HomeMy WebLinkAbout3500 GILMORE AVENUECONFIDENCE UST SERVICES, INC. 417 Montofalr Street, Bakersfield, CA 93309 800.388 -9880 or881.891.3870 I WATER IN BACKFILL:n /a DATE & TIME OF LAST FUEL DELIVERY:n /a TANK INFORMATION: WETTED) PRODUCT TYPE: TOTAL GALLONS: PRODUCT LEVEL: PERCENT FULL: TEST METHOD: WATER IN TANK: TANK MATERIAL• P.S.I.@ BOTTOM: TEST DURATION: FINAL LEAK RATE: TEST RESULT: TANK INFORMATION: ULLAGE)U /F ONLY ULLAGE GALLONS: START PRESSURE: END PRESSURE: TEST RESULT: PRODUCT LINES: LINE TYPE: START TIME: END TIME. TEST PRESSURE: FINAL LEAK RATE: TEST RESULT: MECHANICAL LEAK DETECTORS: MODEL: SERIAL NUMBER: CHECK VALVE PSI: BLEED OFF ml: LEAK RATE TESTED: TEST RESULT: TANK 1 TANK 2 TANK 3 TANK 4 Regular FINAL TEST RESULTS: ALERT 1000 / ALERT 1050 / TEI LT -3 CUSTOMER ADDRESS: WORK ORDER:29381A SITE ADDRESS: Cal- Valley Equipment Kern Countv Sup. of Schl j 3500 Gilmore Avenue TEST DATE: 6/22/2012 705 South Union Ave. Bakersfield, CA 93308. Bakersfield, CA 93307 SITE CONTACT:Jerry Rangel PHONE NUMBER:661 -979 -0953 TECHNICIAN: Doug Young PHONE NUMEER:661- 631 -3670 LICENSE: 901076 I WATER IN BACKFILL:n /a DATE & TIME OF LAST FUEL DELIVERY:n /a TANK INFORMATION: WETTED) PRODUCT TYPE: TOTAL GALLONS: PRODUCT LEVEL: PERCENT FULL: TEST METHOD: WATER IN TANK: TANK MATERIAL• P.S.I.@ BOTTOM: TEST DURATION: FINAL LEAK RATE: TEST RESULT: TANK INFORMATION: ULLAGE)U /F ONLY ULLAGE GALLONS: START PRESSURE: END PRESSURE: TEST RESULT: PRODUCT LINES: LINE TYPE: START TIME: END TIME. TEST PRESSURE: FINAL LEAK RATE: TEST RESULT: MECHANICAL LEAK DETECTORS: MODEL: SERIAL NUMBER: CHECK VALVE PSI: BLEED OFF ml: LEAK RATE TESTED: TEST RESULT: TANK 1 TANK 2 TANK 3 TANK 4 Regular Diesel ALERT 1050X ALERT 1050X ALERT 1050X ALERT 1050X TEI LT -3 TEI LT -3 TEI LT -3 TEI LT -3 Pressure Pressure 8:40am 8.57am 8:55am 9:12am 50 psi 50 psi 0.002 gph 0.001 gph PASS PASS Red Jacket FXT Red Jacket FXT Red Jacket FXT Red Jacket FXT A) These systems and methods meet or exceed the criteria in USEPA 40CrR parts 280, NFPA 329 -87 and all applicable state codes. Bj Any luWe .listed above may require further action, check with all regulatory agencies. Techn c a gnature: Date: Manufacturer car ior cation Ho: Q as- Young zzz Alert: 2009040 // TEI: LT-3,089 CONFIDENCE UST SERVICES, INC. 417 Montclair Street, Bakorsflold, CA 93309 800-339 -9930 or 881. 831 -3870 FINAL TEST RESULTS: ALERT 1000 / ALERT 1050 / TEI LT -3 CUSTOMER ADDRESS: WORK ORDER:29381A SITE ADDRESS: Cal- Valley Equipment Kern Countv Sup. of Schl 3500 Gilmore Avenue TEST DATE: 6/22/2012 705 South Union Ave. Bakersfield, CA 93308 Bakersfield, CA 93307 SITE CONTACT:Jerry Rangel PHONE NUMBER: 661-979-0953 TECHNICIAN: Doug Young PHONE NUMBER:661 -631 -3870 LICENSE: 901076 WATER IN BACKFILL:n /a DATE & TIME OF LAST FUEL DELIVERY:n /a TANK INFORMATION: WETTED) TANK 1 TANK 2 TANK 3 TANK 4 PRODUCT TYPE: TOTAL GALLONS: PRODUCT LEVEL: PERCENT FULL: TEST METHOD: WATER IN TANK: TANK MATERIAL: P.S.I.@ BOTTOM: TEST DURATION: FINAL LEAK RATE: TEST RESULT: TANK INFORMATION: ULLAGE)U /F ONLY ULLAGE GALLONS: START PRESSURE: END PRESSURE: TEST RESULT: PRODUCT LINES: LINE TYPE: START TIME: END TIME: TEST PRESSURE: FINAL LEAK RATE: TEST RESULT: MECHANICAL LEAK DETECTORS: MODEL: SERIAL NUMBER: CHECK VALVE PSI: BLEED OFF ml: LEAK RATE TESTED: TEST RESULT: Regular Diesel ALERT 1050X ALERT 1050X ALERT 1050X ALERT 1050X TEI LT -3 TEI LT -3 TEI LT -3 TEI LT -3 Pressure Pressure 8:40am 8:57am 8:55am 9:12am 50 psi 50 psi 0.002 gph 0.001 gph PASS PASS Red Jacket FXT Red Jacket FXT Red Jacket FXT Red Jacket FXT A) These systems and methods meet or exceed the criteria in USEPA 40CFR parts 280, NFPA 329 -87 and all applicable state codes. B) Any lu a listed above may require further action, check with all regulatory agencies. Techn'c'a gnature: Date: Manufacturer Cer jfication No: an or D Young III Alert: 2004040 TEI: LT-3,089