Loading...
HomeMy WebLinkAboutFire Safety 6-27-19 FMC_7-9BAKERSFIELD FIRE DEPARTMENT FIRE PREVENTION INSPECTION ' f Prevention Services 2101 H Street Bakersfield, CA 93301 Phone: 661-326-3979 9 Fax: 661-852-2171 FACILITY ADDRESS a DATE FEE FACILITY NAME P CITY, STATE, ZIPdk4_1 D e BUSINESS OWNER'S NAME AND ADDRESS MANAGER'S NAME PH NO. BILL TO: (IF DIFFERENT FROM ABOVE) NAME, ADDRESS CITY, STATE, ZIP PH NO. nr TypE OCC LOAD NO.�OF FLOORSF - OCC USE 11 RISER DATE 1 1 1A Wet/Dry Sprinkler System Type of Alarm System CONSTRUCTION TYPE HIGH RISE BLDG ❑YES NO SQ/FT.OF BLD CALIFORNIA BUILDING CODE B.M.C. BAKERSFIELD MUNICIPAL CODE N.F.P.A. NATIONAL FIRE PROTECTION ASSOCIATION REQUIREMENTS CORRECT ALL VIOLATIONS VIOLATION CHECKED BELOW NO. Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises (CFC COMBUSTIBLE WASTE / DRY 1 304.1.1) VEGETATION Provide non-combustible containers with tight fitting lids for the storage of combustible waste and 2 rubbish pending its safe disposal. (CFC 304.3.2) Note: applies to containers over 40 gallons. Relocate combustible storage to provide at least 3 feet clearance around motor fuse box/fire door (CFC COMBUSTIBLE STORAGE 3 605.3) Relocate fire extinguisher(s) so that they will be in a conspicuous location, hanging on brackets with the 4 top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9) EXTINGUISHERS 5 Provide and install (amount) _____ approved (type & size) .................. portable fire (CFC extinguisher to be immediately accessible for use in (area) _____________________________ TABLE 906.3) Re -charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and/or 6 after each use, by a person having a valid license or certificate. (CFC 906.2) Provide and maintain "EXIT" sign(s) with letters 6 or more inches in height over each required exit SIGNS 7 (door/window) to fire escape. (CFC 1011) Provide and maintain appropriate numbers on a contrasting background and visible from the street to 8 indicate the correct address of the building. (CFC 505.1) Repair all (cracks/holes/openings) in plaster in (location) --------------------------------------- _---------------------'FIRE the to its original fire resistive condition (CFC 703.1) 9 FIREDOORS/ Plastering shall return surface FIRE SEPARATIONS Remove /repair (item & location) --------------------------------------------------------- doors shall be designed to close by gravity, or by the action of a mechanical device, or by an 10 Self-closing smoke and heat sensitive device. Self-closing doors shall have no attachments capable of approved preventing the operation of the closing device. (CFC 703.2) Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1031.1) 11 EXITS Provide a contrasting colored and permanently installed electric light over or near required exit (CFC 1008) 12 (location) ____________________________ to clearly indicate it as an exit. Remove all storage and/or other obstructions from fire escape landings and stairways stair shafts. (Fire (CFC 1003.6) 13 STORAGE escapes/stair shafts are to be maintained free from obstructions at all times.) Extension cords shall not be used inlieu of permanent approved wiring. Install additional approved ELECTRICAL APPLIANCES 14 electrical outlets where needed. ( ) Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (CFC 15 605.4) OUTDOOR BURNING 16 Recreational fires oro en burnin . CFC 307.1 Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.). A©�'•-� FIREWORKS 17 OTHER 18 CUSTOMER: INSPECTOR: Correct the violations noted above by: (Signature) (Please Print Name Legibly, Title) (j NO.. White — Prevention Services Yellow — Station Copy Pink — Business Copy LEGEND: C.F.C. CALIFORNIA FIRE CODE C.B.C. CALIFORNIA BUILDING CODE B.M.C. BAKERSFIELD MUNICIPAL CODE N.F.P.A. NATIONAL FIRE PROTECTION ASSOCIATION N.E.C. NATIONAL ELECTRIC CODE FD 2022 (Rev. 03/2019)