Loading...
HomeMy WebLinkAboutFIRE SAFETY INSPECTION 9.25.19^, BAKERSFIELD FIRE DEPARTMENT FIRE PREVENTION INSPECTION Prevention Services 2101 H Street � � Bakersfield, CA 93301 Phone: 661- 326 -3979 R Fax: 661 - 852 -2171 Fgnlm ADDRESS -/� S / qR FACILITY MAKE r1 °3. m, aw,e, air BUSINESS OWHIR'S XgNE AND ADDRESS eR'S XAMC PNNO. BILL mi (IF DIFFERENT FARM ABOVE) NAME, ADDRESS r, STATE,ZID P. .D. Occ �PE 2 O&LOAD FLOORS act EE KOREA DATE weVDry 3PRIDEr STN.m TEP•wu..msnum CONSTRUCnoN TnE NtOx RISE ROAD DRIFT OF ALD ❑ YES CI NO CORRECT ALL VIOLATIONS W RIQUIRENlXl3 O BELOW .0. CONNSU BE WASTE /DRY 1 Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises (CFC 384.1.1) S0N 2 Provide non - combustible containers with tight fitting lids for the storage of combustible waste and rubbish pending its safe disposal. (CFC 304.3.2) Note: applies to containers over 40 gallons. xeamINE sTORAOE 3 Relocate combustible storage to provide at least 3 feet clearance around motor fuse box /fire door (CFC 605.3) a Relocate fire extinguisher(s) so that they will be In a conspicuous location, hanging on brackets with the top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 8 906.9) zrmOU.. 5 Provide and Install (amount) - approved (type & size) portable fire extinguisher to be Immediately accessible for use in (area) - - -_ — _ ______ — (CFC TABLE 906.3) 6 Re- charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and/or after each use, by a person having a valid license or certificate. (CFC 906.2) smxs 7 Provide and maintain "EXIT" sigh(s) with letters 6 or more Inches in height over each required exit (tloortwindow) to fire escape. (CFC 1011) e Provide and maintain appropriate numbers on a contrasting background and visible from the street to indicate the correct address of the building. (CFC 505.1) ,a.. ODORS/ 9 Repair all (cracks /holes /openings) In plaster in (location) Plastering shall return the surface to its original fire resistive condition. (CFC 703.1) MRE SePAR.vmxs 10 Remove /repair (Item R location) _____ ___ —_ - Self- closing doors shall be designed to close by gravity, or by the action of a mechanical device, or by an approved smoke and heat sensitive device. Self - closing doors shall have no attachments capable of preventing the operation of the closing device, (CFC 703.2) 11 Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1031.1) eDs II Provide a contrasting colored and permanently Installed clear electric a it over or near (CFC required exit (location) - __— [o clearly Indicate it as an exit (CFC 1008) STORAGE 13 Remove all storage and/or other obstructions from fire escape landings and stairways stair shafts. (Fire escapes /stair shafts are to be malntalned free from obstructions at all times.) (CFC 1003.6) eLecrRlcu AFPDAN.A 14 Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved electrical outlets where needed. (CFC 605.5) 15 Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (CFC 605.4) OUIOOOR BURNING 16 Recreational fires or Into gumpa. MEC bur 07.1 F[REWmlxs it Violations of Section (CFC 5608.1) A 8.44.040 (B.M.C.). OTIOL 18 CORRECTION DATE Correct the violations noted above by LEGEND: CUSTOMER: Y ' C.F.C. CALIFORNIA "RE CODE C.B.C. CALIFORNIA BUILDING CODE B.M.C. BAKERSFIELD MUNICIPAL CODE N.F.P.A. NATIONAL UCLATION E PROTECTION ($IJnature) (Please PtlrR Neme Lplby. TLE) INSPECTOR: V NO" Ll x H.E.C. NATIONAL ELECTRIC CODE White - Prevention Services yellow - Station Copy Pink - Business Copy Fo xoaz tFau. Dvzoesl