HomeMy WebLinkAboutCUPA REPORT 5.2.19Underground Storage Tank Program
DW Inspection Report
Permission to Inspect: /
BAIKERSFIELD FIRE DEPARTMENT
Prevention Services Division
2161 H Street
Bakersfield, CA 93301
Phone: 661 -3,26 -3979
Fax: 661 -852 2171
I
Violation
Program Requirement
Business Name: Costco Wholesale #643 (15- 021 - 070133)
Dater 5/02/2019 (EP�
ID#
AR000170506)
Address Name: 4900 PANAMA LN, BAKERSFIELD, CA 9
313
Inspector Name: Kris
arns
ICC# 8292402
(661) 398 -4740
I-
Cn
'O
F-
I
Inspection Type: Routine
Report : Final
No Violation Observed OUT = Out of Compliance
NA = Not Applicable UD = Una
ter
fined
ENVO
Corrected On Site RPT = Repeat Violation
v
Violation
Program Requirement
Q0
°, o
SOC
omments
No
I-
Cn
'O
F-
z
o
z
M
v
File Review
Facility Tank Information
2030021
Facility has a valid Permit
Tan
- 30000
- Re DW
g -
to Operate from the
®
❑
❑
❑
0
❑
N n
° e
Tan
- 30
00 -Reg #2 - DW
CUPA - 23 CCR 16 2712(i);
!
Tank
- 30ob0
- Sup - DW
HSC 6.7 25284
Tank
-150
0 - Gas Additive - DW
2010010
UST Operating Permit
Application for Facility
information and Tank
information
®
❑
❑
❑
❑
❑
None
submitted /maintained - 23
CCR 16 2711; HSC 6.7
25286(a)
2010001
Current BOE number
submitted to the CUPA
®
❑
❑
0
❑
None
and /or CERS - HSC 6.7
_j
25286(c)
2030011
UST compliance
statement and /or
Designated Operator
®
❑
❑
❑
None
current certification
submitted - 23 CCR 16
2715(a), 2715(b)
2030046
A complete and accurate
j
response plan has been
submitted, approved and
®
❑
�
❑
❑
F]
None
maintained - 23 CCR 16
2632, 2634(e), 2641(h),
j
2712(j)
2030041
A complete and accurate
plot plan has been
submitted, approved and
®
❑
I❑
❑
❑
❑
Minor
maintained - 23 CCR 16
2632(d)(1)(C), 2711(a)(8)
2010006
Owner /Operator has not
made false statements or
representation on any
®
❑
❑
❑
❑
❑
None
j
required document - HSC
6.7 25299
2010003
Owner /Operator has a
DO and /or informed the
CUPA of any change 9 (s )
®
❑
FL]
❑
❑
❑
None
within 30 days - 23 CCR
16 2715(a)
j
U1
Violation
Program Requirement
a o
SOC
C
, mments
No
in
E-
L
z
O
z
ce.
�>
Testing
'I
2030002
Owner /Operator has
tested and certified leak
®
❑
0
❑
E]
❑
None
detection equipment
annual) - 23 CCR 16 2638
2030048
Secondary containment
testing conducted every
36 months in accordance
®
❑
0
❑
❑
❑
None
with requirements - 23
CCR 16 2637
2030055
Spill buckets have been
tested annually as
®
❑
❑
El
E]
F-1
None
required - HSC 6.7 25284.2
2010009
Secondary containment
test results submitted to
the CUPA within 30 days
®
❑
❑
❑
❑
❑
None
after the test - 23 CCR 16
2637(e)
2030064
CUPA was poperly
notified within the
prescribed number of
®
❑
❑
❑
[]
None
hours prior to testing - 23
CCR 16 26370, 2638(e),
2643 (9), 2644.1 a 4
Install /Repair
2060009
Permits obtained to
install, replace, repair, or
®
El
0
❑
L]
❑
None
modify part of the UST
system - 23 CCR 16 2712
UST
System Observation
General Monitoring
I
2030003
Leak detection system
maintains continuous
RD
monitoring that activates
®
❑
0
❑
0
[]
None
❑
an audible and visual
Yes
alarm - 23 CCR 16 2632,
2634, 2636, 2666
2030016
The annular space of the
j
tank, piping and sumps
RD
are continuously
monitored and activates
®
❑
❑
❑
❑
None
j ❑
the alarm - 23 CCR 16
Yes
2631(9'), 2632(c)(2)(A) &(e),
2633(c), 2636
2030017
Product piping outside the
UDC is fail -safe and shuts
down the pump or
®
❑
❑
F-1
E]
❑
None
restricts flow - 23 CCR 16
2636(0(5)_
2030018
Turbine sump monitor
RD
activates an audible and
visual alarm or stops the
❑
❑
❑
❑
❑
None
❑
flow of at the dispenser -
Yes
23 CCR 16 2636(0(1)
I
�
iderground Storage Tank Program - DW Inspection Report
i
I
i
i
v 2.0
Violation
Program Requirement
° o
SOC
C
mments
No
>
>
in
O
n-
a�
U c
z
O
z
v
o'>
2030019
Monitoring system in the
UDCs activates an
audible and visual alarm
®
❑
❑
❑
❑
❑
None
or stops the flow at the
UDC -23 CCR 16
2636( 0(1)
2030 043
Leak detection equipment
I RD
properly programmed or
properly operated - 23
®
❑
❑
❑
❑
❑
None
❑
CCR 16 2632, 2634, 2636,
Yes
2666
2060005
System constructed with
a monitoring system
capable of detecting entry
®
❑
❑
❑
El
❑
None
into secondary
containment - HSC 6.7
25291(b)
2060014
Correct leak detection
j
equipment installed for
RD
the type of system
®
❑
❑j
❑
0
❑
None
❑
present - 23 CCR 16 2638;
Yes
HSC 6.7 25290.1, 25290.2,
25291
2060015
Sensor located in the
RD
proper position /location -
®
❑
❑
❑
i
❑
None
❑
23 CCR 16 2630(d), 2641(a)
Yes
2030062
Facility is in compliance
RD
with not tampering with or
disabling leak detection
®
❑
❑
❑
❑
❑
None
' ❑
devices or alarms - HSC
Yes
6.7 25299(a)(9)
2060022
System constructed with
a monitoring system
I
capable of detecting entry
®
❑
❑
❑
❑
❑
None
into secondary
containment - HSC 6.7
25290.2(d)
2030034 Tag /sticker on affixed
monitoring equipment
being certified, repaired, ® El El
❑ ❑ ❑ None
or replaced - 23 CCR 16
i
26380
VPH Monitoring VPH
RD
2030065 Interstitial monitoring of
the annular spaces of the
UST is properly ® ❑
❑
El
❑
None
❑
maintained - HSC 6.7
! Yes
25290.1(e
2060023 System constructed with
a monitoring system
j
capable of detecting entry
into secondary ® ❑
❑
❑
❑
❑
None
containment - HSC 6.7
25290.1(d)
j
I
I
I
I
I
I
v 2.0
iderground Storage Tank Program - DW Inspection Report
b
Violation
Program Requirement
a°, .o
SOC
C
` mments
No
o
i—
0
F-
a
to
'
o
Line Leak
Detector
I
2060012
Line leak detector
installed on pressurized
RD
piping system -HSC 6.7
®
❑
❑
❑
0
❑
None
❑
25290.1(h), 25290.2(8),
Yes
25291(1), 25292(e),
26360 (2)
2030026
Line leak detectors detect
a 3 gph leak and /or
RD
audible and visual alarm
®
❑
❑
❑
0
❑
None
❑
function properly - 23
Yes
CCR 16 2636(0(6),
2666(c)
2030027
Turbine shuts down when
RD
a leak is detected or
when line leak detector is
®
❑
❑
❑
❑
❑
None
❑
disconnected - 23 CCR 16
Yes
2666(c
2030025
Pressurized piping able to
c a 3.0 h
detect 9p leak
i
RD
within an hour, and
®
❑
❑
❑
0
❑
None
❑
restricts the flow or
Yes
alarms - 23 CCR 16
26360(2)
Secondary Containment
j
2060010
UST storing a hazardous
RD
substance has secondary
®
❑
❑
❑
0
❑
None
❑
containment - HSC 6.7
Yes
25292
v 2.0
Underground Storage Tank Program - DW Inspection Report I
Violation
Program Requirement
° 0
30C
Comments
No
o
_
o
o
a
,o
Z
o
Z
M
4
o>
>
2030008
UDC, sumps, and /or
other secondary
containment in good
®
❑
❑
❑
0
❑
None
condition and /or are free
1
of debris /liquid - HSC 6.7
25290.1, 25290.2, 25291
2030040
Secondarily contained
RD
piping maintained to allow
L
❑
❑
❑
0
❑
None
❑
liquid to drain into sump -
Yes
23 CCR 16 2630(d), 2641 a
2060006
Secondary containment
piping slopes back to the
®
❑
1
❑
None
collection sump - 23 CCR
16 263(c)
2030047
Secondary containment
maintained tight and has
been confirmed by testing
®
❑
❑1
❑
El
❑
None
- 23 CCR 16 2662, HSC 6.7
25290.1(c) (2), 25290.2(c) (2),
25291 (a), 25292(e )
2030060
Entry fittings in secondary
1
containment for UST
system maintained
®
❑
❑
❑
0
❑
None
tight/sealed - 23 CCR 16
2630, 2635(d), 2636(c),
2666
2060020
Spill bucket is installed
RP
and has a functional drain
valve or other means to
®
❑
❑
❑
❑
❑
None
❑
remove liquid - 23 CCR 16
Yes
2635(b), 2665
1
2030054
Spill bucket maintained in
RP
good condition and free of
®
❑
E]
❑
0
E]
None
F-1
debris and /or liquid 23
Yes
CCR 16 2635(b), 2715(c)(2)
i
2060019
Spill bucket to has a
minimum capacity of five
®
❑
❑
❑
E
❑
None
gallons - 23 CCR 16
2635(b), 2665
Overfill
2030035
UST system is operated
RP
to prevent unauthorized
release, including spills
®
❑
❑
❑
❑
❑
None
❑
and overfills - HSC 6.7
Yes
25292.1 a
2030036
Overfill prevention system
RP
1
has not been overridden
and meets overfill
®
❑
❑
❑
❑
❑
None
❑
requirements - 23 CCR 16
Yes
2635(b)(2), 2665
Underground Storage Tank Program - DW Inspection Report I v 2.0
Violation
Program Requirement
i
°� o
SOC
Comments
No
o
O
o
a
Lim
1-6
�.o
z
0
U
21
On
Site
Records
Certifications
2030023
Required designated
operators or contractors
maintain a proper and
®
❑
Eg
❑
❑
❑
None
current ICC certification -
23 CCR 16 2715
2030024
Service technician,
installer, and/ or
employee maintain a
®
❑
❑I
❑
❑
❑
None
proper license - 23 CCR
162715
2030031
Employee or contractor
obtained and maintained
i
proper manufacturer
®
❑
El
F-1
El
E]
None
I
certification - 23 CCR 16
2715
2010007
Submit/maintain current
Certificate of Financial
Responsibility /mechanism
of financial assurance -
®
El
❑
0
❑
None
23 CCR 16 2711; 23 CCR
18 2808.1, 2809- 2809.2,
HSC 6.7 25292.2; HSC
6.75 25299.30 - 25299.34
Designated Operator
j
2010004
Copies of DO inspections
!
for last 12 months and list
of trained employees
®
❑
I❑
❑
❑
❑
No'ne
maintained - 23 CCR 16
2715
2030013
Designated operator
properly conducted the
monthly inspection and
®
❑
I❑
❑
❑
None
the reports are complete -
!
23 CCR 16 2715
2030010
DO notified operator of
any condition observed
during the monthly
®
❑
❑
E
❑
None
inspection that may
j
require action - 23 CCR 16
2715(d)
2030012
DO employee training
performed current for at
!
least one employee on
®
❑
❑
❑
E]
❑
None !
site, and a log kept - 23
CCR 16 2715(c)(6), 27150
v 2.0
Underground Storage Tank Program - DW Inspection Report
Violations
Program Requirement
° Go
SOC
C
' mments
No
o
_
o
o
a
i1
Z
O
U
pij
Logs
2030001
Leak detection alarm
logs, maintenance and
RD
records of appropriate
®
❑
❑
❑
0
❑
None
❑
follow -up actions
Yes
maintained - 23 CCR 16
2632, 2634, 2712(b)
Maintenance/Tests
2010008
Monitoring, maintenance,
repairs, linings, and
RD
upgrade records
®
El
ED
0
❑
None
El
maintained for the proper
Yes
time period - 23 CCR 16
2712(b
Documentation
2030033
Failure to maintain on site
an approved monitoring
®
❑
❑
❑
0
❑
None
plan - 23 CCR 16 2632,
2634, 2711, 2712(i)
2030037
Written agreement
between the tank owner
and tank operator to
monitor the tank system
®
❑
❑
❑
❑
❑
None
is maintained - 23 CCR 16
2620(b); HSC 6.7
25284(a)(3)
2030061
Suspected or actual
RD
unauthorized release
reported in appropriate
❑
❑
❑
❑
❑
None
❑
time frame - HSC 6.7
Yes
29294, 29295
General
Operating Requirements
Permit Condition /Approval
I
2030039
Compliance with all
operating permit
®
❑
❑
F-1
None
conditions - 23 CCR 16
j
2712, HSC 6.7 25299
2030059
UST system maintained
in accordance with
exclusion /exemption
®
❑
❑
❑
❑
❑
None
status - HSC 6.7 25281.6,
25283.5
2030014
Owner /Operator received
j
approval and has
implemented a training
El
El
❑
❑
None
program at an unstaffed
facility - 23 CCR 16
2715( (2
2030015
Facility exhibited that the
method used to monitor
the tank meets the
monitoring methods in
®
❑
❑
❑
❑
❑
None j
2643(f) - 23 CCR 16 2643
I
i
V
Underground Storage Tank Program - DW Inspection Report I /-.0
legible and has not been El None
tampered with - 23 CCR ❑ ❑ ® ❑ ❑
16 2717.1 g
2030044 Facility did not allow for
I
deposit of petroleum into
a UST that has a red tag El ❑ ❑ ❑ None j
affixed to the fill - 23 CCR
i
16 2717.1
Install /Repair
2060024 UST system is made of or
lined with materials that
are compatible with the ® ❑ ❑I E] ❑ None
substance stored - 23 !
CCR 16 2631.1 ! !
2060021 Striker plate installed and
positioned correctly - 23 ❑ ❑ ❑ ® CI ❑ None !
CCR 16 2631(c), 2662(g
® There were no violations noted for this inspection.
!
serve as a "NOTICE TO COMPLY" for Minor Violations, and a "NOT I E OF' VIOLATION" for
❑This report shall i
Major violations. You are, hereby, ordered to corlrect the above noted violations within 3 days, or according to
correction summaries provided. Formal enforcement and /or penalty assessment may initiated for any
violations noted, and for those not corrected in a timely manner. (NOTE: If this is a preliminary report, a final report
will follow.) ! !
! -r
Inspectors Signature: :.Date: r-
Inspector: Enter # of Violations: RD: RP:
Check one box for facility Significant Operational Status (SOC) to be reported to SWRC13 an US EPA:
F-1 SOC Detection and Release etection (Facility has no Release Prevention and no Release
SOC with both �
Prevention Violations) i.
❑ Not in SOC (Facility has both Release Prevention and Release Detection Violations)
SOC with Release Detection only (Facility has nd Release 'Detection violations but one or ore elease Prevention
violations) !
❑ SOC with Release Prevention only (Facility has io Release Prevention ;violations but one c r mor Release Detection
violations)
I
Underground Storage Tank Program - DW Inspection Report
j v 2.0
I