CORRECT ALL VIOLATIONS vioLATION
REQUIREMENTS
CHECKED BELOW No:
1
Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises (U.F.C;)
COMBUSTIBLE WASTE h DRY
VEGETATION
Provide non- combustible containers with tight fitting lids for the storage of combustible waste and rubbish pending its
2
safe disposal. (U.F.C.)
COMBUSTIBLE STORAGE
3
Relocate combustible storage to provide at least 3 feet clearance around motor fuse box /fire door (N.E:C,) - (U F.C.)
4
Relocate fire extinguisher(s) so that they will be in a conspicuous location, hanging on brackets with the top to the
extinguisher not more than 5 feet above the floor. (N.F.P.A. No. 10)
EXTINGUISHERS
5
Provide and install (amount) _____ approved (type & size) _ ___ ---------- portable fire extinguisher to be
immediately accessible for use in ( area) __ ___________________________ (U.F.C.)
6
Re- charge all fire extinguishers, Fire extinguishers shall be serviced at least once each year, and /or after each;use
by a' person having a valid license or certificate.: (U.F.C.)
7
Provide and maintain "EXIT" s.ign(s) with letters 5 or more inches in height over each required exit ( -doo.r /window) to
SIGNS
fire escape. (U.F.C.)
g
Provide and maintain appropriate. numbers on a contrasting background and visible from, the street to. indicate the "
correct address of the building. (B.M.C.) (U.F.C.)
9
Repair all (cracks /holes /openings) in plaster in (location)__ ___ _-------- _--------- _------- Plas- tering
FIRE DOORS /
shall return the surface to its original fire resistive. condition. (U.B.C.)
FIRE SEPARATIONS
10
Remove /repair (item & location.)'______________, ____________- ______________ -___ ___— _____� Self= closing
doors shall be designed to close by gravity, or by the action of a mechanical device, or by an approved s -moke and
heat sensitive device. Self- closing doors shall have no attachments capable of preventing the operation of the
closing device. (U.F.C.)
11.
Remove all obstruction from hallways. Maintain all means of egress free of any storage. (U.F.C.)
EXITS
12
Provide a contrasting colored and permanently installed electric light over or near required exit.(location)
to clearly indicate it as an exit. (-U.F.C.)
STORAGE
93
Remove all storage and /or other obstructions from fire escape landings and stairways stair shafts. (Fire
escapes /stair shafts are to be maintained free from obstructions at all times.) (U.F.C.)
14
Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved electrical. outlets
ELECTRICAL APPLIANCES
where needed. (N.E.C.) (U.F.C.)
15
Remove multiple attachment cords from specific electrical convenience outlet, (one plug per outlet) (N.E.C.) (U.F.C.)
OUTDOOR BURNING
16
Violation of Section 1102 dealing with recreational fires or.o en burning. U.F.C.
FIREWORKS'
17
Violations of Section 7802 U.F.C. or 8.49.040 of the Bakersfield Municipal Code B.M.C. regarding fireworks.
OTHER
1$,
I
F
jvu
€�
LEGEND:
CUSTOMER:
C.F.C. CALIFORNIA FIRE CODE ;
lgnature) (Please Print Name Legibly, Title)
U.B.C'.. UNIFORM BUILDING CODE
B.M.C. BAKERSFIELD MUNICIPAL CODE
INSPECTOR; r AP NO.;
N.F.P.A. NATIONAL FIRE PROTECTION
(Slg Ure)
ASSOCIATION
N.E.C. NATIONAL ELECTRIC CODE
Krsr-iszu _
White - Customer /Original Yellow - Station Copy Pink - Prevention Services FD 2022 (Rev. 09/05)