Loading...
HomeMy WebLinkAbout1.8-7317 Ph 3E D 0 z 3 LOT LINE— LOT LINE GSTC STUB 1•_6" MID ) 1' MIN 1 10 RUE }- - - - - T _ R/W MAIN TRENCH N I I � GSTC STUB - - R/W LOT LINE ---I POE — J_ TYPICAL INTERIOR STUB INSTALLATION NO SCALE W PUE K z U PAD -MOUNTED / EQUIPM ENT e $ SUBSURFACE TRENCH ENCLOSURE CENTERLINE TYPICAL INTERIOR STREET NO SCALE NOTE: ALL SERVICES AND SUB -STRUCTURES ARE NOT TO SCALE FOR CLARITY. ALL COMPONENTS SHALL FIT WITHIN THE RUE OR FRANCHISE AREA UNLESS OTHERWISE NOTED. REFER TO DETAILS FOR LOCATIONS. — SUBSTRUCTURE VERIFICATION STAMP DEVELOPER PLEASE NONE AND SIGN ALL P.6& E. ENCLOSURES AND BOXES HAVE BEEN SET TO GRADE ACCORDING TO GRADE STAKES PROVIDED BY DEVELOPERS ENGINEER. ALL CQSTS TO RELOCATE OR RE-AOIUST DU'RES AT A LATER DAZE WILL BE VILLED TO THE DEVELOPER. PLEASE HAVE YOUR JOB SUP. VERIFY THE CORRECTED GRADE OF ALL ENCLOSURES AND BOXES. AND SIGN AND DATE DRAWING. THANK YOU SIGNED — DATE 24' WIDE (COMMON) FINISH GRADE 30' MINIMUM IN FRANCHISE MEA 30' MINIMUM IN FRANCHISE AREA ( OWER TTELED MIN 2" OR e T T �_ POSSIBLE 50' TOP OF GDS LEVEL 3" MIN 12' MIN. MIN BOTTOM OF d" TELEPHONE OR TV �' SSB S P P OR 6" 2' or a SHADING 1) 2" SAND SHADING AROUND GAS & ELECTRIC IF SOIL IS NOT ROCK FREE 2) ONLY PARTIES PMTICIRAHNG IN U.SA ARE ALLOWED IN JOINT TRENCH 3) ANY PARTY EYCEEDINO RS TRENCH ALLOTMENT SHALL MAKE ARRANGEMENTS TO ENSURE THAT TRENCH WILL ACCOMMODATE ADDED FACILITIES 4) CA, TO GO ON SIDE OF TRENCH NEAREST STREET 5 TRENCH LAYOUT SHAD. CONFORM TO UO %MGM 55453. TYPICAL DISTRIBUTION TRENCH NO SCALE 5 SUBSURFACE ENCLOSURE 4 24' 3 0 WALL 4' 3' MIN. PAD -MOUNTED EQUIPMENT TRENCH CENTERLINE STOCKDALE RANCH Na SCAUE MINIMUM 18" MINIMUM a e JOINT TRENCH RECAP TRENCH OCCUPANTS DISTRIBUTION OR SERVICE TRENCH SIZE DEPTH FOOTAGE BACKFILL SURFACE GSTCDIST a 24" x 59" 245' SPREAD DIRT GPTC DIST 24" x 59" 1,780' SPREAD DIRT GESTIC DIST 24" x 59" 1,644' SPREAD DIRT GTC DIST 24" x 59" 115' SPREAD DIRT L a"s •sa as'rxAi: v x ^ (2PHOL�E�14DU�T' f 2 T `nrne 1 1 GSTC SERV FRANC 18" x 46 681' SPREAD DIRT GSTC SERV PRIVATE 18" x 46" 330' SPREAD DIRT STC SERV PRIVATE 18" x 46" 0' SPREAD DIRT G SERV PRIVATE 18" x 46" 9' SPREAD DIRT GSTC SERVICE COMP. 18" x 46" 350' SPREAD DIRT Utility Standard 55453 "Joint Tread,' Uihib't B, is updated per this building as follows: MINIMUM SEPARATION AND CLEARANCE REQUIREMENTS (Inches) FIELD 3`yh H yr W 3.,q aG . DUCT qT DBS CN S sa a eS4S T MINIMUM COVER MIN. TELEPHONE (559) 365--8608 C CABLE TV FRANZ / SLASH INDICATES CHANGE IN OCCUPANCY --------- 12 e� (GAS) SEENOTES4 Z &13 �, PROPOSED 12 12 12 6 12 6 24"; 30" IN STREET L a"s •sa as'rxAi: v x ^ (2PHOL�E�14DU�T' f 2 T `nrne 1 1 12 12 12 24"; 30" IN STREET T (reLEPHO IDDIRECTBB 12 1 T 1 12 12 12 24"; 30" IN STREET 4" E STREEBUGHT IS IN TRENCH [c] PROPOSED CABLE SPLICE BOX 3) ONLY PARTIES PARTICIPATING IN USA ME PROPOSED PAD MOUNTED TRANSFORMER 72 1 1 72 12 12 24"; 30" IN STREET 2'1- m BIG. 2 ,CO 5, IN sa v,4 ^ekwnx, (ELEC 7IIC5COND3ARYV) 6 12 12 12 1.5 3 1.524"; 30" IN STREET P)= (ELECTRIC PRjMAR1Q 12 12 12 12 3 3 3 36"; 36" IN STREET � H SL: STREETLIGHT) '� - `�4'>- 6 12 12 12 1.5 3+5 24 ; 30" IN STREET �Xl SEE NOTE ice,•* xs " F,G*f (FOREIGN,ELECTRIC g'w, ' 12 12-* 12°- 12" 12 24"; 30" IN STREET _i"k`'.. SOUCvES (NQ#1 ¢G&E*) a` SEE NOTE 5 saT"3A _ -Must be considered a 'Utility' as defined in MIN Standard 55453 'Join[ Trench.' Notes 4, 5, 7, and 13 ore located in Iflift Standard 55453 Exhibit0, '—Joiat EnCiElt ragBi ons and Ncuooney Guide." -Tor exceptions, refer to GO 125 Me Sedan B Items (11 and (2), GAS NOTE: i TRENCH DEPTH NOT TO EXCEED 5' UNLESS APPROVED BY PG&E INISPECTOR. IN NO CASE 24" SHOULD PLASTIC GAS PIPE BE INSTALLED AT A (30" IN DEPTH GREATER THAN 10' UNLESS APPROVED STREET) BY PG&E SENIOR GAS ENGINEER. 42 FIELD +" G GAS P 1U® COMPANY S ELECTRIC SECONDARY MIN. TELEPHONE (559) 365--8608 C CABLE TV FRANZ / SLASH INDICATES CHANGE IN OCCUPANCY --------- 12 SERVICE TRENCH ® — — PROPOSED MAIN LINE TRENCH 6" — — — -- 1) 2" SAND SHADING MOUND CAS & ELECTRIC PROPOSED #2 (17" x 30" x 18") ELECTRIC SPLICE BOX E2E] MIN. #2E (17" x 30" x 26") ELECTRIC SPLICE BOX E3] PROPOSED IF NATIVE SOIL IS NOT ROCK FREE ES] PROPOSED O #6 (4' x 6'-6" x v) SUB -SURFACE ENCLOSURE E7] PROPOSED #7 (4'-6' x 8'-6" x 6') SUB -SURFACE ENCLOSURE 2) SEE OTHER DERAIL IF NON—PG&E d S G TELEPHONE PEDESTAL\SPLICE BOX 4" E STREEBUGHT IS IN TRENCH [c] PROPOSED CABLE SPLICE BOX 3) ONLY PARTIES PARTICIPATING IN USA ME PROPOSED PAD MOUNTED TRANSFORMER BEDDING MATERIAL71 ALLOWED IN THIS TRENCH E-'+ -< Q 2'1- m BIG. 2 (VIEW FACING OISTRJBURON TRENCH) TYPICAL SERVICE TRENCH NO SCALE NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL DRAWINGS FOR ELECTRIC FACILITY PLACEMENT, DETAILS, AND CLEARANCES. 9 10 GENERAL NOTES: 1. DEVELOPER TO DO ALL TRENCHING, SHADING, AND BACKFILLING. PER UO STANDARD 5-5453. 2. PHONE AND CABLE TV FACILITIES ARE SUBJECT TO CHANGE AT THE DISCRETION OF THOSE COMPANIES. 3. PADS, BOXES AND OTHER FACIUTES ARE NOT SHOWN TO SCALE. 4. GAS AND ELECTRIC FACILITIES WILL REQUIRE SAND SHADING IF NATIVE SOIL IS NOT ROCK—MEE. PG&E WILL INSPECT BACKFILL MATERIAL. TEL AND/OR CATV MAY ALSO REQUIRE 12" OF SAND BACKFILL. S. GROUND TO BE WITHIN .2 FT OF FINISH GRADE PRIOR TO TRENCHING. 6. GAS AND ELECTRIC FACILITES REQUIRE AT LEAST 3' OF SEPARATION (1' UNDISTURBED SOIL) FROM PARALLEL RUNS OF WATER, SEWER, OR STORM DRAIN. 7. PRE—CONSTRUCTION MEETING REQUIRED TWO WEEKS PRIOR TO THE START OF INSTALLATION. B. CALL U.S.A. AT LEAST 48 HOURS PRIOR TO TRENCHING (DIAL 811) 9. PG&E WILL ASSIST IN LOCATING ENDS OF EXISTING GAS MAINS. 10. DEVELOPER IS RESPONSIBLE FOR OBTAINING ENCROACHMENT PERMITS.. 11. STREETLIGHT LOCATIONS MAY HAVE CHANGED. REFER TO THE APPROVED STREETUGHT IMPROVEMENT PLAN FOR STREETLIGHT INSTALLATION. 12. DEVELOPER SHALL CONTACT ALL INVOLVED PARTIES PRIOR TO MAKING ANY CHANGES FROM THIS DRAWING. 13. REFER TO EACH PARTY'S INSTALLATION INSTRUCTIONS FOR MORE PRECISE DESCRIPTION OF SUB57RUCTURES AND OTHER REQUIREMENTS. LEGEND: FIELD CHANGES G GAS P ELECLRIC PRIMARY COMPANY S ELECTRIC SECONDARY T TELEPHONE (559) 365--8608 C CABLE TV FRANZ / SLASH INDICATES CHANGE IN OCCUPANCY --------- PROPOSED SERVICE TRENCH ® — — PROPOSED MAIN LINE TRENCH EXISTING UNDERGROUND FACILITY — — — -- EXISTING ROW / PROPERTY LINE E2] PROPOSED #2 (17" x 30" x 18") ELECTRIC SPLICE BOX E2E] PROPOSED #2E (17" x 30" x 26") ELECTRIC SPLICE BOX E3] PROPOSED #3 (24" x 36" x 18") ELECTRIC SPLICE BOX ES] PROPOSED O #6 (4' x 6'-6" x v) SUB -SURFACE ENCLOSURE E7] PROPOSED #7 (4'-6' x 8'-6" x 6') SUB -SURFACE ENCLOSURE O (n d PROPOSED TELEPHONE PEDESTAL\SPLICE BOX [T] E [c] PROPOSED CABLE SPLICE BOX �J PROPOSED PAD MOUNTED TRANSFORMER INDICATES TRENCH FOOTAGE & OCCUPANCY 1D' PROPOSED LS 2A STREET LIGHT LOCATION (SEE NOTE 11) --� PROPOSED SERVICE LOCATION FOR TRENCH INSPECTION CALL (559) 263-7312 ANY CHANGES TO THIS DESIGN MUST JOINT TRENCH COMPOSITE APPROVED BY, FIRST BE APPROVED BY PG&E. GAS ADE: GAS ADE — ELECT ADE., PHONE.' — DATE__ ALL FIELD CHANGES REQUIRE PRIOR APPROVAL FROM: COMPANY TELEPHONE 1. LEMURI FLORES P G & E (559) 365--8608 2. BRIAN FRANZ ATT (661) 631-3492 3. GREG EOE BRIGHTHOUSE (661) 395-3351 o n P L_ TDcuoALAF _. wGxwnv - I y TRACT FL S I e J NORTH HALF OF .. SECTION l NORTH HAI F OF - JDo. R.%5E. SECT (.N J E. L PROJECTSITE KENN CQUNrr TeATER ASLHCY NTS VICINI7Y MAP 5 4 (n U z 0 W WELL moi' IE- 00 !n Ln O r d 00 OCD O U0 U U0 GO 2 f— !L f� CO U n O 1H V 0 I Z W I iw 32CD 3 2 LD ED U 0 d w" CD ti C� 7. cl� B CIE W Z Z C__) Gs7 W lY ED Cn i G QH- F- F7 In U H— O t CD LO C) J Z O (n d U n O 1H V 0 I Z W I iw 32CD 3 2 LD ED U 0 d w" 1 INCH 0 CD cl� B CIE W Z Z Gs7 W lY ED Cn In G QH- In U H— .may Q 0CIQ C) J rl- > W Ln = E C/n d W W E-'+ -< Q ED m Y U O I— Cn 1 INCH 0 1 2 3 4 5 6 7 8 9 10 � W W Q' W CIDF— 1� C9 O E �- U o U o Z U cn w ,4 ;j STUB FOR 27 FUTURE 4 GTC 115' .�2'c�/ 26 E-+ Go w I .°'' ^�-, GSTC 76' `4 25 MAT F- o a PST 7s' hTy / 24 \ �H 01VE aHT El �n Z' C�CID PUE \I \ �'.T,�� IN Fid, GP6C / 23 �'�� / ? a p n o rp 22 T-k`J w ■ Tr o PUE ,$ 6 .-:\ -e ._\. PUE R y / 21 .�.� �4 `\ ti� \ a PST A g> 160' pF SeR�C ` O �,. / 70' - PHAS CSr' 'moi -rLC� 193x%/ 2® �~ ,, .�.._, -JS. \ .�__.� o / 19 `'�� __. \ GPTC 18 Iii 6' I!�I j z� E rn p PUE i T \ SERVICE ��{{��.a6 o> / -�` y' PUE 29..., _ �:A �, :�,, ~\"�`:: . L_ ow 1 �`c� _ 3' �s� ,h 2W !� q ,``"�� i PST 1t� 130' '_oo ' �6'p ,Y� ®S ---%"�.1�,Try C� OR `` RG T STC 1 f lh �+o I I IEXIST.)� 20 PHASE �1 Z m \y/ 10' y % U sERVCE � — `\\!-~ /� (EXISTING) 7,3v 17 �J I o Lij ¢ ¢ a ¢ w v STUB FOR GPTC 5' ` / ,_ i _ _ _ / �,i_ car 70' DT - FUTURE SERVICE p�kr wr 30 "S �W 6' , - 1 PUE u F lye — _--- RE PHASE / __-------.__ 31 / /fir _ G TIE IN TO —� r� --- ' _ d ' � o / zs _ _ 2 32 �,;- __ T 'PTC I r EXISTGA E — c3 J T F NiA60' ORD ST. o C / / I ss' h g' J PUE / 33 !� I TIE INTO — — so' ROW) �.. it yyy 4' -�- EXISTING o o I -- JT STUBEi / 47 to' PUE h III1 PHASE ' / I Elf !' t SHORT SIDEE SERVICE d9 4'� ��� ZRAC7 7317 (EXI$T1�d�C) 48 DWY — -liI �J DWY -444 — 4 47 37 TIE INTO EXISTING JT I t z 36 alo s' 48 I PUE cPTO 60' �� r� ce _zr. I� I- / 83c 93 I 35 �� — _ I 34 II — — — —� �"� �- 54 46 I �s 10' — — !2 0 )E - 36_�PUE� �� y, r m PUE Dom— vmiol I lo, _ �' 45 14* 14' SHORT 2E SIDE SERNCE58 'i j! / /' LONG ! SIDE SERVICE DW —DWY I — I w g I - sr�< sy BA COU RT I �S�RhCE PST 90 _ PUE -- s3 4J z ,. (52 ROW I 1 SWEEP - - TRENCH — "T -- mei 'PST, Cr GPTC 1�5 \ �F�o �� i 39 �y / 66 PST 44 I 13,y I�� I 338 \ \�T I GSTC °p¢/ 84 A, I I � c � z Z /TRSWEEP \ �'o�,' I S2 d O I 40 I 41 I`V 42 43 °s I ENCH \O4 U2 ® a crn Q n oz o _t U r 313 I .a 51 CID A I L) C , = v n L a E`er-+ ¢ Q om O SCALE: 1 "=50' � z cn NOTE: ALL SERVICES AND SUB -STRUCTURES ARE NOT TO SCALE FOR CLARITY.J ALL COMPONENTS SHALL FIT WITHIN THE PUE OR FRANCHISE AREA UNLESS NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL W NOTED. REFER TO DETAILS FOR LOCATIONS. DRAWINGS FOR MAJOR ELECTRIC FACILITY PLACEMENT, DETAILS, AND CLEARANCES. 50' a' 50' ioo' DIAL 111—jOTHERWISE o 6 5 4 3 2 1 INCH 0 1.8-7317 Ph 3 1 2 3 4 5 6 I 7 8 9 10 I j w w w M M � n STUBFOR I d FUTURE m v�� H z w v GPTC A 759' \ �'....... o P4 a O STUB 5' PAST d IMPROVEMENTS FOR FUTURE PHASE 5 +' co �. 61 I v - R� \ (so° Rows Cy �RJ►g a� �m c) Lij STUB FOR FUTURE117 ¢� FUTURE '---- "-- GPTC GPTC SERVICE�W / �`�`----.-.._`'�-yam — ROPE TRENCH V BEHIND CBJJ PSTT - 4 5 IE INTOolo - -- - JT 4' r -- wo 4 J aGPTC /s 33 ' ' IM�EXISTING O Q \ 1D' /o�� / - ���' -7•. 1--._- RUE 6' '6' PST I _ _ �60N �P/_Rj� �`_l� r r�C 230' y mwl �Cr•7 TIE INTO , 6 ' EXISTING JT� � (EXIST.) I��'��iASE 1 1 L F a an /mss -�_� ♦ f ' `1r \ / ..iOLj / RO) J r - GPTC 57' wog _ RUE 10 J F ` �e - -- 41T o / 1213 - /\ l l lam 1 5' I /o 14 eo MIA ;nL T N ,� Izs� o� v PUE olo iSI ®�� I CT 731q PMA 1 9 I o o of SII z U �!� - � � o J ca EXIST.) �'� - —r-� - - - r- r w Lo ACD H Q M Y m �y OCD SCALE: 1 "=50' NOTE: ALL SERVICES AND SUB -STRUCTURES ARE NOT TO SCALE FOP. CLARITY. ALL COMPONENTS SHALL FIT WITHIN THE PUE OR FRANCHISE AREA UNLESS NOTE: USE THIS DRAWING FOR STAKING TRENCHES ONLY. REFER TO APPROVED ELECTRICAL - (yy w 1 ? OTHERWISE NOTED. REFER TO DETAILS FOR LOCATIONS. DRAWINGS FOR MAJOR ELECTRIC FACILITY PLACEMENT, DETAILS, AND CLEARANCES. 50' o' 50' too' E-4 DIAL 611 0 6 5 4 3 2 1 INCH 0 1.8-7317 Ph 3