HomeMy WebLinkAboutFIRE INSPECTION 8.13.19N BAK noon Services FIRE DEPARTMENT FIRE PREVENTION INSPECTION Prevention Services Street Bakersfield, •� CA 93301 Phone: 661 - 326 -3979 B Fax: 661- 852 -2171 FACILITY ADDRESS LLm LANE _ CM, STATE, ZIP e NEa6 OWNERS NAME AND ADDRESS Es„NADENS MARC &,(i 9> �z3— BILL M: (IF DIFFERENT FROM ABOVE) NAME, ADDRESS CITY, STATE, am pry NO. OCC TYPE OSC LOpO NO. OF FLOOR6 oC[ Y6E pI .. DATA n . Z C wa[ /Dry Sprinkler SyWm TYpA eFAlerm 6Wlem COXSTIUCRON TYPE ON PIRA ALL. Sp /IT OCELD J ❑xYES ❑ NO CORRECT v SEOUL REMENT6 eeiVIOLATIONS eow NO. 1 Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises (CFC omanuma6ry .I pary c 304.1.1) I Pro vice non - combustible containers with tight fitting lids for the storage of combustible waste And rubbish pending its safe disposal. (CFC 304.3.2) Note: applies to containers over 40 gallons. mweusrseLE equouE 3 Relocate combustible storage to provide at least 3 feet clearance around motor fuse box /fire door (CFC 605.3) 4 Relocate fire extinguisher(s) so that they will be In a conspicuous location, hanging on brackets with the tap to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9) exnNDUSxeRS 5 Provide and install (amount) _ _ approved (type & size) portable fire extinguisher to be Immediately accessible for use In (area) — _ (CFC LE 906.3) charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and /or r each use, by a person having a valid license or certificate. (CFC 906.2) vide antl maintain "EXIT" slgn(s) with letters 6 or more inches In height over each required exit or /window) to fire escape. (CFC 1011) T vitle and maintain appropriate numbers on a Contrasting background and visible from the street to cate the correct address of the building. (CFC 505.1) air all (cracks /holes /openings) In plaster In (location) — __ _______ — — — ___-- - - -___ tering Shall return the surface t0 its Original fire resistive Condition. (CFC 703.1) ove /repair (item & location) - closing doors shall be designed to close by gravity, or by the action of a mechanical device, or by an approved smoke and heat sensitive device. Seif- closing doors shall have no attachments capable of preventing the operation of the closing device. (CFC 703.2) 11 Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1031.1) euTa 1z Provide a contrasting colored and permanently Installed electric light over or near required exit (location) _ to clearly indicate it as an exit. (CFC 1008) smRA6e 13 Remove all storage and /or other obstructions from fire escape landings and stairways stair shafts. (Fire escapes / stair shafts are to be maintalned free from obstructions at all times.) (CFC 1003.6) 14 Extension cards shall not be used In lieu of permanent approved wiring. Install additional approved ELErn MAPpLw electrical outlets where needed. (CFC 605.5) 15 Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (CFC 605.4) omooaa wpxwD 16 Recreational fIr r o en burns CFC 307 ImlewDRxz 17 Violations of Section (CFC 5608.1) & B.44.040 (B.M.C.). OTxeR IN CORRECTION DATE Correct the violations noted above by: ' CUSTOMER: C.GEXO: C. C. CALIFORNIA BUILDING C6.0. CALIFORNIA BUILOIXG CODE (SlgnaWrt) ( %ease Print Name Si k Y. ) B.M.C. BARERSHELD MUNICIPAL CODE t-LJ NO.: N.RP.A. PROTECTSON INSPECTOR: I r T�-L E ASSOCIATION / N.E.O. NATIONAL ELECTRIC CODE White - Prevention Services Yellow - Station Copy Pink - Business Copy W MR IRev. w/N191