Loading...
HomeMy WebLinkAboutCUPA REPORT 10.23.19Underground Storage Tank Program DW Inspection Rep ort��f Permission to Inspeck BAKERSFIELD FIRE DEPARTMENT Prevention Services Division 2101 H Street Bakersfield, CA 93301 Phone: 661 - 326 -3979 Fas: 661 -852 -2171 A_ /TI T Business Name: 7- ELEVEN INC. #22150 (15 -021- 103443) Date: 10 -23 -2019 (EPA ID: CAL000447594) Address Name: 4012 White Ln, Bakersfield, CA 93309, (661) 834 -8565 Inspector Name: Kris Karns ICC# 8292402 Inspection Type: Routine Report: Final NVO =No Violation Observed OUT= Out of Compliance NA =Not Applicable UD = Undetermined COS = Corrected On Site RPT = Repeat Violation Violation Program Requirement d ,`o SOC Comments No 0 2.2 wO z O z , rc gs File Review Facility Tank Information 2030021 Facility has a valid Permit Tank 1 - 12000- Reg - DW to Operate from the ® ❑ El El El El None Tank 2 - 8000 - Sup - DW CUPA - 23 CCR 16 2712(1); Tank 3 - 12000 - Dies - DW HSC 6.7 25284 2010010 UST Operating Permit Application for Facility information and Tank information ® ❑ ❑ ❑ ❑ ❑ None submitted /maintained - 23 CCR 16 2711; HSC 6.7 25286(a) 2010001 Current BOE number submitted to the CUPA ® ❑ ❑ ❑ ❑ ❑ None and /or CERS - HSC 6.7 25286 c 2030011 UST compliance statement and /or Designated Operator ® ❑ ❑ ❑ ❑ ❑ None current certification submitted - 23 CCR 16 2715(a), 2715(b) 2030046 A complete and accurate response plan has been submitted, approved and ® ❑ ❑ ❑ ❑ ❑ None maintained - 23 CCR 16 2632, 2634(e), 2641(h), 27121 2030041 A complete and accurate plot plan has been submitted, approved and ® ❑ ❑ ❑ ❑ ❑ I Minor maintained - 23 CCR 16 2632 d 1 C, 2711 a 8 2010006 Owner /Operator has not made false statements or representation on any ® ❑ ❑ ❑ ❑ ❑ None required document - HSC 6.725299 2010003 Owner /Operator has a DO and /or informed the CUPA of any change (s) g ❑ ❑ ❑ ❑ ❑ None within 30 days - 23 CCR 152715(a) Testing Violation Program Requirement m o SOC Comments No A z O z M O 0 O o f 2030002 Owner /Operator has tested and certified leak ® ❑ ❑ ❑ ❑ ❑ None detection equipment annual) - 23 CCR 16 2638 2030048 Secondary containment testing conducted every 36 months in accordance ® ❑ ❑ ❑ ❑ ❑ None with requirements - 23 CCR 16 2637 2030055 Spill buckets have been tested annually as ® ❑ ❑ ❑ ❑ ❑ None required - HSC 6.7 25284.2 2010009 Secondary containment test results submitted to the CU PA within 30 days ® ❑ ❑ ❑ ❑ ❑ None after the test - 23 CCR 16 2637 e 2030064 CUPA was poperly notified within the prescribed number of ® ❑ ❑ ❑ ❑ ❑ None hours prior to testing - 23 CCR 162637(1), 2638(e), 2643(g), 2644,1(a)(4) Install /Repair 2060009 Permits obtained to install, replace, repair, or ® ❑ ❑ ❑ ❑ ❑ None modify part of the UST system - 23 CCR 16 2712 UST System Observation General Monitoring 2030003 Leak detection system maintains continuous RD monitoring that activates ® ❑ ❑ ❑ ❑ ❑ Nan. ❑ an audible and visual Yes alarm - 23 CCR 16 2632, 2634, 2636, 2666 2030016 The annular space of the tank, piping and sumps RD are continuously monitored and activates ® ❑ ❑ ❑ ❑ ❑ None ❑ the alarm - 23 CCR 16 Yes 2631(9), 2632(c)(2)(A)8(8), 2633(c), 2636ffl 2030017 Product piping outside the UDC is fail -safe and shuts down the pump or ® ❑ ❑ ❑ ❑ ❑ None restricts flow - 23 CCR 16 2636(1)(5 .2030018 Turbine sump monitor RD activates an audible and visual alarm or stops the ® ❑ ❑ ❑ ❑ E] None El flow of at the dispenser - Yes 23 CCR 16 2636 (Di1) Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement w,`o_ BOC Comments NO m z O z 0V M X Q7 2030019 Monitoring system in the UDCs activates an audible and visual alarm H ❑ ❑ ❑ ❑ ❑ None or stops the flow at the UDC - 23 CCR 16 2636 (0(12 2030043 Leak detection equipment RD properly programmed or properly operated - 23 H ❑ ❑ ❑ ❑ ❑ None ❑ CCR 162632, 2634, 2636, Yes 2666 2060005 System constructed with a monitoring system capable of detecting entry TZLI ❑ ❑ ❑ El into secondary containment - HSC 5.7 25291(b) 2060014 Correct leak detection equipment installed for RD the type of system H L1 1-1 El El El None E:1 present - 23 GCR 16 2638, Yes HSC 6.7 25290.1, 25290.2, 25291 2060015 Sensor located in the RD proper position /location - ® ❑ ❑ ❑ ❑ E] None ❑ 23 CCR 16 2630(d), 2641(a) Yes 2030062 Facility is in compliance with not tampering with or RD disabling leak detection ❑ ❑ ❑ ❑ ❑ None ❑ devices or alarms - HSC Yes 6.725299(a )(9 2060022 System constructed with a monitoring system capable of detecting entry H ❑ ❑ ❑ ❑ ❑ None into secondary containment - HSC 67 252902(d) 2030034 Tag /sticker on affixed monitoring equipment being certified, repaired, ® ❑ ❑ ❑ rONon. or replaced - 23 CCR 16 2638( VPH Monitoring VPH 2030065 Interstitial monitoring of the annular spaces of the RD UST is properly H ❑ ❑ ❑ ❑ T[:]Non. ❑ maintained - HSC 6.7 Yes 25290.1 . 2060023 System constructed with a monitoring system capable of detecting entry into secondary H ❑ ❑ ❑ ❑ JEIN.n. containment - HSC 6.7 25290.1(d) Underground Storage Tank Program - D W Inspection Report v 2.0 Violation Program Requirement v o SOC Comments No o i— w 0U _ 2'. m Z o Z M ce 0 j Line Leak Detector 2060012 Line leak detector installed on pressurized RD piping system - HSC 6.7 ® ❑ ❑ ❑ ❑ ❑ None ❑ 25290.1(h), 25290.2(g), Yes 25291(Q, 25292(e), 2636(0(2) 2030026 Line leak detectors detect a 3 gph leak and /or RD audible and visual alarm ® ❑ ❑ ❑ ❑ ❑ None ❑ function properly - 23 Yes CCR. 16 2636(0(6), 2666(c) 2030027 Turbine shuts down when a leak . is detected or RD when line leak detector is ❑ ❑ ® ❑ ❑ ❑ None ❑ disconnected - 23 CCR 16 Yes 2666(c) 2030025 Pressurized piping able to detect a 3.0 gph leak RD within an hour, and ® ❑ ❑ ❑ ❑ ❑ None ❑ restricts the flow or Yes alarms - 23 CCR 16 2636( (2) Secondary Containment 2060010 UST storing a hazardous RD substance has secondary ® ❑ ❑ ❑ ❑ ❑ None ❑ E: containment - HSC 6.7 Yes 25292 Underground Storage Tank Program - DW Inspection Report v 2.0 Violation Program Requirement v.;o S 0 Comments No o. u, 2! " Z 00 2 M 00 K �.2 2030008 UDC, sumps, and /or other secondary containment in good ® ❑ ❑ ❑ ❑ ❑ None condition and /or are free of debris /liquid - HSC 6.7 25290.1, 25290.2, 25291 2030040 Secondarily contained RD piping maintained to allow E ❑ ❑ ❑ ❑ ❑ None ❑ liquid to drain into sump - Yes 23 CCR 16 2630(d), 2641(a) 2060006 Secondary containment piping slopes back to the E ❑ ❑ ❑ ❑ ❑ None collection sump - 23 CCR 16 263 c 2030047 Secondary containment maintained tight and has been confirmed by testing E ❑ ❑ ❑ ❑ ❑ None - 23 CCR 162662, HSC 6.7 25290.1(c)(2), 25290.2(c)(2), 25291 a , 25292(e) 2030060 Entry fittings in secondary containment for UST system maintained E ❑ ❑ ❑ [E] ❑ None tight/sealed - 23 CCR 16 2630, 2635(d), 2636(c), 2666 2060020 Spill bucket is installed and has a functional drain RP valve or other means to E ❑ ❑ ❑ ❑ ❑ None ❑ remove liquid - 23 CCR 16 Yes 2635 b), 2665 2030054 Spill bucket maintained in RP good condition and free of E ❑ ❑ ❑ ❑ ❑ None ❑ debris and /or liquid - 23 Yes CCR 16 2635(b), 2715(c )(2 2060019 Spill bucket to has a minimum capacity of five E ❑ ❑ ❑ ❑ ❑ None gallons - 23 CCR 16 2635(b), 2665 Overfill 2030035 UST system is operated to prevent unauthorized RP release, including spills E ❑ ❑ ❑ ❑ ❑ None ❑ and overfills - HSC 6.7 Yes 25292.1 (a) 2030036 Overfill prevention system RP has not been overridden and meets overfill E ❑ ❑ ❑ ❑ ❑ None ❑ requirements - 23 CCR 16 Yes 2635(b)(2),2665 Underground Storage Tank program - D W Inspection Report v 2.0 Violation Program Requirement y. o. SOC Comments No m z o z rc o> On Site Records Certifications 2030023 Required designated operators or contractors maintain a proper and ® ❑ ❑ ❑ ❑ ❑ None current ICC certification - 23 CCR 16 2715 2030024 Service technician, installer, and/ or employee maintain a ® ❑ ❑ ❑ ❑ ❑ None proper license - 23 CCR 162715 2030031 Employee or contractor obtained and maintained proper manufacturer ® ❑ ❑ ❑ ❑ ❑ None certification - 23 CCR 16 2715 2010007 Submit/maintain current Certificate of Financial Responsibility/mechanism of financial assurance - ® ❑ ❑ ❑ ❑ ❑ None 23 CCR 16 2711; 23 CCR 18 2808.1, 2809 - 2809.2; HSC 6.7 25292.2; HSC 6.75 25299.30- 25299.34 Designated Operator 2010004 Copies of DO inspections for last 12 months and list of trained employees ® ❑ ❑ ❑ ❑ ❑ None maintained - 23 CCR 16 2715 2030013 Designated operator properly conducted the monthly inspection and ® ❑ ❑ ❑ ❑ ❑ None the reports are complete - 23 CCR 16 2715 2030010 DO notified operator of any condition observed during the monthly M ❑ ❑ ❑ ❑ ❑ None inspection that may require action - 23 CCR 16 2715 tl 2030012 DO employee training performed, current for at least one employee on E ❑ ❑ El El ❑ None site, and a log kept- 23 CCR 16 2715(c)(6), 2715 Underground Storage Tank Program - DW Inspection Report ° 2.0 Violation Program Requirement ,°`o_ SOC Comments No ca 0 m z O Z K Oj Logs 2030001 Leak detection alarm logs, maintenance and RD records of appropriate ® ❑ ❑ ❑ ❑ ❑ None ❑ follow -up actions Yes maintained - 23 CCR 16 2632, 2634, 2712(b) Maintenance/Tests 2010008 Monitoring, maintenance, repairs, linings, and RD upgrade records ® ❑ ❑ ❑ ❑ ❑ None ❑ maintained forthe. proper Yes time period - 23 CCR 16 2712 6 Documentation 2030033 Failure to maintain on-site an approved monitoring ® ❑ ❑ ❑ ❑ ❑ None plan - 23 CCR 16 2632, 2634, 2711, 2712(1) 2030037 Written agreement between the tank owner and tank operator to monitor the tank system ® ❑ ❑ ❑ ❑ ❑ None is maintained - 23 CCR 16 2620(4); HSC 6:7 25284(a )(3 2030061 Suspected or actual RD unauthorized release reported in appropriate ❑ ❑ ® ❑ ❑ ❑ None ❑ time frame - HSC 6.7 Yes 29294, 29295 General Operating Requirements Permit Condition /Approval 2030039 Compliance with all operating permit ® ❑ ❑ ❑ ❑ ❑ None conditions - 23 CCR 16 2712; HSC 6.725299 2030059 UST system maintained in accordance with exclusion /exemption ® ❑ ❑ ❑ ❑ ❑ None status - HSC 6.7 25281.6, 25283.5 2030014 Owner /Operator received approval and has implemented atraining ❑ ❑ ® ❑ ❑ ❑ None program at an unstaffed facility - 23 CCR 16 2715 (f)(2) 2030015 Facility exhibited that the method used to monitor the tank meets the monitoring methods in ® ❑ ❑ ❑ ❑ ❑ None 2643(f) - 23 CCR 16 2643 Underground Storage Tank Program - D W Inspection Report v 2.0 Violation Program Requirement d SOC Comments No M i O i M a rc p> Red Tag 2030045 Red Tag information is legible and has not been ❑ ❑ ® ❑ ❑ ❑ None tampered with - 23 CCR 162717.1 2030044 Facility did not allow for deposit of petroleum into a UST that has a red tag ❑ ❑ ® ❑ ❑ ❑ None affixed to the fill - 23 CCR 16 2717.1 Install /Repair 2060024 UST system is made of or lined with materials that are compatible with the ® ❑ ❑ ❑ ❑ ❑ None substance stored - 23 CCR 16 2631.1 2060021 Striker plate installed and positioned Correctly - 23 ❑ ❑ ❑ ® ❑ ❑ None CCR 16 2631(c), 2662(d) ® There were no violations noted for this inspection. [-]This report shall serve as a "NOTICE TO COMPLY" for Minor Violations, and a "NOTICE OF VIOLATION' for Major violations. You are, hereby, ordered to correct the above noted violations within 30 days, or according to correction summaries provided. Formal enforcement and/or penalty assessment may be initiated for any violations noted, and for those not corrected in a timely manner. (NOTE: If this is a preliminary report, a final report will follow.) Inspectors Signature: iU P !at Z< � Date: /r; /7 ..arm.....,. �...... ..-- - ._._- ._.._..- _._. -.. Check one box for facility Significant Operational Status (SOC) to be reported to SWRCB and US EPA: ❑ SOC with both Release Detection and Release Detection (Facility has no Release Prevention and no Release Prevention Violations) ❑ Not in SOC (Facility has both Release Prevention and Release Detection Violations) ❑SOC with Release Detection only (Facility has no Release Detection violations but one or more Release Prevention violations) ❑ SOC with Release Prevention only (Facility has no Release Prevention violations but one or more Release Detection Underground Storage Tank Program - D W Inspection Report v 2.0