Loading...
HomeMy WebLinkAbout1.2-7253 Ph 1 & 2 Record DrawingTRACT 7253 PHASES 1 AND 2 (-%Al IFORNIA MAvr:DQc:lELD L..;® U`aL.Ii ja..i I REVIEWED BY: ASSISTANT PUBLIC WORKS DIRECTOR, CITY OF BAKERSFIELD DATE THEODORE D. WRIGHT C 33710 APPROVED BY: PUBLIC WORKS DIRECTOR, CITY OF BAKERSFIELD NICOLAS FIDLER C 61069 IDL\I0 BENCHMARK USED: TOP OF BRASS DISK ON TOP OF HEADWALL AT SOUTHEAST CORNER OF PANAMA LANE AND SOUTH "H" STREET NATIONAL GEODETIC SURVEY BENCHMARK DESIGNATION X 364 PID FU1624 ELEVATION - 349.00 (U.S.G.S. DATUM) BASIS OF BEARINGS: THE BEARING SOUTH 89°32'17" EAST SHOWN FOR THE NORTH LINE OF THE NORTHWEST QUARTER OF SECTION 6, TOWNSHIP 31 SOUTH, RANGE 28 EAST, MOUNT DIABLO BASE AND MERIDIAN (ALSO BEING THE CENTERLINE OF TAFT HIGHWAY - COUNTY RD NO. 25 & 2387) AS SHOWN ON LOT LINE ADJUSTMENT NO. 56-94 WAS USED AS THE BASIS OF BEARINGS SHOWN HEREON. VICINITY MAP NO SCALE LEGEND TMH- TOP OF MANHOLE ELEVATION INV.- PIPE INVERT ELEVATION (E,S,N,W)- (EAST, SOUTH, NORTH, WEST) P.V.C.- POLYVINYL CHLORIDE t - APPROXIMATE LENGTHS, CONTRACTOR SHALL VERIFY ALL LENGTHS PRIOR TO BIDDING THIS PROJECT R.C.P.- REINFORCED CONCRETE PIPE R.G.J.- RUBBER GASKET JOINT CB- CATCH -BASIN MATERIAL'S LIST SEWER PHASE 1 PHASE 2 TOTAL 10" SEWER MAIN 597 LF 0 LF 558 LF 8" SEWER MAIN 1,053 LF 984 LF 2,048 HE 6" SEWER MAIN 394 LF 968 LF 1,372 LF 4" SEWER LATERALS 1.080LF 1,692 LF 2 772 LF SEWER MANHOLES (e 3 EA 6 EA RA, SEWER CLEANOUTS Q 2 EAADJUST MANHOLES TO FINISH GRAD (oa EA8 EA STORM DRAIN 24" R.C.P. STORM DRAIN 0 LF 567 LF 567 LF EAST HOSKING 0 LF AVENUE LF 542 � I w w EA 4 EA 4 EA STORM DRAIN MANHOLES 0 EA 4 McKEE ROAD 4 EA McKEE ROAD 0 EA 36 EA 4 31 OUTLET STRUCTURE 0 EA 1 EA w EA C- Q SSNt x z � a 5/{11 `J F- U 0 Z Q OUR _ C #2 LL W PROJECT 31TE TAFT-- — HIGHWAY- oe -- 2 0 m N 12 -N- U T I ROAD 6 f �j`� L/ I 37 38 3 40 w s, 42 --N-> o z 47 > o i cn c v � VICINITY MAP NO SCALE LEGEND TMH- TOP OF MANHOLE ELEVATION INV.- PIPE INVERT ELEVATION (E,S,N,W)- (EAST, SOUTH, NORTH, WEST) P.V.C.- POLYVINYL CHLORIDE t - APPROXIMATE LENGTHS, CONTRACTOR SHALL VERIFY ALL LENGTHS PRIOR TO BIDDING THIS PROJECT R.C.P.- REINFORCED CONCRETE PIPE R.G.J.- RUBBER GASKET JOINT CB- CATCH -BASIN MATERIAL'S LIST SEWER PHASE 1 PHASE 2 TOTAL 10" SEWER MAIN 597 LF 0 LF 558 LF 8" SEWER MAIN 1,053 LF 984 LF 2,048 HE 6" SEWER MAIN 394 LF 968 LF 1,372 LF 4" SEWER LATERALS 1.080LF 1,692 LF 2 772 LF SEWER MANHOLES (e 3 EA 6 EA RA, SEWER CLEANOUTS Q 2 EAADJUST MANHOLES TO FINISH GRAD (oa EA8 EA STORM DRAIN 24" R.C.P. STORM DRAIN 0 LF 567 LF 567 LF 18" R.C.P. STORM DRAIN 0 LF 542 LF 542 LF TYPE "A" CATCH BASINS 0 EA 4 EA 4 EA STORM DRAIN MANHOLES 0 EA 4 EA 4 EA ADJUST MANHOLES TO FINISH GRADE 0 EA 4 EA 4 EA OUTLET STRUCTURE 0 EA 1 EA 1 EA obr� p5I39j2 `' ExP'F'{ x6w F'AAs E q3 -I ENGINEER'S STATEMENT Pp1i0FESSlpv �GpF0fESSIn i vanww4 ��� 00 o F h�P �GOAY o Y (u �M D(ZAwldl� - Lg QEF m o " y �hRXs 0939322 �/ TA111 �3 9�OF CALiFOP�s 9�OFCAl1FOP v �vt�t4n1 APtFcoGO BY� JA � l/'�"¢-- •/o�/li I y�6500,Y S&AG:," 53952 P14M nI n 1 Vtjl+M AtPAD%q INY: 14111/17 �.`I 2AdIS� PAD<uA RtS t_?0o8 I?A716: I HEREBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS COMPLY WITH CITY OF BAKERSFIELD ORDINANCES, STANDARDS, AND DESIGN CRITERIA, AND THAT THEY INCLUDE ALL IMPROVEMENT REQUIREMENTS OF THE ADVISORY AGENCY OR OTHER REVIEW BOARD I AM RESPONSIBLE FOR ALL CALCULATIONS AND DRAWINGS ON THESE PLANS AND ANY ERRORS, OMISSIONS OR VIOLATIONS OF THOSE ORDINANCES, STANDARDS, OR DESIGN CRITERIA ENCOUNTERED DURING CONSTRUCTION SHALL BE CORRECTED DURING CONSTRUCTION AND ALL SUCH CORRECTIONS SHALL BE REFLECTED ON REVISED OR AS -BUILT PLANS TO BE SUBMITTED TO THE CITY ENGINEER. rN RCE 53952 BATF: EXP. 12/31/2017 KERN DELTA WATER DISTRICT NOTE PRIOR TO CONSTRUCTION, KERN DELTA WATER STORAGE DISTRICT (661) 834-4656 SHALL BE NOTIFIED TO ENSURE THAT PROPOSED CONSTRUCTION WILL NOT INTERFERE WITH KERN DELTA'S ABILITY TO MAINTAIN WATER DELIVERY TO PROPERTIES EAST OF SUBJECT PROPERTY. ►LCGT4 AN OPEN STREET PERMIT SHALL BE OBTAINED FROM THE CITY OF BAKERSFIELD PUBLIC WORKS DEPARTMENT FOR ANY WORK PERFORMED WITHIN EXISTING ACCEPTED STREET RIGHT OF WAY. UNLESS SECURED BY A SUBDIVISION AGREEMENT, SECURITY BASED ON AN APPROVED ENGINEER'S ESTIMATE FOR THE WORK PERFORMED WITHIN RIGHT OF WAY AND INSURANCE AS REQUIRED SHALL BE PROVIDED PRIOR TO ISSUANCE OF A PERMIT. LI I I \,L-L1J SHEET No. INDEX r O1 TITLE SHEET E -4 O2 NOTES I_I D�eTAFT HIGHWAY I- - HEATHER MEADOWS DRIVE fi r (LD LIBERTY RIDGE COURT �J L -I- J © JAMES VALLEY COURT O PITCHER VIEW COURT-�I ® GARETT CANYON DRIVE 4 �L - LEGEND — ~ �- ( SHEET INDEX NUMBER �-- I r OS SS#12 SEWER MANHOLE W/NUMBER I� © CO#12 SEWER CLEANOUT W/NUMBER r —I r--— Oo SD#12 STORM DRAIN MANHOLE W/NUMBER L �- + I- __R_CB#12 CATCH BASIN W/NUMBER I— I - I -- PROPOSED SEWER MAIN OR STORM DRAIN I\L—I L EXISTING SEWER MAIN OR STORM DRAIN I-r7-� I I _j TAFT HIGHWAY --- Ili III' I PI I 32 1 31 1 30 1 29 12B 1 27 1 26 125 24 11 /12 113 114 24 l c 23 1 22 1 21 1 20 16717118 79 20 21 PHA[E 1 PHA E 2 16 17 16 15 14 , 5@9, 2526 � 27 26 29 30 00 aUg� B 9 70 '1 12 LiJ Li J Q U Z Q N 0 Lz � J � 7Q w Y Z_ U 36 35 34 33 32 31 6 5 4 3 2 1 o 0 C- O SSNt PIT HER 5/{11 `J F- U VIE Z Q OUR _ C #2 LL W Q m W V) SO 2 0 1 s 12 -N- U T [43 f �j`� L/ I 37 38 399 40 41 42 44 45 46 47 IIJ KEY MAP SCALE: V=200' UNCERGiOUND SESVIGc ALERT OF SOUTHERN CA FORNI.A DIALTOLL FREE 1-900-227-2600 AT LEAST TWO DAYS BEFORE YOU C G COB RECORDS No. Engineering Land suvev"uO r � z r z O_ 00 G_ F- 00 O LiJ Li J Q U Z Q N 0 Lz � J � r o m m V O W � z Iw ¢¢ otw-m a Y U cn z O L0 w SHEET 1 of 8 SHTS.I Q z z O_ G_ F- O LiJ Li J Q U Z Q N 0 Lz � J � 7Q w Y Z_ U O Q U w �L 1n T wQ Z w �a o 0 <N O S a r,w U `J F- U E Z Q U a 1n O- rY LL W Q m W V) O U SHEET 1 of 8 SHTS.I z O_ F- LiJ U � (n W U W T � w O w S (L (n SHEET 1 of 8 SHTS.I GENERAL NOTES 1. ALL CONSTRUCTION SHALL CONFORM TO THIS PLAN, THE CALIFORNIA BUILDING CODE, CITY OF BAKERSFIELD ORDINANCE, LATEST EDITION AND STANDARDS PERTAINING THERETO. THESE DOCUMENTS SHALL BE MADE A PART HEREOF. 2. ALL CONSTRUCTION WITHIN THE CITY RIGHT-OF-WAY OR CITY EASEMENTS SHALL BE IN ACCORDANCE WITH CITY OF BAKERSFIELD STANDARDS AND STATE OF CALIFORNIA, DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS DATED 2010. THESE STANDARDS, DRAWINGS AND DETAILS SHALL BE CONSIDERED A PART OF THESE PLANS AND THE CONTRACTOR SHALL OBTAIN A COPY FOR HIS USE. 3. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL NECESSARY PERMITS BEFORE START OF CONSTRUCTION. AN OPEN STREET PERMIT SHALL BE OBTAINED FROM THE CITY OF BAKERSFIELD PUBLIC WORKS DEPARTMENT FOR ANY WORK TO BE PERFORMED IN THE EXISTING, ACCEPTED STREET RIGHT-OF-WAY. UNLESS SECURED BY AN IMPROVEMENT AGREEMENT, APPROVED INSURANCE AND SECURITY BASED ON AN APPROVED ENGINEER'S ESTIMATE FOR THE WORK PERFORMED WITHIN THE STREET RIGHT-OF-WAY SHALL BE POSTED PRIOR TO ISSUANCE OF A PERMIT. 4. 24 HOUR NOTICE: PRIOR TO THE START OF ANY PHASE OF CONSTRUCTION, THE CITY CONSTRUCTION INSPECTION SECTION SHALL BE GIVEN AT LEAST 24 HOURS NOTICE. THE SECTION MAY BE NOTIFIED AT (661) 326-3049. 5. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING DIMENSIONS, DATA AND MEASUREMENTS AT THE BUILDING SITE PRIOR TO CONSTRUCTION. DO NOT SCALE DRAWINGS. WRI-TEN DIMENSIONS ON TFESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. PORTER & ASSOCIATES, INC. MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN SY THESE DRAWINGS. 6. EXISTING UTILITY AND UNDERGROUND LINES HAVE BEEN SHOWN ON THIS PLAN ACCORDING TO AVAILABLE RECORDS, THE ENGINEER IS NOT RESPONSIBLE FOR POSSIBLE ERRORS OR OMISSIONS. THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF THE LOCATION AND DEPTH OF ALL UTILITIES PRIOR TO BEGINNING OF ANY WORK, UNDERGROUND SERVICE ALERT (U.S.A.: 1-800-227-2600) SHALL BE CONTACTED AT LEAST TWO WORKING DAYS PRIOR TO ANY CONSTRUCTION OR EXCAVAHON. 7. ANY EXISTING IMPROVEMENTS OR UTILITIES THAT ARE REMOVED, DAMAGED OR UNDERCUT BY CONTRACTOR'S OPERATIONS SHALL BE REPAIRED OR REPLACED AT THE CONTRACTOR'S EXPENSE, AS DIRECTED BY THE ENGINEER AND APPROVED BY THE GOVERNING AUTHORITY, 8. IF A PROBLEM OR CONFLICT SHOULD ARISE DURING THE COURSE OF THE PROJECT, IT IS THE RESPONSIBILITY OF THE OWNER OR THE CONTRACTOR TO NOTIFY THE ENGINEER IMMEDIATELY PRIOR TO ANY FURTHER WORK. 9. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, TOOLS, EQUIPMENT AND SUPERVISION NECESSARY FOR A COMPLETE AND FUNCTIONAL PRODUCT. 10. ALL WORK WHICH IS DEFECTIVE IN ITS CONSTRUCTION OR DEFICIENT IN ANY OF THE REQUIREMENTS OF THESE DRAWINGS AND SPECIFICATIONS SHALL BE REMEDIED, OR REMOVED AND REPLACED BY THE CONTRACTOR IN AN ACCEPTABLE MANNER, AND NO COMPENSATION WILL BE ALLOWED FOR SUCH CORRECTION. 11. IN THE EVENT CONSTRUCTION STAKING BASED ON THE CONSULTANT'S PLANS, DRAWINGS OR OTHER DOCUMENTS IS ACCOMPLISHED BY ANYONE OTHER THAN THE CONSULTANT, THE OWNER OR CONTRACTOR SHALL NOTIFY THE BUILDING OFFICIAL IN WRITING AS TO THE CHANGE OF ENGINEER IN RESPONSIBLE CHARGE. 12. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT; INCLUDING EROSION, SEDIMENTATION & DUST CONTROL PLAN AND STORM WATER POLLUTION PREVENTION PLAN IMPLEMENTATION AND THE SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR THE ENGINEER. 13. IF THE CONTRACTOR IS IN DOUBT AS TO THE MEANING OF ANY PART OF THE DRAWINGS AND SPECIFICATIONS OR FINDS DISCREPANCIES IN OR OMISSIONS FROM THE DRAWINGS, HE SHALL SUBMIT A WRITTEN REQUEST FOR AN INTERPRETATION OR A CORRECTION THEREOF, PRIOR TO FILING HIS BID PRICE FOR THE PROJECT. 14. PALMETTO ENGINEERING AND LAND SURVEYING, INC. WILL NOT BE RESPONSIBLE OR LIABLE FOR UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS. ANY AND ALL CHANGES TO THESE PLANS MUST BE APPROVED IN WRITING BY PALMETTO ENGINEERING AND LAND SURVEYING, INC. 15. NORMAL STAKING AND MARKING OF THE PROJECT VALE BE SUPPLIED ONLY ONCE, ALL RESTAKING OR REMARKING SHALL BE AT THE EXPENSE OF THE CONTRACTOR. 16. SEE WATER AND STREET IMPROVEMENT PLANS FOR OTHER IMPROVEMENTS THAT ARE PART OF THIS PROJECT. 17. NO PUBLIC WORKS INSPECTIONS WILL BE GIVEN FOR THE WORK IN THE UNDEDICATED ROADWAYS IN THIS PROPERTY UNTIL A SUBDIVISION PERMIT HAS BEEN OBTAINED. 18. NOTE CONTRACTOR SHALL STAMP AND "S" INTO CURB FACE OVER EACH SEWER LATERAL. 19. ANY ITEMS IN PUBLIC RIGHT-OF-WAY THAT ARE DAMAGED OR DO NOT MEET CURRENT STANDARDS SET BY PUBLIC WORKS WILL REQUIRE REPAIRING AND/OR UPGRADING AS PER CITY ENGINEER. COB SEWER SPECIFICATIONS 1. ALL MATERIALS INSTALLATION SHALL CONFORM TO CHAPTER 1 OF THE CITY OF BAKERSFIELD SUBDIVISION DESIGN MANUAL AND WITH THE RECOMMENDATIONS OF THE MANUFACTURER, 2. ALL PIPE AND FITTINGS SHALL BE MARKED OR STAMPED WITH THE TRADE BRAND NAME OF THE MANUFACTURER, AND STRENGTH OR CLASS OF PIPE. 3. PVC PIPE INSTALLATION: A. MATERIALS: PIPE AND FITTINGS SHALL MEET THE REQUIREMENTS OF ASTM SPECIFICATIONS D3034 AND SDR -35. PIPE AND FITTINGS SHALL BE HOMOGENEOUS THROUGHOUT AND FREE FROM CRACKS, HOLES, FOREIGN INCLUSIONS OR OTHER INJURIOUS DEFECTS. FITTINGS SHALL BE INJECTION MOLDED AND SHALL BE INSTALLED IN LINE ON NEW PIPELINES; CUT -IN FITTINGS ARE NOT PERMITTED. B. JOINTS: USE ONLY ELASTOMERIC GASKET JOINTS. THE ASSEMBLY OF JOINTS SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE PVC PIPE CONNECTS TO VCP, USE COUPLINGS APPROVED BY THE CITY OF BAKERSFIELD. C. INSTALLATION: PIPE AND FITTINGS SHOULD BE INSTALLED IN ACCORDANCE WITH ASTM D2321. ONLY CLASS I OR II EMBEDMENT MATERIALS WILL BE CONSIDERED SUITABLE. 4. FOR CURVED PIPE: IDENTIFICATION TAPE DESIGNED FOR USE ON SEWERS SHALL BE PLACED ON TOP OF SEWER MAIN ALONG ITS ENTRE LENGTH. IDENTIFICATION TAPE SHALL ALSO BE PLACED ON SEWER LATERALS EXTENDING FROM SEWER MAIN TO RIGHT-OF-WAY LINE. 5. SURFACE MARKERS FOR SEWER LATERALS SHALL BE INSTALLED AT PROPERTY LINE PER C.O.B. STD. SW -1, UNLESS OTHERWISE NOTED ON PLANS. 6. WYE -FITTINGS SHALL BE INJECTION MOLDED IN-LINE AND SHALL BE USED FOR ALL LATERAL CONNECTIONS AND SHALL BE ROTATED A MINIMUM OF 23' AND A MAXIMUM OF 45' ABOVE THE HORIZONTAL PLANE RUNNING THROUGH THE CENTERLINE OF THE MAIN. WYE FITTINGS ONLY SHALL BE USED FOR VCP. ALL SEWER STUBS SHALL BE CLOSED WITH A S-ANDARD PLASTIC PLUG (SOLVENT WELDED). 7. ALL LATERALS SHALL EXTEND TO A MINIMUM OF FOUR FEET BEYOND THE PROPERTY LINE AND SHALL BE 4" IN DIAMETER EXCEPT AS NOTED ON PLANS, 8, THE MANHOLES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF BAKERSFIELD DRAWINGS SW -4 AND SW -5 AND SECTION 70-1.02H AND 71-1.07 OF THE STANDARD SPECIFICATIONS OF THE STATE OF CALIFORNIA, DEPARTMENT OF TRANSPORTATION, LATEST EDITION. 9. THE CLEANOUTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF BAKERSFIELD STANDARD DRAWINGS SW -6. 10. SYSTEM TESTING: INSTALLED PIPE SHALL BE CLEANED AND TESTED IN ACCORDANCE IMTH CHAPTER 1.3 OF THE SUBDIVISION DESIGN MANUAL AND WITH THE RECOMMENDATIONS OF THE MANUFACTURER AND ACCEPTABLE TO THE CITY OF BAKERSFIELD. 24 HOURS NOTICE WILL BE REQUIRED FOR TEST AND INSPECTION. 11. PRIOR TO FINAL ACCEPTANCE OF THE SEWER SYSTEM, ALL MAIN LINES SHALL BE INSPECTED WITH VIDEO EQUIPMENT DESIGNED FOR THIS PURPOSE AND AS APPROVED BY THE CITY ENGINEER. THE TELEVISION CAMERA SHALL HAVE THE CAPABILITY OF ROTATING 360', IN ORDER TO VIEW AND RECORD THE TOP AND SIDES OF THE PIPE, AS REQUIRED. THE VIDEO INSPECTIONS SHALL BE WITNESSED BY CITY'S CONSTRUCTION INSPECTOR, WHO WILL ALSO INITIAL AND DATE THE "CHAIN OF CUSTODY' FORM. THE SUBDIVIDER SHALL IMMEDIATELY NOTIFY CITY OF ANY PIPE LOCATIONS REVEALED TO BE NOT IN COMPLIANCE WITH THE SPECIFICATIONS. A RECORDED VIDEO CASSETTE, THE COMPLETED "CHAIN OF CUSTODY" FORM AND A WRITTEN LOG (WHICH INCLUDES THE STATIONING, BASED ON THE STATIONING OF THE APPROVED PLANS, OF ALL CONNECTED LATERALS) OF THE INSPECTION SHALL BE PROVIDED FOR VIE`MNG AND SHALL BE APPROVED BY THE CITY ENGINEER PRIOR TO ACCEPTANCE. AFTER ACCEPTANCE OF THE SYSTEM, THE VIDEO CASSETTE, FORMS AND LOGS SHALL BECOME THE PROPERTY OF THE CITY. CONNECTION SEAL TO PVC LINED SEWER LINE OR MANHOLE 1, THE CORED HOLE SHALL BE APPROXIMATELY 3 INCHES GREATER THAN THE OUTSIDE DIAMETER OF THE CONNECTING LINE. THE CORED HOLE SHALL BE DESIGNED TO CUT A HOLE WITH MINIMUM DAMAGE TO THE REINFORCING STEEL, PIPE OR PLASTIC LINER. 2. PRIOR TO THE INSTALLATION OF THE PVC BOOT ON THE CONNECTION, THE PLASTIC LINER AROUND THE PIPE AT THE CORED HOLE SHALL BE CLEANED PER THE P'_ASTIC LINER MANUFACTURER'S RECOMMENDATION. THE END OF THE CONNECTING LINE SHALL BE SEALED TO THE PVC BOOT WITH SIKA 449/203 PRIMER AND SIKA FLEX 1A SEALANT OR AN APPROVED EQUAL. 3. THE PVC BOOT SHALL BE ORDERED 50 IT WILL FIT SNUGGLY TO THE OUTSIDE WALL OF THE CONNECTON. 4. THE PVC BOOT AND WELD STRIPS SHALL BE INSTALLED AND TESTED FOR HOLIDAYS PER THE PLASTIC LINER MANUFACTURER'S RECOMMENDATIONS. 5. THE CONNECTION LINE SHALL BE CENTERED IN THE CORED HOLE AND PLACED SO IT IS FLUSH WITH THE INSIDE WALL OF THE RCP. 6. THE PVC BOOT WELD STRIPS SHALL BE MANUFACTURED BY AMERON, INC. OR AN EQUAL APPROVED BY THE CITY ENGINEER. COB STORM DRAIN NOTES 1. UNLESS OTHERWISE SPECIFIED ON THESE PLANS, THE STORM DRAIN PIPE SHALL BE THE FOLLOWING: A. REINFORCED CONCRETE PIPE (R.C.P): REINFORCED CONCRETE PIPE SHALL BE CLASS III (ASTM C76) AND SHALL CONFORM TO THE REQUIREMENTS OF SECTION 65 OF THE STANDARD SPECIFICATIONS. (SEE GENERAL NOTE 2) B. JOINTS SHALL BE RUBBER GASKETED IN CONFORMANCE WITH THE PROVISIONS OF SECTION 65-1.05 OF THE STANDARD SPECIFICATIONS. C. CONCRETE PIPE SHALL BE LAID IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 65 OF THE STANDARD SPECIFICATIONS. (SEE GENERAL NOTE 2) D. IN ADDITION TO THE ABOVE REQUIREMENTS, ALL RUBBER GASKETED JOINT RINGS SHALL BE CHECKED WITH A GAUGE ALL THE WAY AROUND THE PIPE AFTER THE JOINT HAS BEEN ASSEMBLED TO DETERMINE THAT THE RING HAS BEEN PROPERLY LOCATED AND SEATED. IMPROPERLY MADE JOINTS SHALL BE PULLED APART AND SATISFACTORILY REMADE. COB TRENCHING NOTES 1. TRENCHING SHALL MEET THE REQUIREMENTS OF CAL -OSHA TRENCHING ORDERS AND THE CONTRACTOR SHALL COMPLY WITH SECTION 6422 OF THE LABOR CODE. 2. ANY TRENCHING TO BE CONDUCTED WITHIN CITY RIGHT-OF-WAY SHALL BE BACKFILLED AND COMPACTED PER CITY OF BAKERSFIELD STANDARD DETAIL ST -22. 3. ALL EXISTING PAVING AND SURFACING REMOVED, DAMAGED OR UNDERCUT SHALL BE REPLACED IN ACCORDANCE WITH THE CITY OF BAKERSFIELD DRAWING ST -6. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DEWATERING ALL TRENCHES. IF TRENCHES OR PIPING BECOME DAMAGED DUE TO WATER INFILTRATION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO REPAIR THE TRENCH AND PIPING TO THE SATISFACTION OF THE ENGINEER AT THE CONTRACTOR'S EXPENSE. 5. FLOODING OR WATERJETTING SHALL NOT BE USED FOR BACKFILL COMPACTION. 6. CLASS I BEDDING AND EMBANKMENT IS REQUIRED FOR ALL PLASTIC SEWER PIPE WITHIN THE PIPE ZONE. CLASS I BACKFILL IS NOT REQUIRED IF PIPE SLOPE EXCEEDS 1%. 7. COMPACTION TESTS SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. THE NUMBER AND LOCATION OF REQUIRED TESTS SHALL BE DETERMINED BY THE C'.TY ENGINEER. THE COST OF RETESTING DUE TO FAILED COMPACTION TESTS WILL BE BACKCHARGED TO THE CONTRACTOR, NOTE TO CONTRACTOR ALL MANHOLES AND CLEANOUTS WITHIN TRACT, INCLUDING EXISTING MANHOLES, SHALL BE ADJUSTED TO FINISH GRADE IN ACCORDANCE WITH CITY STANDARDS. EXISTING MANHOLES MAY REQUIRE REMOVAL OF EXISTING CONE, AND REMOVAL OR "CHANGE OUT" OF BARREL RINGS. CITY STANDARD PLATES 1. THE FOLLOWING CITY OF BAKERSFIELD STANDARD DRAWINGS SHALL BE CONSIDERED A PART OF THESE PLANS. -ft"eyue O tr (CONTRACTOR TO OBTAIN LATEST EDITION, 10-26-89, THEREOF UNLESS OTHERWISE NOTED) W L� J � U Z N Q O Z o' r%> CIN STD. No. DESCRIPTION �QY CITY STD. No. DESCRIPTION Q m O Q W W Yc WQ Z T 0_ ® SW -1 SEWER LATERAL MARKER ❑ D-6 U LANDSCAPED CONSTRUCTED CHANNELS lY N Q� W W z ❑ SW -2 TRENCH SECTION FOR CONCRETE ENCASED PIPE ❑ D-7 RIGHT OF WAY FOR CONSTRUCTED CHANNELS Dee ~p o 0 W a 07 W � 5 ❑ SW -3 PAVEMENT PATCHES ❑ D-8 RIGHT OF WAY FOR LINED CONSTRUCTED CHANNELS 4 U ® SW -4 MANHOLE, TYPE "A" ❑ D-9 PIPE SADDLE DETAIL ¢ U ® SW -5 FRAMES & COVER FOR MANHOLES & CLEANOUTS ❑ D-10 SIDEWALK UNDERDRAIN ® SW -6 6" CLEAN OUTV) ® D-11 DRAINAGE BASIN c=n Q In cp N ® SW -7 HOUSE CONNECTION WITH VCP SADDLE ® D-12 CHAIN LINK FENCES ❑ SW -8 INDUSTRIAL SAND TRAP ® D-13 CHAIN LINK GATES �m�o, o0 ❑ SW -10 SAND TRAP ® D-14 CATCH BASIN, TYPE "A" ❑ SW -11 HOUSE CONNECTION WITH CAST IRON SADDLE ❑ D-15 CATCH BASIN, TYPE "A-1" ❑ SW -12 SEWER LIFT STATION VALVE BOX ® D-16 GUTTER DEPRESSIONS oz w o ❑ D-1 INTENSITY VS. DURATION CURVESw ❑ D-17 JUNCTION BOX ❑ D-2 RATIONAL METHOD RUNOFF COEFFICIENTS ❑ "8" r ¢ N r D-18 MANHOLE, TYPE ❑ D-3 CHANNEL PROTECTION ❑ D-19 DRAINAGE WELL, TYPE "B" m o ❑ D-4 CHANNEL PROTECTION ® ST -22 DATED 1/11/99 TRENCH BACKFILL AND COMPACTION REQUIREMENTS J o ❑ D-5 RIGHT OF WAY FOR NATURAL CHANNELS ❑ ST -6 DATED 1/11/99 PAVEMENT PATCHES O8YS P¢cOM D(LAwlal- "~ Q� q All eye OF CAV*OP fc.M DM, FwcI q 411'1 0 A OWN T. SHEET '? - ; ek, I -, y COB RECORDS No. 2 OF 8 SHTS. Q z Z O tr H O W L� J � U Z N Q O Z o' W W �QY Z O- Q _M O Q W W Yc WQ Z T 0_ (n C_ d O 0 U� U ~ lY N Q� W W z Q LJ U (n D' Dee !Y H W Y W a 07 W � J O U SHEET '? - ; ek, I -, y COB RECORDS No. 2 OF 8 SHTS. z O H W U W U W I- � W O W r T 0_ (n SHEET '? - ; ek, I -, y COB RECORDS No. 2 OF 8 SHTS. CONSTRUCTION NOTES ® INSTALL SEWER MANHOLE © INSTALL SEWER CLEANOUT INSTALL SEWER INSTALL STORM DRAIN -----wrR---- PROPOSED WATER MAIN (SEE WATER PLANS) ® INSTALL STORM DRAIN MANHOLE %oC INSTALL TYPE "A" CATCH -BASIN — - - — RIGHT-OF-WAY ---SWR-- EXISTING SEWER -- SD ---- EXISTING STORM DRAIN EXISTING EDGE OF PAVEMENT SD STORM DRAIN STATION SS SANITARY SEWER STATION z R q w � Iy�l w x� x,." ALL PLAN VIEW STATIONING IS BASED ON CENTERLINE DATA UNLESS OTHERWISE NOTED. ALL SEWER LATERALS ARE 4" UNLESS OTHERWISE NOTED. ALL SEWER LATERAL STATIONING IS AT POINT OF CONNECTION WITH SEWER MAIN. ALL SEWER LATERALS ARE TO HAVE A MINIMUM OF 2.5' OF COVER AT GUTTER FLOWLINE AND A 2.25' MIN. - 7' MAX. OF COVER AT THE PROPERTY LINE. IN CUL-DE-SACS AND KNUCKLES, DISTANCES FROM LOT LINES TO SEWER LATERALS ARE ON CURVE ALONG STREET RIGHT-OF-WAY. NOTE "A": CONSTRUCT CMP RISER OVER PROPOSED SEWER MANHOLE PER DETAIL ON SHEET 3 0` e + X + X�G %oC x�G �V 5Y5 34565 W i - TOE OF SLOPE M r� x x2 \ k + x� x,." XEG rn EX 10" SEW€R- - - - - rTOE OF SLOPE - EXISTING FIBER OPTIC LINE (APPROXIMATE) 9 _ _ ! - -- _ - - . _ x a" 346 08x x�, xe'0, w x2,1 rEXiSTINO 12"a WATER MAIN } a — ----- — `rte \� -------a---- �n —at-- x'��TOP OF SLOPE x�'" K�0 %ate xT" x<� x TOP OF SLOPE j. x�_ ---- 1 ------- --._ _� Bl - _-. _--- 8 ------ --- _—�-- �— --- EXISTING EDGE OF 1: 0: 10+77.94 -- ----_—� -- --- -- ---—'---- d N89'32'17'32'17"W_-- _____ x EXISTING MEDIAN w �EXISTING CURB, GUTTER SIDEWALK _ __ .. --- --- --- u h„ z F W 348 .. ....... 344 BLOCK WALL F - _ - yam.-.---�-----'_�F-- -r -,r- --.. SEEIJ TE"B" o Ir T — -_ _ - 0 J _LSEE NOTE \ PROPOSED PRIVATE IRRIGATION MAIN -SHOWN FOR REFERENCE ONLY (SEE IRRIGATION PLANS FOR DETAILS AND DIMENSIONS) 340 ...ii...,...: . 336 332 328FX = — 10' SEWER �r PHASE 1 TA F T HIGHWAY INSTALL 275.5± L.F. 0" PVC SEWER ® 0.20% U w p Z Z O Q U � d' IN 1 HEATH'"EAD DRIVE NOTE "B" (SEE SHEET 4) LANDSCAPE LOT IN FAVOR OF THE CITY OF BAKERSFIELD TO BE DEDICATED ON FINAL MAP. NOTE "C" 10' WIDE PRIVATE IRRIGATION MAIN EASEMENT TO BE DEDICATED BY SEPARATE INSTRUMENT. INSTALL 272.2± L.F. 10" PVC SEWER ® 0,20% EEiISTII19 q2";WATER MAIN x 1. 00 12+82.00 13 I !_ )�SEE NOTE "C" `39 83 `NOTE "D": 10 AN ENCROACHMENT PERMIT FOR IRRIGATION m CROSSING IS REQUIRED UNLESS WAIVED BY PUBLIC WORKS DIRECTOR. OWS� INSTALL 39.8± L.F. 0" PVC SEWER ® 0.20% �1.......... 348 344 340 ..,....:336 ....332 BUILD END FOR FUNRE �.EXTENS:ON BY OTHERS \°';, ...:.... 328 324:. •= NEGATIVE SLOPE ELEVATION FROM EXISTING STUB TQ MANHOLE .��' .324 . ..... 7+00 8+00 9+00 10+00 11+00 12+00 13+00 SEWER LINE PROFILE HORIZONTAL: 1"=40' VERTICAL: 1"=4' pRBFESS/p y� + inelraw REVISION � Engineering 0``p OORY O, A�F.c APPROVED BY: t}�o hand 5u&rvesing — GRE CK R.C.E. 53592 DATE NO.G 953952 x m 9 * Exp. 11��7' * 2 NR.YOPREVISION I/i 1/ I1N 1/ ! CALF APPROVED BY: J' 11"fPP�"`°° I V 7 11/ LD Q DANIEL PADILLA R.C.E. 67008 DATE w 4 U O O - o D' OLJ^ap � � n 36"0 CMP PIPE o 0 0 0 Z U TOP OF CMP RISER r o j Z m U O Z ---------------__--` NATURAL GRODUAD o n --- Y O U N r w IO ¢O \ TOP OF MANHOLE z_ � m Y � U C.M.P. PIPE RISER DETAIL 3 NO SCALE p ItECotM oNwwy W �N C03952� 'm.. -[KA%L� K(1f/t5 aq N1 P�3 SOF GAL* l, -a --) 5,3 ph COB RECORDS No Q z O LL J V) U z U N Q cnU Z J :2¢Y z 0- QO _� o w r CO > W Q Z rC O O0 UM U � EN O LLI Qr W_ Z JF- E Q L U UJ Q D� Q� w w F- Y QW m (n L� O r U z O H W W 0 01)w U � W — LLI W _E D_ u� SHEET OF 8 SIFTS, + x'' W i - TOE OF SLOPE M r� BLOCK WALL F - _ - yam.-.---�-----'_�F-- -r -,r- --.. SEEIJ TE"B" o Ir T — -_ _ - 0 J _LSEE NOTE \ PROPOSED PRIVATE IRRIGATION MAIN -SHOWN FOR REFERENCE ONLY (SEE IRRIGATION PLANS FOR DETAILS AND DIMENSIONS) 340 ...ii...,...: . 336 332 328FX = — 10' SEWER �r PHASE 1 TA F T HIGHWAY INSTALL 275.5± L.F. 0" PVC SEWER ® 0.20% U w p Z Z O Q U � d' IN 1 HEATH'"EAD DRIVE NOTE "B" (SEE SHEET 4) LANDSCAPE LOT IN FAVOR OF THE CITY OF BAKERSFIELD TO BE DEDICATED ON FINAL MAP. NOTE "C" 10' WIDE PRIVATE IRRIGATION MAIN EASEMENT TO BE DEDICATED BY SEPARATE INSTRUMENT. INSTALL 272.2± L.F. 10" PVC SEWER ® 0,20% EEiISTII19 q2";WATER MAIN x 1. 00 12+82.00 13 I !_ )�SEE NOTE "C" `39 83 `NOTE "D": 10 AN ENCROACHMENT PERMIT FOR IRRIGATION m CROSSING IS REQUIRED UNLESS WAIVED BY PUBLIC WORKS DIRECTOR. OWS� INSTALL 39.8± L.F. 0" PVC SEWER ® 0.20% �1.......... 348 344 340 ..,....:336 ....332 BUILD END FOR FUNRE �.EXTENS:ON BY OTHERS \°';, ...:.... 328 324:. •= NEGATIVE SLOPE ELEVATION FROM EXISTING STUB TQ MANHOLE .��' .324 . ..... 7+00 8+00 9+00 10+00 11+00 12+00 13+00 SEWER LINE PROFILE HORIZONTAL: 1"=40' VERTICAL: 1"=4' pRBFESS/p y� + inelraw REVISION � Engineering 0``p OORY O, A�F.c APPROVED BY: t}�o hand 5u&rvesing — GRE CK R.C.E. 53592 DATE NO.G 953952 x m 9 * Exp. 11��7' * 2 NR.YOPREVISION I/i 1/ I1N 1/ ! CALF APPROVED BY: J' 11"fPP�"`°° I V 7 11/ LD Q DANIEL PADILLA R.C.E. 67008 DATE w 4 U O O - o D' OLJ^ap � � n 36"0 CMP PIPE o 0 0 0 Z U TOP OF CMP RISER r o j Z m U O Z ---------------__--` NATURAL GRODUAD o n --- Y O U N r w IO ¢O \ TOP OF MANHOLE z_ � m Y � U C.M.P. PIPE RISER DETAIL 3 NO SCALE p ItECotM oNwwy W �N C03952� 'm.. -[KA%L� K(1f/t5 aq N1 P�3 SOF GAL* l, -a --) 5,3 ph COB RECORDS No Q z O LL J V) U z U N Q cnU Z J :2¢Y z 0- QO _� o w r CO > W Q Z rC O O0 UM U � EN O LLI Qr W_ Z JF- E Q L U UJ Q D� Q� w w F- Y QW m (n L� O r U z O H W W 0 01)w U � W — LLI W _E D_ u� SHEET OF 8 SIFTS, CONSTRUCTION NOTES OS INSTALL SEWER MANHOLE © INSTALL SEWER CLEANOUT 0 INSTALL SEWER - INSTALL STORM DRAIN -----WTR---- PROPOSED WATER MAIN (SEE WATER PLANS) ® INSTALL STORM DRAIN MANHOLE IFL� INSTALL TYPE "A" CATCH -BASIN — - - — RIGHT-OF-WAY - -SWR- - EXISTING SEWER -----SD--- EXISTING STORM DRAIN - -- �-- EXISTING EDGE OF PAVEMENT SD STORM DRAIN STATION SS SANITARY SEWER STATION 11 12 13 ALL PLAN VIEW STATIONING IS BASED ON CENTERLINE DATA UNLESS OTHERWISE NOTED. ALL SEWER LATERALS ARE 4" UNLESS OTHERWISE NOTED. ALL SEWER LATERAL STATIONING IS AT POINT OF CONNECTION WITH SEWER MAIN. ALL SEWER LATERALS ARE TO HAVE A MINIMUM OF 2.5' OF COVER AT GUTTER FLOWLINE AND A 2.25' MIN. - 7' MAX. OF COVER AT THE PROPERTY LINE. IN CUL-DE-SACS AND KNUCKLES, DISTANCES FROM LOT LINES TO SEWER LATERALS ARE ON CURVE ALONG STREET RIGHT-OF-WAY. NOTE "A": CONSTRUCT CMP RISER OVER PROPOSED SEWER MANHOLE PER DETAIL ON SHEET 3 LIBERTY RIDGE COURT (SEE SHEET 5) '. 'c Ls'%'- 1A no.0 95/4952 � m ST 1 Sy�P OF cfE"i A w w 9 8 7 6 5 0 4 3 2 1 O n_ LAJ Nm ¢ + + U z Q N Z N_ + + ZLLJ LLJa Y z_ oU) w U Q w o w Y } w W D- 32 12 — N00 -39'39E13 BOUNDARY NOTE "B": AN ENCROACHMENT PERMIT FOR IRRIGATION CROSSINC IS REQUIRED UNLESS WAIVED BY °cy�' PUBLIC WORKS DIRECTOR. SEE NOTE '( NOTE "C" 10' WIDE PRIVATE IRRIGATION MAIN EASEMENT TO BE DEDICATED BY SEPARATE INSTRUMENT. PHASE 1 HEATHER MEADOWS DRIVE INSTALL 332.0± L.F. 8" PVC SEWER 0 0.359 1-- WTR - ISI II I ARIES 11,11 VARIES TAFT HIGHWAY (SEE SHEET 3) 0 hl J 3 � I z N_x I W I mms__z HORIZONTAL: 1"=40' VERTICAL: 1"=4' m o+ O �y M N all 346. . . . . . . . . r. . . . . . . . . . . . . . . . . . . . . . . . . . . . APPROX/MA 7b DES/GN GRAOE .l �'- rte.......... .... .. ........ _ _ ........ ?� ... 46 . 7 ABOVE ' 5FWFF' MAIN '. ° _ _ — — — A � 3 $10 __------�-- — -- ----- ----.. q�:. y� ---------------- — — o't: ..:. .:. ..342 342. >'< . . . . . _ _ .APPROXIMATE LOCATION OE EXISTING 12" WATER MAIN (PROTECT IN PLACE) CONTRACTOR SHALL VERIFY EXISTING ELEVATION AND LOCATION IN FIELD, ,PRIOR' TO CONSTRUCTION' AND NOTIFY ENGINEER IF . . THERE ARE ANY DISCREPANCIES. , 338 .. .. .. .: 338 334: ..: .. .. III III IL ^.. 334 SEWER LINE PROFILE > REVISION APPROVED BY: > DANIEL PADILLA R.C.E. 67008 DATE Qjy0fES5/0 ��F9 Goer o. � y wt.) 044ji- 3 "a . - 1 FKA7£ i 9 E P. sT,q N I �QF CA61c0 I.2-7 5"3 AI -I')- COB RECORDS No. Palmetto Engineering Land Sa veying r7 r7 I.7 0 �a z �o 0 o = W O O Y p7 v M o r N o c� o0 r o m ..wzmcY.�o ¢ ¢ P m Y U H O SHEET 1 D'OF� 8 SHTS. Q z z 0 F 0 C_ LAJ w ¢ G_ F U z Q N Z J � 0 In w ZLLJ LLJa Y z_ oU) w U Q w o w Y } w W D- z w 0,0- O O CJ U In N Q^ W t] Z u �U Q L:� � Y Gee W DD Lil Cn O r U SHEET 1 D'OF� 8 SHTS. z 0 F C_ LAJ G_ F U H � w o U w w o w SHEET 1 D'OF� 8 SHTS. CONSTRUCTION NOTES ® INSTALL SEWER MANHOLE © INSTALL SEWER CLEANOUT INSTALL SEWER LZ 0 INSTALL STORM DRAIN �Q -----A7R---- PROPOSED WATER MAIN (SEE WATER PLANS) ® INSTALL STORM DRAIN MANHOLE INSTALL TYPE "A" CATCH -BASIN ak RIGHT-OF-WAY — - - — --swR-- EXISTING SEWER ----SD----- EXISTING STORM DRAIN -- - - - EXISTING EDGE OF PAVEMENT SD STORM DRAIN STATION SS SANITARY SEWER STATION ALL PLAN VIEW STATIONING IS BASED ON CENTERLINE DATA UNLESS OTHERWISE NOTED. ALL SEWER LATERALS ARE 4" UNLESS OTHERWISE NOTED, ALL SEWER LATERAL STATIONING IS AT POINT OF CONNECTION WITH SEWER MAIN. ALL SEWER LATERALS ARE TO HAVE A MINIMUM OF 2.5' OF COVER AT GUTTER FLOWLINE AND A 2.25' MIN. - 7' MAX. OF COVER AT THE PROPERTY LINE. IN CUL-DE-SACS AND KNUCKLES, DISTANCES FROM LOT LINES TO SEWER LATERALS ARE ON CURVE ALONG STREET RIGHT-OF-WAY. NOTE "A": CONSTRUCT CMP RISER OVER PROPOSED SEWER MANHOLE PER DETAIL ON SHEET 3 PHASE 1 LIBERTY RIDGE COURT INSTALL 262.9± L.F. _ INSTALL 393.6± L.F. 8" PVC SEWER ® 0.35% 6" PVC SEWER ® 1.17 CHEVALIER ROAD I �Il HORIZONTAL: 1"=40' VERTICAL: 1"=4' Land V Q M U LZ 0 �Q L� U ak Qz Q U r U � r W � a J w O U Z W � Z wQ J HEATHER MEADOWS Qo ry r o w �< wa r Q� 0 0 DRIVE _ .n Qr 9(--po DtAvgA-w w� = z Q PW+s� I Q � H /tis/ly o r�'- Ld r (SEE SHEET 4) W� W moo U) Q C J K Y¢ p L� 0 F- 3 U 3FESS)Q 3 z O ~ 0 Fy W 0_ 3952 m H U A F U) Li 7 - 7 * P Li0 ryl �S U 1 20 20' 10' o CALIF�Q O W w m O.. (7) 8 T+ r m N m I I / 32 31 30 29 28 27 26 25 24 23 22 9 I + o L=20.r + + + + (1 I O N M M J Y I[f N m 0+600�0—� N M 10 T 12 3 4 5 6 +41.57 mM C mM -- ----- ---------hit---- ---------------------------- -wrr-------------------- + -------------- - ---------- _ ---r ---------- --------------------- \ i no L=226 aO + + + + + 11 s ' L=21. NN= 12 10 20 20I 10' 14 15 113 6 1GARETT 17 18 19 20 2/1 CANYON DRIVE (SEE SHEET 8) PHASE 1 LIBERTY RIDGE COURT INSTALL 262.9± L.F. _ INSTALL 393.6± L.F. 8" PVC SEWER ® 0.35% 6" PVC SEWER ® 1.17 CHEVALIER ROAD I �Il HORIZONTAL: 1"=40' VERTICAL: 1"=4' Land /,a--7jr-3 PA/j COB RECORDS No SHEET 5 OF 8 SHTS. Q M m 0 �Q L� Qz Q U r U � r W � a J w O U Z W � Z wQ z o- Qo ry r o w �< wa r Q� 0 0 .n Qr 9(--po DtAvgA-w w� = z Q PW+s� I Q � H /tis/ly Y r�'- Ld r o m W moo U) Q C J K Y¢ p L� 0 /,a--7jr-3 PA/j COB RECORDS No SHEET 5 OF 8 SHTS. Q z 0 L� Qz U N a J O U Z W � Z wQ z o- Qo ry w �< wa z z Q� 0 0 .n Qr 9(--po DtAvgA-w w� = z Q PW+s� I Q � H /tis/ly Y r�'- Ld Q M W U) L� 0 F- U 3FESS)Q z O ~ 0 Fy W 0_ 3952 m H U A F U) Li 7 - 7 * P Li0 ryl �S U CALIF�Q O W w O.. (7) /,a--7jr-3 PA/j COB RECORDS No SHEET 5 OF 8 SHTS. CONSTRUCTION NOTES ® INSTALL SEWER MANHOLE © INSTALL SEWER CLEANOUT O INSTALL SEWER fy INSTALL STORM DRAIN -----wm---- PROPOSED WATER MAIN (SEE WATER PLANS) O INSTALL STORM DRAIN MANHOLE w INSTALL TYPE "A" CATCH -BASIN — - - — RIGHT-OF-WAY - - -SWR- - EXISTING SEWER -----SD----- EXISTING STORM DRAIN - - - EXISTING EDGE OF PAVEMENT SD STORM DRAIN STATION SS SANITARY SEWER STATION ALL PLAN VIEW STATIONING IS BASED ON CENTERLINE DATA UNLESS OTHERWISE NOTED. ALL SEWER LATERALS ARE 4" UNLESS OTHERWISE NOTED. ALL SEWER LATERAL STATIONING IS AT POINT OF CONNECTION WITH SEWER MAIN. ALL SEWER LATERALS ARE TO HAVE A MINIMUM OF 2.5' OF COVER AT GUTTER FLOWLINE AND A 2.25' MIN. - 7' MAX. OF COVER AT THE PROPERTY LINE. IN CUL-DE-SACS AND KNUCKLES, DISTANCES FROM LOT LINES TO SEWER LATERALS ARE ON CURVE ALONG STREET RIGHT-OF-WAY. NOTE "A": CONSTRUCT CMP RISER OVER PROPOSED SEWER MANHOLE PER DETAIL ON SHEET 3 INSTALL 384.0± L.F. PVC SEWER 0 0.6E PHASE 2 JAMES VALLEY COURT INSTALL 394.2± L.F. 6" PVC SEWER ® 0.6` ILIER 0 NOTE "B" 10' WIDE STORM DRAIN EASEMENT IN FAVOR OF THE CITY OF BAKERSFIELD TO BE DEDICATED ON FINAL MAP, I A -NN- HORIZONTAL: 1"=40' VERTICAL: 1"=4' 346 NOR FL= NOR FL= 343.63 342 338..,.:,, ..:.... .. ... , ..., .:...:. 334' 338 s' iNv h- pp04E ro OFY ry <oR0 PRAWN' m " zm Q7�k5fi 2 952 x m 9 TV av SOF CAIlF�P Land r o m . i.iz mcYio �acP�m i FPO0 SHEET �'- COB RECORDS No. 6 OF 8 SHTS. Q Z z O fy H O O w w J Q � U z N Q J �Z IL H W p U 0- O Q N � Q_ W w W< I-- Z _ � 0 O C)U ~ n Q Ir Li JL- LLJ w Q U U (n Q G' 0:� H W Y W a m w � L� 0 U SHEET �'- COB RECORDS No. 6 OF 8 SHTS. Z O H O w U H � W H p U w � � w O w 0'. _ d In SHEET �'- COB RECORDS No. 6 OF 8 SHTS. CONSTRUCTION NOTES ® INSTALL SEWER MANHOLE ® INSTALL SEWER CLEANOUT 0 INSTALL SEWER INSTALL STORM DRAIN - - -----wrR---- PROPOSED WATER MAIN (SEE WATER PLANS) ® INSTALL STORM DRAIN MANHOLE Ila INSTALL TYPE "A" CATCH -BASIN RIGHT-OF-WAY Z < ---SwR-- EXISTING SEWER -----sD----- EXISTING STORM DRAIN U� EXISTING EDGE OF PAVEMENT SD STORM DRAIN STATION SS SANITARY SEWER STATION ALL PLAN VIEW STATIONING IS BASED ON CENTERLINE DATA UNLESS OTHERWISE NOTED. ALL SEWER LATERALS ARE 4" UNLESS OTHERWISE NOTED, ALL SEWER LATERAL STATIONING IS AT POINT OF CONNECTION WITH SEWER MAIN. ALL SEWER LATERALS ARE TO HAVE A MINIMUM OF 2.5' OF COVER AT GUTTER FLOWLINE AND A 2.25' MIN. - 7' MAX. OF COVER AT THE PROPERTY LINE. IN CUL-DE-SACS AND KNUCKLES, DISTANCES FROM LOT LINES TO SEWER LATERALS ARE ON CURVE ALONG STREET RIGHT-OF-WAY. NOTE "A": CONSTRUCT CMP RISER OVER PROPOSED SEWER MANHOLE PER DETAIL ON SHEET 3 m^ Q Z z z 0 0 o w 2 a aZ' Z < U 0 z Q O J U� U CONSTRUCT 16.7± L.F. 18" 8" SWR INV - CL -3 RCP w/RGJ 336.3± STORM DRAIN ® 0.30% S9, INSTALL CONCRETE PIPE J3, S u� iq,L SADDLE PER C.O.B. STD. DWG. D-18. 335. to 466 -ft p 346 ... ....:...:...: 342... . .: 338 .. :...:.......:.I INSTALL 100.0± L.F. �6" PVC SEWER 0 1,00% I� PHASE 2 PITCHER VIEW COURT INSTALL 285.2± L.F. PVC SEWER ® 0.36 o r a I � U K�K W W F O I O N O Q z � 4 U � H I O 3 � � w � 0 o o APPRO11MA 7F DES/GN GRADE ABO l E SEWER AND STORM ORAIN 342. S6' s ------------ --- --- ---- ---\� INSTALL 310.0± L.F. 8" PVC SEWER 0 0.3` INSTALL 90.0± L.F. PVC SEWER 0 1.06%� w APPROXIMATE DESIGN GRADE ABOVE STORM DRAIN �8" WATER X-ING \ L24"INV RUCT 55.6'± LF 24" RCP w/RGJ DRAIN 0 0.09% CONSTRUCT OUTLET STRUCTURE PER C.O.B. STD. DWG. D-11 W/ 2' CUTOFF AT END OF BOX BASIN FLOOR 24" INV S-E=�( 331.40 331.mCS) 33t.84'(E) STORM DRAIN SECTION N.T.S. I I I CHEVAI RON III .IER HORIZONTAL: 1"=40' VERTICAL: 1"=4' .......... .. .: 346 33516 11 .. ......... .:. 3,38 as 336.3 B• INv EW a F . 334 ...... 6—,,N-- .33 z$ CE.). .. .. .. .. .. .. ...:.. 334 336.95: 33S 7 GCw) 33(e.3+i 33/s.M1 4".INV N -W= z4" INv s -e aaQea 332.04 331. : C,ai ............... .. .................... 330 331.SLCE):... .. (v9 330 INSTALL 285.21 L.F. 24' . � CL-3�RCP w./RGJ STORM DRAIN 0 0.08% 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 SEWER AND STORM DRAIN PROFILE gNOFESSl6 ��P�GOFY DMw1a4 - c� ¢ N�95952NA 2 * :P(z1 NIl 5/f2 -1/2A FDf GP11; pP ��A't> COB RECORDS No. Land M Q z z 0 0 o w 2 a aZ' Z < O z Q O J U� Z w Y z_ O r VI Q G) � LI V) G7 >- w W Q Z w � • O o w o w Ln < N LL h .......... .. .: 346 33516 11 .. ......... .:. 3,38 as 336.3 B• INv EW a F . 334 ...... 6—,,N-- .33 z$ CE.). .. .. .. .. .. .. ...:.. 334 336.95: 33S 7 GCw) 33(e.3+i 33/s.M1 4".INV N -W= z4" INv s -e aaQea 332.04 331. : C,ai ............... .. .................... 330 331.SLCE):... .. (v9 330 INSTALL 285.21 L.F. 24' . � CL-3�RCP w./RGJ STORM DRAIN 0 0.08% 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 SEWER AND STORM DRAIN PROFILE gNOFESSl6 ��P�GOFY DMw1a4 - c� ¢ N�95952NA 2 * :P(z1 NIl 5/f2 -1/2A FDf GP11; pP ��A't> COB RECORDS No. Land M SHEET 7 OF 8 SHiS.I Q z z 0 0 o w LL a 0 z N Q J U� Z Z LLJa w Y z_ O r Q Q G) � LI V) G7 >- w W Q Z w 0'0- O O d cf) Ln < N LL h JLLJ I- Q JU n Q C [If c' W Q m W 0 L� O H U SHEET 7 OF 8 SHiS.I z 0 o w U I— o U W � � w o w d cf) SHEET 7 OF 8 SHiS.I CONSTRUCTION NOTES CJ H Z ? OO INSTALL SEWER MANHOLE ALL PLAN VIEW STATIONING IS BASED ON CENTERLINE DATA UNLESS OTHERWISE NOTED. © INSTALL SEWER CLEANOUT ALL SEWER LATERALS ARE 4" UNLESS OTHERWISE NOTED. = INSTALL SEWER ALL SEWER LATERAL STATIONING IS AT POINT OF CONNECTION WITH SEWER MAIN. z INSTALL STORM DRAIN ALL SEWER LATERALS ARE TO HAVE A MINIMUM OF 2.5' OF COVER AT GUTTER m -----WTR---- PROPOSED WATER MAIN (SEE WATER PLANS) FLOWLINE AND A 2.25' MIN. - 7' MAX. OF COVER AT THE PROPERTY LINE. 0 INSTALL STORM DRAIN MANHOLE IN CUL-DE-SACS AND KNUCKLES, DISTANCES FROM LOT LINES TO SEWER LATERALS �., INSTALL TYPE "A" CATCH -BASIN ARE ON CURVE ALONG STREET RIGHT-OF-WAY. - - - - RIGHT-OF-WAY NOTE "A": CONSTRUCT CMP RISER OVER PROPOSED SEWER MANHOLE PER DETAIL JAMES VALLEY ON SHEET 3 SWR EXISTING SEWER Q r- -----SO----- EXISTING STORM DRAIN av I EXISTING EDGE OF PAVEMENT z SD STORM DRAIN STATION Z g SS SANITARY SEWER STATION PITCHER VIEW COURT (SEE SHEET 7) III 40 I I 41 r I CONSTRUCT 25.7±L.F. 18" CONSTRUCT 15.71 L.F. 18" CL -3 RCP w/RGJ CL -3 RCP W/RGJ STORM DRAIN ® 0.19% STORM DRAIN ® 0.32% 4-L- 1�� 4 N @ CJ H Z ? OJ lk O W W J S U 3 O N = z U OU z O Z m N T W N� rn N VI a &wm 334.o1C�) 3U.33 4 M X Y M JAMES VALLEY (� STORM M lc�ro DtwkK Q r- (SEE SHEET 6) �.. av I � z as Z O Z g 1 1 0'1 20 10 y (=sh9 s J � m m w O Ul � �' L� W W o 3 W W r LIBERTY RIDGE COURT U (SEE SHEET 5) N 15 I 1 30 LL) Lj CONSTRUCT 25.7±L.F. 18" CONSTRUCT 15.71 L.F. 18" CL -3 RCP w/RGJ CL -3 RCP W/RGJ STORM DRAIN ® 0.19% STORM DRAIN ® 0.32% 4-L- 1�� 4 N @ CJ H Z ? OJ lk O W W J S U 3 O N = z U OU Z O Z N N= 4INVS234.33CE) =334.5± T W N� O VI a &wm 334.o1C�) 3U.33 3 VI O JAMES VALLEY (� STORM COURT lc�ro DtwkK Q r- (SEE SHEET 6) �.. 31 30 I 19 z 610. Z O Z g 1 1 0'1 20 10 y (=sh9 s J � m m w O 1 6 7 'l 3 13 N -00'27'43"E - 14: Ir ' 2+69.00 1 - - Y -;ITT _ _ _.- imu 15 15+38.00 I --WTR-----y 28 16 MmI HORIZONTAL: 1"=40' VERTICAL: 1"=4' O 346 342.4.4 342 ..�. 338 .. :. 3 35 14 1,�V 'E- INV 4= 334 33S.zs Ec ) OIC m O 18" INV E=/ 18" INV= 1 A18' INV W= O W 40II-m 337 4& -es. 33" t.1 s in z in 3 o 18" INV E -W= O Z B•331.43SWRINV= 18" INV N= 4INVS234.33CE) =334.5± LL as L 33S1 a &wm 334.o1C�) 3U.33 3 VI (� STORM DRAIN SECTION lc�ro DtwkK Q r- �.. N.T.S. N o i W � z Z O Z g y (=sh9 J � m m w O Ul � �' L� O r LIBERTY RIDGE COURT U (SEE SHEET 5) N 15 I 1 30 LL) Lj F- Fy Q 2 Il 1: 20' 20' 10' ~ CL a s2m s LJ H ORSr o w w 29 a cn 'l 3 13 N -00'27'43"E - 14: Ir ' 2+69.00 1 - - Y -;ITT _ _ _.- imu 15 15+38.00 I --WTR-----y 28 16 MmI HORIZONTAL: 1"=40' VERTICAL: 1"=4' O 346 342.4.4 342 ..�. 338 .. :. 3 35 14 1,�V 'E- INV 4= 334 33S.zs Ec ) OIC m O O O � O W O w vx 0 in z in 3 o s z O Z N N m LL PO UI 3 VI PHASES 1-2 GARETT CANYON DRIVE INSTALL 269.0± L.F. S" PVC SEWER ® 0.3` INSTALL 119.5± L.F. PVC SEWER ® 0.3: INSTALL 149.5± L.F. PVC SEWER 0 0.35%� w W = W = J W 2 = W F� O O O O Z x O W 2 2 Z O Z O z O Z Z K O Z HH H LL H W ¢ 0 W' W J W J J W 3 N N ti o o O o oN uj i vi N x a + �2 346 ARGROX/MATE LIE5/GN GRAOE �4.3N1:56 311.0 �a 3N1.i1 'ABOVE � SEVYER' AND: STORM ORA /N: ----------�-----------3+11_81---------- 42 �._ _---.---.--�_--.---- -- --- . ..... IIx 3 �X 11 3bS.`S1s) s34.33CE� ... .. . . ... .. .__I8" INV E -W_ B" INV N=' 33zBQ 33S.:1s. 33s 1'I' 18 INV N .:338 3PLUG EN FOR R A5 EXTENSION IO 6 ��a 334 s% e', 33H.3o LY) 334.3515) z4"wN=n24vs= s. . : . .t . ..... .... ........ a.40 .. �. :33.2•ore�ia) �3+•�s 334.141La) INSTALL 42.8± L.F. 18" 330. 3.3i•oNCcs) 331.31 . .. -CL-3 RCP W/RGJ STORM 'DRAIN. @ 0.11%. .:330 INSTALL 226.3± "LF 24" . : CL .3 RCP.w/RGJ STORM DRAIN. ® 0.08% : : : : : : . : . 3 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 SEWER AND STORM DRAIN PROFILE land surveymg Z 0 w Of Q z 0_ 0 LL J � :o(�n p¢Ad4k1 ¢ Z U Q N J �Z W 5(2 r2O Q Y Z / ) , %d$`? /�A /"4 COB RECORDS No. SHEET 8 of 8 SHTS. O - LL U Q _ U] 0 W LLl Q Z => LL lc�ro DtwkK Q r- -P11 LLJ0 W � z y (=sh9 w m m w � L� 0 r U z 0 F- Fy LJ Il ~ U s2m LJ H ORSr o w w a cn / ) , %d$`? /�A /"4 COB RECORDS No. SHEET 8 of 8 SHTS.