CORRECT ALL VIOLATIONS VIOLATION
REQUIREMENTS
CHECKED BELOW No:
Remove safely dispose of all hazardous refuse and dry vegetation on the above premises (U.F.C.,)
1'
and
COMBUSTIBLE WASTE / DRY
VEGETATION
Provide non- combustible containers with tight fitting lids for the storage of combustible waste and -rubbish pending its
2
safe disposal. (U.F.C.)
Relocate combustible storage to provide at least 3 feet clearance around motor fuse box /fire door. (N.E.C.) - (U.F.C.)
COMBUSTIBLE STORAGE
3 .
q
Relocate fire extinguisher(s) so that they will be in a conspicuous. location, hanging' on brackets with the.,, top to the .
extinguisher not more than 5 feet above the floor. (N.F.P.A. No. 10)
EXTINGUISHERS
5
Provide and install (amount) __ approved (type &size) _ ___ -- ---- portable fire extinguisher to be:
- - --
immediately accessible for use in ( area) _____ _______ ______ _____ __ ____ (U.F.C;)
g
Re- charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year," and /or after each uses
by a person having a valid license or certificate. (U.F.C.) -
Provide and maintain "EXIT" signs) with letters 5 or more inches in height over each required e xit. (door /window) to
SIGNS
7
fire escape.. (U.F.C.)
g
Provide and maintain appropriate numbers on a contrasting background.,and visible from the street to indicate the
correct address of the building. (B.M.C.) (U.F.C.)
g
Repair all ( cracks /holes /o enin s ) in plaster in ( location ) Plastering
--------------- ________
FIRE DOORS
shall return the surface to its original fire resistive condition. (U.B.C.)
FIRE SEPARATIONS
10
Remove /repair (item & location) _______ ___ _______ ____ _ _ _ ___ __ -------- ----------- Self - closing ,
doors shall be designed to close by g' ravity, or by the action of a mechanical device or by an approved smoke and
heat sensitive device. Self- closing doors shall have no attachments capable of preventing the operation of the
closing' device. (U.F.C.)
11
Remove all obstruction from hallways. Maintain all means of egress free of any storage. .(U.F.C.)
EXITS
12
Provide a contrasting colored and permanently installed electric light over or near required exit (location) :
to clearly indicate it as an exit_ (U.F.C.)
STORAGE
13
Remove all storage and /or other obstructions from fire escape landings and stairways stair shafts.. (Fire
escapes /stair shafts are to be maintained free from obstructions at all .times.) (U.F.C.)
14
Extension cords shall not be used in Lieu of permanent approved wiring. Install additional approved electrical outlets.
ELECTRICAL APPLIANCES
where needed. (N.-E.C.) ('U.F.C.)
15
Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (N.:E.C.). (U. F. C.)
OUTDOOR BURNING
16
Violation -of Section 1102 dealing with recreational fires or open burnin U.F.C.
FIREWORKS
17
Violations of Section 7802 U.F.C. or 8.49.040 of the Bakersfield Municipal Code B.M.C. regarding fireworks.
OTHER
18
f
CUSTOMER:
LEGEND:
C.F.C. CALIFORNIA FIRE CODE
,(Signature) (Please Print Name Legibly, Title)
U.B.C. UNIFORM BUILDING CODE
B.M.C. BAKERSFIELD MUNICIPAL.CODE
N.F.P.A. NATIONAL FIRE PROTECTION
INSPECTOR: `• e s'' t AP NO.:
ASSOCIATION
(Slg tUCe)
N.E.C. NATIONAL' ELECTRIC CODE:
KU1s 13zu -
White — Customer /Original Yellow - Station Copy' Pink — Prevention Services FD 2022 (Rev. 09/05)