Loading...
HomeMy WebLinkAbout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ame as Facility Name or DBA-Doing Business As) %XVLQHVV6LWH$GGUHVV &LW\ =,3&RGH ,, 81'(5*5281'6725$*(7$1.6(59,&(7(&+1,&,$1,1)250$7,21 1DPHRI&RPSDQ\3HUIRUPLQJWKH&HUWLILFDWLRQ 3KRQH 0DLOLQJ$GGUHVV 1DPHRI8676HUYLFH7HFKQLFLDQ3HUIRUPLQJWKH&HUWLILFDWLRQ(Print as shown on the ICC Certification) &RQWUDFWRU7DQN7HVWHU/LFHQVH ,&&&HUWLILFDWLRQ ,&&&HUWLILFDWLRQ([SLUDWLRQ'DWH 0RQLWRULQJ6\VWHP7UDLQLQJDQG&HUWLILFDWLRQV(List all applicable certifications.) ([SLUDWLRQ'DWH ,,, 5(68/762)7(67,1*6(59,&,1* Indicate and attach the following reports if the monitoring equipment is capable of generating either.<11$0RQLWRULQJ6\VWHP6HWXS$ODUP+LVWRU\5HSRUW :DVDQ\PRQLWRULQJHTXLSPHQWUHSODFHG" (If “Yes,” identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) :DVGDPDJHGHEULVRUOLTXLGIRXQGLQVLGHDQ\VHFRQGDU\FRQWDLQPHQWV\VWHPV" (If “Yes,” describe what was found in section IV below.) ,VDOOPRQLWRULQJHTXLSPHQWRSHUDWLRQDOSHUPDQXIDFWXUHU¶VVSHFLILFDWLRQV" (If “No,” describe why in section IV below.) ,9 &200(176 If directed to use this section, describe how and when the issues were or will be corrected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xpress Gas 928 Flower Street Bakersfield 93305 16250 Meacham Road, Bakersfield, CA 93314 Aaron Perrigo 804904 8485827 9/14/2020 Veeder Root B47853 8/3/2020 Changed 420 sensor in Annular space. Confidence UST Services, Inc. (800) 339-9930 ,' ,GHQWLILFDWLRQ6: 6LQJOH:DOOHG93+ 9DFXXP3UHVVXUH+\GURVWDWLF//' /LQH/HDN'HWHFWRU 81 ZZZXQLGRFVRUJ 5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  9, ,19(1725<2)(48,30(17&(57,),(' A separate Monitoring System Certification Form must be prepared for each monitoring system control panel. 0DNHRI0RQLWRULQJ6\VWHP&RQWURO3DQHO  0RGHORI0RQLWRULQJ6\VWHP&RQWURO3DQHO  6RIWZDUH9HUVLRQ,QVWDOOHG  Check the appropriate boxes to indicate specific equipment inspected/serviced. 0RQLWRULQJ'HYLFH8VHG'HYLFH0RGHO0RQLWRULQJ'HYLFH8VHG'HYLFH0RGHO 7$1.,' (By tank number, stored product, etc.) 7$1.,' (By tank number, stored product, etc.) ,Q7DQN*DXJLQJ(SW Tank),Q7DQN*DXJLQJ(SW Tank) $QQXODU6SDFHRU9DXOW6HQVRU$QQXODU6SDFHRU9DXOW6HQVRU 93+6HQVRU93+6HQVRU 3URGXFW3LSLQJ3URGXFW3LSLQJ 0HFKDQLFDO//'0HFKDQLFDO//' (OHFWURQLF//'(OHFWURQLF//' 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  )LOO3LSLQJ)LOO3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9HQW3LSLQJ9HQW3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9DSRU5HFRYHU\3LSLQJ9DSRU5HFRYHU\3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  0RQLWRULQJ'HYLFH8VHG 'HYLFH0RGHO0RQLWRULQJ'HYLFH8VHG 'HYLFH0RGHO 7$1.,' (By tank number, stored product, etc.) 7$1.,' (By tank number, stored product, etc.) ,Q7DQN*DXJLQJ(SW Tank),Q7DQN*DXJLQJ(SW Tank) $QQXODU6SDFHRU9DXOW6HQVRU$QQXODU6SDFHRU9DXOW6HQVRU 93+6HQVRU93+6HQVRU 3URGXFW3LSLQJ3URGXFW3LSLQJ 0HFKDQLFDO//'0HFKDQLFDO//' (OHFWURQLF//'(OHFWURQLF//' 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  )LOO3LSLQJ)LOO3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9HQW3LSLQJ9HQW3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9DSRU5HFRYHU\3LSLQJ9DSRU5HFRYHU\3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  Veeder Root TLS-0320 323.03 T1 Unl 847390-107 794390-420 FX1V 794380-208 794380-208 T2 Prem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pecify in section VII.)2WKHU(Specify in section VII.) 2WKHU0RQLWRUHG&RPSRQHQW,'2WKHU0RQLWRUHG&RPSRQHQW,' 2WKHU(Specify in section VII.)2WKHU(Specify in section VII.) 2WKHU0RQLWRUHG&RPSRQHQW,'2WKHU0RQLWRUHG&RPSRQHQW,' 2WKHU(Specify in section VII.)2WKHU(Specify in section VII.) Include information for every underground storage tank component monitored by this monitoring system control panel. If the monitoring system control panel monitors more components than this form accommodates, additional copies of these pages may be attached. 9,, &200(176 Use this section to provide additional comments about the inventory of the equipment certified.  1-2 794380-208 3-4 794380-208 5-6 794380-208 7-8 794380-208 9-10 794380-208 11-12 794380-208 < <HV1 1R1$ 1RW$SSOLFDEOH 81 ZZZXQLGRFVRUJ 5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  9,,, 021,725,1*6<67(0$1'352*5$00,1* This section must be completed if a monitoring panel is used to perform leak detection monitoring.<11$ $UHWKHYLVXDODQGDXGLEOHDODUPVRSHUDWLRQDO" :HUHDOOVHQVRUVYLVXDOO\LQVSHFWHGIRUNLQNVDQGEUHDNVLQWKHFDEOHVDQGIRUUHVLGXDOEXLOGXSWRHQVXUHWKDWIORDWVPRYHIUHHO\ IXQFWLRQDOO\WHVWHGDQGFRQILUPHGRSHUDWLRQDO" :HUHDOOVHQVRUVLQVWDOOHGDWORZHVWSRLQWRIVHFRQGDU\FRQWDLQPHQWDQGSRVLWLRQHGVRWKDWRWKHUHTXLSPHQWZLOOQRWLQWHUIHUHZLWK WKHLUSURSHURSHUDWLRQ" :DVPRQLWRULQJV\VWHPVHWXSUHYLHZHGWRHQVXUHSURSHUVHWWLQJV" :DVWKHPRQLWRULQJSDQHO¶VEDFNXSEDWWHU\YLVXDOO\LQVSHFWHGIXQFWLRQDOO\WHVWHGDQGFRQILUPHGRSHUDWLRQDO" 'RHVWKHIORZRIIXHOVWRSDWWKHGLVSHQVHULIDOHDNLVGHWHFWHGLQWKHXQGHUGLVSHQVHUFRQWDLQPHQW" 'RHVWKHWXUELQHDXWRPDWLFDOO\VKXWGRZQLIWKHSLSLQJVHFRQGDU\FRQWDLQPHQWPRQLWRULQJV\VWHPIDLOVWRRSHUDWHRULVHOHFWULFDOO\ GLVFRQQHFWHG" 'RHVWKHWXUELQHDXWRPDWLFDOO\VKXWGRZQLIWKHSLSLQJVHFRQGDU\FRQWDLQPHQWPRQLWRULQJV\VWHPGHWHFWVDOHDN" :KLFKVHQVRUVLQLWLDWHSRVLWLYHVKXWGRZQ"(Check all that apply.)6XPS8QGHU'LVSHQVHU&RQWDLQPHQW ,IDODUPVDUHUHOD\HGWRDUHPRWHPRQLWRULQJVWDWLRQLVDOOFRPPXQLFDWLRQVHTXLSPHQW HJPRGHP RSHUDWLRQDO" For any answer of “N” above, describe in Section IX how and when these deficiencies were or will be corrected. ,; &200(176 ; ,17$1.*$8*,1*7(67,1* &KHFNWKLVER[LIWDQNJDXJLQJLVXVHGRQO\IRULQYHQWRU\FRQWURO(Do not complete this section.) <11$&KHFNWKLVER[LI12WDQNJDXJLQJHTXLSPHQWLVLQVWDOOHG (Do not complete this section.) This section must be completed if in-tank gauging is used to perform leak detection monitoring. +DVDOOLQSXWZLULQJEHHQLQVSHFWHGIRUNLQNVDQGEUHDNVLQWKHFDEOHVDQGIRUSURSHUHQWU\DQGWHUPLQDWLRQLQFOXGLQJWHVWLQJIRU JURXQGIDXOWV" :HUHDOOLQWDQNJDXJLQJSUREHVYLVXDOO\LQVSHFWHGIRUGDPDJHDQGUHVLGXHEXLOGXSWRHQVXUHWKDWIORDWVPRYHIUHHO\IXQFWLRQDOO\ WHVWHGDQGFRQILUPHGRSHUDWLRQDO" :DVDFFXUDF\RIV\VWHP¶VSURGXFWOHYHOUHDGLQJVWHVWHG" :DVDFFXUDF\RIV\VWHP¶VZDWHUOHYHOUHDGLQJVWHVWHG" :HUHDOOSUREHVUHLQVWDOOHGSURSHUO\" :HUHDOOLWHPVRQWKHHTXLSPHQWPDQXIDFWXUHU¶VPDLQWHQDQFHFKHFNOLVWFRPSOHWHG" For any answer of “N” above, describe in Section XI how and when these deficiencies were or will be corrected. ;, &200(176 *3+ *DOORQV3HU+RXU< <HV1 1R1$ 1RW$SSOLFDEOH93+ 9DFXXP3UHVVXUH+\GURVWDWLF,' ,GHQWLILFDWLRQ 81 ZZZXQLGRFVRUJ5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  ;,, /,1(/($.'(7(&7257(67,1* &KHFNWKLVER[LIOLQHOHDNGHWHFWRUV //' DUH127LQVWDOOHG(Do not complete this section.)<11$This section must be completed if LLDs are installed. :DVDOHDNVLPXODWHGWRYHULI\//'SHUIRUPDQFH" (Check all that apply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¶VPDLQWHQDQFHFKHFNOLVWFRPSOHWHG" :HUHDOO//'VFRQILUPHGRSHUDWLRQDOZLWKLQUHJXODWRU\UHTXLUHPHQWV" For any answer of “N” above, describe in Section XIII how and when these issues were or will be corrected. ;,,, &200(176 ;,9 9$&88035(6685(+<'5267$7,&021,725,1*(48,30(177(67,1* &KHFNWKLVER[LI93+PRQLWRULQJLV127XVHG(Do not complete this section.) This section must be completed if VPH monitoring is used to perform leak detection monitoring. 6\VWHP7\SH 0DUNDOOWKDWDSSO\ 9DFXXP3UHVVXUH+\GURVWDWLF 6HQVRU,'&RPSRQHQW 6 0RQLWRUHG%\7KLV6HQVRU 6HQVRU)XQFWLRQDOLW\ 7HVW ,QWHUVWLWLDO&RPPXQLFDWLRQ 7HVW 3DVV )DLO 3DVV )DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO +RZZDVLQWHUVWLWLDOFRPPXQLFDWLRQYHULILHG"6LPXODWHG/HDNDW)DU(QGVRIWKH,QWHUVWLWLDO6SDFH9LVXDO,QVSHFWLRQ 2WKHU(Describe the method in section XV below.)*DXJH :DVWKHYDFXXPRUSUHVVXUHUHVWRUHGWRRSHUDWLQJOHYHOVLQDOOLQWHUVWLWLDOVSDFHV"<HV1R(Describe the reason in section XV below.) For any answer of “Fail” above, describe in Section XV how and when these issues were or will be corrected. ;9 &200(176 Express Gas Setup Responses Received: 200 FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 NOV 27, 2019 9:53 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 REGULAR UNL 4511 42.58 0.0 72.2 7516 2 SUPER UNL 2209 33.08 0.0 74.2 5980 I90500 NOV 27, 2019 9:53 AM SOFTWARE REVISION LEVEL VERSION 333.06 SOFTWARE# 346333-100-G CREATED - 14.10.01.16.35 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 NOV 27, 2019 9:53 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 NOV 27, 2019 9:53 AM SHIFT TIME 1 : 2:00 AM I50202 NOV 27, 2019 9:53 AM SHIFT TIME 2 : DISABLED I50203 NOV 27, 2019 9:53 AM SHIFT TIME 3 : DISABLED I50204 NOV 27, 2019 9:53 AM SHIFT TIME 4 : DISABLED I54600 NOV 27, 2019 9:53 AM TANK PER TST NEEDED WRN: DISABLED I54900 NOV 27, 2019 9:53 AM TANK ANN TST NEEDED WRN: DISABLED I55300 NOV 27, 2019 9:53 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 NOV 27, 2019 9:53 AM LINE PER TST NEEDED WRN: DISABLED I55900 NOV 27, 2019 9:53 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 NOV 27, 2019 9:53 AM PRINT TC VOLUMES ENABLED I50E00 NOV 27, 2019 9:53 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 NOV 27, 2019 9:53 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 NOV 27, 2019 9:53 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 NOV 27, 2019 9:53 AM DAYLIGHT SAVING TIME DISABLED I51B00 NOV 27, 2019 9:53 AM I51600 NOV 27, 2019 9:53 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 NOV 27, 2019 9:53 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 NOV 27, 2019 9:53 AM TANK CHART SECURITY DISABLED I5BD00 NOV 27, 2019 9:53 AM CUSTOM ALARM LABELS DISABLED I56000 NOV 27, 2019 9:53 AM MASS/DENSITY DISABLED I88101 NOV 27, 2019 9:53 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 NOV 27, 2019 9:53 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 NOV 27, 2019 9:53 AM PORT SETTINGS: COMM BOARD : 3 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED DTR NORMAL STATE: HIGH I88104 NOV 27, 2019 9:53 AM I88105 NOV 27, 2019 9:53 AM I88106 NOV 27, 2019 9:53 AM I52000 NOV 27, 2019 9:53 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE JUN 26, 2015 DISABLED 2 ON DATE JUN 26, 2015 DISABLED 3 ON DATE JUN 26, 2015 DISABLED 4 ON DATE JUN 26, 2015 DISABLED 5 ON DATE JUN 26, 2015 DISABLED 6 ON DATE JUN 26, 2015 DISABLED 7 ON DATE JUN 26, 2015 DISABLED 8 ON DATE JUN 26, 2015 DISABLED I60100 NOV 27, 2019 9:53 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 REGULAR UNL ON 2 SUPER UNL ON 3 OFF 4 OFF I60200 NOV 27, 2019 9:53 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 REGULAR UNL 2 SUPER UNL 3 4 I60300 NOV 27, 2019 9:53 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 REGULAR UNL 1 2 SUPER UNL 2 3 3 4 4 I60900 NOV 27, 2019 9:53 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 REGULAR UNL 0.000700 2 SUPER UNL 0.000700 3 0.000000 4 0.000000 I60700 NOV 27, 2019 9:53 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 REGULAR UNL 109.00 2 SUPER UNL 109.00 3 0.00 4 0.00 I60A00 NOV 27, 2019 9:53 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 REGULAR UNL 20 PTS 12027 2 SUPER UNL 20 PTS 8189 3 1 PT 0 4 1 PT 0 I60400 NOV 27, 2019 9:53 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 12027 2 SUPER UNL 8189 3 0 4 0 I60500 NOV 27, 2019 9:53 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 12027 9879 6220 2503 2 SUPER UNL 8189 6711 4229 1698 3 0 0 0 0 4 0 0 0 0 I60600 NOV 27, 2019 9:53 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 12027 11916 11547 11066 10511 9879 9196 8493 7745 6979 6220 5441 4648 3920 3204 2503 1850 1245 722 290 2 SUPER UNL 8189 8089 7850 7520 7141 6711 6259 5770 5269 4751 4229 3699 3180 2667 2175 1698 1258 847 490 198 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 NOV 27, 2019 9:53 AM TANK PRODUCT LABEL METER DATA 1 REGULAR UNL NO 2 SUPER UNL NO 3 NO 4 NO I62F00 NOV 27, 2019 9:53 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 REGULAR UNL 4.0 IN. 2 SUPER UNL 4.0 IN. I62700 NOV 27, 2019 9:53 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 REGULAR UNL 3.0 2 SUPER UNL 3.0 I64200 NOV 27, 2019 9:53 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 REGULAR UNL LOW 2 SUPER UNL LOW I62400 NOV 27, 2019 9:53 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 REGULAR UNL 2.0 2 SUPER UNL 2.0 I62800 NOV 27, 2019 9:53 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 12027 2 SUPER UNL 8189 3 0 4 0 I62300 NOV 27, 2019 9:53 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 10824 2 SUPER UNL 7370 3 0 4 0 I62200 NOV 27, 2019 9:53 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 11426 2 SUPER UNL 7780 3 0 4 0 I62900 NOV 27, 2019 9:53 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 1203 2 SUPER UNL 819 3 0 4 0 I62100 NOV 27, 2019 9:53 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 222 2 SUPER UNL 400 3 0 4 0 I62600 NOV 27, 2019 9:53 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 99 2 SUPER UNL 99 3 99 4 99 I62500 NOV 27, 2019 9:53 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 99 2 SUPER UNL 99 3 99 4 99 I60800 NOV 27, 2019 9:53 AM TANK TILT TANK PRODUCT LABEL INCHES 1 REGULAR UNL 0.00 2 SUPER UNL 0.00 3 0.00 4 0.00 I60B00 NOV 27, 2019 9:53 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 NOV 27, 2019 9:53 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 REGULAR UNL 0.00 2 SUPER UNL 0.00 3 0.00 4 0.00 I61200 NOV 27, 2019 9:53 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 REGULAR UNL NONE NONE 2 SUPER UNL NONE NONE 3 NONE NONE 4 NONE NONE I63600 NOV 27, 2019 9:53 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 1202 2 SUPER UNL 818 3 0 4 0 I62A00 NOV 27, 2019 9:53 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 1202 2 SUPER UNL 818 3 0 4 0 I62C00 NOV 27, 2019 9:53 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 REGULAR UNL STANDARD 2 SUPER UNL STANDARD 3 STANDARD 4 STANDARD I62D00 NOV 27, 2019 9:53 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 REGULAR UNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 SUPER UNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 NOV 27, 2019 9:53 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 REGULAR UNL OFF OFF 2 SUPER UNL OFF OFF 3 OFF OFF 4 OFF OFF I63000 NOV 27, 2019 9:53 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 REGULAR UNL OFF 2 SUPER UNL OFF 3 OFF 4 OFF I63200 NOV 27, 2019 9:53 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 REGULAR UNL OFF 2 SUPER UNL OFF 3 OFF 4 OFF I61000 NOV 27, 2019 9:53 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 REGULAR UNL 1 2 SUPER UNL 1 3 1 4 1 I63A00 NOV 27, 2019 9:53 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 REGULAR UNL 10.00% 2 SUPER UNL 10.00% 3 10.00% 4 10.00% I61100 NOV 27, 2019 9:53 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK OCT 1, 2014 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 NOV 27, 2019 9:53 AM CSLD PROBABLITY OF DETECTION I61400 NOV 27, 2019 9:53 AM CSLD CLIMATE FACTOR I61600 NOV 27, 2019 9:53 AM TANK PRODUCT LABEL CAL UPDATE 1 REGULAR UNL IMMEDIATE 2 SUPER UNL IMMEDIATE 3 IMMEDIATE 4 IMMEDIATE I61A00 NOV 27, 2019 9:53 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 REGULAR UNL DISABLED 2 SUPER UNL DISABLED 3 DISABLED 4 DISABLED I61B00 NOV 27, 2019 9:53 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 NOV 27, 2019 9:53 AM CSLD REPORT ONLY I62B00 NOV 27, 2019 9:53 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 REGULAR UNL ??? 0, 0 2 SUPER UNL ??? 0, 0 3 ??? 0, 0 4 ??? 0, 0 I63300 NOV 27, 2019 9:54 AM LEAK TEST REPORT FORMAT: NORMAL I63400 NOV 27, 2019 9:54 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 0 2 SUPER UNL 0 3 0 4 0 I63500 NOV 27, 2019 9:54 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 1 2 SUPER UNL 1 3 1 4 1 I63900 NOV 27, 2019 9:54 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 REGULAR UNL END FACTOR: NONE 2 SUPER UNL END FACTOR: NONE 3 END FACTOR: NONE 4 END FACTOR: NONE I78000 NOV 27, 2019 9:54 AM I77700 NOV 27, 2019 9:54 AM I77800 NOV 27, 2019 9:54 AM I78C00 NOV 27, 2019 9:54 AM I78300 NOV 27, 2019 9:54 AM I78F00 NOV 27, 2019 9:54 AM I78700 NOV 27, 2019 9:54 AM I70200 NOV 27, 2019 9:54 AM LIQUID LABEL DEVICE LABEL 1 87-91 ANNULAR 2 87 STP 3 87 FILL 4 91 STP 5 91 FILL 6 DISP 1-2 7 DISP 3-4 8 DISP 5-6 9 DISP 7-8 10 DISP 9-10 11 DISP 11-12 12 DISP 7-8 13 14 15 16 I70300 NOV 27, 2019 9:54 AM LIQUID TYPE SENSOR LOCATION TYPE 1 87-91 ANNULAR TRI-STATE (SINGLE FLOAT) 2 87 STP TRI-STATE (SINGLE FLOAT) 3 87 FILL TRI-STATE (SINGLE FLOAT) 4 91 STP TRI-STATE (SINGLE FLOAT) 5 91 FILL TRI-STATE (SINGLE FLOAT) 6 DISP 1-2 TRI-STATE (SINGLE FLOAT) 7 DISP 3-4 TRI-STATE (SINGLE FLOAT) 8 DISP 5-6 TRI-STATE (SINGLE FLOAT) 9 DISP 7-8 TRI-STATE (SINGLE FLOAT) 10 DISP 9-10 TRI-STATE (SINGLE FLOAT) 11 DISP 11-12 TRI-STATE (SINGLE FLOAT) 12 DISP 7-8 TRI-STATE (SINGLE FLOAT) 13 TRI-STATE (SINGLE FLOAT) 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 NOV 27, 2019 9:54 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 87-91 ANNULAR ANNULAR SPACE 2 87 STP STP SUMP 3 87 FILL PIPING SUMP 4 91 STP STP SUMP 5 91 FILL PIPING SUMP 6 DISP 1-2 DISPENSER PAN 7 DISP 3-4 DISPENSER PAN 8 DISP 5-6 DISPENSER PAN 9 DISP 7-8 DISPENSER PAN 10 DISP 9-10 DISPENSER PAN 11 DISP 11-12 DISPENSER PAN 12 DISP 7-8 DISPENSER PAN 13 OTHER SENSORS 14 OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 NOV 27, 2019 9:54 AM I74300 NOV 27, 2019 9:54 AM I74400 NOV 27, 2019 9:54 AM I74700 NOV 27, 2019 9:54 AM I74800 NOV 27, 2019 9:54 AM I74900 NOV 27, 2019 9:54 AM I7BC00 NOV 27, 2019 9:54 AM I80200 NOV 27, 2019 9:54 AM I80300 NOV 27, 2019 9:54 AM I80400 NOV 27, 2019 9:54 AM I80700 NOV 27, 2019 9:54 AM RELAY LABEL DEVICE LABEL 1 REGULAR UNL 2 SUPER UNL 3 OVERFILL 4 I80900 NOV 27, 2019 9:54 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 REGULAR UNL NORMALLY CLOSED 2 SUPER UNL NORMALLY CLOSED 3 OVERFILL NORMALLY OPEN 4 NORMALLY OPEN I80B00 NOV 27, 2019 9:54 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 REGULAR UNL 1 2 SUPER UNL 2 3 OVERFILL NONE 4 NONE I80A00 NOV 27, 2019 9:54 AM RELAY TYPE RELAY DESIGNATION TYPE 1 REGULAR UNL STANDARD 2 SUPER UNL STANDARD 3 OVERFILL STANDARD 4 STANDARD I80C00 NOV 27, 2019 9:54 AM I80800 NOV 27, 2019 9:54 AM RELAY SETUP REPORT R 1:REGULAR UNL TYPE: STANDARD NORMALLY CLOSED TANK #: 1 IN-TANK ALARMS T 1:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 2:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 2:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 2:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL PMC ALARMS VP EMISSIONS FAIL VP PRESSURE FAIL VP DUTY CYCLE FAIL PMC SETUP FAIL R 2:SUPER UNL TYPE: STANDARD NORMALLY CLOSED TANK #: 2 IN-TANK ALARMS T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 4:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 4:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL PMC ALARMS VP EMISSIONS FAIL VP PRESSURE FAIL VP DUTY CYCLE FAIL R 3:OVERFILL TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 NOV 27, 2019 9:54 AM EDIM:1 VR:349643-001-B TD:97.10.27.11.25 I79100 NOV 27, 2019 9:54 AM I72300 NOV 27, 2019 9:54 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 VAPOR PRESSUR VAPOR PRESSURE 02 FM 1-2 AIR FLOW METER 03 FM 3-4 AIR FLOW METER 04 FM 5-6 AIR FLOW METER 05 FM 7-8 AIR FLOW METER 06 FM 9-10 AIR FLOW METER 07 FM 11-12 AIR FLOW METER 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 NOV 27, 2019 9:54 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 NOV 27, 2019 9:54 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 NOV 27, 2019 9:54 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 VAPOR PROCESSOR TYPE NONE IV4700 NOV 27, 2019 9:54 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 ASSESSMENT TIME START TIME: 6:00 AM TIME DELAY MINUTES: 1 IV5200 NOV 27, 2019 9:54 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 ACCEPT HIGH ORVR: NO IV4A00 NOV 27, 2019 9:54 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 09 09 09 05 02 BLEND3 10 16 10 05 02 BLEND3 11 17 11 06 02 BLEND3 12 18 12 06 02 BLEND3 IV4B00 NOV 27, 2019 9:54 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 09/01 01/01 xx/xx 02 01 02/02 09/02 01/02 xx/xx 03 02 02/03 09/03 01/03 xx/xx 04 02 02/04 09/04 01/04 xx/xx 05 03 02/05 09/05 01/05 xx/xx 06 03 02/06 09/06 01/06 xx/xx 07 04 02/07 09/07 01/07 xx/xx 08 04 09/08 02/08 01/08 xx/xx 09 05 02/09 09/09 01/09 xx/xx 16 05 02/10 09/10 01/10 xx/xx 17 06 02/11 09/11 01/11 xx/xx 18 06 02/12 09/12 01/12 xx/xx IV4900 NOV 27, 2019 9:54 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 NOV 27, 2019 9:54 AM ISD VERSION: 01.05 Express Gas Alarm History Responses Received: I10200 NOV 27, 2019 9:55 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 UNUSED 10457924 10318873 2 UNUSED 10331431 10293492 3 UNUSED 10312623 10279409 4 8SMARTSENSOR BD 39519 39576 5 4 PROBE / G.T. 163572 163646 6 INTERSTITIAL BD 201659 201555 7 INTERSTITIAL BD 201747 201826 8 UNUSED 10331048 10293644 9 UNUSED 10314410 10283522 10 RELAY BOARD 14965 14993 11 UNUSED 10317088 10283913 12 UNUSED 10306036 10287875 13 UNUSED 10308587 10280322 14 UNUSED 10311371 10283804 15 UNUSED 10310818 10287853 16 UNUSED 10307503 10286852 COMM 1 ELEC DISP INT. 100670 100776 COMM 2 RS232 SERIAL BD 14901 14949 COMM 3 SERIAL SAT BD 484996 485111 COMM 4 UNUSED 10316238 10296712 COMM 5 UNUSED 10299002 10284327 COMM 6 UNUSED 10303019 10290988 I90200 NOV 27, 2019 9:55 AM SOFTWARE REVISION LEVEL VERSION 333.06 SOFTWARE# 346333-100-G CREATED - 14.10.01.16.35 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 NOV 27, 2019 9:55 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h 8 OTHER FP8: BLEND3 DEGRD COLLECT FAIL ALARM 11-27-19 6:02AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT FAIL CLEAR 11-27-19 6:02AM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-26-19 6:32AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-26-19 6:30AM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-26-19 6:22AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-26-19 6:16AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT FAIL ALARM 11-26-19 6:02AM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-24-19 12:13PM E 1 OTHER G COMMUNICATION ALARM ALARM 11-24-19 12:07PM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-21-19 11:00AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-21-19 10:55AM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-21-19 5:28AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-21-19 5:23AM L 5 PIPE 91 FILL FUEL ALARM ALARM 11-20-19 1:56PM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-17-19 4:03AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-17-19 3:57AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT FAIL CLEAR 11-15-19 7:13AM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-15-19 6:37AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-15-19 6:35AM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-15-19 6:32AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-15-19 6:30AM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-15-19 6:25AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-15-19 6:23AM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-15-19 6:20AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-15-19 6:15AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT FAIL ALARM 11-15-19 6:03AM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-10-19 3:59AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-10-19 3:58AM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-09-19 4:32AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-09-19 4:27AM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-08-19 5:34AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-08-19 5:26AM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-07-19 5:28AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-07-19 5:24AM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-06-19 5:29AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-06-19 5:24AM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-05-19 10:30AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-05-19 10:26AM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-04-19 10:39PM E 1 OTHER G COMMUNICATION ALARM ALARM 11-04-19 10:37PM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-04-19 10:28PM E 1 OTHER G COMMUNICATION ALARM ALARM 11-04-19 10:24PM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-04-19 10:21PM E 1 OTHER G COMMUNICATION ALARM ALARM 11-04-19 10:04PM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-03-19 4:01AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-03-19 3:58AM T 1 TANK REGULAR UNL OVERFILL ALARM CLEAR 10-30-19 9:45PM T 1 TANK REGULAR UNL OVERFILL ALARM ALARM 10-30-19 9:40PM E 1 OTHER G COMMUNICATION ALARM CLEAR 10-27-19 2:59AM E 1 OTHER G COMMUNICATION ALARM ALARM 10-27-19 2:57AM I11200 NOV 27, 2019 9:55 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 11-26-19 6:00AM OTHER ISD GROSS PRES WARN CLEAR 11-23-19 7:17AM OTHER ISD GROSS PRES WARN ALARM 11-22-19 6:02AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 11-21-19 6:00AM SYSTEM PRINTER ERROR CLEAR 11-20-19 2:00PM SYSTEM PAPER OUT CLEAR 11-20-19 2:00PM SYSTEM PRINTER ERROR ALARM 11-20-19 6:13AM SYSTEM PAPER OUT ALARM 11-20-19 6:13AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 11-20-19 6:02AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 11-20-19 6:00AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 11-19-19 6:02AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 11-16-19 6:03AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 11-15-19 6:00AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 11-15-19 6:00AM OTHER ISD GROSS PRES WARN CLEAR 11-14-19 5:54PM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 11-14-19 6:03AM OTHER ISD GROSS PRES WARN ALARM 11-13-19 6:03AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 11-08-19 6:01AM OTHER ISD GROSS PRES WARN CLEAR 11-06-19 8:49AM OTHER ISD GROSS PRES WARN ALARM 11-06-19 6:01AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 11-05-19 6:00AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 11-04-19 6:02AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 11-03-19 6:00AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 11-02-19 6:01AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 10-30-19 6:00AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 10-29-19 6:01AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 10-26-19 6:00AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 10-22-19 6:01AM SYSTEM PRINTER ERROR CLEAR 10-17-19 8:37PM SYSTEM PAPER OUT CLEAR 10-17-19 8:37PM SYSTEM PRINTER ERROR ALARM 10-17-19 8:26PM SYSTEM PAPER OUT ALARM 10-17-19 8:26PM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 10-16-19 10:33AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 10-16-19 10:33AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 10-16-19 6:01AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 10-16-19 6:00AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 10-16-19 6:00AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 10-15-19 6:01AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 10-14-19 6:01AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 10-14-19 6:00AM T 2 TANK SUPER UNL DELIVERY NEEDED CLEAR 10-13-19 10:35AM T 2 TANK SUPER UNL DELIVERY NEEDED ALARM 10-13-19 6:26AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 10-13-19 6:00AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 10-11-19 6:01AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 10-11-19 6:01AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 10-09-19 6:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 10-08-19 1:35PM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 10-05-19 6:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 10-04-19 6:00AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 9-27-19 6:01AM I20600 NOV 27, 2019 9:55 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 TANK ALARM HISTORY TANK 1 REGULAR UNL HIGH WATER ALARM DEC 3, 2015 9:46 AM OVERFILL ALARM OCT 30, 2019 9:40 PM OCT 13, 2019 10:44 AM SEP 29, 2019 2:23 PM HIGH PRODUCT ALARM NOV 13, 2018 11:10 AM NOV 6, 2017 11:29 AM NOV 8, 2016 11:56 AM INVALID FUEL LEVEL FEB 24, 2018 9:17 PM FEB 2, 2018 9:34 PM NOV 6, 2017 11:30 AM PROBE OUT NOV 13, 2018 11:13 AM NOV 13, 2018 11:07 AM NOV 8, 2016 11:57 AM HIGH WATER WARNING DEC 3, 2015 9:46 AM DELIVERY NEEDED SEP 11, 2019 7:07 PM FEB 24, 2018 3:35 PM FEB 21, 2018 10:04 AM MAX PRODUCT ALARM NOV 13, 2018 11:10 AM LOW TEMP WARNING NOV 8, 2016 11:58 AM DEC 3, 2015 10:17 AM DEC 3, 2015 10:13 AM TANK 2 SUPER UNL OVERFILL ALARM DEC 3, 2015 10:08 AM LOW PRODUCT ALARM MAR 3, 2018 12:27 PM FEB 28, 2018 8:47 PM JAN 29, 2018 10:10 AM HIGH PRODUCT ALARM NOV 13, 2018 11:11 AM NOV 6, 2017 11:27 AM NOV 8, 2016 12:01 PM INVALID FUEL LEVEL NOV 13, 2018 11:12 AM NOV 6, 2017 11:28 AM NOV 6, 2017 10:16 AM PROBE OUT NOV 13, 2018 11:12 AM NOV 13, 2018 11:09 AM NOV 8, 2016 12:02 PM DELIVERY NEEDED OCT 13, 2019 6:26 AM NOV 13, 2018 11:09 AM MAR 2, 2018 10:58 AM MAX PRODUCT ALARM NOV 13, 2018 11:11 AM LOW TEMP WARNING DEC 3, 2015 10:11 AM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 NOV 27, 2019 9:56 AM I30200 NOV 27, 2019 9:56 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87-91 ANNULAR NOV 13, 2018 2:18 PM FUEL ALARM NOV 13, 2018 10:03 AM FUEL ALARM NOV 6, 2017 11:08 AM FUEL ALARM 2 87 STP NOV 13, 2018 9:40 AM FUEL ALARM NOV 6, 2017 10:47 AM FUEL ALARM NOV 8, 2016 1:20 PM SENSOR OUT ALARM 3 87 FILL MAY 18, 2019 9:16 PM FUEL ALARM MAR 5, 2019 3:05 PM FUEL ALARM JAN 31, 2019 8:41 AM FUEL ALARM 4 91 STP NOV 13, 2018 9:43 AM FUEL ALARM NOV 6, 2017 10:47 AM FUEL ALARM NOV 8, 2016 1:20 PM SENSOR OUT ALARM 5 91 FILL NOV 20, 2019 1:56 PM FUEL ALARM MAY 16, 2019 9:29 PM FUEL ALARM MAR 2, 2019 4:00 AM FUEL ALARM 6 DISP 1-2 NOV 13, 2018 9:47 AM FUEL ALARM NOV 6, 2017 11:18 AM FUEL ALARM NOV 8, 2016 1:20 PM SENSOR OUT ALARM 7 DISP 3-4 NOV 13, 2018 9:47 AM FUEL ALARM NOV 6, 2017 11:19 AM FUEL ALARM NOV 8, 2016 1:20 PM SENSOR OUT ALARM 8 DISP 5-6 NOV 13, 2018 9:49 AM FUEL ALARM NOV 6, 2017 11:12 AM FUEL ALARM NOV 8, 2016 1:20 PM SENSOR OUT ALARM 10 DISP 9-10 NOV 13, 2018 9:45 AM FUEL ALARM NOV 6, 2017 11:23 AM FUEL ALARM NOV 8, 2016 1:20 PM SENSOR OUT ALARM 11 DISP 11-12 NOV 13, 2018 9:46 AM FUEL ALARM NOV 6, 2017 11:24 AM FUEL ALARM NOV 8, 2016 1:19 PM SENSOR OUT ALARM 12 DISP 7-8 NOV 13, 2018 9:49 AM FUEL ALARM NOV 6, 2017 11:14 AM FUEL ALARM NOV 8, 2016 1:20 PM SENSOR OUT ALARM I31600 NOV 27, 2019 9:56 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 VAPOR PRESSUR 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 6 FM 9-10 7 FM 11-12 I40200 NOV 27, 2019 9:56 AM I40300 NOV 27, 2019 9:56 AM I34200 NOV 27, 2019 9:56 AM I34700 NOV 27, 2019 9:56 AM IV0100 NOV 27, 2019 9:56 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.05 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :FAIL EVR VAPOR COLLECTION :FAIL EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME : 0% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 19-11-25 06:02:16 A/L RATIO DEGRADATION FP 8 BLEND3 0.70 19-11-24 06:02:40 A/L RATIO DEGRADATION FP 8 BLEND3 0.70 19-11-23 06:02:03 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.67 19-11-23 06:02:03 A/L RATIO DEGRADATION FP 8 BLEND3 0.71 19-11-22 06:02:06 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.67 19-11-22 06:02:06 A/L RATIO DEGRADATION FP 8 BLEND3 0.71 19-11-21 06:02:00 A/L RATIO DEGRADATION FP 8 BLEND3 0.78 19-11-20 06:02:25 A/L RATIO DEGRADATION FP 8 BLEND3 0.77 19-11-20 06:02:25 A/L RATIO DEGRADATION FP 5 BLEND3 0.81 19-11-19 06:02:51 A/L RATIO DEGRADATION FP12 BLEND3 0.74 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 19-11-27 06:02:33 A/L RATIO DEGRADATION FP 8 BLEND3 0.72 19-11-26 06:02:22 A/L RATIO DEGRADATION FP 8 BLEND3 0.71 19-11-15 06:03:38 A/L RATIO DEGRADATION FP 8 BLEND3 0.75 19-09-10 06:01:51 A/L RATIO DEGRADATION FP12 BLEND3 0.75 19-09-10 06:01:50 A/L RATIO DEGRADATION FP 9 BLEND3 0.77 19-09-10 06:01:50 A/L RATIO DEGRADATION FP 4 BLEND3 0.79 19-09-09 06:01:09 A/L RATIO DEGRADATION FP12 BLEND3 0.76 19-09-09 06:01:09 A/L RATIO DEGRADATION FP 9 BLEND3 0.79 19-09-09 06:01:09 A/L RATIO DEGRADATION FP 4 BLEND3 0.79 19-09-08 06:01:09 A/L RATIO DEGRADATION FP12 BLEND3 0.77 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 19-11-27 06:28:32 PUMPS MANUALLY RE-ENABLED 19-11-27 06:02:33 A/L RATIO GROSS DEGRADATION DISABLED FP 08 BLEND3 19-11-26 06:42:41 PUMPS MANUALLY RE-ENABLED 19-11-26 06:02:22 A/L RATIO GROSS DEGRADATION DISABLED FP 08 BLEND3 19-11-23 07:17:54 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 19-11-15 07:13:58 COLLECTION TEST HH08 GRADE TEST MANUALLY CLEARED 19-11-15 07:10:41 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 19-11-15 06:56:45 PUMPS MANUALLY RE-ENABLED 19-11-15 06:03:38 A/L RATIO GROSS DEGRADATION DISABLED FP 08 BLEND3 19-11-14 17:54:50 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED Express Gas Alarm History After Responses Received: I10200 NOV 27, 2019 12:00 PM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 UNUSED 10457924 10195847 2 UNUSED 10331431 10175791 3 UNUSED 10312623 10180363 4 8SMARTSENSOR BD 39519 39466 5 4 PROBE / G.T. 163572 163198 6 INTERSTITIAL BD 201659 201219 7 INTERSTITIAL BD 201747 201334 8 UNUSED 10331048 10189552 9 UNUSED 10314410 10176747 10 RELAY BOARD 14965 14970 11 UNUSED 10317088 10178955 12 UNUSED 10306036 10173500 13 UNUSED 10308587 10180722 14 UNUSED 10311371 10174582 15 UNUSED 10310818 10181275 16 UNUSED 10307503 10176945 COMM 1 ELEC DISP INT. 100670 100506 COMM 2 RS232 SERIAL BD 14901 14904 COMM 3 SERIAL SAT BD 484996 483857 COMM 4 UNUSED 10316238 10183285 COMM 5 UNUSED 10299002 10178911 COMM 6 UNUSED 10303019 10182136 I90200 NOV 27, 2019 12:00 PM SOFTWARE REVISION LEVEL VERSION 333.06 SOFTWARE# 346333-100-G CREATED - 14.10.01.16.35 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 NOV 27, 2019 12:00 PM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 4 STP SUMP 91 STP SENSOR OUT ALARM CLEAR 11-27-19 11:59AM L 3 PIPE 87 FILL SENSOR OUT ALARM CLEAR 11-27-19 11:59AM L 2 STP SUMP 87 STP SENSOR OUT ALARM CLEAR 11-27-19 11:59AM L 8 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 11-27-19 11:59AM L 7 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 11-27-19 11:59AM L 6 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 11-27-19 11:59AM L 1 ANNULAR 87-91 ANNULAR SENSOR OUT ALARM CLEAR 11-27-19 11:59AM L 5 PIPE 91 FILL SENSOR OUT ALARM CLEAR 11-27-19 11:59AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 11-27-19 11:59AM L11 DISP PAN DISP 11-12 SENSOR OUT ALARM CLEAR 11-27-19 11:59AM L10 DISP PAN DISP 9-10 SENSOR OUT ALARM CLEAR 11-27-19 11:59AM L 4 STP SUMP 91 STP SENSOR OUT ALARM ALARM 11-27-19 11:59AM L 3 PIPE 87 FILL SENSOR OUT ALARM ALARM 11-27-19 11:59AM L 2 STP SUMP 87 STP SENSOR OUT ALARM ALARM 11-27-19 11:59AM L 8 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 11-27-19 11:59AM L 7 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 11-27-19 11:59AM L 6 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 11-27-19 11:59AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 11-27-19 11:59AM L10 DISP PAN DISP 9-10 SENSOR OUT ALARM ALARM 11-27-19 11:59AM L 1 ANNULAR 87-91 ANNULAR SENSOR OUT ALARM ALARM 11-27-19 11:59AM L 5 PIPE 91 FILL SENSOR OUT ALARM ALARM 11-27-19 11:59AM L11 DISP PAN DISP 11-12 SENSOR OUT ALARM ALARM 11-27-19 11:59AM T 1 TANK REGULAR UNL PROBE OUT CLEAR 11-27-19 11:40AM T 1 TANK REGULAR UNL PROBE OUT ALARM 11-27-19 11:39AM T 2 TANK SUPER UNL LOW PRODUCT ALARM CLEAR 11-27-19 11:38AM T 2 TANK SUPER UNL PROBE OUT CLEAR 11-27-19 11:38AM T 2 TANK SUPER UNL PROBE OUT ALARM 11-27-19 11:38AM T 2 TANK SUPER UNL LOW PRODUCT ALARM ALARM 11-27-19 11:23AM T 2 TANK SUPER UNL PROBE OUT CLEAR 11-27-19 11:22AM T 2 TANK SUPER UNL PROBE OUT ALARM 11-27-19 11:21AM T 2 TANK SUPER UNL PROBE OUT CLEAR 11-27-19 11:18AM T 1 TANK REGULAR UNL PROBE OUT CLEAR 11-27-19 11:17AM T 2 TANK SUPER UNL PROBE OUT ALARM 11-27-19 11:17AM T 1 TANK REGULAR UNL PROBE OUT ALARM 11-27-19 11:16AM L 1 ANNULAR 87-91 ANNULAR FUEL ALARM CLEAR 11-27-19 11:09AM L 1 ANNULAR 87-91 ANNULAR FUEL ALARM ALARM 11-27-19 11:09AM L 1 ANNULAR 87-91 ANNULAR SENSOR OUT ALARM CLEAR 11-27-19 11:08AM L 1 ANNULAR 87-91 ANNULAR SENSOR OUT ALARM ALARM 11-27-19 11:02AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT FAIL CLEAR 11-27-19 10:47AM L11 DISP PAN DISP 11-12 FUEL ALARM CLEAR 11-27-19 10:39AM L11 DISP PAN DISP 11-12 FUEL ALARM ALARM 11-27-19 10:39AM L10 DISP PAN DISP 9-10 FUEL ALARM CLEAR 11-27-19 10:39AM L10 DISP PAN DISP 9-10 FUEL ALARM ALARM 11-27-19 10:39AM L 7 DISP PAN DISP 3-4 FUEL ALARM CLEAR 11-27-19 10:38AM L 7 DISP PAN DISP 3-4 FUEL ALARM ALARM 11-27-19 10:38AM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 11-27-19 10:37AM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 11-27-19 10:37AM L 8 DISP PAN DISP 5-6 FUEL ALARM CLEAR 11-27-19 10:37AM L 8 DISP PAN DISP 5-6 FUEL ALARM ALARM 11-27-19 10:36AM L 6 DISP PAN DISP 1-2 FUEL ALARM CLEAR 11-27-19 10:36AM I11200 NOV 27, 2019 12:00 PM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK REGULAR UNL LOW TEMP WARNING CLEAR 11-27-19 11:42AM T 1 TANK REGULAR UNL LOW TEMP WARNING ALARM 11-27-19 11:40AM T 1 TANK REGULAR UNL HIGH PRODUCT ALARM CLEAR 11-27-19 11:39AM T 1 TANK REGULAR UNL HIGH PRODUCT ALARM ALARM 11-27-19 11:39AM T 2 TANK SUPER UNL DELIVERY NEEDED CLEAR 11-27-19 11:38AM T 2 TANK SUPER UNL DELIVERY NEEDED ALARM 11-27-19 11:23AM T 2 TANK SUPER UNL LOW TEMP WARNING CLEAR 11-27-19 11:22AM T 2 TANK SUPER UNL LOW TEMP WARNING ALARM 11-27-19 11:22AM T 2 TANK SUPER UNL HIGH PRODUCT ALARM CLEAR 11-27-19 11:21AM T 2 TANK SUPER UNL HIGH PRODUCT ALARM ALARM 11-27-19 11:21AM T 1 TANK REGULAR UNL DELIVERY NEEDED CLEAR 11-27-19 11:20AM T 2 TANK SUPER UNL DELIVERY NEEDED CLEAR 11-27-19 11:19AM T 1 TANK REGULAR UNL DELIVERY NEEDED ALARM 11-27-19 11:17AM T 2 TANK SUPER UNL DELIVERY NEEDED ALARM 11-27-19 11:17AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 11-26-19 6:00AM OTHER ISD GROSS PRES WARN CLEAR 11-23-19 7:17AM OTHER ISD GROSS PRES WARN ALARM 11-22-19 6:02AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 11-21-19 6:00AM SYSTEM PRINTER ERROR CLEAR 11-20-19 2:00PM SYSTEM PAPER OUT CLEAR 11-20-19 2:00PM SYSTEM PRINTER ERROR ALARM 11-20-19 6:13AM SYSTEM PAPER OUT ALARM 11-20-19 6:13AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 11-20-19 6:02AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 11-20-19 6:00AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 11-19-19 6:02AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 11-16-19 6:03AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 11-15-19 6:00AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 11-15-19 6:00AM OTHER ISD GROSS PRES WARN CLEAR 11-14-19 5:54PM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 11-14-19 6:03AM OTHER ISD GROSS PRES WARN ALARM 11-13-19 6:03AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 11-08-19 6:01AM OTHER ISD GROSS PRES WARN CLEAR 11-06-19 8:49AM OTHER ISD GROSS PRES WARN ALARM 11-06-19 6:01AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 11-05-19 6:00AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 11-04-19 6:02AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 11-03-19 6:00AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 11-02-19 6:01AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 10-30-19 6:00AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 10-29-19 6:01AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 10-26-19 6:00AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 10-22-19 6:01AM SYSTEM PRINTER ERROR CLEAR 10-17-19 8:37PM SYSTEM PAPER OUT CLEAR 10-17-19 8:37PM SYSTEM PRINTER ERROR ALARM 10-17-19 8:26PM SYSTEM PAPER OUT ALARM 10-17-19 8:26PM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 10-16-19 10:33AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 10-16-19 10:33AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 10-16-19 6:01AM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 10-16-19 6:00AM I20600 NOV 27, 2019 12:01 PM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 TANK ALARM HISTORY TANK 1 REGULAR UNL HIGH WATER ALARM DEC 3, 2015 9:46 AM OVERFILL ALARM OCT 30, 2019 9:40 PM OCT 13, 2019 10:44 AM SEP 29, 2019 2:23 PM HIGH PRODUCT ALARM NOV 27, 2019 11:39 AM NOV 13, 2018 11:10 AM NOV 6, 2017 11:29 AM INVALID FUEL LEVEL FEB 24, 2018 9:17 PM FEB 2, 2018 9:34 PM NOV 6, 2017 11:30 AM PROBE OUT NOV 27, 2019 11:39 AM NOV 27, 2019 11:16 AM NOV 13, 2018 11:13 AM HIGH WATER WARNING DEC 3, 2015 9:46 AM DELIVERY NEEDED NOV 27, 2019 11:17 AM SEP 11, 2019 7:07 PM FEB 24, 2018 3:35 PM MAX PRODUCT ALARM NOV 13, 2018 11:10 AM LOW TEMP WARNING NOV 27, 2019 11:40 AM NOV 8, 2016 11:58 AM DEC 3, 2015 10:17 AM TANK 2 SUPER UNL OVERFILL ALARM DEC 3, 2015 10:08 AM LOW PRODUCT ALARM NOV 27, 2019 11:23 AM MAR 3, 2018 12:27 PM FEB 28, 2018 8:47 PM HIGH PRODUCT ALARM NOV 27, 2019 11:21 AM NOV 13, 2018 11:11 AM NOV 6, 2017 11:27 AM INVALID FUEL LEVEL NOV 13, 2018 11:12 AM NOV 6, 2017 11:28 AM NOV 6, 2017 10:16 AM PROBE OUT NOV 27, 2019 11:38 AM NOV 27, 2019 11:21 AM NOV 27, 2019 11:17 AM DELIVERY NEEDED NOV 27, 2019 11:23 AM NOV 27, 2019 11:17 AM OCT 13, 2019 6:26 AM MAX PRODUCT ALARM NOV 13, 2018 11:11 AM LOW TEMP WARNING NOV 27, 2019 11:22 AM DEC 3, 2015 10:11 AM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 NOV 27, 2019 12:01 PM I30200 NOV 27, 2019 12:01 PM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87-91 ANNULAR NOV 27, 2019 11:59 AM SENSOR OUT ALARM NOV 27, 2019 11:09 AM FUEL ALARM NOV 27, 2019 11:02 AM SENSOR OUT ALARM 2 87 STP NOV 27, 2019 11:59 AM SENSOR OUT ALARM NOV 27, 2019 10:35 AM FUEL ALARM NOV 27, 2019 10:34 AM FUEL ALARM 3 87 FILL NOV 27, 2019 11:59 AM SENSOR OUT ALARM NOV 27, 2019 10:34 AM FUEL ALARM MAY 18, 2019 9:16 PM FUEL ALARM 4 91 STP NOV 27, 2019 11:59 AM SENSOR OUT ALARM NOV 27, 2019 10:33 AM FUEL ALARM NOV 13, 2018 9:43 AM FUEL ALARM 5 91 FILL NOV 27, 2019 11:59 AM SENSOR OUT ALARM NOV 27, 2019 10:33 AM FUEL ALARM NOV 20, 2019 1:56 PM FUEL ALARM 6 DISP 1-2 NOV 27, 2019 11:59 AM SENSOR OUT ALARM NOV 27, 2019 10:36 AM FUEL ALARM NOV 13, 2018 9:47 AM FUEL ALARM 7 DISP 3-4 NOV 27, 2019 11:59 AM SENSOR OUT ALARM NOV 27, 2019 10:38 AM FUEL ALARM NOV 13, 2018 9:47 AM FUEL ALARM 8 DISP 5-6 NOV 27, 2019 11:59 AM SENSOR OUT ALARM NOV 27, 2019 10:36 AM FUEL ALARM NOV 13, 2018 9:49 AM FUEL ALARM 10 DISP 9-10 NOV 27, 2019 11:59 AM SENSOR OUT ALARM NOV 27, 2019 10:39 AM FUEL ALARM NOV 13, 2018 9:45 AM FUEL ALARM 11 DISP 11-12 NOV 27, 2019 11:59 AM SENSOR OUT ALARM NOV 27, 2019 10:39 AM FUEL ALARM NOV 13, 2018 9:46 AM FUEL ALARM 12 DISP 7-8 NOV 27, 2019 11:59 AM SENSOR OUT ALARM NOV 27, 2019 10:37 AM FUEL ALARM NOV 13, 2018 9:49 AM FUEL ALARM I31600 NOV 27, 2019 12:01 PM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 VAPOR PRESSUR 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 6 FM 9-10 7 FM 11-12 I40200 NOV 27, 2019 12:01 PM I40300 NOV 27, 2019 12:01 PM I34200 NOV 27, 2019 12:01 PM I34700 NOV 27, 2019 12:01 PM IV0100 NOV 27, 2019 12:01 PM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.05 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :FAIL EVR VAPOR COLLECTION :FAIL EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME : 0% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 19-11-25 06:02:16 A/L RATIO DEGRADATION FP 8 BLEND3 0.70 19-11-24 06:02:40 A/L RATIO DEGRADATION FP 8 BLEND3 0.70 19-11-23 06:02:03 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.67 19-11-23 06:02:03 A/L RATIO DEGRADATION FP 8 BLEND3 0.71 19-11-22 06:02:06 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.67 19-11-22 06:02:06 A/L RATIO DEGRADATION FP 8 BLEND3 0.71 19-11-21 06:02:00 A/L RATIO DEGRADATION FP 8 BLEND3 0.78 19-11-20 06:02:25 A/L RATIO DEGRADATION FP 8 BLEND3 0.77 19-11-20 06:02:25 A/L RATIO DEGRADATION FP 5 BLEND3 0.81 19-11-19 06:02:51 A/L RATIO DEGRADATION FP12 BLEND3 0.74 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 19-11-27 06:02:33 A/L RATIO DEGRADATION FP 8 BLEND3 0.72 19-11-26 06:02:22 A/L RATIO DEGRADATION FP 8 BLEND3 0.71 19-11-15 06:03:38 A/L RATIO DEGRADATION FP 8 BLEND3 0.75 19-09-10 06:01:51 A/L RATIO DEGRADATION FP12 BLEND3 0.75 19-09-10 06:01:50 A/L RATIO DEGRADATION FP 9 BLEND3 0.77 19-09-10 06:01:50 A/L RATIO DEGRADATION FP 4 BLEND3 0.79 19-09-09 06:01:09 A/L RATIO DEGRADATION FP12 BLEND3 0.76 19-09-09 06:01:09 A/L RATIO DEGRADATION FP 9 BLEND3 0.79 19-09-09 06:01:09 A/L RATIO DEGRADATION FP 4 BLEND3 0.79 19-09-08 06:01:09 A/L RATIO DEGRADATION FP12 BLEND3 0.77 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 19-11-27 11:58:41 READINESS ISD:PP EVR:NN EVR READINESS PENDING 19-11-27 11:58:41 ISD STARTUP 19-11-27 11:58:31 ISD SHUTDOWN 19-11-27 10:47:19 COLLECTION TEST HH08 GRADE TEST MANUALLY CLEARED 19-11-27 06:28:32 PUMPS MANUALLY RE-ENABLED 19-11-27 06:02:33 A/L RATIO GROSS DEGRADATION DISABLED FP 08 BLEND3 19-11-26 06:42:41 PUMPS MANUALLY RE-ENABLED 19-11-26 06:02:22 A/L RATIO GROSS DEGRADATION DISABLED FP 08 BLEND3 19-11-23 07:17:54 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 19-11-15 07:13:58 COLLECTION TEST HH08 GRADE TEST MANUALLY CLEARED &(56 &DOLIRUQLD(QYLURQPHQWDO5HSRUWLQJ6\VWHP,' ,GHQWLILFDWLRQ867 8QGHUJURXQG6WRUDJH7DQN,&& ,QWHUQDWLRQDO&RGH&RXQFLO 81 ZZZXQLGRFVRUJ5HY 81'(5*5281'6725$*(7$1. 63,//&217$,1(57(67,1*5(3257)250 3DJHRI  7\SHRI$FWLRQ,QVWDOODWLRQ7HVW5HSDLU7HVW0RQWK7HVW , )$&,/,7<,1)250$7,21 &(56,''DWHRI6SLOO&RQWDLQHU7HVW %XVLQHVV1DPH(Same as Facility Name or DBA-Doing Business As) %XVLQHVV6LWH$GGUHVV &LW\ =,3&RGH ,, 81'(5*5281'6725$*(7$1.6(59,&(7(&+1,&,$1,1)250$7,21 1DPHRI8676HUYLFH7HFKQLFLDQ3HUIRUPLQJWKH7HVW(Print as shown on the ICC Certification.) 3KRQH &RQWUDFWRU7DQN7HVWHU/LFHQVH ,&&&HUWLILFDWLRQ ,&&&HUWLILFDWLRQ([SLUDWLRQ'DWH 6SLOO&RQWDLQHU7HVWLQJ7UDLQLQJDQG&HUWLILFDWLRQV(List applicable certifications.) ,,, 63,//&217$,1(57(67,1*,1)250$7,21 7HVW0HWKRG8VHG0DQXIDFWXUHU*XLGHOLQHV(Specify) ,QGXVWU\&RGHRU(QJLQHHULQJ6WDQGDUG (Specify) (QJLQHHUHG0HWKRG(Specify) Attach the testing procedures and all documentation required to determine the results.RI$WWDFKHG3DJHV 7$1.,'(By tank number, stored product, etc.) 6SLOO&RQWDLQHU0DQXIDFWXUHU 0HWKRGRI&DWKRGLF3URWHFWLRQ1RQ0HWDOOLF1RQ0HWDOOLF1RQ0HWDOOLF1RQ0HWDOOLF ,VRODWLRQ,VRODWLRQ,VRODWLRQ,VRODWLRQ 2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.) ,QVLGH'LDPHWHURI6SLOO&RQWDLQHU(Inches) 'HSWKRI6SLOO&RQWDLQHU(Inches) 'RHVWKHVSLOOFRQWDLQHUKDYHDJDOORQFDSDFLW\"<HV1R<HV1R<HV1R<HV1R 0HWKRGWR.HHS6SLOO&RQWDLQHU(PSW\'UDLQ9DOYH'UDLQ9DOYH'UDLQ9DOYH'UDLQ9DOYH 2QVLWH3XPS2QVLWH3XPS2QVLWH3XPS2QVLWH3XPS 2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.) ,9 6800$5<2)7(67,1*5(68/76 6SLOO&RQWDLQHU7HVW5HVXOWV3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO 9 &200(176 Any items marked “Fail” above must be explained in this section. Any additional comments may also be provided here. 9, &(57,),&$7,21%<8676(59,&(7(&+1,&,$1&21'8&7,1*7+,67(67,1* ,KHUHE\FHUWLI\WKDWWKHVSLOOFRQWDLQHUVZHUHWHVWHGLQDFFRUGDQFHZLWK&DOLIRUQLD&RGHRI5HJXODWLRQV7LWOH'LYLVLRQ &KDSWHU6HFWLRQDQGDOOWKHLQIRUPDWLRQFRQWDLQHGKHUHLQLVDFFXUDWH 8676HUYLFH7HFKQLFLDQ6LJQDWXUH If the facility has more components than this form accommodates, additional copies of this page may be attached. Bakersfield 93305 804904 8485827 9/14/2020 FFS 1010993708 PEI 1200 1 T1 Unl Philtite 11.00” 14.50” T2 Prem Philtite 11.00” 14.50” Aaron Perrigo (800) 339-9930 10125616 11/27/2019 Express Gas 928 Flower Street SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: Date of Testing: Facility Address: Facility Contact: Phone: Date Local Agency Was Notified of Testing : Name of Local Agency Inspector (if present during testing): 2. TESTING CONTRACTOR INFORMATION Company Name: Technician Conducting Test: Credentials1: CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) __________________ License Number(s): 3. SPILL BUCKET TESTING INFORMATION Test Method Used: Hydrostatic Vacuum Other Test Equipment Used: Equipment Resolution: Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1234 Bucket Installation Type: Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test: Test Start Time (TI): Initial Reading (RI): Test End Time (TF): Final Reading (RF): Test Duration (TF –TI): Change in Reading (RF -RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Comments –(include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician’s Signature:________________________________________________ Date:_________________________ 1 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. Express Gas 11/27/2019 928 Flower Street Bakersfield 93305 Sham Hanish (661) 431-3007 10/29/2019 None present Confidence UST Services, Inc. Aaron Perrigo 804904 8485827 Lake Test 0.0625” T1 Unl T2 Prem 11.00” 11.00” 14.50” 14.50” 5 min 5 min 9:00am 9:00am 14.00” 14.00” 10:00am 10:00am 14.00” 14.00” 1 hr 1 hr 0.00” 0.00” 0.0625” 0.0625” 11/27/2019 ✔✔ ✔ ✔✔ ✔✔