HomeMy WebLinkAboutCUPA REPORT 10.31.19Underground Storage Tank Program
DW Inspection _
Permission to Inspec
BAKERSFIELD FIRE DEPARTMENT
Prevention Services Division
2101 H Street
Bakersfield, CA 93301
Phone: 661 - 326 -3979
Fax: 661 -852 -2171
//R/
4101 fr
Business Name: PANAMA COLONY SHELL (15- 021 - 108586)
Date: 10131/2019 (EPA ID# CAL000403274)
Address Name: 2300 Panama Ln, Bakersfield, CA 93307
661 836 -3362
Inspector Name: Kris Kams ICC# 8292402
Inspection Type: Routine
Report : Final
NVO =No Violation Observed OUT= Out of Compliance NA =Not Applicable UD = Undetermined
COS = Corrected On Site RPT =Repeat Violation
Violation
Program Requirement
m 0
SOC
Comments
No
0
me
w
i
O
i
rc
os
File Review
Facility Tank Information
2030021
Facility has a valid Permit
Tank 1 - 10000- Reg- DW
to Operate from the
®
El
E]
El
El
El
None
Tank 2 - 5000 - Dies - DW
CUPA - 23 CCR 16 2712(i);
Tank 3 - 5000 - Sup - DW
HSC 6.7 25284
2010010
UST Operating Permit
Application for Facility
information and Tank
information
®
❑
❑
❑
❑
❑
None
submitted /maintained - 23
CCR 16 2711; HSC 6.7
25286(a)
2010001
Current BOE number
Board of Equalization Account is
submitted to the CUPA
❑
®
❑
❑
❑
❑
None
closed.
and /or CERS - HSC 6.7
25286(c)
2030011
UST compliance
statement and /or
Designated Operator
0
❑
❑
❑
❑
❑
None
current certification
submitted - 23 CCR 16
2715(a), 2715(6
2030046
A complete and accurate
response plan has been
submitted, approved and
®
❑
❑
❑
❑
❑
None
maintained - 23 CCR 16
2632, 2634(e), 2641(h),
2712 (1)
2030041
A complete and accurate
plot plan has been
submitted, approved and
®
❑
❑
❑
❑
❑
minor
maintained - 23 CCR 16
2632 d 1 C, 2711 a e
2010006
Owner /Operator has not
made false statements or
representation on any
®
❑
❑
❑
❑
❑
None
required document - HSC
6.7 25299
2010003
Owner /Operator has a
DO and /or informed the
CUPA of any change (s)
®
❑
❑
❑
❑
❑
None
within 30 days - 23 CCR
16 2715(a)
Violation
Program Requirement
v
SOC
Comments
No
O
N
r
S m
z
o
z
0
0U
o-
pj
Testing
2030002
Owner /Operator has
Violation written on 9/17/2019 and
tested and certified leak
❑
®
❑
❑
❑
❑
None
FMC completed late on 10- 31 -19.
detection equipment
annually - 23 CCR 16 2638
2030048
Secondary containment
SB -989 Testing was due on 12-9 -
testing conducted every
2018 and still has not been
36 months in accordance
❑
2
❑
❑
❑
❑
None
completed.
with requirements - 23
CCR 16 2637
2030055
Spill buckets have been
tested annually as
❑
❑
❑
❑
❑
❑
None
required - HSC6,725284.2
2010009
Secondary containment
test results submitted to
the CUPA within 30 days
®
❑
❑
❑
❑
❑
None
after the test - 23 CCR 16
2637 e
2030064
CUPA was poperly
notified within the
prescribed number of
®
❑
❑
❑
❑
❑
None
hours prior to testing - 23
CCR 16 2637(0, 2638(e),
2643(g), 2644.1(0)(4)
Install /Repair
2060009
Permits obtained to
install, replace, repair, or
®
❑
❑
❑
E]
E]
None
modify part of the UST
system - 23 CCR 16 2712
UST System Observation
General Monitoring
2030003
Leak detection system
maintains continuous
RD
monitoring that activates
®
11
El
El
0
E]
None
❑
an audible and visual
Yes
alarm - 23 CCR 16 2632,
2634, 2636, 2666
2030016
The annular space of the
tank, piping and sumps
are continuously
RD
monitored and activates
®
❑
❑
❑
❑
❑
None
❑
the alarm - 23 CCR 16
Yes
2631(g), 2632(c)(2)(A) &(B),
2633(c), 2636
2030017
Product piping outside the
UDC is fail -safe and shuts
down the pump or
®
❑
❑
❑
❑
❑
None
restricts flow - 23 CCR 16
2636( (5
2030018
Turbine sump monitor
activates an audible and
RD
visual alarm or stops the
®.
❑
❑
❑
❑
❑
None
❑
flow of at the dispenser -
Yes
23 CCR 16 2636(0(1)
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
d. o
SOC
Comments
No
m
z
O
z
D
UU
K
0'>
2030019
Monitoring system in the
UDCs activates an
audible and visual alarm
®
❑
❑
❑
❑
❑
None
or stops the flow at the
UDC - 23 CCR 16
2636 (0(1)
2030043
Leak detection equipment
Incon Monitoring System Printer is
properly programmed or
broken and not replaceable.
properly operated - 23
RD
Unable to obtain alarm history and
CCR 16 2632, 2634, 2636,
L1
®
❑
❑
❑
❑
None
❑
system set up. Monitoring system
2666
Yes
will be required to either be
repaired or upgraded within 30
days by 12 -15 -2019.
2060005
System constructed with
a monitoring system
capable of detecting entry
®
❑
❑
❑
❑
❑
None
into secondary
containment - HSC 6.7
25291(b)
2060014
Correct leak detection
equipment installed for
RD
the type of system
®
❑
❑
❑
❑
❑
None
❑
present - 23 CCR 16 2638,
Yes
HSC 6.725290.1, 25290.2,
25291
2060015
Sensor located in the
RD
proper position /location -
®
❑
❑
❑
❑
❑
None
❑
23 CCR 16 2630(d), 2641(a)
Yes
2030062
Facility is in compliance
with not tampering with or
TOE
RD
disabling leak detection
®
❑
❑
❑
None
❑
devices or alarms - HSC
Yes
6.725299(a)(9)
2060022
System constructed with
a monitoring system
capable of detecting entry
®
❑
❑
❑
❑
❑
None
into secondary
containment - HSC 6.7
25290.2(d)
2030034
Tag /sticker on affixed
monitoring equipment
being certified, repaired,
z
❑
❑
❑
❑
❑
None
or replaced - 23 CCR 16
2638
VPH Monitoring VPH
2030065
Interstitial monitoring of
the annular spaces of.. _
RD
UST is properly
❑
❑
®
❑
❑
❑
None
❑
maintained - HSC 6.7
Yes
25290.1 e
Underground Storage Tank Program - DW Inspection Report v2.0
Violation
Program Requirement
v o
SOC
Comments
No
a
z
o z
O0
W
M
2060023
System constructed with
a monitoring system
capable of detecting entry
into secondary
❑
❑
®
❑
❑
❑
None
containment - HSC 6.7
25290.1(d)
j
Line Leak
Detector
2060012
Line leak detector
'..
installed on pressurized
RD
piping system - HSC 6.7
®
❑
❑
El
El
E]
None
El
25290,1(h), 25290.2(9),
Yes
25291(0, 25292(e),
2636 2)
2030026
Line leak detectors detect
a 3 gph leak and /or
RD
audible and visual alarm
®
❑
❑
❑
E]
❑
None
El
function properly - 23
Yes
CCR 16 2636(0(6),
2666(c)
2030027
Turbine shuts down when
a leak is detected or
RD
when line leak detector is
❑
❑
®
❑
❑
❑
None
❑
disconnected - 23 CCR 16
Yes
2666(c)
2030025
Pressurized piping able to
detect a 3.0 gph leak
RD
within an hour, and
®
❑
❑
❑
❑
❑
None
❑
restricts the flow or
Yes
alarms - 23 CCR. 16
2636 f 2
Secondary Containment
2060010.
UST storing a hazardous
RD
substance has secondary
®
❑
❑
❑
❑
❑
None
❑
containment - HSC 6.7
Yes
25292
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
v _
SOC
Comments
No
mg
z
o z
U
M
K
j
2030008
UDC, sumps, and /or
other secondary
containment in good
®
❑
❑
❑
❑
❑
None
condition and /or are free
of debris /liquid - HSC 6.7
25290.1, 25290.2, 25291
2030040
Secondarily contained
RD
piping maintained to allow
®
E]
E]
E]
E]
E]
None
El
liquid to drain into sump -
Yes
23 CCR 16 2630 d , 2641 a)
2060006
Secondary containment
piping slopes back to the
®
❑
❑
❑
❑
❑
None
collection sump- 23 CCR
16 263(c)
2030047
Secondary containment
maintained tight and has
been confirmed by testing
®
❑
❑
❑
❑
❑
None''
- 23 CCR 16 2662, HSC 6.7
25290. 1(c)(2), 25290.2(0)(2),
25291 a, 25292 e
2030060
Entry fittings in secondary
containment for UST
system maintained
®
❑
El
El
El
F-1
None
tight/sealed - 23 CCR 16
.2630, 2635(d), 2636(0), .
2666
2060020
Spill bucket is installed
Violation written on 9112/2019 and
and has a functional drain
RP
FMC completed late on 10- 31 -19.
valve or other means to
❑
®
❑
❑
❑
❑
None
❑
remove liquid - 23 CCR 16
Yes
2635(6), 2665
2030054
Spill bucket maintained in
RP
good condition and free of
®
TL
F1
0
El
None
El
debris and /or liquid - 23
Yes
CCR 16 2635(6), 2715(c)(2)
2060019
Spill bucket to has a
minimum capacity of five
®
❑
❑
❑
❑
❑
None
gallons - 23 CCR 16
2635(b), 2665
Overfill
2030035
UST system is operated
to prevent unauthorized
RP
release, including spills
®
❑
❑.
❑
❑
❑
None
❑
and overfills - HSC 6.7
Yes
25292.1(a)
2030036
Overfill prevention system
Facility still has not completed
has not been overridden
RP
Overfill Prevention Inspection.
and meets overfill
❑
®
❑
❑
❑
❑
None
❑
requirements - 23 CCR 16
Yes
2635(b)(2). 2665
Underground Storage Tank Program - D W Inspection Report v 2.0
Violation
Program Requirement
v;o
SOC
Comments
No
a
o
z
M
o. j.
On Site
Records
Certifications
2030023
Required designated
.
operators or contractors
maintain proper and
®
❑
❑
❑
❑
❑
None
current ICC certification -
23 CCR 16 2715
2030024
Service technician,
installer, and/or
employee maintain a
0
❑
❑
❑
❑
❑
None
proper license - 23 CCR
162715
2030031
Employee or contractor
obtained and maintained
proper manufacturer
®
❑
❑
❑
❑
❑
None
certification - 23 CCR 16
2715
2010007
Submit/maintain current
Certificate of Financial
Responsibility /mechanism
of financial assurance -
®
❑
❑
❑
❑
❑
None
23 CCR 16 2711;.23 CCR
18 2808.1, 2809 - 2809.2;
HSC 6.7 25292.2; HSC
6.75 25299.30- 25299.34
Designated Operator
2010004
Copies of DO inspections
for last 12 months and list
of trained employees
®
❑
❑
❑
1:1
❑
None
maintained - 23 CCR 16
2715
2030013
Designated operator
properly conducted the
monthly inspection and
®
❑
❑
❑
❑
❑
None
the reports are complete -
23 CCR 16 2715
2030010
DO notified operator of
any condition observed
during the monthly
®
❑
❑
❑
❑
❑
None
inspection that may
require action - 23 CCR 16
2715 tl
2030012
DO employee training
performed, current for at
least one employee on
®
❑
❑
❑
❑
❑
None
site, and a log kept - 23
CCR 162715(c )(6), 2715
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
wl o.
SOC
Comments
No
0U
v
2
00
Z
D
K
Logs
2030001
Leak detection alarm
logs, maintenance and
RD
records of appropriate
®
El
El
❑
El
[]
None
❑
follow -up actions
Yes
maintained - 23 CCR 16
2632, 2634, 2712(b)
Maintenance /Tests
2010008
Monitoring, maintenance,
repairs, linings, and
RD
upgrade records
®
❑
❑
❑
❑
❑
None
El
maintained for the proper
Yes
time period - 23 CCR 16
2712(b)
Documentation
2030033
Failure to maintain on site
an approved. monitoring
Z
❑
❑
❑
❑
❑
None
plan - 23 CCR 16 2632,
2634, 2711, 2712(1)
2030037
Written agreement
between the tank owner
and tank operator to
monitor the tank system
®
❑
❑
❑
❑
❑
None
is maintained - 23 CCR 16
2620(6); HSC 6.7
25284 a (3
2030061
Suspected or actual
unauthorized release
RD
reported in appropriate
ILL]
®
El
El
❑
None
❑
time frame - HSC 6.7
Yes
29294, 29295
General Operatin g. Requirements
Permit Condition /Approval
2030039
Compliance with all
Correct all open violations by
operating permit
❑
®
❑
❑
❑
❑
None
12-2-2019 or UST's will be red
conditions - 23 CCR 16
lagged until in compliance.
2712, HSC 6.7 25299
2030059
UST system maintained
in accordance with
exclusionlexemption
®
❑
❑
❑
❑
❑
None
status - HSC 6.7 25281.6,
25283.5
2030014
OwnerlOperator received
approval and has
implemented a training
❑
❑
®
❑
❑
❑
None
program at an unstaffed
facility - 23 CCR 16
2715 (2)
2030015
Facility exhibited that the
method used to monitor
the tank meets the
monitoring methods in
®
❑
❑
❑
❑
❑
None
2643(f) -. 23 CCR 162643
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
° `o
SOC
Comments
NO
z
O
z
0
0
rc
°
oS'
Red Tag
2030045
Red Tag information is
legible and has not been
❑
❑
®
❑
❑
❑
None
tampered with - 23 CCR
162717.1
2030044
Facility did not allow for
deposit of petroleum into
a UST that has a red tag
❑
❑
®
❑
❑
❑
None
affixed to the fill - 23 CCR
162717.1
Install/Repair
2060024
UST system is made of or
lined with materials that
are compatible with the
M
❑
❑
❑
❑
❑
None
substance stored - 23
CCR 162631.1
2060021
Striker plate installed and
positioned correctly - 23
❑
❑
❑
®
❑
❑
None
CCR 16 2631 c , 2662 tl
❑ There were no violations noted for this inspection.
®This report shall serve as a "NOTICE TO COMPLY" for Minor Violations, and a "NOTICE OF VIOLATION' for
Major violations. You are, hereby, ordered to correct the above noted violations within 30 days, or according to
correction summaries provided. Formal enforcement and /or penalty assessment may be initiated for any
violations noted, and for those not corrected in a timely manner. (NOTE: If this is a preliminary report, a final report
will follow.)
Inspectors Signature:
,t1./h Date: /O�?!/r
Check one box for facility Significant Operational Status (SOC) to be reported to SWRCB and US EPA:
❑ SOC with both Release Detection and Release Detection (Facility has no Release Prevention and no Release
Prevention Violations)
❑ Not in SOC (Facility has both Release Prevention and Release Detection Violations)
❑SOC with Release Detection only (Facility has no Release Detection violations but one or more Release Prevention
violations)
❑ SOC with Release Prevention only (Facility has no Release Prevention violations but one or more Release Detection
Underground Storage Tank Program - D W Inspection Report v 2.0