Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Mikuls UST Correspondence
ENVIRONMENTAL HEALTH DIVISION¶4 CERTIFIED UNIFIED PROGRAM AGENCY (CUPA) m KERN COUNTY MATTHEW CONSTANTINE m Public Health Services director L DEPARTMENT 2700 M STREET, SUITE 300 BAKERSFIELD, CALIFORNIA 93301-2370 VOICE: 661-862-8740 FAX: 661-862-8701 WWW.CO.KERN.CA.US/EH March 03, 2014 ALAN MIKULS 2310 TAFT HWY BAKERSFIELD, CA 93313 Annual UST Monitoring System Compliance Inspection Facility: MIKULS TRUCK TERMINAL,FA0000182 2201 TAFT HWY BAKERSFIELD California state law requires that all underground storage tank (UST) leak monitoring equipment be calibrated, operated and maintained in accordance with manufacturer's instructions, and certified every 12 months ror proper operability and calibration. All UST facilities require the following annual inspections: I. Annual Monitoring Certification of the underground storage tank system - performed by a certified technician employed by a licensed contractor on behalf of the UST owner/operator. 2. Annual Routine UST Inspection - performed by the Kern County Environmental Health Services Department (KCEHSD). Based on this department's records, the aimual monitoring certification was last completed on 03/07/2013. KCEHSD must be notified at least 48 hours prior to testing.Please have your certified contractor schedule the monitor certification with this department. We will make every effort to complete our routine inspection at the same time. During the inspection, the following documents must be available for review: Facility and Tank Registration Forms Monitoring Procedure Plan Site PlotPlan Financial Responsibility Forms Emergency Response Plan Monitoring records The monitor certification is to be scheduled by 04/02/2014 to avoid future enforcement action. Please contact the undersigned at (661) 862-8755 for further information and/or to schedule the inspection. Sincerely, AJ M- GABRIEL RUBIO WASTE MANAGEMENT TECHNICIAN II Unified Hazardous Materials/Waste Program , m Billable KERN COUNTY CONSTRUCTION, INC.m Factory War-r. LICENSE NO. 481053 m Maintenance P.O. Box 6096 · Bakersfield, CA 93386-6096 m Mot Billable (661) 634-9950 · Fax (661) 634-9233 lj Bid Jab Name. 4Z7J ZEci -~#10456 =S'S: 2 Qol mirl H~y Date:j-R>"/y City:£, AA-.Cklj nu Zip:Phone,Work Order# Dispenser Make:Cijst. Order# Dispenser Model:Close Confir. # Dispenser Serial #:Parts Order# Pump Test: Gallons:Dollar Amt: Description of Work Performed , a' '"7 ·"=/o/t H D?" DATE COMPLETE 3"a2SY'V 'e:UA e-- :" =4"jDate jVS""Yc" Unless otherwise providing by law, the seller hereby expressly disclaims dl warranties, either expressed or impli , incbding any implied warranty of merchantability or fitness for a particdar purpose, and neither assumes nor amhorizes any other person to assijme forit any liability in connection with the sale of said prochcfs. A finance charge of 1)4% per month (18% peryear) willbe added to past dUe accoljhts. Qty Part No.lnv.Description & SIN Each Amount Loc # .Worker Date Depart Arrive Depart Stop O/Tsya(©/"r ,3"2t-/y S-ba e.'7t /b.'l'<k t?Z'Total Labor Total Parts Mileage Sublet Sales Tax Total Amount m Billable KERN COUNTY CONSTRUCTION, INC.m Factory War-r. LICENSE NO. 481053 m Maintenance P.O. Box 6096 · Bakersfield, CA 93386-6096 m Mot Billable (661) 634-9950 · Fax (661) 634-9233 lj Bid Jab Name. 4Z7J ZEci -~#10456 =S'S: 2 Qol mirl H~y Date:j-R>"/y City:£, AA-.Cklj nu Zip:Phone,Work Order# Dispenser Make:Cijst. Order# Dispenser Model:Close Confir. # Dispenser Serial #:Parts Order# Pump Test: Gallons:Dollar Amt: Description of Work Performed , a' '"7 ·"=/o/t H D?" DATE COMPLETE 3"a2SY'V 'e:UA e-- :" =4"jDate jVS""Yc" Unless otherwise providing by law, the seller hereby expressly disclaims dl warranties, either expressed or impli , incbding any implied warranty of merchantability or fitness for a particdar purpose, and neither assumes nor amhorizes any other person to assijme forit any liability in connection with the sale of said prochcfs. A finance charge of 1)4% per month (18% peryear) willbe added to past dUe accoljhts. Qty Part No.lnv.Description & SIN Each Amount Loc # .Worker Date Depart Arrive Depart Stop O/Tsya(©/"r ,3"2t-/y S-ba e.'7t /b.'l'<k t?Z'Total Labor Total Parts Mileage Sublet Sales Tax Total Amount ¶m m KERN COUNTY m Public Health Services L — DEPARTMENT 2700 M STREET, SUITE 300 BAKERSFIELD, CALIFORNIA 93301-2370 MATTHEW CONSTANTINE DIRECTOR VOICE: 661-862-8740 FAX:661-862-8701 \N\N\N.CO.KERN.CA.US/EH June 15,2015 Mr. Alan Mikuls Mikuls Truck Terminal 2201 Taft Highway Bakersfield, CA 93313 Facility ID: FA0000182 Re:Mikuls Truck Terminal, 2201 Taft Highway, Bakersfield, CA 93313 NOTICE OF VIOLATION AND ORDER TO CORRECT Dear Mr. Mikuls: This Notice of Violation and Order to Correct is in response to the Certified Unified Program Agency (CUPA) Underground Storage Tank (UST) inspection conducted on March 21, 2014 at the facility located at 2201 Taft Highway, Bakersfield, CA. Violations of Title 23 of the California Code of Regulations (CCR) are detailed in the following section: VIOLATIONS l. The Respondent is in violation of the California Code of Regulations (CCR) § 2638 (a) for failure to complete the Monitoring Certification every twelve (12) months. The facility is scheduled to complete the Monitoring Certification annually every February. The Monitoring Certification was conducted last year on March 21, 2014, a few weeks past due. Currently the facility is four (4) month past due for 2015. California Code of Regulations (CCR) § 2638 (a): (a) All monitoring equipment used to satisfy the requirements of this article shall be installed, calibrated, operated and maintained in accordance with manufacturer's instructions, and certified every 12 months for operability, proper operating condition, and proper calibration. Written records shall be maintained as required in section 2712. 2. The Respondent is in violation of California Code of Regulations (CCR) § 2638 (d) for failure to submit completed Monitoring System Certification results to this agency within thirty (30) days. The monitoring certification was conducted on March 21, 2014. During the test, the direct bury Diesel spill bucket failed. The owner obtained an Underground Storage Tank (UST) Modification Permit to replace the spill bucket. The new spill bucket was installed and re-tested by a licensed and certified third party testing company on July 18, 2014. The operator has failed to submit passing re-test results to this department. California Code of Regulations (CCR) § 2638 (d): (d) UST owners and operators shall submit a completed "Monitoring System Certi/ication " form to the local agency within 30 days a/ier completion ofthe inspection. 3. The Respondent is in violation of California Code of Regulations (CCR) § 2637 (e) for failure to submit completed secondary containment test results to this agency within thirty (30) days. The secondary containment test was conducted on June 26, 2014. During the test, the piping penetrations failed in Under Dispenser Containment (UDC) 1/2. The owner obtained an Underground Storage Tank (UST) Modification Permit to replace the failed piping penetration test boots. The UDC was repaired and re-tested by a licensed and certified third party testing company. The operator has failed to submit passing test results to this department. California Code of Regulations (CCR) § 2637 (e): (e) Underground storage tank owners and operators shall submit a copy of the test report to the local agency within 30 days of the completion ofthe test. CORRECTIVE ACTIONS The following corrective action shall be completed: ·IMMEDIATELY schedule the Monitoring Certification with a certified International Code Council (ICC) technician and notify the Kern County Public Health Department, Environmental Health Division of the date and time of the testing. ·Within five (5) days of receipt of this notice, submit to the Kern County Public Health Department, Environmental Health Division a completed copy of the Monitoring System Certification and Secondary Containment testing results. The issuance of this Notice of Violation and Order to Correct does not preclude the Kern County Public Health Services Department, Environmental Health Division, from taking administrative, civil or criminal action as a result of the violations noted herein. Please call me at (661) 862-8755 if you have any questions. Sincerely, Gabriel Rubio Waste Management Technician II Unified Hazardous Materials/Waste Program CC: File ¶m ¶ 6'u'Glfa'e'aith Services L DEPARTMENT 2700 M STREET, SUITE 300 BAKERSFIELD, CALIFORNIA 93301-2370 MATTHEW CONSTANTINE DIRECTOR VOICE: 661-862-8740 FAX:661-862-8701 \N\NWCO KERN.CA.US/EH PERMIT TO CONSTRUCT or MODIFY UNDERGROUND STORAGE FACILITY FACILITY ID: FA0000182 [J NEW CONSTRUCTION X MODIFICATION FACILITY NAME/ADDRESS OWNER(S) NAME/ADDRESS "CONTRACTOR NAME/ADDRESS Mikuls Truck Terminal Alan Mikuls Kern Construction, Inc. 2201 Taft Highway 2310 Taft Highway josh Simmons Bakersfield, CA Bakersfield, CA 933 13 P,O. Box 6096 (661) 832-5390 Bakersfield, CA 93386 License # 481053 A, HAZ Phone No. (661) 809-2052 Phone No. (661) 634-9950 DATE ISSUED: June 20, 2014 EXPIRES ON: September 20, 2014 appAove!?By'= :ubio POSTONPREMISES CONDITIONS: 1.This Modification Permit will cover the replacement of existing diesel spill bucket with a new OPW 2 100 EVR Series spill bucket. 2.This Modification Permit will also cover the replacement of two (2) existing penetrations in UDC 1/2 with two (2) new Bravo UDC penetration boots. 3.All construction to be as per facility plans approved by this department and verified by inspection by Permitting Authority. 4.All equipment and materials in this construction must be installed in accordance with all manufacturers' specifications. 5.Permittee must contact Permitting Authority for on-site inspection(s) with 48-hour advance notice. 6.Backfill material for piping and tanks to be as per manufacturers' specifications. 7.Construction inspection record card is included with permit given to Permittee. This card must be posted at job site prior to initial inspection. Permittee must contact Permitting Authority and arrange for each group of required inspections numbered as per instructions on card. Generally, inspections will be made of: a.Piping system with secondary containmentb.Sump and UDC Test c.Line Tightness Test d.Overfill protection and leak detection/monitoring e.Any other inspection deemed necessary by Permitting Authority. 8.Primary and secondary containment of both tank(s) and underground piping must not be subject to physical or chemical deterioration due to the substance(s) stored in them. Documentation from tank, piping, and seal manufacturers of compatibility with these substance(s) must be submitted to Permitting Authority prior to construction. 9.All new construction must meet the requirements to be "product tight" (impervious to the liquid and vapor of the stored product) and have a continuous monitoring system as specified in California Health and Safety code, Chapter 6.7, Section 25290.1. ACCEPTED BY:DATE:June 20, 2014 KERN COUNTY ENVIRONMENTAL HEALTH SERVICES DEPARTMENT HAZARDOUS MATERIALS PROGRAM INSPECTION RECORD POST CARD AT JOBSITE 2700 "M" STREET, SUITE 300 BAKERSFIELD, CA 93301 (661) 862-8700 PERMIT #:FA0000182 OWNER:Alan Mikuls FACILITY:Mikuls Truck Terminal CONTACT:Josh Simmons ADDRESS:2201 Taft Highway ADDRESS:P.O. Box 6096 CITY:Bakersfield, CA 93313 CITY:Bakersfield, CA 93386 PHONE #:(661) 832-5390 PHONE #:(661) 634-9950 INSTRUCTIONS: Please call for an inspection or submit the requested information when ready. They will run in consecutive order beginning with number l. DO NOT cover work for any numbered group or continue with the next phase of work until all items in that group are signed offby the Permitting Authority. Following these instructions will reduce the number of required inspection visits and therefore the assessment of additional fees. INSPECTION DATE INSPECTOR - TANKS & BACKFILL- l Backfill of tanks N/A I Copy of installation check list N/A 1 Spark Test Certificate N/A - PIPING SYSTEM - l Primary piping, vapor, and vent lines pressure/soap test N/A 2 Corrosion protection of piping & fill pipe N/A - SECONDARY CONTAINMENT - 2 Secondary piping, vapor and vent lines pressure/soap test N/A 2 Sumpand UDC test '7/h/l'4 Apj-j ^ 2 Electrical Conduits N/A Please contact the Fire Departmentat (661) 391-7082 and Building (electrical) Department at (661) 862-8661 to schedule final inspections with them before calling this department for the final inspection. 330CKVR 3 Overspill boxesl Drop tube valves "7 IB/H jaFp1L1t ~ 3 Line Leak Detectors and Positive Shut Down N/A 3 Electrical Seal Offs and Sealed Field Connections N/A 3 Monitor System Check N/A 3 Enhanced Leak Detection N/A 3 As-built drawings (if required)N/A 3 Monitoring Requirements "//$/L'f AAJ UL, 3 Submittal of owner information and Form C "7// S /tq :Lu fLLa CONTRACTOR CONTACT Kern Construction, Inc, josh Simmons LICENSE #481053 A, HAZ PHONE #(661) 634-9950 UNDERGROUND STORAGE TANKS NEW CONSTRUCTION/MODIFICATION APPLICATION KERN COUNTY ENVIRONMENTAL HEALTH SERVICES DIVISION 2700 M STREET, SUITE 300 BAKERSFIELD, CA 93301 (661) 862-8740 Fax (661) 862-8701 |°" Pll' r'""!Pujj'"f TYPE OF ACTION I. NEW SITE CONSTRUCTION N.MODIFICATION I r NEW TANK INSTALLATION AT EXISTING FACILITY ^ (Check owe item only) I.FACILITY /SITE INFORMATION FACILITY ID#l 5 W 0 l 0 0 0 'USl' FILE NUMBER B .lBUSINESS NAME (same ag FACILITY NAME or DBA - Doing Busincss As) MJwI" F"a-s^1" BUSINESS SITE ADORE. S '°'""m jcj'4 lj-j. '" ?o&eXle|d '" "Q4'E!"?!!Sqo '°' '"u=j'""a'li'"'°' ll. CONTRACTOR INFORMATION contjactor name c contractor phone d hem Loc-(^j-l Ca b-5 ( ^^lj Lu ^ <E~c- .G 61 - a"t - ¶qs1> tmailing or street addr4ss e 77O.i3·Uj^Dq6 "2&,<. ,73 C,: Q ' '?"A " '""%73¶G " jCALIFORNIA contrators license number i LICENSE type L4%l o<"3 -(click for drop-down) CERTIFIED installer k icc installer certification number l,Joc K Sj'r^~g CuS 5"z-"jz"3 CT III. SCOPE OF WORK briefly describe the proposed scope OF work:m "C /' I' -[b-,0$ L—SK: l'D(^.cL0P gj /n~"oPUD 'LIUl)=VIZ &^C3 <fi'k " "' """^ :4L4l", IV. TANK LIST ' tank number product(s)capacity (add adchtional on separate shect) V. INTERGRITY TESTING/ENHANCED LEAK DETECTION testing company o phone ' test method q VII. APPLICANT SIGNATURE C'cmficmion Z,fmiry tmt the information provided herein is tme and accurate (o the best ofmy knowled8e SIGNATLRFX)F applicant date 424 PHONE "' G- lZ--lf G6/-L 3¢/ -¶q%"tj 427naUf APPLICANT (print)426 TITLE OF applicant , )q}C- Si n^~ur3 C66j n~j bj FA-izz OPERATING PERMIT APPLICATION - TANK INFORMATION (One form per UST) kern county environmental health SERVICES division Unified Program Consolidated Form (UPCF) 2700 m street, suite 300 underground storage tanks bakersfield, ca 93301 (661) 862-8740 Fax (661) 862-8701 (on' rr' r' mk)PApe of TYPE OF ACTION (Check one item only. For an UST permanent closure or removal, complete only this section and Sections I, II, III, IV, and IX below)430 El l. new permit CI 3. renewal permit [j 5 change of information [j 6. temporary ust closure Cl 7. ust permanent closure on site El 8. ust removal date ust permanently closed:430a date existing ust discovered:"" i. facility information IFACILITY ID # (Agency Use Only) — 3BUSINESS NAME (Same as FACILITY NAME or DBA-Doing Business As) mikuls truck terminal business site address m city '°' 2310 taft highway bakersfield il tank description tank id #432 tank manufacturer 433 tank configuration: this tank is 434 @ 1. a stand-alone tankmodernCJ 2. a compartmented unitl date ust system installed "'tank capacity in gallons "'number of compartments in the unit "' 1998 20,000 1 iii. tank use and contents tank [jse ® la motor vehicle fueling d lb, marina fueling Cl lc. aviation fueling 439 CI 3. CHEMICAL PRODUCT STORAGE Cl 4. HAZARDOUS WASTE (Includes Used Oil)[J 5. EMERGENCY GENERATOR FUEL [HSC §25281 5(C)] Cl 6. OTER GENERATOR FUEL Cl 95. UNKNOWN Cl 99, OTHER (Specify):439a contents petroleum:[j la, regular unleaded [j lc. midgrade unleaded Cl lb premium unleaded 440 i® 3. diesel ci 5 jet fuel Cl 6. aviation gas [j 8 PETROLEUM BLEND FUEL C] 9 OTHER PETROLEUM (Sp'cify)'440a non-petroleum: El 7 used oil El lO. ethanol [j i] other non-petroleum (sp'"fy)'440b iv. tank construction type of tank r l. single wall @ 2 double wall c 95 unknown 443 primary containment m l steel Cl 3 fiberglass [j 6 internal bladder 444 [J 7. STEEL + INTERNAL LINING Cl 95 UNKNOWN Cl 99. OTHER (Spccify):444a secondary containment d i. stffl ® 3 fiberglass ci 6. exterior membrane liner Cl 7. jacketed 445 Cl 90 none c] 95. unknown Cl 99. other (Spcc'fy):445a overfill prevention O l. audible & visual alarms D 2 ball float E 3 fill tube shut-off valve 45? d 4 tank meets requirements for exemption from overfill prevention equipment v. product /waste piping construction piping construction r 1. single-walled ® 2. double-walled e 99. other 460 system type ® l. pressure f 2. gravity r 3. conventional suction z 4. safe suction (23 ccr §26.|6(8)(3)1 458 primary containment Cl l. steel ® 4. fiberglass [j 8 flexible [j lO. rigid plastic 464 Cl 90. none ci 95. unknown [j 99 oTHER(srcify):464a secondary containment [j l steel @ 4 fiberglass d 8 flexible ci lO. rigid plastic 464b [j 90. none El 95 unknown d 99 OTHER(Specify):464¢ piping/turbine containment sump type z l. single wall 7 2. double wall z 90. none 464d vi. vent, vapor recovery (vr) and riser/ fill pipe piping construction VENT PRIMARY CONTAINMENT [J l. STEEL El 4 FIBERGLASS [J ]0 RIGID PLASTIC El 90. NONE Cl 99. OTHER (Specify)464e 464el VENT SECONDARY CONTAINMENT [j I. STEEL Cl 4. FIBERGLASS Cl lO. RIGID PLASTIC Cl 90. NONE Cl 99 OTHER (Specify)464f 464f1 yr primary containment [j 1 steel [j 4 fiberglass [j lO. rigid plastic [j 90. none d 99 OTHER(Specify)464g 464&1 YR SECONDARY CONTAINMENT tj I. STEEL tj 4. FIBERGLASS [j lO. RIGID PLASTIC [j 90. NONE tj 99. OTHER (Specify)464h 464hl vent piping transition sump type r: i. single wall z 2. double wall z 90, none 4641 RISER PRIMARY CONTAINMENT ® l. STEEL [j 4. FIBERGLASS CI lO. RIGID PLASTIC Cl 90.NONE [J 99. OTHER (Specify)464j 464jl 464kriser secondary containment tj i. steel lj 4 fiberglass [j lO- rigid plastic [j 90 none Cl 99 OTHER(Spccify)464kl fill components installed ® l. spill bucket z 3. striker plate/bottom protector z 4. containment sump 45la-c vii. under dispenser containment (udc) construction type ® 1 single wall [j 2. double wall [j 3 nodispensers [j 90 none 469a construction material :j 1 steel ® 4. fiberglass r jo. rigid plastic f 99. OTHER(Specify)469b-c viii. corrosion protection steel component protection Cl 2 sacrificial anode(s)ci 4 impressed current [j 6 isolation 448 ix. applicant signature CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true, accurate, and in full compliance with ml requirements. applicant signature ti2Cw~ ~=date "° 06/13/2014 472APPLICANT NAME (print)"'APPLICANT TITLE a'an m'ku"'/qLRN/ Mi 'KuL ·"owner (09/2013 revised)Form B - Page l of 2 KC Form B UNDERGROUND STORAGE TANK SYSTEM [J NEW CONSTRUCTION -OR- El MODIFICATION EQUIPMENT DESCRIPTION CHECKLIST (Complete all applicable sections) 1. TANK CONSTRUCTION 13 Double Wall Fiberglass [J Double Wall Steel with Fiberglass coating [J Double Wall Steel primaryl Fiberglass secondary [J Other Tank Manufacturer: 2. LEAK MONITORING SYSTEM Console Manufacturer:Console Model #: 3. SENSORS Sensors Positive Shut Manufacturer Model # Down Tank Annular Space Sensor ""r Yes No Tank Turbine Sumps Sensor 7Yes Tno Tank Fill Sumps Sensor Yes No Dispenser Pan Sumps Sensor ZYes Zno Sump Annular Space Sensor " Yes No Piping Annular Space Sensor 3Yes Zno Positive Shut Down WI Failsafe for system [JYes CJNo disconnection 4. PIPELINE SYSTEM [J Pressure [J Suction [J Gravity 5. LINE LEAK DETECTOR [J Mechanical Manufacturer:Model #: [J Electronic Manufacturer:Model #: 6. PIPING CONTRUCTION PRODUCT AND VENTNAPOR LINES [J Double Wall Fiberglass CI Double Wall Flex Pipe [J Other: Manufacturer:Model #: 7. AUTOMATIC TANK GAUGE Manufacturer:Model #: R )OVERSPILL cojvTAINER WITH DRAIN VALVE Manufacturer~Model #: ·oEjjm. Equipment Description Checklist - Page l of 2 ·" " r " '""m' M' y y "»www.opwg/obal.com OPW i-2100 Series Thread-On Spill Containers Materials OPW Spill Containment Manholes are designed to prevent spilled product from entering the soil near the fill and vapor return riser connections on underground storage tanks during normal tank filling operation, or in the event of tank overfill. The spill containers catch spillage to help prevent soil contamination and groundwater pdlution, OPW Thread-On Spill Containment Manholes are generally used on new tank or riser pipe installations. Cover: Cast aluminum or cast iron Mounting ring: Cast iron E-coating Bellows: Polyethylene Base: Cast iron E-coating or Duratuff ll Clamps: Stainless steel 'Seak: Nitrite j'""; m Features 0 Easy Installation - reduces job-site time and instdlation costs. OPW Thread-On Spill Containers screw directly onto 4" NPT riser. No external connections to make; adjust the final grade height and support the unit with backfill. 0 Integral Pull-to-Open Drain Valve - allows high-speed drainage of excess product into the tank. Designed with a convenient self-cleaning seal and removable screen for easier component cleaning. qQp Capacity - available in a true 5-gallon capacity as well as 15-gallon capacity. q' Rain-Shedding Cover- available in either cast aluminum or cast iron, this unique design incorporates a seal in the underside of the cover, The seal seats between two dams on the mounting ring to prevent surface water from entering the spill container. 0 Fuel Compatibility - designed to accommodate the fuels of the future, including methanol, ethanol and fuels ,with MTBE additives. 0 Product Identification Tags - available for both the cover and bucket to positively identify the product contained in the UST with standard APl symbols. (See product I.D. tag specification page for more information: page 74.) 0 Heavy-Outy Mounting Ring -the angled ramp design offers superior protection against snow plow and traffic damage, and provides for secure concrete anchoring. 0 Corrugated Bellows - can be adjusted +/- 1 inch for desired grade level. 0 DuratufP ll or Cast Iron Base - composite Duratuff ll material is lightweight, durable, and conductive. A rugged, optional, cast-iron base is also available, 0 Highway 20 Rated (H20) - all OPW spill containers and manholes exceed the requirements of the Highway 20 rating. Listings and r> 'ook 'orthts label for LljlCl 'm authentic OPW EVR Certifications >(1¢ Approved products. C-P F" VV P 60 9393 Princeton-Glendale Road o Hamilton, Ohio USA 45011 o Phone: (800)422-2525 © Fax: (800)421-3297 ©20130pwFtmgm~s , I! www.opwgloba/.com G""'A jMn :A'=— DEVR Models - Fill Port with Drain Valve DumtufT ll Base wIth Drain Valvo M0d0ls Model Gal,Liter Cover lbs.kA t"ijl 1·2100·DEVR ,5 19 Aluminum 40 18 _\\ 1·211µDEVR 15 57 Aluminum 47 2¶ 1C.2115-DEVR 15 57 Cast Iron 60 27 -"?<|&,¶1"7"" Cast Iron Bue wIth Drain Valve Models Model Gal.Lllor Cover lbs,kg 1·2100C·DEVR 5 19 Aluminum 40 18 1C.2100C.DEVR 5 19 Ca3tlron 53 24 1·2115C·DEVR 15 57 Aluminum 47 21 1C-2115C·DEVR 15 57 Cast Iron 60 27 5 do 1-2100-DEVR Series Product Fill SpIll Container PEVR Models - Vapor Port with Plug Duratuff' ll Base with Plug Models Model Gal.Liter Cover lbs. , kg 1.2100.PEVR 5 19 Aluminum 40 18 1C·2100-PEVR 5 19 Cast Iron 53 24 rm :,e3 Cast Iron Base with Plug Models Model Gal,Liter Cover lbs.kg 1-2100C.PEVR 5 19 Aluminum 40 18 1C·2100C·PEVR 5 19 Cast Iron 53 24 opw 1·2100, mauon 16" 41 cm )"':1! '""1I'bz' 'g f -"He'gh' 18"1"" g S e from Riser 47cm g h,e-PIpe To S FliMhed l i· , ,m—i ::":or3lopo)"'""~'"' 14'ht " 36cm OPW i-2115, 15-Gdlon 16" 41 cm . 22M m 'S "" "fk ''"" ->' ! $} 20"/,,n 'V-J'"" E , 22'k"m 56cm ¶ pan# TC400 H15144M H12806M VPN4X7 H15271M H15268M 4" Threaded Nipples for Mating Spill Bucket to Adaptor j {Ii' 1-2100-PEVR Series Vapor Recovery Spill Container 'Subtract 2" from height dimondon for Ca8t Iron Bme Modd8. NOTE: 20%" dlmemlon 18 Might from rker pIpe to flnlsh grade (+1" for slope) Description 4" Torquo Cap 4" NPT Nipple, 4" Length ,. 4" NPT Nipple, 5" Length 4" NPT Nlppl0, r Length 4" NPT Nipple, 8" Length 4" NPT Nipple, 10" Length Replacement Parts Part #Demriptlon 1DK-210OEVR Drain Valve Kit 1·21A¢Aluminum Cover WI &al 1-21CC Cast Iron Cover wI Seal H12229M Cover Seal 1PPK.2100 Hand Pump & Plug Kiffor 1·2100 1DP.2100 Replacement Drain PIuq.Klt for1-2100 .j r r - .rgr,~"- 4 6---"" " ""' TC400 Torque Cap Provides an easy means of threading a 4' NPT nipple P" into a spill container. The OPW TC-400 coupled with theC~ OPW 61SA-TO0L can provide the necessary torque¶"=:1 """requirements forinstalling adaptor nipples for spill containers. The TC-400 can easily be removed without cQ!7 .disturbing the installed threaded nipple. The TC-400 '~also eliminates the need for a strap or chain wrench. -4" Threaded Pipe Nipple OPW pipe nipples are CNC machined, providing4~a smooth sealing surface where a gasket seal exists.\"" Available in various lengths to cUstom fit the necessary'""& /i height requirements for Fill and Vapor Adaptors. Cj 3,61JSK Jack Screw Device See page 59 for detailed information FM-400 Face Seal Adaptor See page 59 for detailed information. The folbwing prducts are in compliance with California Part#Description Water Resources Conlrol Board (W R.C.B.) for coating SL·1100 _ .Urethane Sealant (10.3 OZ.) of buried metal components, such as stainless steel H15002M Black Rubberized Undercoating (19.75 OZ.) damps or entire Spill Containment Bucket bottoms.wrcb approved CCRTdfe23, Div. 16, Sec 1631 & 2636 cN130pwfum(~mm 9393 Mncetdak Rod 0 Hamifton,0hio USA45011 0 Phone: (BOO) 422-2525 o Fax: (BOO) 421-3297 61 Ck State Of California "=*L"=.CONTRACTORS STATE LICENSE. BOARD k -0 - ''i (}m,u,n,,ACTIVE LICENSE e q Aibin —— 481053 E- CORP —~ KERN COUNTY CONSTRUCTION INC ~.K—¶, B A HAZ ~~* 10/31/2015 —.cslb.ca gov @ . h ,,B e . m " Za' INT'RNATI0NAL =J CODE COUNCIL ,,m,,M,,,,,,m,,,,,,,,,, People Helping People Build a Safer World" '0 "^'.0—'L=u—"'" "'''—'—''' Home > My ICC Navigation Login My Information My CEUS & Certifications My Transactions & Status Member Directory Logout Quick Links · Govemmnt Rdations · ICC Evaluation Service (ICC-ES) · International Accreditation Service (IAS) · International Code Council Foundation (ICCF) Certilied Professional Information: Last HrstMI: Simmons, Josh CerUfkd under this name: Josh Simmons Address: PO Box 6096 City, sme zip: Bakersfield, CA 93386 Phone: (661)634-9950 CertNcation Type(s)' California UST Service Technician (expires 10/07/2015) California UST System Operator (expires 12/05/2015) UST Installation/Retrofitting (expires 12/05/201 5) Vapor Recovery System Testing and Repair (expiros 10/03/2015) Listings here may not reflect today's changes, additions, exam results, or certifications from organizations otherthan ICC (including BOCA, ICBO, and SBCCl). Listings are updated nightly on this web site, so please allow a full 24 hours for changes to be reflected here. ICC certification for code enforcement professions attests to competent knowledge of construction codes arid standards in effect on the date of certification or renewal. ICC does its best to maintain the privacy requests of its members and constituents. If you believe that phone number or address information listed here should not be displayed please contact us at 1-888-ICC-SAFE (422-7233) between Barn and 7pm (CT) for personal assistance Terms of Use: This listing is provided as a service to the constituents of ICC for these purposes: locating a certified professional or contractor in your area, or confirming status for individuals. Any other use, sale, transfer. or reproduction in any form wIthout the express written consent of ICC is strictly prohibited ICC reserves the right to incorporate sme false names to detect improper use of this service Contact Information 1-888-ICC- SAFE (422- 7233), ext. 5524 Contact Us Approve With Confidence Friday,jun13,2014 08:13AM N ¶INVOICE Invoice ID Account ID Date "IN0264049 AR0000182 06/13/2014 P.:!-'I, ."C,',m P'u6lic Health Services L_ f'i:".'.'.",'$":! FA0000182 Make checks payable to:MIKULS TRUCK TERMINAL COUNTY of KERN environmental health services division I I ll I I I I 2700 m street, SUITE 300 BAKERSFIELD, CA 93301-2730 To avoid 50°/, Penalty, pay by:07/13/2014 Now accepting online credit card payments at http://www.co.kern.ca.us/eh Total Due:$0.00 ALAN MIKULS MIKULS TRUCK TERMINAL 2310 TAFT HWY BAKERSFIELD, CA 93313 Amount Paid: mm Please return the top portion of this invoice notice with payment County of Kern RE:MIKULS TRUCK TERMINAL, FA0000182 Environmental Health Services Division 2201 TAFT HWY BAKERSFIELD, CA 93313 Program Date Element Description Invoice # IN0264049 -- Date of Invoice: 06/13/2014 Record Identifier Amount 06/13/2014 CS04 06/13/2014 CC99 UST MODIFICATION MODIFICATION PAYMENT BY CREDIT CARD VISA PD BY ALAN MIKULS PR00002l4 1,770.00 RECEIPT#: DL0000602 PT0013261 -1,770,00 RECEIPT#: DL0000602 Total For this Invoice:0.00 Total Amount Due for this Invoice -- Please Remit this Amount --$0.00 For questions related to your invoice, please feel free to contact us. (661) 862-8713 Food Program (661) 862-8733 Haz Mat Program (661) 862-8727 Solid Waste Program (661) 862-8797 Water/Housing Program You must notify Environmental Health of any changes of : * Ownership * Billing Address * Business Name * Closure FAILURE to notify Environmental Health may result in LATE PENALTIES, PERMIT DENIAL, OR REVOCATION Permits and Fees Paid are NOT TRANSFERABLE 2700 M Street, Suite 300 *Bakersfield, California 93301 *(66 l) 862-8740 *FAX (661) 862-8701 TO: CLERICAL I.TYPING: REQUEST FOR CLERICAL SERVICES FROM: Brody Saleen DATE: May 23, 2016 _ Rough Draft (double spaced) _ Rough Draft (single Spaced) — Final (single spaced) Permit _ Changes to document _ Plain Paper Letterhead Memorandum Other ll.COPIES: # Collate _ Staple _ Return _ copies to sender Ill.MAIL: _ Regular X Certified with return response _ Messenger Envelope Fax Other Enclose Self-Addressed Envelope Distribute: District Staff _ Program Managers (Bill) _ Other (1-Steve, 1- Matt) Mail to:Mikuls Truck Terminal 2310 Taft Hwy Bakersfield, CA 93313 Attn: Alan Mikuls Fax to: Route to: IV.FILING: Make a file for File search for File in file room Other REMARKS: DATE AND TIME NEEDED DATE AND TIME COMPLETED Date Time a.m. _ p.m. _ Date Time By NM m |EE1fc°l4'e'a'|th Services L DEPARTMENT 2700 M srREET. SUITE 300 BAKERSFIELD, CALIFORNIA 93301-2370 MATTHEW CONSTANTINE DIRECTOR VOICE: 661-862-8740 FAX: 661-862-8701 KERNPLJBLICHEALTH COM MAY 23, 2016 Mr. Alan Mikuls Mikuls Truck Terminal 2310TaftHwy Bakersfield, CA 93313 FACILITY ID #: FA0000182 Re: Mikuls Truck Terminal 2201 Taft Hwy Bakersfield, CA 93313 NOTICE OF VIOLATION AND ORDER TO CORRECT Dear Mr. Mikuls: An underground storage tank (UST) inspection was conducted on March 18, 2016 at the Mikuls Truck Terminal facility located at 2201 Taft Hwy, Bakersfield. Violations of the California Health and Safety Code (HSC) Section 6.7, 6.95 and Title 23 California Code of Regulations (CCR) are detailed in the following sections and corrective actions necessary to gain compliance are enclosed as well. The facility has failed to come into compliance within the 30 days required. VIOLATIONS 1. California Code of Regulation (CCR), Title 23 § 2712(f). Permit Conditions: Within 30 calendar days ofreceiving an inspection report from either the local agency or the special inspector, the permit holder shall implement the corrections specified in the inspection report and comply with the permit conditions. The corrective action shall include all of the recommendations made by the local agency or special inspector. The local agency may waive the implementation ofany ofthe special inspector 's recommendation based on a demonstration by the permit holder to the local agency 's satisfaction that failure to implement the recommendation will not cause an unauthorized release. The facility is in violation of Title 23 of the California Code of Regulations (CCR) § 2712 (f) for failure to implement corrections within thirty (30) days. Violations were cited during the inspection and after multiple attempts to contact the facility, they have failed to meet the requirements within the 30 day time frame. The facility has been operating outside the scope of the permit for approximately five (5) months. 2. California Code of Regulation (CCR), Title 23 § 2638(a). Annual Certification of Monitoring Equipment: All monitoring equipment used to satisfy the requirements ofthis article shall be installed, calibrated, operated and maintained in accordance with manufacturer's instructions, and certi/ied every 12 months for operability, proper operating condition, and proper calibration. Written records shall be maintained as required in section 2712. The facility has not completed the annual monitoring certification. Testing must be completed every 12 months. The facility is due every February to complete testing. This is a repeat violation. 3. HSC 6.7 § 25284.2. Underground Storage of Hazardous Substances: The owner or operator ofan underground storage tank with a spill containment structure designed to prevent a release in the event ofa spill or overfill while a hazardous substance is being placed in the tank shall annually test the spill containment structure to demonstrate that it is capable ofcontaining the substance until it is detected and cleaned up. The facility has not completed the annual spill bucket test. Testing must be completed every 12 months. The facility is due every February to complete testing. This is a repeat violation. 4. California Code of Regulation (CCR), Title 23 § 2715(a). Certification, Licensing, and Training Requirements for Underground Storage Tank Owners, Operators, Installers, Service Technicians, and Inspectors: By January 1, 2005, owners ofunderground storage tank systems shall submit a signed statement to the local agency indicating that the owner understands and is in compliance with all applicable underground storage tank requirements, and identifying the designated UST operator® for each facility owned. The owner shall inform the local agency ofany change of designated UST operator(s) no later than 30 days after the change. During the course of the 2015 monitoring certification, it was observed that the individual performing the monthly inspections had an expired certification (04/15). The last California Environmental Reporting System (CERS) UST update was in June, 2014 and since then, all designated operator information has expired. An updated form with active certifications needs to be uploaded onto CERS. 5. California Code of Regulation (CCR), Title 23 § 27l5(c)(6). Certification, Licensing, and Training Requirements for Underground Storage Tank Owners, Operators, Installers, Service Technicians, and Inspectors: The designated UST operator(s) shall perform monthly visual inspections ofall underground storage tank systems for which they are designated. The results ofeach inspection shall be recorded in a monthly inspection report. The monthly visual inspection shall include, but is not limited to, the following: (I) Reviewing the alarm history report or log for the previous month, and checking that each alarm condition was documented and responded to appropriately. A copy ofthe alarm history report or log, along with documentation describing action taken in response to any alarm(s), shall be attached to the monthly visual inspection record. (2) Inspecting for the presence ofhazardous substance, water, or debris in spill containers. (3) Inspecting for the presence ofhazardous substance, water, or debris in under-dispenser containment areas, and checking that the monitoring equipment in these areas is located in the proper position to detect a leak at the earliest possible opportunity. (4) Inspecting for the presence ofhazardous substance, water, or debris in containment sumps that, in the past month, have had an alarm for which there is no record ofa service visit, and checking that the monitoring equipment in these containment sumps is located in the proper position to detect a leak at the earliest possible opportunity. (5) Checking that all required testing and maintenance for the underground storage tank system have been completed, and documenting the dates these activities occurred, (6) Verifying that all facility employees have been trained in accordance with subdivision 2715(/) During the course of the 2015 monitoring certification, it was observed that the designated operator had not conducted the employee training for 2014 and 2015. 6. HSC 6.95 § 25508.2. Business and Area Plans: On or befOre the annual due date established pursuant to subparagraph (B) ofparagraph (l) of subdivision (a) ofSection 25508, the business owner, business operator, or o©cially designated representative ofthe business shall review and certY that the information in the statewide information management system is complete, accurate, and in compliance with Section 11022 of Title 42 ofthe United States Code. An annual electronic submittal to the statewide information management system satisfies the certi/ication requirement of this section. The facility has failed to complete their annual CERS submittal. The last submittal was on January 26, 2015. 7. HSC 6.95 § 25514.5(b). Business and Area Plans: Notwithstanding Section 25514, any business that knowingly violates this article a/ier reasonable notice ofthe violation is liable for an administrative penalty, not greater than jive thousand ($5,000) jbr each day in which the violation occurs. Failure to implement corrective action stated within 15 days after receiving this notice may result in the issuance of an Administrative Enforcement Order (AEO), including penalties up to $5,000 per violation, per day. You will also be responsible for re-inspection fees of $115.00 per hour for time spent by department staff. You are strongly advised to correct the violations within the time lines provided in order to avoid further enforcement action. CORRECTIVE ACTION The following corrective actions must be completed within 15 days of receiving this notice: ·Complete and submit all necessary documentation onto the CERS website. ·Contact a third party testing agency to set up a time/date to conduct the annual monitoring certification. ·Have the third party testing agency contact the CUPA department to confirm the scheduled test. The issuance of this Notice of Violation and Order to Correct does not preclude Kern County Environmental Health Division, Hazardous Materials Management Program from taking administrative, civil or criminal action as a result of the violations noted herein. If you have any questions, please call me at (661) 862-8716. Sincerely, Baj/ jbm- Brody Saleen, REHS Registered Environmental Health Specialist Unified Hazardous Materials/Waste Program Cc: File REQUEST FOR CLERICAL SERVICES TO: CLERICAL I.TYPING: FROM: Brody Saleen DATE: July 20, 2016 _ Rough Draft (double spaced) _ Rough Draft (single Spaced) _ Final (single spaced) Permit _ Changes to document _ Plain Paper Letterhead Memorandum Other ll.COPIES: # Collate _ Staple _ Return _ copies to sender Ill.MAIL: Distribute: District Staff _ Program Managers (Bill) _ Other (1-Steve, 1- Matt) _ Regular X Certified with return response _ Messenger Envelope Fax Other Enclose Self-Addressed Envelope Mail to:Mikuls Truck Terminal 2100 Povane CT Bakersfield, CA 93313 Attn: Leslyn Ann Knight Fax to: Route to: IV.FILING: Make a file for File search for File in file room Other REMARKS: DATE AND TIME NEEDED DATE AND TIME COMPLETED Date Time a.m._ p.m. _ Date Time By NM !¶ PCE|fc%'e'aith Services W DEPARTMENT 27OC) M STREET, SUITE 30O BAKERSFIELD, CALIFORNIA 93301-237D MATTHEW CONSTANTINE DIRECTOR VOICE: 661-862-8740 FAX: 661-862-8701 KERNPUBLICHEALTH COM July 20, 2016 Ms. Leslyn Ann Knight Mikuls Truck Terminal 21O0 Povane CT Bakersfield, CA 93313 FACILITY ID #: FA0000182 Re: Mikuls Truck Terminal 2201 Taft Hwy Bakersfield, CA 93313 NOTICE OF VIOLATION AND ORDER TO CORRECT Dear Ms. Knight: An underground storage tank (UST) inspection was conducted on March 18, 2O16 at the Mikuls Truck Terminal facility located at 2201 Taft Hwy, Bakersfield. Violations of the California Health and Safety Code (HSC) Section 6.7, 6.95 and Title 23 California Code of Regulations (CCR) are detailed in the following sections and corrective actions necessary to gain compliance are enclosed as well. The facility has failed to come into compliance within the 30 days required. VIOLATIONS 1. California Code of Regulation (CCR), Title 23 § 2712(f). Permit Conditions: Within 30 calendar days ofreceiving an inspection report from either the local agency or the special inspector, the permit holder shall implement the corrections specified in the inspection report and comply with the permit conditions. The corrective action shall include all of the recommendations made by the local agency or special inspector. The local agency may waive the implementation ofany of the special inspector 's recommendation based on a demonstration by the permit holder to the local agency 's satisfaction that failure to implement the recommendation will not cause an unauthorized release. The facility is in violation of Title 23 of the California Code of Regulations (CCR) § 2712 (f) for failure to implement corrections within thirty (3O) days. Violations were cited during the inspection and after multiple attempts to contact the facility, they have failed to meet the requirements within the 30 day time frame. The facility has been operating outside the scope of the permit for approximately five (5) months. 2. California Code of Regulation (CCR), Title 23 § 2638(a). Annual Certification of Monitoring Equipment: All monitoring equjpment used to satisfy the requirements ofthis article shall be installed, calibrated, operated and maintained in accordance with manufacturer's instructions, and certified every 12 months for operability, proper operating condition, and proper calibration. Written records shall be maintained as required in section 2 712. The facility has not completed the annual monitoring certification. Testing must be completed every 12 months. The facility is due every February to complete testing. This is a repeat violation. 3. HSC 6.7 § 25284.2. Underground Storage of Hazardous Substances: The owner or operator ofan underground storage tank with a spill containment structure designed to prevent a release in the event ofa spill or over/ill while a hazardous substance is being placed in the tank shall annually test the spill containment structure to demonstrate that it is capable ofcontaining the substance until it is detected and cleaned up. The facility has not completed the annual spill bucket test. Testing must be completed every 12 months. The facility is due every February to complete testing. This is a repeat violation. 4. California Code of Regulation (CCR), Title 23 § 2715(a). Certification, Licensing, and Training Requirements for Underground Storage Tank Owners, Operators, Installers, Service Technicians, and Inspectors: By January 1, 2005, owners ofunderground storage tank systems shall submit a signed statement to the local agency indicating that the owner understands and is in compliance with all applicable underground storage tank requirements, and identifying the designated UST operator(s) for each facility owned. The owner shall inform the local agency ofany change of designated UST operator(s) no later than 30 days a/ier the change. During the course of the 2015 monitoring certification, it was observed that the individual performing the monthly inspections had an expired certification (04/15). The last California Environmental Reporting System (CERS) UST update was in June, 2014 and since then, all designated operator information has expired. An updated form with active certifications needs to be uploaded onto CERS. 5. California Code of Regulation (CCR), Title 23 § 2715(C)(6). Certification, Licensing, and Training Requirements for Underground Storage Tank Owners, Operators, Installers, Service Technicians, and Inspectors: The designated UST operator(s) shall perform monthly visual inspections ofall underground storage tank systems for which they are designated. The results ofeach inspection shall be recorded in a monthly inspection report. The monthly visual inspection shall include, but is not limited to, the following: (l) Reviewing the alarm history report or log for the previous month, and checking that each alarm condition was documented and responded to appropriately. A copy ofthe alarm history report or log, along with documentation describing action taken in response to any alarm(s), shall be attached to the monthly visual inspection record. (2) Inspecting for the presence ofhazardous substance, water, or debris in spill containers. (3) Inspecting for the presence ofhazardous substance, water, or debris in under-dispenser containment areas, and checking that the monitoring equipment in these areas is located in the proper position to detect a leak at the earliest possible opportunity. (4) Inspecting for the presence ofhazardous substance, water, or debris in containment sumps that, in the past month, have had an alarm for which there is no record ofa service visit, and checking that the monitoring equjpment in these containment sumps is located in the proper position to detect a leak at the earliest possible opportunity. (S) Checking that all required testing and maintenance for the underground storage tank system have been completed, and documenting the dates these activities occurred. (6) Veritj'ing that all facility employees have been trained in accordance with subdivision 2715(/) During the course of the 2015 monitoring certification, it was observed that the designated operator had not conducted the employee training for 2014 and 2015. 6. HSC 6.95 § 25508.2. Business and Area Plans: On or before the annual due date established pursuant to subparagraph (B) ofparagraph (I) of subdivision (a) ofSection 25508, the business owner, business operator, or o©cially designated representative ofthe business shall review and certify that the information in the statewide information management system is complete, accurate, and in compliance with Section /1022 of Title 42 ofthe United States Code. An annual electronic submittal to the statewide information management system satisfies the certification requirement ofthis section. The facility has failed to complete their annual CERS submittal. The last submittal was on January 26, 2015. 7. HSC 6.95 § 25514.5(b). Business and Area Plans: Notwithstanding Section 25514, any business that knowingly violates this article after reasonable notice ofthe violation is liable for an administrative penalty, not greater than jive thousand ($5,000) for each day in which the violation occurs. Failure to implement corrective action stated within 15 days after receiving this notice may result in the issuance of an Administrative Enforcement Order (AEO), including penalties up to $5,O00 per violation, per day. You will also be responsible for re-inspection fees of $115.00 per hour for time spent by department staff. You are strongly advised to correct the violations within the time lines provided in order to avoid further enforcement action. CORRECTIVE ACTION The following corrective actions must be completed within 15 days of receiving this notice: ·Complete and submit all necessary documentation onto the CERS website to show change of owner/operator. ·Contact a third party testing agency to set up a time/date to conduct the annual monitoring certification. ·Have the third party testing agency contact the CUPA department to confirm the scheduled test. The issuance of this Notice of Violation and Order to Correct does not preclude Kern County Environmental Health Division, Hazardous Materials Management Program from taking administrative, civil or criminal action as a result of the violations noted herein. If you have any questions, please call me at (661) 862-8716. KU- B,od, Salem, REHS Registered Environmental Health Specialist Unified Hazardous Materials/Waste Program Cc: File