Loading...
HomeMy WebLinkAboutsouth_Fire Safety 7-23-1914 i f BAKERSFIELD FIRE.DEPARTMENT FIRE PREVENTION INSPECTION' Prevention 'Services ' 2101 H Street .;,' Bakersfield,. CA .933`01 Phone: 661-326-3979 •• Fax: 661-852-2171,.° FACILITY ADDRESS DATE. w FEE FACILITY NAME�}-7? -7 r CITY, STATE, ZIP dt G.. ✓ �i P" Li BUSINESS OWNER'S NAME AND ADDRESS MANAGER'S NAME; PH NO: BILL TO:.(IF DIFFERENT FROM ABOVE) NAME, ADDRESS CITY, STATE, ZIP' PH NO. ' CC TYPE ley OCC LOAD NO. OF FLOORS OCC USE RISER DATE I r19 ; Wet/Dry Sprinkler System Type of Alarm System j �,r� CONSTRUCTION TYPE HIGH RISE BLD ❑ YES NO SQ/FT OF BLD CORRECT.ALL VIOLATIONS VIOLATION REQUIREMENTS-, CHECKED BELOW NO, Remove and safelyof all hazardous refuse and dry vegetation ,on the above 'premises (CFC COMBUSTIBLE WASTE / DRY 1 ,dispose 304.1.1) VEGETATION Provide non..combustible containers with tight fitting,lids for the storage of•comb:.ustibl;e waste and 2 rubbish pending its safe disposal. (CFC 304.3.2), Note: applies to containers over 40' gallons. Relocate combustible storage to provide at least 3 feet clearance around motor'fuse box/fire door (CFC COMBUSTIBLE STORAGE 3 605.3) 4 Relocate fire extinguishers) so that they will be in a ,conspicuous location, hanging on by ckets with, the top to the extinguisher not more than 5 feet above the floor. (CFC 90.6.5 EXTINGUISHERS5 Provide and install (amount) _____ pproved (type & size) ___ __ _ portable fire CCFC extinguisher to be immediately accessible for use in (area): ________ ____ ----------- _ - TABLE 906.3) 6 Re -charge all,fire extinguishers. Fire extinguishers shall be' serviced ;at least once each •year, and/or .ertificate. after .each use, by a person .having a valid license or c(CFC 906.`2) Provide acid maintain"' EXIT" sign(s) ,with letters 6 or more inches in height over each requ'i,red exit SIGNS 7 (door/window) to fire escape.. '(CFC 1011)' Provide and appropriate numbers on a contrasting background .and visible from the, street to g .maintain. indicate the correct address of the building. (CFC 505.1) ;;•, r g°< Repair, all (cracks/holes/openi;ngs) in plaster in (location) -------- ----------- ------------------ °'astering the surface to itsfire ,resistive condition. (CFC 703. 1) ` FIRE DOORS �� shall return .'original FIRE SEPARATIONS . 10 Remove/repair. (item & location) ------------------------=--------=------------ Self-closing doors shall'be designed to,clos by gr..a.vity, or by�the action of a mechanical device, or by an approved smoke and heat sensitive devicertyrS'elf-qv; g doors shall have no�attachments capable of preventing the operation of the ciosing dey'irce. (CFC 703.2) 11 lways. aintai,ji-1all xaexa'ns. of egress free of any,.storage. .(CFC 1031.1) Remove all obstruction from hal,M EXITS 12 Provide a contrasting colored and per installed ,electric light over or near required exit (location) _-___----__------------------ to clearly .indicate. it;.as an exit. (CFC ,1008), Remove all storage .and/or other obstructions from fire escape 1andin"gs;and stairways stair`,shafts. (Fire sroRAoe 13 escapes/stair shafts are to berm aintained free from obstructions at all`tirnes.) (CFC '1003.6) Extension cords shall not be'used in lieu of permane`nt approved 'wiring: .Install additional approved ELECTRICAL APPLIANCES 14 Electrical outlets where needed. (CFC 60.5.5) 15 Remove mulfiple attachment cords from specific electrical convenience outlet (one plug per outlet) • 605.4), ouT�ooRBURNING 16 Recreational fires or open burnin . CFC '307.1 FIREWORKS 17 Violations of Section (CFC 5608.1) & 8.44_.040. (B.M:C.). OTHER 18}' V10 Correct tl�e violations noted above by: .. CORRECTION DATE ,� `� � ''� � t V CA v' "'"`� f i r16 LEGEND:, C.F.C. � CALIFORNIA FIRE CODE CUSTOMER: L� 1 (Please Pnnt Name Legibly' Title) (Signature) k C.B.C.-CALIFORNIA BUILDING CODE B M.C.' BAKERSFIELD MUNICIPAL CODE FIRE PROTECTION NO.. N.F.P.A. NATIONAL INSPECTOR: . ,ASSOCIATION. . N.E.C. NATIONAL ELECTRIC CODE White: - Prevention Services Yellow =Station Copy _Pink - Business Copy FD 2022 (Rev. 03/2019) "