Loading...
HomeMy WebLinkAbout1999 TAFT HWY FI 6.24.15FIRE PREVENtION INSPECTION 4 FIRE BAKERSFIELD FIRE DEPARTMENT Prevention Services 2101 H Street Bakersfield, CA 93301 Phone: 661- 326 -3979 • Fax: 661 -852 -2171 DISTRICT BLOCK NO. DATE EE 5 ..44 FACILITY- ADDRESS CITY, STATE, ZIP �y FACILITY NAME f - t _ / 11Y(.A i U � i i ;. ( X75 .MANAGERS NAME d d -'t .¢? /,Iti PH NO. s- F ! )�J I c? BUSINESS OWNER'S NAME AND ADDRESS 'CITY, STATE, ZIP PH NO. BILL TO: (IF DIFFERENT FROM ABOVE) NAME, ADDRESS CITY, STATE, ZIP, PH NO. OCC TYPE OCC' LOAD NO. OF FLOORS HIGH RISE BLDG RISER DATE 13 YES ,© NO CORRECT ALL VIOLATIONS VIOLATION REQUIREMENTS CHECKED BELOW NO. 1 Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises (CFC COMBUSTIBLE WASTE / DRY VEGETATION 304.1'1) 2 Provide non - combustible containers with tight fitting lids for the storage of combustible waste and rubbish pending its safe disposal. (CFC 304.3.2) Note: applies_ to containers over, 40 gallons. COMBUSTIBLE STORAGE 3 Relocate combustible storage to provide at least 3 feet clearance around motor fuse box /fire door (CFC 605.3) r 4 Relocate fire extinguisher(s) so that they will be in a conspicuous location, hanging on brackets with the top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9) EXTINGUISHERS 5- Provide and install (amount) _____ approved (type & size) ______________ portable fire extinguisher to be immediately accessible for use in (area) ____________ ___________ ______ (CFC TABLE 906.3(1)) 6 Re- charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and /or after each use, by a person having a valid license or certificate. (CFC 906.2) Provide and maintain "EXIT" sign(s) with letters 6 or more inches in height over each required exit SIGNS (door /window) to fire escape. (CFC 1011) 8 Provide. and maintain appropriate numbers on a contrasting background and visible from the street to r' indicate the correct address of the building. (CFC 505.1) 9 Repair all (cracks /holes /openings) in plaster in (location) _ ___ _ _____ --__ _____ FIRE DOORS/ FIRE SEPARATIONS Plastering shall return the surface to its original fire resistive condition (CFC 703.1) ' 10 Remove /repair (item & location) --------------------------------------------------------- Self- closing doors,shall be designed to close by gravity, or by the action of a mechanical device, or by an approved smoke and heat sensitive device. Self- closing doors shall have no attachments capable of preventing:;the operation.of the closing device. (CFC 703.2) Exrrs 11 Remove aFl ^obstruction from hallways. Maintain all means of egress free of any storage, (CFC 10.28.3) <12 Provide a contrasting colored and permanently installed electric light over or near required exit :.(location) _______ _______________ to clearly indicate it as an exit. (CFC 1006.3) j STORAGE 13 Remove all storage and /or other obstructions from fire escape, landings and stairways stair shafts. (Fire escapes /stair shafts are to be maintained free from obstructions at all times.) (CFC 1003.6) s ° 14 a Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved ELECTRICAL APPLIANCES electrical outlets where needed. (CFC 605.5) . 15 Remove multiple attachment cords from specific electrical convenience outlet Gone plug per outlet) (CFC 605.4) .OUTDOOR BURNING 16 Recreational fires or open burning. CFC 307.1 FIREWORKS '(B.M.C.). X17 ew Violations of Section (CFC 5608.1) & 8.44.040 OTHER 1 t �3 ?�: i f o- t .5 (ice. j Y 7 f i }fir %' -i :f L i✓' 4,.L f1'. A, l r� CORRECTION DATE — Correct the violations noted above b =,: -: �t�, , , y : '?_ i / %} 17 .�.. ``�""" - . ~� �' i'' f x LEGEND: C.F.C. CALIFORNIA FIRE CODE - C.B.C. CALIFORNIA BUILDING CODE CUSTOMER: ' tom/ — # -- • F (Signature) (Please Print Name Legibly, Tithe) B.M.C. BAKERSFIELD MUNICIPAL CODE N.F.P.A. NATIONAL FIRE PROTECTION /._ INSPECTOR: r - 4t�� NO.; ASSOCIATION N.E.C. NATIONAL ELECTRIC CODE FD 2022 (Rev. 06/14) White - Customer /Original Yellow.- Station Copy Pink Prevention Services 1yl ► 0 A 1 Owner /Operator: F — ✓ r1 Address: -- J71. There were NO violations.observed during this inspection. Notice to Comply. Minor Violations were found during this inspection as noted in the following Summary.of Violations. The violations indicated in .this inspection report. must be corrected within 30 days, umess otherwise noted. _ Formal enforcement may be initiated for any violations noted; and for those not corrected in a timely manner. This report does not represent that there are no other violations at this facility. A re- inspection may occur to determine compliance status: White' Business Copy Yellow — Business Copy to be sent in after Return -to- Compliance Pink - Prevention ServiEes copy SUMMARY OF VIOLATIONS Item REQUIREMENT FOR CORRECTION OF DATE. FOR VIOLATION # VIOLATION CORRECTION C frf l � �.:. 7' �fl % � u X'i _s (r 1�/ I`.. ✓�/�— ✓ r J� J �"+ti.d �'�"'°� '" f ^. k :� .v`` %g r f 1 ,! � � • t, � � '�L:: r `...� r ! . f40.,. .✓,�T --.... � C � <; f ,7-' Inspectors . J.,: ' �- Received by: -_ Signature: h Phone: _ s .X41,: -7T �, nt Name: r k ^ -- 77 r tl ;. Date: Date: CERTIFICATION OF RETURN TO COMPLIANCE White' Business Copy Yellow — Business Copy to be sent in after Return -to- Compliance Pink - Prevention ServiEes copy