HomeMy WebLinkAboutCUPA 11-14-19Underground Storage Tank Program / f
DW Inspection RepeFt`�q,
Permission to Inspect
BAKERSFIELD FIRE DEPARTMENT
Prevention Services Division
2101 H Street
Bakersfield, CA 93301
Phone: 661-326-3979
Fax: 661-852-.2171
Business Name: JIM BURKE FORD 15-021-003107
Date: 11/14/2019 CAD981441728
Address Name: 2001 OAK. ST BAKERSFIELD, CA 93301
Inspector Name: Peter Armagost#8856813
Inspection Type: Routine
Report: Final
NVO =No Violation Observed OUT= Out of Compliance NA =Not Applicable UD = Undetermined
COS = Corrected On Site RPT =Repeat Violation
Violation
Program Requirement
0 1
SOC
Comments
No
D
mg
z
O
z
oy'
File Review
Facility Tank Information
2030021
Facility has a valid Permit
Tank 1 -11430 -REG -DW
to Operate from the
®
❑
❑
❑
❑
❑
None
CUPA - 23 CCR 16 2712(1);
HSC 6.7 25284
2010010
UST Operating Permit
Application for Facility
information and Tank
information
®
❑
❑
❑
❑
❑
None
submitted/maintained - 23
CCR 16 2711; HSC 6.7
25286(a
2010001
Current BOE number
submitted to the CUPA
®
❑
❑
❑
❑
❑
None
and/or CERS - HSC 6.7
25286(c)
2030011
UST compliance
statement and/or
Designated Operator
®
❑
❑
❑
❑
❑
None
current certification
submitted - 23 CCR 16
2715(a), 27156
2030046
A complete and accurate
response plan has been
submitted, approved and
®
❑
❑
❑
❑
❑
None
maintained - 23 CCR 16
2632, 2634(e), 2641(h),
27121
2030041
A complete and accurate
plot plan has been
submitted, approved and
®
❑
❑
❑
❑
❑
Minor
maintained - 23 CCR 16
2632 d 1 C, 2717 a 8
2010006
Owner/Operator has not
made false statements or
representation on any
®
❑
❑
❑
❑
❑
None
required document- HSC
6.7 25299
2010003
Owner/Operator has a
DO and/or informed the
CUPA of any change (s)
®
❑
❑
❑
❑
❑
None
within 30 days - 23 CCR
162715(a)
Testing
Violation
Program Requirement
01
SOC
Comments
NO
T q
z
O
z
0
0
K
p>
2030002
Owner/Operator has
tested and certified leak
®
❑
❑
❑
❑
❑
None
detection equipment
annual) -23 CCR 16 2638
2030048
Secondary containment
testing conducted every
36 months in accordance
®
❑
❑
❑
❑
❑
None
with requirements - 23
CCR 16 2637
2030055
Spill buckets have been
tested annually as
®
❑
❑
❑
❑
❑
None
required - HSC 6.7 25284,2
2010009
Secondary containment
test results submitted to
the CUPA within 30 days
®
❑
❑
❑
❑
❑
None
after the test - 23 CCR 16
2637(e)
2030064
CUPA was poperly
notified within the
prescribed number of
®
❑
❑
❑
❑
❑
None
hours prior to testing - 23
CCR16 2637(f), 2638(e),
2643 , 2644.1(a)L4)
Install/Repair
2060009
Permits obtained to
install, replace, repair, or
®
❑
❑
❑
❑
❑
None
modify part of the UST
system - 23 CCR 16 2712
UST System Observation
General Monitoring
2030003
Leak detection system
maintains continuous
RD
monitoring that activates
®
❑
❑
❑
❑
❑
None
❑
an audible and visual
Yes
alarm - 23 CCR 16 2632,
2030016
2634, 2636, 2666
The annular space of the
Annular Sensor will not reset out
tank, piping and sumps
RD
of alarm. Sensor needs fixed or
replaced.
are continuously
❑
®
❑
❑
❑
❑
None
❑
monitored and activates
the alarm - 23 CCR 16
Yes
2631(9) 2632(c)(2)(A)&(B),
2633 c, 2636
2030017
Product piping outside the
UDC is fail-safe and shuts
down the pump or
®
❑❑
❑
❑
❑
None
restricts flow - 23 CCR 16
2636(0 (5)
2030018
Turbine sump monitor
RD
activates an audible and
visual alarm or stops the.
®
❑
El
El
El
E]
None
❑
flow of at the dispenser -
Yes
23 CCR 16 2636 (0(12
Underground Storage Tank Program - DW Inspection Report v 2'0
Violation
Program Requirement
o.
SOC
Comments
NO
0U
P E5
z
O
z
�
K
�>
2030019
Monitoring system in the.
UDCs activates an
audible and visual alarm
❑
❑
❑
❑
❑
None
or stops the flow at the
UDC - 23 CCR 16
2636 (0(1)
2030043
Leak detection equipment
RD
properly programmed or
properly operated - 23
®
❑
❑
❑
❑
❑
None
❑
CCR 16 2632, 2634, 2636,
Yes
2666
2060005
System constructed with
a monitoring system
capable of detecting entry
®
❑
❑
❑
❑
❑
None
into secondary
containment - HSC 6.7
25291(b)
2060014
Correct leak detection
equipment installed for
RD
the type of system
®
❑
El
El
[:]None
El
present- 23 CCR 16 2638;
Yes
HSC 6.7 25290.1, 25290.2,
25291
2060015
Sensor located in the
RD
proper position/location -
®
❑
❑
❑
❑
❑
None
❑
23 CCR 16 2630(d), 2641(a)
Yes
2030062
Facility is in compliance
RD
with not tampering with or
❑
disabling leak detection
®
❑
❑
❑
❑
❑
None
devices or alarms - HSC
Yes
6.7 25299 a 9
2060022
System constructed with
a monitoring system
capable of detecting entry
®
❑
❑
❑
❑
❑
None
into secondary
containment - HSC 6.7
25290.2(d)
2030034
Tag/sticker on affixed
monitoring equipment
being certified, repaired,
®
❑
❑
❑
❑
❑
None
or replaced - 23 CCR 16
2638
VPH Monitoring VPH
2030065
Interstitial monitoring ofRD
the annular spaces of the
UST is properly
❑
❑
®
❑
❑
❑
None
El
- HSC 6.7
Yes
25290.1 e
2060023
System constructed with
a monitoring system
capable of detecting entry
into secondary
❑.
❑
®
❑
❑
❑
None
containment - HSC 6.7
25290.1(d)
Underground Storage Tank Program- DW Inspection Report v.2.0
Violation
Program RequirementSOC
Comments
No
m_
Line Leak
Detector
2060012
Line leak detector
installed on pressurized
RD
piping system - HSC 6.7
❑
❑
®
❑
❑
❑
None
❑
25290.1(17), 25290.2(g),
Yes
25291(q, 25292(e),
2636 (0(2)
2030026
Line leak detectors detect
a 3 gph leak and/or
RD
audible and visual alarm
❑
❑
®
❑
❑
❑
None
❑
function properly - 23
Yes
CCR 16 2636(/)(6),
2666(c)
2030027
Turbine shuts down when
RD
a leak is detected or
when line leak detector is
❑
❑
®
❑
❑
❑
None
❑
disconnected - 23 CCR 16
Yes
2666(c)
2030025
Pressurized piping ableto
detect a 3.0 gph leak
RD
within an hour, and
❑
❑
®
❑
❑
❑
None
❑
restricts the flow or
Yes
alarms - 23 CCR 16
2636(0(2)
Secondary Containment
2060010
UST storing a hazardous
RD
substance has secondary
®
❑
❑
❑
❑
❑
None
❑
containment - HSC 6.7
Yes
25292
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
v 0
SOC
Comments
No
o
D
a
o
N
o
F-
a
2 ry
v o
Z
O
O
Z
M
Q:O
2030008
UDC, sumps, and/or
other secondary
containment in good
®
❑
❑
❑
❑
❑
None
condition and/or are free
of debris/liquid - HSC 6.7
25290. 1, 25290.2, 25291
2030040
Secondarily contained
RD
piping maintained to allow
®
❑
❑
❑
❑
❑
None
❑
liquid to drain into sump -
Yes
23 CCR 16 2630(d), 2641(a)
2060006
Secondary containment
piping slopes back to the
®
❑
❑
❑
❑
❑
None
collection sump - 23 CCR
16 263(c)
2030047
Secondary containment
maintained tight and has
been confirmed by testing
®
❑
❑
❑
❑
❑
None
- 23 CCR 16 2662, HSC 6.7
25290.1(2)(2), 25290.2(2)(2),
25291(a), 25292(e)
2030060
Entry fittings in secondary
containment for UST
system maintained
®
11
❑
❑
❑
❑
None
tightlsealed - 23 CCR 16
2630,2635(d), 2636(2),
2666
2060020
Spill bucket is installed
RP
and has a functional drain
valve or other means: to
Z
❑
❑
❑
❑
❑
None
❑
remove liquid - 23 CCR 16
Yes
2635(b), 2665
2030054
Spill bucket maintained in
RP
good condition and free of
®
❑
❑
❑
❑
❑
None
❑
debris and/or liquid - 23
Yes
CCR 16 2635(b), 2715(2 2
2060019
Spill bucket to has a
minimum capacity of five
®
❑
TE10
❑
❑
None
gallons - 23 CCR 16
2635(b), 2665
Overfill
2030035
UST system is operated
RP
to prevent unauthorized
®
❑
❑
❑
❑
❑
None
❑
release, including Spills
and overfills - HSC 6.7
Yes
25292,1(a)
2030036
Overfill prevention system
RP
has not been overridden
®
❑
❑
❑
❑
❑
None
❑
and meets overfill
requirements - 23 CCR 16
Yes
2635(b)(2), 2665
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
v,`o_
SOC
Comments
No
00
m
Q
o'2
On Site
Records
Certifications
2030023
Required designated
operators or contractors
maintain a proper and
®
❑
❑
❑
❑
❑
None
current ICC certification -
23 CCR 16 2715
2030024
Service technician,
installer, and/ or
employee maintain a
®
❑
❑
❑
❑
❑
None
proper license - 23 CCR
162715
2030031
Employee orcontractor
obtained and maintained
proper manufacturer
®
❑
❑
❑
❑
❑
None
certification - 23 CCR 16
2715
2010007
Submitlmaintain current
Certificate of Financial
Responsibility/mechanism
of financial assurance-
®
❑
❑
❑
❑
❑
None
23 CCR 16 2711; 23 CCR
18 2808.1, 2809-2809, 2;
HSC 6.7 25292.2; HSC
6.75 25299.30-25299:34
Designated Operator
2010004
Copies of DO inspections
for last 12 months and list
of trained employees
®
❑
❑
❑
❑
❑
None
maintained - 23 CCR 16
2715
2030013
Designated operator
properly conducted the
monthly inspection and
®
❑
❑
❑
❑
❑
None
the reports are complete -
23 CCR 16 2715
2030010
DO notified operator of
any condition observed
during the monthly
®
❑
❑
❑
❑
❑
None
inspection that may
require action - 23 CCR 16
2715(d)
2030012
DO employee training
performed, current for at
least one employee on
®
❑
❑
❑
❑
❑
None
site, and a log kept - 23
CCR 162715(c)(6), 2715
Underground Storage Tank Program - DW Inspection Report ° 2.0
Violation
PrograII! rement
v o
SOC
Comments
No
A
vz
o
z
o0
M
of
Logs
2030001
Leak detection alarm
logs, maintenance and
RD
records ofappropriate
®
[01
101
101
1-1
ElNone
F-1follow-up
actions
Yes
maintained - 23 CCR 16
2632, 2634, 2712(b)
Maintenance/Tests
2010008
Monitoring, maintenance,
repairs, linings, and
RD
upgrade records
Z
❑
❑
❑
❑
❑
None
❑
maintained for the proper
Yes
time period - 23 CCR 16
2712(b)
Documentation
2030033
Failure to maintain on site
an approved monitoring
®
❑
❑
❑
❑
❑
None
plan - 23 GCR 16 2632,
2634, 2711, 2712(1
2030037
Written agreement
between the tank owner
and tank operator to
monitor the tank system
®
❑
❑
❑
❑
❑
None
is maintained - 23 CCR 16
2620(6); HSC. 6.7
25264 a 3
2030061
Suspected or actual
RD
unauthorized release
❑
❑
®
❑
❑
❑
None
❑
reported in appropriate
time frame - HSC 67
Yes
29294, 29295
General Operating Requirements
Permit Condition/Approval
2030039
Compliance with all
operating permit
®
❑
❑
❑
❑
❑
None
conditions - 23 CCR 16
2712, HSC 6.7 25299
2030059
UST system maintained
in accordance with
exclusion/exemption
®
❑
❑
❑
❑
❑
None
status - HSC 6.7 25281.6,
25283.5
2030014
Owner/Operator received
approval and has
implemented a training
❑
❑
®
❑
❑
❑
None
program at an unstaffed.
facility - 23 CCR 16
2715 2
2030015
Facility exhibited that the
method used to monitor
the tank meets the
monitoring methods in
❑
❑
❑
❑
❑
None
2643(f) - 23 CCR 16.2643
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
m o
SOC
Comments
No
O
O
a
P m
Z
O
Q
Z
t]
J
U
K
o>
Red Tag
2030045
Red Tag information is
legible and has not been
❑
❑
®
❑
❑
❑
None
tampered with - 23 CCR
16 2717.1
2030044
Facility did not allow for
deposit of petroleum into
a UST that has a red tag
❑
❑
®
❑
❑
❑
None
affixed to the fill - 23 CCR
162717.1p)
Install/Repair
2060024
UST system is made of or
lined with materials that
are compatible with the
®
❑
❑
❑
❑
❑
None
substance stored - 23
CCR 16 2631.1
2060021
Striker plate installed and
positioned correctly - 23
®
❑
❑
❑
❑
❑
None
CCR 16 2631(c), 2662(d)
❑ There were no violations noted for this inspection.
®This report shall serve as "NOTICE TO COMPLY" for Minor Violations, and a "NOTICE OF VIOLATION" for
Major violations. You are, hereby, ordered to correct the above noted violations within 30 days, or according to
correction summaries provided. Formal enforcement and/or penalty assessment may be initiated for any
violations noted, and for those noA corrected in a timely manner. (NOTE: If this is apreliminary report, afinal report
will follow)
Inspectors Signature: �I�A "��- Date: tf 1
uopw.. I........ .............
Check one box for facility Significant Operational Status (SOC) to be reported to SWRCB and US EPA:
❑ SOC with both Release Detection and Release Detection (Facility has no Release Prevention and no Release
Prevention Violations)
❑ Not in SOC (Facility has both Release Prevention and Release Detection Violations)
❑SOC with Release Detection only (Facility has no Release Detection violations but one or more Release
Prevention violations)
❑ SOC with Release Prevention only (Facility has no Release Prevention violations but one or more Release
Underground Storage Tank Program - DW Inspection Report v 2.0