Loading...
HomeMy WebLinkAboutCUPA 6-26-19BAKERSFIELD FIRE DEPARTMENT Prevention Services Division Underground Storage Tank Program 2101 H Street DW Inspection Rep rt l � Bakersfield, CA 93301 Permission to Insp eco / _ Phone: 661-326-3979 `�— Fax: 661-852-2171 N/S f lY �Hin 4 � . L Business Name: White Lane Ceveron Express Car Wash Date:6/26/2019 Address Name: 2525 White Ln. Bakersfield Ca CAL000427260 Inspector Name: Peter Armagost #8856813 Inspection Type: Routine Report : Final [NVO= No Violation Observed OUT = Out of Compliance NA = Not Applicable UD = Undetermined COS = Corrected On Site RPT = Repeat Violation Violation Program Requirement o CD ._ SOC_ Comments No o F- 0 a.o z0. =o >z ❑ File Review Facility Tank Information 2030021 Facility has a valid Permit Tank 1 -10000 -DSL -DW to Operate from theTank ® ❑ ❑ ❑ ❑ ❑ None 2 -10000 -PRM -DW -REG CUPA - 23 CCR 16 2712(1); Tank 3 -10000 -DW HSC 6.7 25284 UST Operating Permit 2010010 Application for Facility information and Tank ® ❑ ❑ ❑ ❑ ❑ None information submitted/maintained - 23 CCR 16 2711; HSC 6.7 25286(a 2010001 Current BOE number submitted to the CUPA ® ❑ ❑ None and/or CERS - HSC 6.7 25286(c) 2030011 UST compliance statement and/or Designated Operator ® ❑ ❑ ❑ El ❑ None current certification submitted - 23 CCR 16 2715(a), 2715(b A complete and accurate 2030046 response plan has been submitted, approved and ® ❑ ❑ ❑ ❑ ❑ None maintained - 23 CCR 16 2632, 2634(e), 2641(h), 2712(i) A complete and accurate 2030041 plot plan has been submitted, approved and ® El El El❑ ❑ Minor maintained - 23 CCR 16 2632(d)(1 C , 2711 a 8) 2010006 Owner/Operator has not made false statements or ® El El El El rNo representation on any required document - HSC 6.7 25299 2010003 Owner/Operator has a DO and/or informed the CUPA of any change (s) ® ❑ ❑ ❑ ❑ ❑ None within 30 days - 23 CCR 16 2715(a) Violation Program Requirement ° SOC Comments No O _ ¢ o a 2.o CD z 0 Z _ U �> Testing 2030002 Owner/Operator has tested and certified leak ® ❑ ❑ ❑ ❑ ❑ None detection equipment annual) - 23 CCR 16 2638 2030048 Secondary containment testing conducted every 36 months in accordance 0 ❑ ❑ ❑ ❑ ❑ None with requirements - 23 CCR 16 2637 2030055 Spill buckets have been tested annually as ® ❑ ❑ ❑ ❑ ❑ None required - HSC 6.7 25284.2 2010009 Secondary containment test results submitted to the COPA within 30 days ® ❑ ❑ ❑ ❑ ❑ None after the test - 23 CCR 16 2637(e) 2030064 CUPA was poperly notified within the prescribed number of ® El❑ ❑ ❑ ❑ None hours prior to testing - 23 CCR 16 26370, 2638(e), 2643(8), 2644.1(a)(4) Install/Repair 2060009 Permits obtained to install, replace, repair, or ® ❑ ❑ ❑ ❑ [] None modify part of the UST s stem - 23 CCR 16 2712 UST System Observation General Monitoring 2030003 Leak detection system maintains continuous RD monitoring that activates ® ❑ ❑ ❑ ❑ ❑ None ❑ an audible and visual Yes alarm - 23 CCR 16 2632, 2634, 2636, 2666 91 Annular sensor failed 2030016 The annular space of the tank, piping and sumps RD are continuously monitored and activates ❑ ® ❑ E] ❑ ❑ None ❑ the alarm - 23 CCR 16 Yes 2631(8), 2632(c)(2)(A)&(8), 2633(c), 2636 2030017 Product piping outside the UDC is fail-safe and shuts down the pump or ® ❑ ❑ ❑ ❑ ❑ None restricts flow - 23 CCR 16 2636(0 (5 2030018 Turbine sump monitor RD activates an audible and visual alarm or stops the ® ❑ EJ❑ ❑ ❑ None F-1 flow of at the dispenser - Yes 23 CCR 16 2636 (0(1) Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement ° .o SOC Comments No > _ Cl) .o z o z _ o> 2030019 Monitoring system in the Dispenser 5&6 UDC floats did not UDCs activates an function due to unsecured float audible and visual alarmchain El® El El None or stops the flow at the UDC -23 CCR 16 2636 (0(1) 2030043 Leak detection equipment RD properly programmed or ® El❑ ❑ ❑ ❑ None ❑ properly operated - 23 CCR 16 2.632, 2634, 2636, Yes 2666 2060005 System constructed with a monitoring system capable of detecting entry ® None into secondary containment - HSC 6.7 25291 b 2060014 Correct leak detection equipment installed for RD the type of system ® ❑ ❑ ❑ ❑ ❑ None ❑ present - 23 CCR 16 2638; Yes HSC 6.7 25290.1, 25290.2, 2060015 25291 Sensor located in the RD Reular & Diesel sensors in turbin sump were not located at the proper position/location - ❑ ® El El E] None ❑ lowest point of the sump 23 CCR 16 2630(d), 2641(a) Yes 2030062 Facility is in compliance RD with not tampering with or ® ❑ ❑ ❑ ❑ ❑ None El disabling leak detection devices or alarms - HSC Yes 6.7 25299 a 9 2060022 System constructed with a monitoring system capable of detecting entry ® ❑ ❑ ❑ ❑ ❑ None into secondary containment - HSC 6.7 25290.2(d) 2030034 Tag/sticker on affixed monitoring equipment being certified, repaired, ® ❑ E]❑ ❑ ❑ None or replaced - 23 CCR 16 2638 VPH Monitoring VPH 2030065 Interstitial monitoring of RD the annular spaces of the ❑ ❑ ® ❑ ❑ ❑ None El UST is properly Yes maintained - HSC 6.7 25290.1 e 2060023 System constructed with a monitoring system capable of detecting entry ❑ ❑ ® ❑ ❑ ❑ None into secondary containment - HSC 6.7 25290.1(d) Underground Storage Tank Program - DW Inspection Report v 2.0 Underground Storage Tank Program - DW Inspection Report v 2.0 Program Requirement ° o SOC Comments Violation No o _ Q 0 o CL (1) Z o z D 0 Wo> Line Leak Detector 2060012 Line leak detector installed on pressurized RD piping system - HSC 6.7 ❑ ❑ ® ❑ ❑ ❑ None ❑ 25290.1(h), 25290.2(8), Yes 252910, 25292(e), 26360 (2) 2030026 Line leak detectors detect a 3 gph leak and/or RD audible and visual alarm ❑ ❑ ® ❑ ❑ ❑ None ❑ function properly - 23 Yes CCR -16 26360(6), 2666(c) Turbine shuts down when 2030027 RD a leak is detected or when line leak detector is ❑ El® El ❑ ❑ None ❑ disconnected - 23 CCR 16 Yes 2666 c 2030025 Pressurized piping able to detect a 3.0 gph leak RD within an hour, and ❑ ❑ ® ❑ ❑ ❑ None ❑ restricts the flow or Yes alarms - 23 CCR 16 2636(0 (2) Secondary Containment RD 2060010 UST storing a hazardous substance has secondary ® ❑ ❑ ❑ ❑ ❑ None ❑ containment - HSC 6.7 Yes 25292 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement ° .o SOC Comments No O U) F- ? Q o 0 a �o z 0. z D o> 2030008 UDC, sumps, and/or ❑ other secondary ❑ ❑ ❑ None RP ❑ Yes containment in good ® ❑ ❑ ❑ ❑ ❑ ❑ condition and/or are free of debris/liquid - HSC 6.7 25290.1, 25290.2, 25291 2030040 Secondarily contained piping maintained to allow ® ❑ ❑ ❑ ❑ ❑ liquid to drain into sump - 23 CCR 16 2630(d), 2641 a) 2060006 Secondary containment piping slopes back to the ® ❑ ❑ ❑ ❑ ❑ collection sump - 23 CCR 16 263(c) 2030047 Secondary containment maintained tight and has been confirmed by testing ® ❑ ❑ ❑ ❑ ❑ - 23 CCR 16 2662; HSC 6.7 25290.1(c)(2), 25290.2(c)(2), 25291 (a), 25292(e) 2030060 Entry fittings in secondary containment for UST system maintained ® ❑ ❑ ❑ ❑ ❑ tight/sealed - 23 CCR 16 2630, 2635(d), 2636(c), 2666 2060020 Spill bucket is installed and has a functional drain ® ❑ ❑ ❑ ❑ ❑ valve or other means to remove liquid - 23 CCR 16 2635 )),2665 2030054 Spill bucket maintained in good condition and free of ® ❑ ❑ ❑ ❑ ❑ debris and/or liquid - 23 CCR 16 2635(b), 2715(c)(2) 2060019 Spill bucket to has a minimum capacity of five ❑ ® ❑ ❑ ❑ ❑ gallons - 23 CCR 16 2635(b), 2665 Overfill 2030035 UST system is operated to prevent unauthorized release, including spills and overfills - HSC 6.7 25292.1 a 2030036 Overfill prevention system has not been overridden and meets overfill requirements - 23 CCR 16 2635(b)(2), 2665 None RD None ❑ Yes None None None RP None ❑ Yes RP None ❑ Yes Diesel Spill Bucket unable to maintain liquid for annual test None Underground Storage Tank Program - DW Inspection Report v 2.0 ❑ ❑ ❑ ❑ ❑ None RP ❑ Yes ❑❑ ❑ ❑ None RP ❑ Yes ❑ Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement a o SOC Comments No o _ z _ _ o a� �.o z O o> On Site Records Certifications 2030023 Required designated operators or contractors maintain a proper and ® ❑ ❑ ❑ ❑ ❑ None current ICC certification - 23 CCR 16 2715 2030024 Service technician, installer, and/ or employee maintain a ® ❑ ❑ ❑ ❑ ❑ None proper license - 23 CCR 162715 2030031 Employee or contractor obtained and maintained proper manufacturer ® ❑ ❑ ❑ ❑ ❑ None certification - 23 CCR 16 2715 2010007 Submit/maintain current Certificate of Financial Responsibility/mechanism of financial assurance - ® ❑ ❑ ❑ �] ❑ None 23 CCR 16 2711; 23 CCR 18 2808.1, 2809-2809.2; HSC 6.7 25292.2; HSC 6.75 25299.30-25299.34 Designated Operator 2010004 Copies of DO inspections for last 12 months and list of trained employees ® El El❑ ❑ ❑ None maintained - 23 CCR 16 2715 2030013 Designated operator properly conducted the monthly inspection and ® ❑ ❑ ❑ ❑ ❑ None the reports are complete - 23 CCR 16 2715 2030010 DO notified operator of any condition observed during the monthly ® ❑ ❑ ❑ ❑ ❑ None inspection that may require action - 23 CCR 16 2715(d) 2030012 DO employee training performed, current for at ® ❑ ❑ ❑ ❑ ❑ None least one employee on site, and a log kept - 23 CCR 16 2715(c)(6), 2715(fi) Underground Storage Tank Program - DW Inspection Report v 2.0 Program Requirement ,o SOC Comments Violation No z D cn O t- a. o Z _ v,> Logs 2030001 Leak detection alarm logs, maintenance and RD records of appropriate ® ❑ ❑ ❑ ❑ ❑ None ❑ follow-up actions Yes maintained - 23 CCR 16 2632, 2634, 2712(b) Maintenance/Tests 2010008 Monitoring, maintenance, repairs, linings, and RD upgrade records ® ❑ ❑ ❑ ❑ ❑ None ❑ maintained for the proper Yes time period - 23 CCR 16 2712(p) Documentation 2030033 Failure to maintain on site an approved monitoring ® ❑ ❑ ❑ ❑ ❑ None plan - 23 CCR 16 2632, 2634, 2711, 2712(1) 2030037 Written agreement between the tank owner and tank operator to monitor the tank system ® ❑ ❑ ❑ ❑ ❑ None is maintained - 23 CCR 16 2620(b); HSC 6.7 25284(a 3 2030061 Suspected or actual RD unauthorized release reported in appropriate ❑ ❑ ® ❑ ❑ ❑ None ❑ time frame - HSC 6.7 Yes 29294, 29295 General Operating Requirements Permit Condition/Approval 2030039 Compliance with all operating permit ® ❑ ❑ ❑ ❑ ❑ None conditions - 23 CCR 16 2712; HSC 6.7 25299 2030059 UST system maintained in accordance with exclusion/exemption ® ❑ ❑ ❑ ❑ ❑ None status - HSC 6.7 25281.6, 25283.5 2030014 Owner/Operator received approval and has implemented a training ❑ ❑ ® ❑ ❑ ❑ None program at an unstaffed facility - 23 CCR 16 2715 (0(2) 2030015 Facility exhibited that the method used to monitor the tank meets the monitoring methods in ® ❑ ❑ ❑ ❑ ❑ None 2643(f) - 23 CCR 16 2643 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement 0 .o SOC Comments No o _ Q = o � (3) o z o z o> Red Tag 2030045 Red Tag information is legible and has not been ❑ ❑ ® ❑ ❑ ❑ None tampered with - 23 CCR 16 2717.1 2030044 Facility did not allow for deposit of petroleum into a UST that has a red tag ❑ ❑ ® ❑ ❑ ❑ None affixed to the fill - 23 CCR 16 2717.1 Install/Repair 2060024 UST system is made of or lined with materials that are compatible with the ® ❑ ❑ El❑ ❑ None substance stored - 23 CCR 16 2631.1 2060021 Striker plate installed and positioned correctly - 23 ® ❑ ❑ ❑ ❑ ❑ None CCR 16 2631(c), 2662(d ® There were no violations noted for this inspection. ®This report shall serve as a "NOTICE TO COMPLY" for Minor Violations, and a "NOTICE OF VIOLATION" for Major violations. You are, hereby, ordered to correct the above noted violations within 30 days, or according to correction summaries provided. Formal enforcement and/or penalty assessment may be initiated for any violations noted, and for those not corrected in a timely manner. (NOTE: If this is a preliminary report, a final report will follow.) �® Inspectors Signature: Date:' p g Inspector: Enter # of Violations: RD: RP: Check one box for facility Significant Operational Status (SOC) to be reported to SWRCB and US EPA: ❑ SOC with both Release Detection and Release Detection (Facility has no Release Prevention and no Release Prevention Violations) ❑ Not in SOC (Facility has both Release Prevention and Release Detection Violations) ❑SOC with Release Detection only (Facility has no Release Detection violations but one or more Release Prevention violations) ❑ SOC with Release Prevention only (Facility has no Release Prevention violations but one or more Release Detection violations) Underground Storage Tank Program - DW Inspection Report v 2.0