Facility Name: (7 V\-<_* k ' 11N I kil <1 Date: /"yam / 17
Site Address: . CuL " Time In: t0ac> Time Out: # '
Owner /Operator: Phone: d - " ;. '"� EPA ID # t— ` 9 S.� �.
Type of Inspection
" Routine 0 Re- inspection/Follow -up 0 Combined Routine Inspection d Joint Inspection 0 Complaint 0 Focused 0 Other
0 CONSENT TO INSPECT GRANTED BY (Name / Title):
Inspection may involve obtaining: photographs, review and copying of records, and determination of compliance with hazardous waste handling requirements.
C=C Taint: V = Class I, II or Minor Violation
C
V
HAZARDOUS WASTE REQUIREMENT
N/A
CEitS
Violation #
COMMENTS
s
Recordkee in documentation
Generator has an EPA ID number [HSC25143.131
3010002
Hazardous waste determination' made for all wastes
0 Analysis 0 Generator Knowledge [CCR 66262.401
3030005
Conlin ency plan information " posted near phone [CCR 66262.34(d)(2)]
3010022
'
'Facility ' ersonnel'demonstrate training/awareness [CCR 66262.34(d)(2)]
3020001
Manifests/Consolidated Manifest receipts complete . [CCR 66262.23(a)]
3010008
Blue co (s) of manifest mailed to DTSC [CCR 66262.23(a)(4)]
3010011
Bills of Lading/receipts available [CCR 66262.40(a)] '
3010010
LDRs available and complete CCR 66268.7(a)]
3030006
Onsite recycling reported using UPCF [HSC 25143.10]
3030001
Container /tank management
Containers are in good condition CCR 66262.34(d)(2)]
3030013
.
Containers are closed exce twhen adding/removing [CCR66262.34(d)(2)]
3030017
Satellite containers at or near point of generation [CCR 66262.34(e) ('1)(A )]
Em t containers are empty [CCR 66262.34(D]
3030007
`Containers inspected weekly [CCR,66262.34(d)(2)]
3030019
Tanks inspected daily CCR 66262.34 d 2 , 40CFR 265.2011
3030027
]
Onecontainer per waste stream at satellite area CCR 66262.34 d 2
3030022
.:
Exclude recyclable materials stored in accordance with local
ordinancelhazardous materials codes [HSC 25143.10]
3010016
r
Accumulation Time "Limits
Waste is accumulated not.more than 90 /180/270 CCR 66262.34(d)]
3030010
j
Empty containers managed within one year CCR 66262.34(d)]
3030010
Universal, waste accumulated less than one ym [CCR 66273.15(a)]
3030011
Used oil filters offsite within 180 (1 year <1 ton)' [CCR 66266.130(c)(4)]
3030004
Pb -acid' batteries' offsite within 180 (1 yr. < 1 ton) [CCR66266.81(a)(3)]
3030002
Labeling/Marking
Containers are properly labeled [66262.34(f)]
3030007
Excluded recyclable materials marked properly [HSC 25143.9(a)]
3050005
Universal waste: container properly labeled (CCR 66273.341
3030008
Used oil filters marked "drained used oil filters" [CCR 66266.1301
3030004
Date written on spent lead- acid - batteries [CCR 66266.81(a)(6)(B)] .
3030003
"Used Oil" marked on all used oil tanks /containers CCR 66279.21
3030007
Tank marked with "hat waste" , contents, start date 66262.34 (f)]
3030007
Treatment Transport and Disposal/Other
Have permit/authorization to do treatment [HSC 25136.21
3040003
Waste sent with authorized transport (en. eligible) [CCR 66263.411
3050001
Waste dis osed of to authorized oint/ art [HSC 25.189.5(a)]
3050002
Failed to properly handle appliance wastes FHSC 25212 a
Fire Protection [66262.34(d)(2)]
3030032
Print and sign in this box for receipt of this report. Signature does not imply agreement with findings only receipt of report.
� � t z")
INSPECTOR z: - a'
..'
POST INSPECTION INSTRUCTIONS:
• Correct the violation(s) noted above by $ r A r
Signature (that all violations have been corrected as noted)
• Within 5 days, of'correcting all of the violations, sign and return a copy of this page to:!' t.r
Bakersfield Fire Dept., Prevention' Services, 2101 H St. Bakersfield, CA 93301 Date
FD2171 (Rev 9/14)