CORRECT ALL VIOLATIONS VIOLATION.
REQUIREMENTS
CHECKED BELOW No.
Remove an d safely dispose of all hazardous refuse and dry vegetation on the above premises (U.F.C.)
1
COMBUSTIBLE WASTE / DRY
VEGETATION
2
Provide non - combustible containers with tight fitting lids for the .storage of combustible waste and rubbish pending its
safe disposal. (U.F.C.)
COMBUSTIBLE STORAGE
3
Relocate combustible storage to provide at least 3 feet clearance around motor fuse box /fire door (N.E.C.,) (U.F.C.)
4
Relocate fire extinguisher(s) so that they will be. in a conspicuous location, hanging on brackets with the top to the .
extinguisher not more than 5 feet above the floor. (N.F.P.A. No. 10)
EXTINGUISHERS
5
Provide and install (amount) ..... approved (type & size) ___ _____ ___ portable fire`.extin.guisher to be
immediately accessible for use in (area) _______ _____ ___ ________ _ __ ___ (U.F.C.)
6
Re- charge all fire extinguishers. -Fire extinguishers shall be serviced at least once each year, and /or after. each use,
y a person having a valid license or certificate. I (U. F.C.)
7
Provide and maintain "EXIT" sign(s) with letters 5 or more inches in height over each required exit (door /window) to
SIGNS
fire escape. (.U.F.C.)
8
Provide and maintain appropriate numbers on a contrasting background and visible from the street to indicate the
correct address of the building. (B.M.C.) (U.F.C.)
g
Repair all (cracks /holes /openings.) in plaster in (location) ------------------------- _--- ------ _---- Plastering
FIRE DOORS I
shall'return the surface to its original fire resistive condition. (U.B.C.)
FIRE SEPARATIONS
10
___ __ ___ _________ __ ____ _____ ____ __ _ -__ - -_ _________• Self- closing
Remove /repair (item & location) -------------------------------------------------- ---------
doors shall be designed to close by gravity, or by the action of a mechanical.device, or by an approved smoke and
heat sensitive device. Self - closing doors shall have no attachments capable of preventing the operation of the
closing device. (U.F.C.)
11
Remove all obstruction from hallways. Maintain all means of egress free of.any storage. .(U.F.0 ..)
EXITS
12
Provide a contrasting colored and permanently installed electric light over or near required exit (location)
to clearly indicate it as anexit. (U.F.C.)
STORAGE
13
Remove all storage and /or other obstructions from fire escape landings and stairways stair shafts. (Fire
escapes /stair shafts are to be maintained free from obstructions at all times.) (U.F.C.)
1.4
Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved electrical outlets
ELECTRICAL APPLIANCES
where needed. .(N.E.C.) (U.F.C.)
15
Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (N.E.C.) (U.F.C.)
OUTDOOR BURNING
16
Violation of Section 1102 dealing with recreational fires or open burning. U.F.C.
FIREWORKS
17
Violations of Section 7802 U.F.C. or 8.49.040 of the Bakersfield Munici Gode B.M.C. regarding fireworks.'
OTHER
$
t
aw. ✓X
l h
b
CUSTOMER: of f .f tr r"'' -fr
LEGEND:
C.F.C. CALIFORNIA FIRE CODE
Y g nature) , (Please Print Name Legibly, Title)
S
U.B.C. B.M.C. UNIFORM S AL CODE .
BUILDING ODE
INSPECTOR: AP NO.:
N.F:P.A. NATIONAL FIRE PROTECTION
(Signatr�re)
ASSOCIATION
N:E.C... NATIONAL ELECTRIC CODE- .
Knr -iszu
White — Customer /Original Yellow - Station Copy Pink — Prevention Services FD 2022 (Rev. 09/05)