Loading...
HomeMy WebLinkAboutFire Safety 11-15-19_10-10FIRE PREVENTION INSPECTION BAKERSFIELD FIRE DEPARTMENT Prevention Services 2101 H Street BakerSFleld, CA 93301 Phone: 661-326-3979 x Fax: 661-852-2171 FsclLm aaoneae ` __TC iiBRT, ( EE eeLlTr XnxF 1 Em, 6reTE, FIP L �'• BUSINESS OWNER'S NAME AND ADDRESS .ARE '6 PHNO. LTO: pF DIFFERENT FROM ABOVE) NAM, ADDRESS CITY, STpF, ZIP PH NO. OLC TPEOCR AD NO.OF PLOOR6 O I6E0. GATE L !. WMID, SIOrNINI 6Yrtem Ty PE Er A1vm 6YRxo COXRomernON TVPeNISE BLDG Sp/PT OF BLD NYES ❑ ❑ NO CORRECT ALL vrounoxs VIOLA ONREuwx6xrrv'rs CHEERED 9ELOw not Remove and safely dlspo5e of all hazardous refuse and dry vegetation on the above premises (CFC CONeuwrBte wAsrt/DRv 304.1.1) VE6ETPTION Z Provide non-combustible containers with tight fitting lids for the storage of combustible waste and rubbish pending its safe disposal. (CFC 304.3.2) Note: applies to containers over 40 gallons. MR UMm R E 3 Relocate combustible storage to provide at least 3 feet clearance around motor fuse box/fire door (CFC 605.3) 4 Relocate fire extingulsher(s) 50 that they will be In a conspicuous location, hanging on brackets with the top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9) FFrwaureNNa 5 Provide and Install (amount) __ _ approved (type & size) —__— portable fire extinguisher to be Immediately accessible for use in (area) (CFC TABLE 906.3) Recharge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and/or after each use, by a person having a valid license or certificate. (CFC 906.2) Provide and maintain "EXIT" sign(s) with letters 6 or more Inches In height over each required exit PHONE 7 (door/window) to fire escape. (CFC 1011) Provide and maintain appropriate numbers on a Contrasting background and visible from the street to a indicate the correct address of the building. (CFC 505.1) D Repair all (Cracks/holes/openings) In plaster In (location) ______ _____— —__—__ ______ __ Futs P...A Plastering shall return the surface to Its original fire resistive condition. (CFC 703.1) FIRE SEPARoxs 30 Remove/repair (Item & location) ----------- ----- ____ - ------ _ ---- by an Self-closing doors shall be designed to close by gravity, or by the action of a mechanical device, or approved smoke and heat sensitive device. Self-closing doors shall have no attachments capable of preventing the operation of the closing device. (CFC 703.2) 11 Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1031.1) eu R 12 electric over near required exit Provide a contrasting colored and permanently Ito a It ex 1008 to clearly indicate It as an exit (CFC 1008) (location) clear .. _..... ___ — Remove all storage and/or other obstructions from fire escape landings and stairways stair shafts. (Fire EtOM6E 13 escapes/stair shafts are to be maintained free from obstructions at all times.) (CFC 1003.6) Extensions not lieu f5ermanen[ approved wiring. Install additionalapprovetl eLECIRIuupPWxrzs electrical outletswhere needed. (CFC605) 15 Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (CFC 605.4) DUIDoOR sumw6 16 gecrqAtionalfires en turpirm. (CFC 07.1 FREwq(Rs 17 Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.). omen 18 ) .r'= le`1' 1 CORRECTION DATE Correct the violations noted above by: 7) CUSTOMER: —_I EGEND: C.P.L. CALIFORNIA FIRE CODE L.B.C. ODE ngyrB) (BEAUS Print Neme Legibly, Ttle) LCO BAKERSFIILD MUNICIPAL B.M.C. BMKFRFFIELa NIINICIPRL CODE Aoe ' NO.: 19 -S X.FP.A. NATIONAL FIRE PROTECTION INSPECTOR:.1 Eo� ASEOCIATIOX X.E.C. NATIONAL ELECTRIC CODE White - Prevention SCNICes Yellow - Station Copy Pink - Business Copy W 20321REe D3I1PI9)