:37 AM JUN 14. 2011 9:34 AM JUN 30, 2010 8:36 AM OVERFILL ALARM MAY 31, 2012 8:26 AM. JUN 14. 2011 9:44 AM JUN 30, 2010 9:21 AM LOW PRODUCT ALARM MAY 31, 2012 8:25 AM JUN 14, 2011 9:30 AM JUN 30, 2010 8:31 AM HIGH PRODUCT ALARM MAY 31. 2012 8 :26 AM JUN 14. 2011 9:46 AM JUN 30, 2010 9:22 AM INVALID FUEL LEVEL MAY 31. 2012 8:26 AM JUN 14, 2011 9:,30 AM.''; JUN 30, 2010 8:32 AM PROBE OUT MAY 31, 2012 8:43 AM MAY 31, 2012 8:32 AM MAY 31, 2012 8:19 AM HIGH WATER WARNING MAY 31, 2012 8:36 AM JUN 14, 2011 9:34 AM JUN 30, 2010 8:36 AM DELIVERY NEEDED. MAY 31, 2012 8:31 AM MAY 31. 2012 8:25 AM MAY 11, 2012 5:32 PM MAX PRODUCT ALARM MAY 31, 2012 8:27 AM JUN 14. 2011 9:46 AM., JUN 30, 2010 9:22 AM ACCU -CHART CAL WARN JUL 30, 2001 11:30 AM RECON WARNING JAN 27, 2003 9:30 AM JAN 20, 2003 2:30 PM JAN 13. 2003 2:30 PM RECON ALARM JAN 27, 2003 1:30 PM JAN 20, 2003 3 :30 PM JAN 13, 2003 2:30 PM LOW TEMP WARNING JUL 17, 2009 9:38 AM AUG 4. 2008 11:47 AM MAY 19, 2005 1:33 PM xxxxx END xxxx ALARM HISTORY REPORT SENSOR ALARM - -- L 1:ANNULAR SPACE ANNULAR SPACE LOW LIQUID ALARM MAY 31. 2012 8:50 AM HIGH LIQUID ALARM MAY 31, 2012 8:50 AM LOW LIQUID ALARM MAY 31, 2012 8:50 AM xxxxxENDxxxx ALARM HISTORY REPORT SENSOR ALARM - -- L 2 :TURBINE SUMP STP SUMP FUEL ALARM MAY 31, 2012 8:51 AM SENSOR OUT ALARM MAY 31, 2012 8:47 AM SENSOR OUT ALARM MIN 1d. 9nii 4:1a AM 108889 PEPSI SITE 9 215 EAST 21ST STREET BAKERSFIELD.CA 93305 81152324905001 MAY 31. 2012 8:47 AM SYSTEM STATUS REPORT D 8:ALARM CLEAR WARNING SENSOR ALARM - - - -= L 2:TURBINE SUMP STP SUMP SENSOR OUT ALARM MAY 31, 2012 8:47 AM SENSOR ALARM ------ L 1:ANNULAR SPACE ANNULAR SPACE SENSOR OUT ALARM MAY 31. 2012 8:47 AM x x x x x END x x x x x 108889 PEPSI SITE 9 215 EAST 21ST STREET BAKERSFIELD.CA 93305 81152324905001 MAY 31, 2012 9:33 AM SYSTEM- STATUS REPORT - D B:ALARM CLEAR WARNING i. i i I I i i I i i, i