Loading...
HomeMy WebLinkAboutFire SafetyFIRE PREVENTION INSPECTION j `�ii �% BAKERSFIELD FIRE DEPARTMENT Prevention Services 2101 H Street !�`,. Bakersfield, CA 93301 Phone: 661-326-3979 • Fax: 661-652-2171 1AC6ITYROOREass DATE/ `/ IG 14 O O PAQLTrY NAME .r M, BTATB, SR BUSINESS OWNERS NAM AND ADDRESS ENNEN'SNANE PN EO. BI0. TO, Ds DIFNNENT FROM AI .) NAM4ADDRE55 CITY, IAI, S[N PX XO. Occ TVPe Lo Av No. LOURS See USE ROGER DATE L I wn/D.y aPrmwx eF.Em Trp•=r Al..m a,..}m CONSTRUCTION TYPE USE .1. Sa/Fr of BLD ❑ VES ❑ NO N / Co4RECiALL rrounoxs v REOUIRenexTS CMCKED BE. NN1 Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises (CFC cml LEGO. WARTS/Mir 304.1.1) vSOeTAWON Provide non-combustible containers with tight fitting lids for the storage of combustible waste and 2 rubbish pending its safe disposal. (CFC 304,3.2) Note: applies to containers over 40 gallons. to at least 3 feet clearance around motor fuse box/fire door (CFC wnausrnls FMASE Relocate combustible storage provide \3 605.3) Relocate fire extinguisher(s) SO that they Will be In a conspicuous location, hanging on bracketswith the 4 top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9) EmrwtivxERs 5 Provide and Install (amount) _ _ approved (type IS size) portable fire extinguisher to be Immediately accessible for use in (area) _—___ _ (CFC TABLE 906.3) Re -charge all fire extinguishers. Fire extinguishers Shall be serviced at least once each year, and/or 6 after each use, by a person having s valid license or Certificate. (CFC 906.2) Provide and maintain -EXIT" sights) with letters 6 or more Inches In height over each required exit SISxB T (door/window) to fire escape. (CFC 1011) Provide and maintain appropriate numbers on a contrasting background antl visible from the street to e indicate the correct address of the building, (CFC 505.1) Repair all (cracks/holes/openings) in plaster In (location) fin's RAYTmna B Plastering Shall return the surface to its original fire resistive condition. (CFC 703.1) So ------- Remove/repair (Item & location) -------------- — ------------ -- Self-closing doors shall be designed to close by gravity, or by the action of a mechanical device, or by an Sstf-clos[ng approved smoke and heat sensitive device. Self-closing doors shall have no attachments Capable of preventing the operation of the closing device. (CFC 703.2) 11 Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1031.1) vRs 12 Provide a cont rastlng colored and permanently Installed electric lover or near required exit (location) -- to clearly Indicate It I[ as an exit. (CFC 1008) - ___ _................. Remove all storage and/or other obstructions from fire escape landings and stairways Stair shafts. (Fire BtoRANE 13 escapes/stair shafts are to be maintained free from obstructions at all times.) (CFC 1003.6) Extension cords shall not be used in lieu of permanent approved wiring. Install adtlltlonal approved BLECTRIGL APPLIANCES 14 electrical outlets where needed. (CFC 605.5) Convenience outlet (one plug per outlet) (CFC 35 Remove multiple attachment cords from specific electrical 605.4) ovroocR NURxnae 16 R re doral fire o o n burelre. (CFC 307.1) eeRlpORES 17 Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.). OTHER 191 T" , iooD HJ. A- rJ o -., Cr T Correct the violations noted above by: 7 C CORRECTION GATE - LEGEND: C.F.C. CALIFORNIA FIRE CODE C.B.C. CALIFORNIA BUILDING CODE CUSTOMER: 1M (SlgnaNre) (Please Pnnt Name Legy, Tlde)r B.M.C. BAKERSFIELD MUNICIPAL CODE P -G N.F.P.A. NATIONAL FIRE PROTECTION � 1— INSPECTOR: OnINO.: ASSOCIATION N.E.C. NATIONAL ELECTRIC CODE White - Prevention Services yellow - Station Copy Pink - Business Copy FD Nix fRrv. DLZ0341