Loading...
HomeMy WebLinkAboutCUPA 12-19-19Underground Storage Tank P ogram p DW Inspection Re Permission to Inspect: BAKERSFIELD FIRE DEPARTMENT Prevention Services Division 2101 H Street Bakersfield, CA 93301 Phone: 661-326-3979 Fax: 661-852-2171 Business Name: CIRCLE K STORE 2701270 15-021-002959 Dale: 12/19/2019 CALOOD278585 Address Name: 5634 STINE ROAD BAKERSFIELD, CA 93313 Inspector Name: Peter Armagost #8856813 Inspection Type: Routine Report : Final NVO = No Violation Observed OUT = Out of Compliance NA = Not Applicable UD = Undetermined COS = Corrected On Site RPT =Repeat Violation Violation Program Requirement ° `o SOC Comments No O Q O O a v,o z O z U a O 1 File Review Facility Tank Information 2030021 Facility has valid Permit Tank 1 -14976 -REG -DW to Operate from the❑ Tank 2 -11849 -PRM -DW CUPA - 23 CCR 16 2712(1); ® ❑ E] ❑ ❑ None HSC 6.7 25284 2010010 UST Operating Permit Application for Facility information and Tank information ® ❑ ❑ ❑ ❑ ❑ None submitted/maintained - 23 CCR 16 2711; HSC 6:7 25286(a) 2010001 Current BOE number submitted to the CUPA ® ❑ ❑ ❑ ❑ El None and/or CERS - HSC 6.7 25286(c) .2030011 UST compliance statement and/or Designated Operator ® ❑ ❑ ❑ ❑ ❑ None current certification submitted - 23 CCR 16 2715(a , 2715Lb) 2030046 A complete and accurate response plan has been submitted, approved and ® ❑ ❑ ❑ ❑ ❑ None maintained - 23 CCR 16 2632, 2634(e), 2641(h), 2712(i) 2030041 A complete and accurate plot plan has been submitted, approved and ® ❑ ❑ ❑ ❑ ❑ Minor maintained - 23 CCR 16 2632 d 1 C, 2711 a 8 2010006 Owner/Operator has not made false statements or representation on any ® ❑ ❑ ❑ ❑ ❑ None required document - HSC 6.7 25299 Violation Program Requirement v.;o SOC Comments NO 0U ". m 0.0 z O z D K 2010003 Owner/Operator has a DO and/or informed the CUPA of any change (s) ® ❑ ❑ ❑ ❑ ❑ None within 30 days - 23 CCR 16 2715(a) Testing 2030002 Owner/Operator has tested and certified leak ® ❑ TEJEI ❑ ❑ None detection equipment annual) - 23 CCR 16 2638 2030048 Secondary containment testing conducted every 36 months in accordance ® ❑ ❑ ❑ ❑ ❑ None with requirements - 23 CCR 16 2637 2030055 Spill buckets have been tested annually as ® ❑ ❑ ❑ ❑ ❑ None required - HSC 6.7 25284.2 2010009 Secondary containment test results submitted to the CUPA within 30 days ® ❑ ❑ ❑ ❑ ❑ None after the test - 23 CCR 16 2637 e 2030064 CU PA was poperly notified within the prescribed number of Z ❑ ❑ ❑ ❑ ❑ None hours prior to testing - 23 CCR 16 2637(0, 2638(e), 2643(g2,_2644 Ik a 4 Install/Repair 2060009 Permits obtained tp install,replace, repair, or ® ❑ Elff[I]El❑ENe modify part of the UST s stem - 23 CCR 16 2712 UST System Observation General Monitoring 2030003 Leak detection system maintains continuous RD monitoring that activates ® ❑ ❑ ❑ ❑ ❑ None ❑ an audible and visual Yes alarm - 23 CCR 16 2632, 2634, 2636r 2666 2030016 The annular space of the tank, piping and sumps RD are continuously ® El L1 E]❑ NoneEj monitored and activates Yes the alarm - 23 CCR 16 2631(g), 2632(c)(2)(A)&(B), 2633 c, 2636 2030017 Product piping outside the UDC is fail-safe and shuts down the pump or TZEI ❑ ❑❑ ❑ None restricts flow - 23 CCR 16 2636(0(5) Underground Storage Tank Program - DW Inspection Report v 2'8 Violation Program Requirement v ,`o_ SOC Comments No �J N �U H Q.m 2 m O Z O Z IC Off% 2030018 Turbine sump monitor RD activates an audible and visual alarm or stops the ® ❑ ❑ ❑ ❑ ❑ None ❑ flow of at the dispenser - Yes 23 CCR 16 2636 (1) 2030019 Monitoring. system in the UDCs activates an audible and visual alarm ® ❑ ❑ ❑ ❑ ❑ None or stops the flow at the UDC - 23 CCR 16 2636 (0(1) 2030043 Leakdetection equipment RD properly programmed or ® ❑ ❑ ❑ ❑ ❑ None ❑ properly operated - 23 CCR 16 2632, 2634, 2636, Yes 2666 2060005 System constructed with a monitoring system capable of detecting entry ® ❑ ❑ ❑ ❑ ❑ None into secondary containment - HSC 6.7 25291(b) 2060014 Correct leak detection equipment installed for RD the type of system ® ❑ ❑ ❑ ❑ ❑ None ❑ present - 23 CCR 16 2638; Yes HSC 6.7 25290.1, 25290.2, 25291 RD 2060015 Sensor located in the proper position/location- ® ❑ ❑ ❑ ❑ ❑ None ❑ 23 CCR 162630(d), 2641(a) Yes 2030062 Facility is in compliance RD with not tampering with or ® ❑ ❑ ❑ ❑ ❑ None ❑ disabling leak detection devices or alarms - HSC Yes 6.7 25299(3)(9 2060022 System constructed with a monitoring system capable ofdetecting entry ® ❑ ❑ ❑ ❑ ❑ None into secondary containment- HSC 6.7 25290.2(d) 2030034 Tag/sticker on affixed monitoring equipment ® ❑ ❑ ❑ ❑ ❑ None being certified, repaired, or replaced - 23 CCR 16 2638 VPH Monitoring VPH 2030065 Interstitialmonitoring of the annular spaces of the ❑ ❑ ® ❑ ❑ ❑ ]4Umaintained UST is properly -HSC 6.7 25290.1 e - Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement v o SOC Comments. No o0 mA Z O z M D a> 2060023 System constructed with a monitoring system capable of detecting entry into secondary ❑ ❑ ® ❑ ❑ ❑ None containment - HSC 6.7 25290,1(d) Line Leak Detector 2060012 Line leak detector installed on pressurized RD piping system - HSC 6.7 ❑ ❑ ® ❑ ❑ ❑ None ❑ 25290.1(h), 25290.2(8), Yes 25291(0, 25292(e), 2636 (0(2) 2030026 Line leak detectors detect a 3 gph leak and/or RD audible and Visual alarm ❑ ❑ ® ❑ ❑ ❑ None ❑ function properly - 23 Yes CCR 16 2636(1)(6), 2666(c) 2030027 Turbine shuts down when RD a leak is detected or is ❑ ❑ ® ❑ ❑ ❑ None ❑ when line leak detector disconnected - 23 CCR 16 Yes 2666 c 2030025 Pressurized piping able to detect 3.0 gph leak RD within an hour, and ❑ ❑ ® ❑ ❑ ❑ None ❑ restricts the Flow or Yes alarms - 23 CCR 16 2636 02(2) Secondary Containment 2060010 UST storing a hazardous RD substance has secondary ® ❑ ❑ ❑ ❑ ❑ None El HSC 6.7 Yes 25292 Underground Storage Tank Program - DW inspection Report ° 2.0 Violation Program Requirement ti;«. SOC Comments No z O o S� M Z 0 os 2030008 UDC, sumps, and/or other secondary containment In good ® ❑ ❑ ❑ ❑ ❑ None condition and/or are free of debris/liquid - HSC 6.7 25290.1, 25290.2, 25291 2030040 Secondarily contained RD piping maintained to allow ® ❑ E]❑ ❑ ❑ None [-]liquid to drain into sump - Yes 23 CCR 16 2630(d), 2641(a) 2060006 Secondary containment piping slopes back to the ® ❑ ❑ ❑ ❑ ❑ None collection sump -23 CCR 16 263(c) 2030047 Secondary containment maintained tight and has been confirmed by testing ® ❑ ❑ ❑ ❑ ❑ None - 23 CCR 16 2662, HSC 6.7 25290.1(c)(2), 25290.2(c)(2), 25291 (a), 25292 e 2030060 Entry fittings in secondary - containment for UST system maintained ® ❑ ❑ ❑ ❑ ❑ None tight/sealed - 23 CCR 16 2630, 2635(d), 2636(c), 2666 2060020 Spill bucket is installed RP and has a functional drain ® ❑ ❑ ❑ ❑ ❑ None ❑ valve or other means to remove liquid - 23 CCR 16 Yes 2635(b , 2665 2030054 Spill bucket maintained in RP good condition and free of ® ❑ ❑ ❑ ❑ ❑ None ❑ debris and/or liquid - 23 Yes (2) CCR 16 2635(b), 2715L(2) 2060019 Spill bucket to has a minimum capacity of five® ❑ ❑ DYE] None gallons - 23 CCR 16 2635(b), 2665 Overfill 2030035 UST system is operated RP to prevent unauthorized ® El El EJ❑ ❑ None release, including spills Yes and overfills - HSC 6.7 25292.1 a 2030036 Overfill prevention system RP has not been overridden ® ❑ ❑ ❑ ❑ ❑ None ❑ and meets overfill requirements - 23 CCR 16 Yes 2635(b)(2),2665 Underground Storage Tank Program -DW inspection Report v 2.0 Violation Program Requirement v o SOC Comments No O O a 2 O Q 2 o D U a x In On Site Records Certifications 2030023 Required designated operators or contractors maintain a proper and ® ❑ ❑ ❑ ❑ ❑ None current ICC certification - 23 CCR 16 2715 2030024 Service technician, installer, and/ or employee maintain a ® ❑ ❑ ❑ ❑ ❑ None proper license - 23 CCR 162715 2030031 Employee or contractor obtained and maintained proper manufacturer ® ❑ ❑ ❑ ❑ ❑ None certification - 23 CCR 16 2715 2010007 Submitlmaintain current Certificate of Financial Responsibility/mechanism of financial assurance - to ❑ ❑ ❑ ❑ None 23 CCR 16 2711; 23 CCR 18 2808.1, .2809-2809.2, HSC 6.7 25292.2; HSC 6.75 25299.30-25299.34 Designated Operator 2010004 Copies of DO inspections for last 12 months and list of trained employees ® ❑ ❑ ❑ ❑ ❑ None maintained -23 CCR 16 2715 2030013. Designated operator properly conducted the monthly inspection and ® ❑ ❑ ❑ ❑ ❑ None the reports are complete - 23 CCR 16.2715. 2030010 DO notified operator of any condition observed during the monthly ® ❑ ❑ ❑ ❑ ❑ None inspection that may require action - 23 CCR 16 2715(d) 2030012 DO employee training performed, current for at least one employee on ® ❑ ❑ ❑ ❑ ❑ None site, and a. log kept - 23 CCR 162715c 6,2715 Underground Storage Tank Program - DW Inspection Report v 2.0 Underground Storage Tank Program - DW Inspection Report v 2.0 Program Requirement vViolation SOC Comments Na O oO Z O .2 Logs 2030001 Leak detection alarm logs, maintenance and RD records of appropriate ® ❑ ❑ ❑ ❑ ❑ None ❑ follow-up actions Yes maintained - 23 CCR 16 2632, 2634, 2712(6 Maintenance/Tests 2010008 Monitoring, maintenance, repairs, linings, and RD upgrade records ® ❑ ❑ ❑ ❑ ❑ None ❑ maintained for the proper Yes time period - 23 CCR 46 2712(b) Documentation 2030033 Failure to maintain on site an approved monitoring ® ❑ ❑ ❑ ❑ ❑ None plan - 23 CCR 16 2632, 2634, 2711, 2712(i) 2030037 Written agreement between the tank owner and tank operator to monitor the tank system Z ❑ ❑ ❑ ❑ ❑ None is maintained - 23 CCR 16 2620(b); HSC 6.7 25284 a 3 2030061 Suspected or actual RD unauthorized release ❑ ❑ ® ❑ ❑ ❑ None ❑ reported in appropriate time frame - HSC 6.7 Yes 29294, 29295 General Operating Requirements Permit Condition/Approval 2030039 Compliance with all operating permit ® ❑ ❑ ❑ ❑ ❑ None conditions - 23 CCR 16 2712; HSC 6.7 25299 2030059 UST system maintained in accordance with exclusionlexemption ❑ ❑ ❑ ❑ ❑ ❑ None status - HSC 6.7 25261.6, 25283.5 2030014 Owner/Operator received approval and has implemented a training ❑ ❑ ® ❑ ❑ ❑ None program at an unstaffed facility -23 CCR 16 2715 2 2030015 Facility exhibited that the method used to monitor the tank meets the monitoring methods in Z ❑ ❑ ❑ ❑ ❑ None 2643(f) - 23 CCR 16 2643 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement d;o. SOC" Comments NO m F m z O z D O M 8> Red Tag 2030045 Red Tag information is legible and has not been ❑ ❑ ® ❑ ❑ ❑ None tampered with - 23 CCR 16 2717.1 2030044 Facility did not allow for deposit of petroleum into a UST that has a red tag ❑ ❑ ® ❑ ❑ ❑ None affixed to the fill - 23 CCR 16 2717.7 Install/Repair 2060024 UST system is made of or lined with materials that are compatible with the ® ❑ ❑ ❑ ❑ ❑ None substance stored - 23 CCR 16 26311 2060021 Striker plate installed and positioned correctly - 23 ® ❑ ❑ ❑ ❑ ❑ None CCR 16 2631 (C), 2662(d) ® There were no violations noted for this inspection. ❑This report shall serve as "NOTICE TO COMPLY" for Minor Violations, and a "NOTICE OF VIOLATION' for Major violations. You are, hereby, ordered to correct the above noted violations within 30 days, or according to correction summaries provided. Formal enforcement and/or penalty assessment may be initiated for any violations noted, and for those not corrected in a timely manner. (NOTE: If this is a preliminary report, a final report will follow.) Inspectors Signature: ✓ '<- Date:—/',,// 111ov ...,. ....... .. .. Check one box for facility Significant Operational Status (SOC) to be reported to SWRCB and US EPA: ❑ SOC with both Release Detection and Release Detection (Facility has no Release Prevention and no Release Prevention Violations) ❑ Not in SOC (Facility has both Release Prevention and Release Detection Violations) ❑SOC with Release Detection only (Facility has no Release Detection violations but one or more Release Prevention violations) ❑ SOC with Release Prevention only (Facility has no Release. Prevention violations but one or more Release Underground Storage Tank Program - DW inspection Report v 2.0