HomeMy WebLinkAboutFIRE SAFETY INSPECTION 9.19.19FIRE PREVENTION INSPECTION BAK Prevention FIRE DEPARTMENT /' ®1 Prevention Services (,P 2101 H Street Bakersfield, CA 93301 Phone: 661-326-3979. Fax: 661 -852 -2171 MLELLTY !E MCELLTY RARE earl, BrArl ka. 9UCIXER.90WXM'S NANI AND ADDRESS XAC 10.9 NIJIC PM NO. SOL TO! (IF WPFIRENT F0.0x AROv!) RARE, ADDRESS carry, 'A'IIP PN NO. OCC TYPE OCC LORD NO.OF FLOORS Doc USE .. sme wet /ory sPrinkler 6ptem so T,, 11 Al­ axall CONSrRY[TIOx '. RIEe BLOO Sg /F ALD ' Ci YES Ir NO v / , C. Re Re ALL Vrounons n RegvlRexlxTs LXK NI BELOW xPi O D Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises (CFC Coo.. .. wRSrt /SAY 3D4. 1.1) VVERIATION z Provide non -combustible containers with tight fitting lids for the storage of combustible waste and rubbish pending Its safe disposal. (CFC 304.3.2) Note: applies to containers over 40 gallons. to at least 3 feet clearance around motor fuse box /fire door (CFC wneusruLE Bow. 3 Relocate combustible storage provide 605.3) 4 Relocate fire extingulsher(s) so that they will be In a conspicuous location, hanging on brackets with the top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9) ExrMGVIDxERS 5 Provide and install (amount) _ approved (type & size) — —_— portable fire extinguisher to be Immediately accessible for use In (area) - ____ ___ — (CFC TABLE 906.3) Re- charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and/or 6 after each use, by a person having a valid license or certificate. (CFC 906.2) Provide and maintain "EXIT- slgn(s) with letters 6 or more Inches In height over each requ red exit ..a T (door /window) to fire escape. (CFC 1011) Provide and maintain appropriate numbers on a contrasting background and visible from the street to a indicate the correct address of the building. (CFC 505.1) 9 Repair all (cracks /holes /openings) In plaster in (location) as examaAimxS Plastering shall return the surface to its original fire resistive condition. (CFC 703.1) 10 Remove /repair (Item & location) _ — __ __ - -- - - - - - -- — device, by an Self- closing doors shall be designed to close by gravity, or by the action of a mechanical or approved smoke and heat sensitive device. Self- CIDSing doors shall have no attachments capable of preventing the operation of the closing device. (CFC 703.2) 11 Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1031.1) comas 1z Provide a contrasting colored and permanently installed electric light over or near required exit (location) t0 clearly indicate it as an exit (CFC 1008) _ Remove all storage and/or other obstructions from fire escape landings and stairways stair shafts. (Fire MANE 13 escapes /stair shafts are to be maintained free from obstructions at all times.) (CFC 1003.6) Extension cords shall not be used In lieu of permanent approved wiring. Install additional approved ELECTRICAL ARPLIBNCER 14 electrical outlets where needed. (CFC 605.5) 15 Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (CFC 605.4) oUnNUOR BURNING 16 R cr 'ones I s or en burnin PC 07.1 Faewaexz 17 Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.). o Xee 10 CORRECTION DATE Correct the violations noted above by: CUSTOMER] ♦ LEGEND: C.P.L. CALIFORNIA Fl C.B.C. CALIFORNIA BUILDING CE (Signature) TUe) a.N.C. BAKERSFIELD MU ICIPAL LO G E NO.: N.PA.A. NATIONAL FIRE PROTERON INSPECTOR: AsspcunIME! x.e.c. xnnaxAL eLenuc CODE White - Prevention Services Yellow - Station Copy Pink - Business Copy no xsu iR«. gulps»